Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
J Artif Organs ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512476

RESUMEN

We have adopted a simple and reproducible approach, "minimal manipulation approach," since January 2021 in five patients to minimize the risk of thromboembolic events during Zone 1 and 2 thoracic endovascular aortic repair (TEVARs) with shaggy aorta. The approach consists of two parts: ① Use of a 65-cm-long sheath (dry seal) to deliver the endografts without touching the protruding atheroma. Covering the atheroma with the first endograft delivered at Zone 3 to the mid-descending aorta (paving the aorta), and second endograft insertion and deployment through the paved aorta with first endograft. ② Protection of the left subclavian artery using balloon catheter during TEVAR. No in-hospital mortality was recorded, and none of the patients had stroke, spinal cord ischemia, or distal embolic events.

2.
J Artif Organs ; 2023 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-37227546

RESUMEN

PURPOSE: A narrow terminal aorta is a risk factor for endograft occlusion after endovascular aneurysm repair. To minimize limb complications, we used Gore Excluder legs positioned side-by-side at the terminal aorta. We investigated the outcomes of our strategy for endovascular aneurysm repair in patients with a narrow terminal aorta. METHODS: We enrolled 61 patients who underwent endovascular aneurysm repair with a narrow terminal aorta (defined as < 18 mm in diameter) from April 2013 to October 2021. The standard procedure involves complete treatment with the Gore Excluder device. When other types of main body endografts were used, they were deployed proximal to the terminal aorta, and we used the Gore Excluder leg device in the bilateral limbs. Postoperatively, the intraluminal diameter of the legs at the terminal aorta was measured to assess the configuration. RESULTS: During the follow-up period (mean: 2.7 ± 2.0 years), there were no aorta-related deaths, endograft occlusions, or leg-related re-interventions. There were no significant differences between the pre- and postoperative ankle-brachial pressure index values in the dominant and non-dominant legs (p = 0.44 and p = 0.17, respectively). Postoperatively, the mean difference rate (defined as [dominant leg diameter-non-dominant leg diameter]/terminal aorta diameter) was 7.5 ± 7.1%. The difference rate was not significantly correlated with the terminal aortic diameter, calcification thickness, or circumferential calcification (r = 0.16, p = 0.22; r = 0.07, p = 0.59; and r = - 0.07, p = 0.61, respectively). CONCLUSIONS: Side-by-side deployment of Gore Excluder legs produces acceptable outcomes for endovascular aneurysm repair with a narrow terminal aorta. The endograft expansion at the terminal aorta is tolerable without influencing calcification distribution.

3.
J Nutr Sci Vitaminol (Tokyo) ; 69(2): 129-135, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37121722

RESUMEN

We have previously reported that lipocalin-type prostaglandin D synthase (L-PGDS) in egg white reacts with IgE antibodies from children with egg allergies. However, antibodies against chicken L-PGDS are not commercially available, and the amount of L-PGDS in egg white is unclear. In this study, we prepared four monoclonal antibodies against chicken L-PGDS and developed a sandwich enzyme-linked immunosorbent assay (ELISA) and a highly sensitive immune complex transfer enzyme immunoassay (ICT-EIA) to quantify L-PGDS in hen egg whites. The detection sensitivity of ICT-EIA for L-PGDS (0.01 ng/mL) was 2,000-fold higher than that of ELISA, which could not be adapted to determine the amount of L-PGDS in egg white. Thus, ICT-EIA is a better method for quantification of trace allergens and expected to be applied to the quantification of other food allergens. Hen eggs (white-shelled eggs from Julia Lite hens, brown-shelled eggs, and iodine-enriched eggs from Boris Brown hens) were purchased from markets in Kochi City, Japan, and the amounts of L-PGDS in them were determined by ICT-EIA. The amounts of L-PGDS per hen egg white were: brown-shelled eggs, 1,179.3±214.3 µg/egg; iodine-enriched eggs, 607.7±126.1 µg/egg; and white-shelled eggs, 350.0±74.1 µg/egg. These results show that the amount of L-PGDS in hen eggs varies depending on the hen lineage; it could also be affected to some extent by other factors, such as feeds and breeding environment.


