Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Thorac Cardiovasc Surg ; 68(2): 114-123, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-30497085

RESUMEN

INTRODUCTION: Sutureless biological valves for surgical aortic valve replacement (SAVR), characterized by the absence of anchoring sutures at the aortic annulus, are gaining popularity because of ease and reproducibility of implant, shorter operating times, and enhancement of minimally invasive approaches. The stentless configuration of the sutureless valve was designed to achieve optimal hemodynamic performance. MATERIALS AND METHODS: PERSIST-AVR (PERceval Sutureless Implant versus STandard Aortic Valve Replacement) is a prospective, randomized, adaptive, open-label, international, postmarket trial (NCT02673697). The primary objective of the trial is to assess the safety and efficacy of the Perceval (LivaNova, London, UK) sutureless bioprosthesis among patients undergoing SAVR in the presence of severe aortic stenosis to demonstrate the noninferiority of Perceval as compared with standard sutured stented bioprosthetic aortic valve as an isolated procedure or combined with coronary artery bypass grafting. Sample size will be determined adaptively through interim analyses performed by an Independent Statistical Unit till a maximum of 1,234 patients, enrolled at ∼60 sites in countries where the device is commercially available. Patients will be followed up for 5 years after implant. The primary end point is the number of patients free from major adverse cardiac and cerebrovascular-related events at 1 year. Additional secondary outcomes will be assessed up to 5 years. DISCUSSION: PERSIST-AVR is the first prospective, randomized study comparing in-hospital and postdischarge outcomes in a robust population of patients undergoing SAVR with either the Perceval sutureless bioprosthesis or a conventional sutured stented bioprosthesis up to 5 years.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Stents , Procedimientos Quirúrgicos sin Sutura/instrumentación , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...