Asunto(s)
Alérgenos , Clara de Huevo , Complejo Antígeno-Anticuerpo , Anticuerpos Monoclonales , Ensayo de Inmunoadsorción Enzimática , Lipocalinas
4.
Semin Thorac Cardiovasc Surg ; 35(2): 239-248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35181442

RESUMEN

We aimed to investigate cardiac magnetic resonance imaging (MRI)-derived predictors of a lack of left ventricular (LV) reverse remodeling after undersized mitral annuloplasty (uMAP) for moderate ischemic mitral regurgitation (IMR). We retrospectively reviewed 31 patients who underwent uMAP for moderate IMR and cardiac MRI evaluation between 2004 and 2017. Cardiac MRI evaluation included cine MRI LV and right ventricular volumetric measurements and gadolinium-enhanced MRI assessment of myocardial scarring. LV dimensions were assessed preoperatively, postoperatively, and at follow-up using serial transthoracic echocardiography, and the mid-term (median, 49 months) predictors of a lack of LV reverse remodeling were analyzed. At the mid-term follow-up (mean follow-up period: 85 ± 40 months), 15 patients exhibited reverse LV remodeling. The relative reduction in LV dimension at follow-up was negatively correlated with the preoperative number of LV segments with myocardial infarction (MI) (defined as an LV segment with >25% enhancement). The optimal cut-off for predicting a lack of reverse LV remodeling at follow-up was >5 LV segments with MI, with a sensitivity and specificity of 92% and 92%, respectively. This cut-off value also predicted all-cause mortality at follow-up, with a sensitivity and specificity of 88% and 67%, respectively. The presence of >5 LV segments with MI on gadolinium-enhanced MRI might be a useful predictor of lack of reverse LV remodeling and all-cause mortality outcomes after undersized mitral annuloplasty for moderate IMR.


Asunto(s)
Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Puente de Arteria Coronaria/efectos adversos , Estudios Retrospectivos , Gadolinio , Resultado del Tratamiento , Isquemia , Imagen por Resonancia Magnética/efectos adversos , Remodelación Ventricular , Anuloplastia de la Válvula Mitral/efectos adversos
5.
Gen Thorac Cardiovasc Surg ; 71(3): 151-157, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35953640

RESUMEN

OBJECTIVE: The Japanese Off-Pump Coronary Revascularization Investigation (JOCRI) study reported a non-significant difference in early outcomes and graft patency between off-pump coronary artery bypass grafting and on-pump coronary artery bypass grafting in 2005. The JOCRIED study aimed to review the long-term outcomes of the JOCRI study participants. METHOD AND RESULTS: The JOCRIED study enrolled 123 of the JOCRI study participants completing the clinical follow-up between August 2018 and August 2020; 61 patients in the off-pump group and 62 patients in the on-pump group. The follow-up period was 13.8 ± 2.8 years. The groups were compared regarding mortality, the incidence of major adverse cardiac and cerebrovascular events and repeat revascularisation. The 15-year cumulative survival rate (off-pump vs on-pump, respectively; 77.7% vs 75.3%; p = 0.85), major adverse events-free survival rate (62.5% vs 55.6%; p = 0.27) and repeat revascularisation-free rate (84.8% vs 78.0%; p = 0.16) were not significantly different between the two groups. Revascularisation was the most common major adverse events in the JOCRIED participants. Although percutaneous coronary intervention was performed in 8 patients (13%) in the off-pump group and in 14 patients (23%) in the on-pump group (p = 0.23), no patients underwent redo coronary artery bypass grafting. CONCLUSIONS: Off-pump coronary artery bypass grafting provides comparable 15-year outcomes to on-pump coronary artery bypass grafting.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Humanos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Estudios de Seguimiento , Resultado del Tratamiento
6.
Artículo en Inglés | MEDLINE | ID: mdl-35512199

RESUMEN

OBJECTIVES: Coronary artery bypass grafting (CABG) has been reported for coronary artery diseases in patients with Kawasaki disease and coronary artery complications after arterial switch operations for transposition of the great arteries. However, only a few studies have explored this modality for congenital coronary artery anomalies. As congenital coronary artery anomalies, particularly left coronary artery atresia and stenosis, are one of the reasons for sudden death, coronary revascularization is often required in infants and young children. Therefore, we aimed to investigate the outcome of CABG for such anomalies in infants and young children. METHODS: From 2014 to 2018, 3 infants and 2 children (median age: 10 months; range: 6-40 months) with coronary artery anomalies underwent CABG at our hospital. The indications for the procedure included left main coronary artery atresia and stenosis in 2 and 3 patients, respectively. Graft patency was evaluated postoperatively by contrast-enhanced computed tomography or coronary angiography, and postoperative outcomes (including death and cardiac events) were assessed during the follow-up period. RESULTS: No 30-day or in-hospital mortalities were noted. Postoperative examinations revealed patent grafts in all patients. They were discharged without any cardiac complications. Regarding the outcomes at the follow-up period, the graft patency rate was 80.0% (4/5 grafts), with no deaths or cardiac events. CONCLUSIONS: CABG is a useful strategy for coronary revascularization in infants and young children with coronary artery anomalies. Although the mid-term outcomes and patency are satisfactory, careful follow-up is necessary because the long-term outcomes remain unknown.


Asunto(s)
Enfermedad de la Arteria Coronaria , Transposición de los Grandes Vasos , Niño , Preescolar , Constricción Patológica , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Lactante , Resultado del Tratamiento , Grado de Desobstrucción Vascular
7.
Front Surg ; 9: 739743, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35252323

RESUMEN

BACKGROUND: There is currently no subjective, definitive evaluation method for therapeutic indication other than symptoms in aortic regurgitation. Energy loss, a novel parameter of cardiac workload, can be visualized and quantified using echocardiography vector flow mapping. The purpose of the present study was to evaluate whether energy loss in patients with chronic aortic regurgitation can quantify their subjective symptoms more clearly than other conventional metrics. METHODS: We studied 15 patients undergoing elective aortic valve surgery for aortic regurgitation. We divided the patients into symptomatic and asymptomatic groups using their admission records. We analyzed the mean energy loss in one cardiac cycle using transesophageal echocardiography during the preoperative period. The relationships between symptoms, energy loss, and other conventional metrics were statistically analyzed. RESULTS: There were seven and eight patients in the symptomatic and asymptomatic groups, respectively. The mean energy loss of one cardiac cycle was higher in the symptomatic group (121 mW/m [96-184]) than in the asymptomatic group (87 mW/m [80-103]) (p = 0.040), whereas the diastolic diameter was higher in the asymptomatic group (65 mm [59-78]) than in the symptomatic group (57 mm [51-57]) (p = 0.040). There was no significant difference between the symptomatic and asymptomatic groups in terms of other conventional metrics. CONCLUSIONS: An energy loss can quantify patients' subjective symptoms more clearly than other conventional metrics. The small sample size is the primary limitation of our study, further studies assessing larger cohort of patients are warranted to validate our findings.

9.
J Thorac Cardiovasc Surg ; 163(3): 947-959, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32690416

RESUMEN

OBJECTIVES: We assessed the influence of annuloplasty procedures in mitral repair on left ventricular (LV) vortex flow patterns and aortic outflow patterns, and flow energy loss (EL). METHODS: Twenty healthy volunteers and 14 patients who had undergone mitral valve repair were examined using 3-dimensional cine phase-contrast magnetic resonance imaging. A band group included 7 patients with semi-rigid and 2 with flexible partial bands. The ring group included 5 patients with semi-rigid complete rings. LV vortex flow patterns, aortic outflow patterns, EL, and aortic annulus changes during one cardiac cycle were evaluated. RESULTS: Mitral repair induced different vortex flow patterns compared with that of healthy volunteers. The vortex beneath the anterior mitral leaflet with semi-rigid devices was double-stranded in early diastole, and it was single-stranded with flexible bands with a large shift toward the apex during diastole. LVEL in patients who underwent mitral repair (0.84 ± 0.42 mW) was greater than that in healthy volunteers (0.47 ± 0.10 mW). Complete rings disturbed aortic outflow patterns, with EL distribution changes. Smaller devices relative to patient body size disturbed LV flow patterns and caused high EL. No significant relationship was found between indexed ring orifice area and transmitral mean pressure gradient (r = -0.25, P = .414), but a negative relationship exists between indexed ring orifice area and LVEL (r = -0.84, P < .001). CONCLUSIONS: Mitral repair, especially with relatively small annuloplasty rings, induced abnormal LV flow patterns and EL elevation, which have the potential to be a novel hemodynamic evaluation method after mitral repair.


Asunto(s)
Aorta/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Función Ventricular Izquierda , Anciano , Aorta/fisiopatología , Estudios de Casos y Controles , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Ventrículos Cardíacos/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
10.
J Artif Organs ; 25(1): 82-85, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33945039

RESUMEN

A 72-year-old woman presented with exertional dyspnea. Echocardiography revealed severe mitral valve stenosis; therefore, mitral valve replacement was performed using a bioprosthetic valve. However, left ventricular wall rupture occurred following mitral valve replacement. Under re-cardiac arrest, we found a left ventricular tear under the posterior annulus of the mitral valve. We repaired the left ventricular muscle using a bovine pericardial patch and implanted a bioprosthetic valve again. Postoperatively, we implanted an Impella 5.0 heart pump through the right axillary artery to ensure left ventricular wall unloading. Systemic blood flow depended almost completely on mechanical circulatory assistance until postoperative day 3. After the fourth postoperative day, we started weaning the patient from Impella 5.0. Finally, it was completely discontinued on the sixth postoperative day. After that, the patient's condition was stable, and she was discharged 44 days postoperatively. Impella 5.0 is a potentially beneficial device for left ventricular unloading in patients with left ventricular wall rupture following mitral valve replacement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Rotura Septal Ventricular , Anciano , Animales , Bovinos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Rotura Septal Ventricular/cirugía
11.
J Nucl Cardiol ; 29(5): 2652-2663, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34561849

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) can rapidly improve cardiac sympathetic nervous function (CSNF) within 2 weeks in patients with aortic stenosis (AS). However, whether such short-term improvements will be sustained thereafter remains unclear. METHODS: Patients with severe AS who underwent TAVR between October 2017 and June 2019 were enrolled in this single-center, prospective, observational study. 123I-meta-iodobenzylguanidine imaging was performed at baseline, within 2 weeks after TAVR, and at 6 to 12 months post-TAVR to evaluate the heart-mediastinum ratio (H/M) and washout rate. RESULTS: Of 183 consecutive patients, 75 (19 men; median age: 86 years) were evaluated. The late H/M significantly improved within 2 weeks after TAVR (P = .041) and further improved over 6 to 12 months after TAVR (P = .041). Multivariate analysis revealed that the baseline mean aortic valve pressure gradient (mPG) was an independent predictor of mid-term improvement in the late H/M (> 0.1) (P = .037). Patients with a high baseline mPG (≥ 58 mmHg) exhibited a significantly greater increase in the late H/M than those with a low baseline mPG (< 42 mmHg) (0.24 vs 0.01; P = .029). CONCLUSION: CSNF demonstrated sustained improvement from within 2 weeks after TAVR until 6 to 12 months later. Such improvement was related to baseline hemodynamic AS severity.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , 3-Yodobencilguanidina , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Radioisótopos de Yodo , Masculino , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
12.
Ann Thorac Surg ; 114(1): 126-132, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34480894

RESUMEN

BACKGROUND: The reduction in exercise capacity after mitral valve repair (MVr) for severe degenerative mitral regurgitation is an unsolved issue. This study aimed to evaluate hemodynamics after MVr using a partial semirigid band during exercise stress echocardiography and to identify predictive factors for achieving better exercise capacity after MVr. METHODS: We retrospectively analyzed 48 patients using exercise stress echocardiography within 5 years of having undergone MVr using a partial semirigid band between 2013 and 2019. Values of maximal workload were converted into numbers of metabolic equivalents (METs) achieved for each patient. Age and sex expected METs (eMETs) were obtained, and percent eMETs (%eMETs [achieved METs / eMETs × 100]) were calculated. Multivariable linear regression analysis was used to identify the determinants of %eMETs. RESULTS: Only one third of patients achieved eMETs. Significant determinants of %eMETs were age at exercise stress echocardiography (ß coefficient 0.64; 95% confidence interval, 0.31 to 0.96; P < .001), female sex (ß coefficient 16.9; 95% confidence interval, 8.58 to 25.17; P < .001), and larger indexed device size (device size/body surface area; ß coefficient 4.10; 95% confidence interval, 1.74 to 6.46; P = .001). Receiver-operating characteristic curve analysis revealed that a cutoff value of 19.5 mm/m2 or greater indexed device size was optimal for achieving %eMETs greater than 100%, with a sensitivity and specificity of 87% and 79%, respectively. CONCLUSIONS: Patients with larger indexed device size achieved greater exercise capacity after MVr using a partial semirigid band. Preoperative evaluation to decide whether we can use an annuloplasty device larger than 19.5 mm/m2 may be important for patients who intend to exercise with high intensity.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Ecocardiografía de Estrés , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
13.
Gen Thorac Cardiovasc Surg ; 70(6): 531-540, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34800223

RESUMEN

OBJECTIVES: In Japan, off-pump coronary artery bypass (OPCAB) is more common than on-pump coronary artery bypass. Superior early results of OPCAB have been reported; however, long-term results were still unclear. Purpose of this study is to evaluate the clinical outcomes of OPCAB in Japan using Japan Adult Cardiovascular Surgery Database. METHODS: Between 2008 and 2010, 23,633 patients who underwent isolated coronary artery bypass were reported in database. We selected the cases from the hospital with mean annual coronary surgery volume of more than 50. Among the total of 7724 cases at 41 institutions, 2150 (31.2%) on-pump coronary artery bypass (ONCAB) and 5574 (68.8%) OPCAB cases were included. Propensity score (PS) matching was performed using PS developed from patient characteristics and preoperative factors resulting in 2007 cases matched pairs. Long-term follow-up data on patients' mortality and stroke were collected. RESULTS: In-hospital mortality was significantly lower in OPCAB (ONCAB 1.1%, OPCAB 0.4% p = 0.01). Stroke was low in OPCAB group (ONCAB 1.7%, OPCAB 0.8%, p = 0.01). There was no statistically significant difference between OPCAB and ONCAB regarding 7-year overall survival (86.1% vs 88.1% respectively), composite outcomes (72.0% vs 73.9% respectively), or cardiac deaths (97.3% vs 97.1% respectively). Subgroup analysis (more than 75 years old) showed a worse trend in OPCAB group. Only in OPCAB group, incomplete revascularization significantly influenced 7-year survival. CONCLUSIONS: OPCAB is associated with early prognostic benefits; however, it might be less favorable outcomes in the long term when patients are older or with incomplete revascularization.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Accidente Cerebrovascular , Anciano , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria Off-Pump/métodos , Humanos , Japón/epidemiología , Puntaje de Propensión , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
15.
Kyobu Geka ; 74(10): 746-751, 2021 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-34548440

RESUMEN

It has been reported that there are some risks of coronary artery graft injury while redo sternotomy was required for valve surgery after coronary artery bypass grafting (CABG). Also it is well known that clinical results after graft injury was poor. For avoiding graft injury, coronary artery graft must be placed away from the sternum at the time of initial CABG. For redo sternotomy, 3-dimensional-computed tomography can be useful. For aortic valve surgery after CABG, treatment of patent in-situ graft have to be discussed. For common practice, dissecting and clamping the patent in-situ graft during cardiac arrest were required. However, there are some reports showing good clinical results with moderate hypothermia, non-dissection and non-clamping graft. Furthermore, less mobidity rate results of transcatheter aortic valve implantation( TAVI) after CABG was reported. For mitral valve surgery after CABG, right mini-thoracotomy was reported as preferred procedure recently. Dissection area could be reduced than re-median sternotomy, although clamping aorta and patent graft were technically difficult. Two procedures were reported such as hypothermia and ventricular fibrillation or normothermia and beating heart. MitraClip procedure can be considered for high risk patients. Newly developed surgical and catheter technique may change the strategy for heart valve disease after CABG.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Puente de Arteria Coronaria , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Esternotomía , Toracotomía
16.
Interact Cardiovasc Thorac Surg ; 33(3): 339-347, 2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-33963389

RESUMEN

OBJECTIVES: It is difficult to estimate the improvement in left ventricular (LV) function after aortic valve replacement (AVR). The present study aimed to evaluate whether energy loss (EL) can predict the postoperative LV function after AVR. METHODS: Nine patients who underwent AVR with a bioprosthetic valve were enrolled in the present study. Porcine prostheses were used in 5 patients and bovine pericardial prostheses were used in 4 patients. The aortic flow pattern was visualized and EL and cardiac output (CO) were measured using 4-dimensional flow magnetic resonance imaging from the LV to the descending aorta; the EL/CO ratio in the extracted area was calculated as total EL/CO ratio. RESULTS: With a porcine valve, a severe helical flow was observed in the ascending aorta during the holosystolic phase. In contrast, with a bovine pericardial valve, straight transvalvular aortic flow was observed in the early systolic phase and 2 large vortical flows occurred on both sides of the greater and lesser curvature of the ascending aorta after the mid-systolic period. The total EL/CO ratio was strongly correlated with LV ejection fraction improvement after AVR (r = 0.74, P = 0.02). CONCLUSIONS: The aortic flow pattern is different between the porcine valve and bovine pericardial valve. The total EL/CO ratio is a valuable tool for evaluating the postoperative LV ejection fraction improvement after AVR. Optimization of total EL/CO ratio would have potential to improve haemodynamic performances after AVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bovinos , Humanos , Volumen Sistólico , Porcinos , Función Ventricular Izquierda
17.
Int J Cardiovasc Imaging ; 37(8): 2573-2575, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33772691

RESUMEN

Computational fluid dynamics (CFD) analysis using computed tomography images can reveal the details of the blood flow in cardiovascular disease. In double aortic arch, it is difficult to assess the hemodynamics because of the strong influence of various anatomical features, such as the angle of the aortic bifurcation. In the present study, we reported that CFD analysis is a valuable method for hemodynamic assessment in patients with double aortic arch.


Asunto(s)
Hidrodinámica , Anillo Vascular , Aorta Torácica/diagnóstico por imagen , Simulación por Computador , Hemodinámica , Humanos , Modelos Cardiovasculares , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
18.
Eur J Cardiothorac Surg ; 60(2): 384-391, 2021 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-33619516

RESUMEN

OBJECTIVES: The actual underlying mechanisms of acute type A aortic dissection (AAAD) are not well understood. The present study aimed to elucidate the mechanism of AAAD using computational fluid dynamics (CFD) analysis. METHODS: We performed CFD analysis using patient-specific computed tomography imaging in 3 healthy control cases and 3 patients with AAAD. From computed tomography images, we made a healthy control model or pre-dissection model for CFD analysis. Pulsatile cardiac flow during one cardiac cycle was simulated, and a three-dimensional flow streamline was visualized to evaluate flow velocity, wall shear stress and oscillatory shear index (OSI). RESULTS: In healthy controls, the transvalvular aortic flow was parallel to the ascending aorta. There was no spotty high OSI area at the ascending aorta. In pre-dissection patients, accelerated transvalvular aortic flow was towards the posterolateral ascending aorta. The vortex flow was observed on the side of the lesser curvature in mid-systole and expanded throughout the entire ascending aorta during diastole. Systolic wall shear stress was high due to the accelerated aortic blood flow on the side of the greater curvature of the ascending aorta. On the side of the lesser curvature, high OSI areas were observed around the vortex flow. In all pre-dissection cases, a spotty high OSI area was in close proximity to the actual primary entry site of the future AAAD. CONCLUSIONS: The pre-onset high OSI area with vortex flow is closely associated with the future primary entry site. Therefore, we can elucidate the mechanism of AAAD with CFD analysis.


Asunto(s)
Disección Aórtica , Hidrodinámica , Disección Aórtica/diagnóstico por imagen , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Simulación por Computador , Hemodinámica , Humanos , Modelos Cardiovasculares , Estrés Mecánico
19.
Ann Thorac Surg ; 112(2): e87-e89, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33482165

RESUMEN

Combined resection of the superior vena cava is sometimes challenging during radical surgery for malignant mediastinal tumors. We report a case of a 21-year-old man with a malignant mediastinal germ cell tumor who underwent surgical resection with superior vena cava reconstruction involving an extrathoracic temporary bypass from the right brachiocephalic vein to the right atrium using a venous return cannula because of left brachiocephalic vein occlusion. This is a convenient and safe optional technique providing an excellent intrathoracic surgical view for temporary superior vena cava bypass in patients with invasive malignant mediastinal tumor associated with venous return through the hemilateral brachiocephalic vein.


Asunto(s)
Cánula , Neoplasias del Mediastino/cirugía , Neoplasias de Células Germinales y Embrionarias/cirugía , Vena Cava Superior/cirugía , Humanos , Masculino , Neoplasias del Mediastino/diagnóstico , Neoplasias de Células Germinales y Embrionarias/diagnóstico , Tomografía Computarizada por Rayos X , Vena Cava Superior/diagnóstico por imagen , Adulto Joven
20.
Interact Cardiovasc Thorac Surg ; 31(5): 611-617, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33137825

RESUMEN

OBJECTIVES: The aim of this study was to elucidate the remodelling of the internal mammary artery (IMA)-left anterior descending artery anastomosis and compare 2 different anastomosis techniques (end-to-side versus side-to-side) using computational fluid dynamics. METHODS: This study included 9 patients. Computed tomography (CT) angiography was performed immediately after coronary artery bypass grafting (CABG) and at 3-6 months later. The computational fluid dynamics models were made using the CT data. The pulsatile 3-dimensional blood flow was achieved with the finite volume method to evaluate the postoperative morphological and haemodynamic changes at the anastomosis in each patient. Flow velocity distribution, wall shear stress (WSS) and its fluctuation oscillatory shear index were measured. RESULTS: No early or mid-term graft occlusion was observed in the study series. In the side-to-side anastomosis, pouch formation at the distal end of IMA caused a vortex flow with low WSS immediately after CABG. However, at 3-6 months after surgery, this pouch disappeared. As a result, the laminar straight flow with uniform WSS distribution was achieved inside the anastomosis. In the end-to-side anastomosis, the anastomosis shape was remodelled, resulting in a laminar flow pattern with uniform WSS distribution. A patchy high oscillatory shear index was detected at the IMA wall on the top of anastomosis in either anastomosis techniques immediately after the surgery, but it disappeared at 3-6 months after surgery. CONCLUSIONS: Regardless of the anastomosis technique used, a successful remodelling of the IMA-left anterior descending artery anastomosis shape was achieved a few months after surgery, resulting in a straightforward flow streamline, with uniform WSS distribution and minimal oscillatory shear index.


Asunto(s)
Vasos Coronarios/fisiopatología , Anastomosis Interna Mamario-Coronaria/métodos , Arterias Mamarias/fisiopatología , Anciano , Anciano de 80 o más Años , Anastomosis Quirúrgica/métodos , Angiografía por Tomografía Computarizada , Vasos Coronarios/cirugía , Hemodinámica , Humanos , Hidrodinámica , Masculino , Arterias Mamarias/cirugía , Persona de Mediana Edad , Modelación Específica para el Paciente , Flujo Pulsátil/fisiología , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...