Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur Heart J Case Rep ; 8(1): ytad641, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38249112

RESUMEN

Background: Deviations from usual coronary artery anatomy are well documented. The left circumflex artery (LCx) arising from the pulmonary artery is an example of one such deviation which is rarely seen. We present the case of a 26-year-old male with this coronary artery distribution presenting with an episode of ventricular flutter with late gadolinium enhancement and pluri-morphological ventricular arrhythmias. Case summary: A 26-year-old male with a history of cardiac surgery presented to his local hospital with an episode of symptomatic broad-complex tachycardia (BCT). It failed to revert to sinus rhythm following intravenous beta-blockers and amiodarone and required external cardioversion. Subsequently, the patient developed a aspiration pneumonia requiring ICU admission, after which he was transferred to our institute for ongoing cardiac management. Cardiac computed tomography CTA and coronary angiography revealed that the LCx was found to originate from the pulmonary artery. He underwent insertion of a subcutaneous pacemaker and was subsequently discharged. Despite the potential for steal syndrome of viable coronary territories. Multidisciplinary team discussion determined him to be fit for conservative management and not for surgical correction of his anomalous coronary artery anatomy. Discussion: Aberrant coronary artery anatomy can lead to diverse outcomes for patients in terms of both morbidity and mortality. The need for surgery in these situations varies on a case-by-case basis and little research exists to guide decision-making for healthcare professionals. As such there is a need for further study both to guide treatment and to ensure high-quality outcomes for patients with this condition.

2.
Cardiol Res ; 14(4): 268-278, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37559712

RESUMEN

Background: Low voltage areas (LVAs) have been proposed as surrogate markers for left atrial (LA) scar. Correlation between voltages in sinus rhythm (SR) and atrial fibrillation (AF) have previously been measured via point-by-point analysis. We sought to compare LA voltage composition measured in SR to AF, utilizing a high-density automated voltage histogram analysis (VHA) tool in those undergoing pulmonary vein isolation (PVI) for persistent AF (PeAF). Methods: We retrospectively analyzed patients with PeAF undergoing de novo PVI. Maps required ≥ 1,000 voltage points in each rhythm and had a standardized procedure (mapped in AF then remapped in SR post-PVI). We created six anatomical segments (AS) from each map: anterior, posterior, roof, floor, septal and lateral AS. These were analyzed by VHA, categorizing atrial LVAs into 10 voltage aliquots 0 - 0.5 mV. Data were analyzed using SPSS v.26. Results: We acquired 58,342 voltage points (n = 10 patients, mean age: 67 ± 13 years, three females). LVA burdens of ≤ 0.2 mV, designated as "severe LVAs", were comparable between most AS (except on the posterior wall) with good correlation. Mapped voltages between the ranges of 0.21 and 0.5 mV were labeled as "diseased LA tissue", and these were found significantly more in AF than SR. Significant differences were seen on the roof, anterior, posterior, and lateral AS. Conclusions: Diseased LA tissue (0.21 - 0.5 mV) burden is significantly higher in AF than SR, mainly in the anterior, roof, lateral, and posterior wall. LA "severe LVA" (≤ 0.2 mV) burden is comparable in both rhythms, except with respect to the posterior wall. Our findings suggest that mapping rhythm has less effect on the LA with voltages < 0.2 mV than 0.2 - 0.5 mV across all anatomical regions, excluding the posterior wall.

3.
Europace ; 25(4): 1345-1351, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36891772

RESUMEN

AIMS: Incorporating a steerable sheath that can be visualized using an electroanatomical mapping (EAM) system may allow for more efficient mapping and catheter placement, while reducing radiation exposure, during ablation procedures for atrial fibrillation (AF). This study evaluated fluoroscopy usage and procedure times when a visualizable steerable sheath was used compared with a non-visualizable steerable sheath for catheter ablation for AF. METHODS AND RESULTS: In this retrospective, observational, single-centre study, patients underwent catheter ablation for AF using a steerable sheath that is visualizable using the CARTO EAM (VIZIGO; n = 57) or a non-visualizable steerable sheath (n = 34). The acute procedural success rate was 100%, with no acute complications in either group. Use of the visualizable sheath vs. the non-visualizable sheath was associated with a significantly shorter fluoroscopy time [median (first quartile, third quartile), 3.4 (2.1, 5.4) vs. 5.8 (3.8, 8.6) min; P = 0.003], significantly lower fluoroscopy dose [10.0 (5.0, 20.0) vs. 18.5 (12.3, 34.0) mGy; P = 0.015], and significantly lower dose area product [93.0 (48.0, 197.9) vs. 182.2 (124.5, 355.0) µGy·m2; P = 0.017] but with a significantly longer mapping time [12.0 (9.0, 15.0) vs. 9.0 (7.0, 11.0) min; P = 0.004]. There was no significant difference between the visualizable and non-visualizable sheaths in skin-to-skin time [72.0 (60.0, 82.0) vs. 72.0 (55.5, 80.8) min; P = 0.623]. CONCLUSION: In this retrospective study, use of a visualizable steerable sheath for catheter ablation of AF significantly reduced radiation exposure vs. a non-visualizable steerable sheath. Although mapping time was longer with the visualizable sheath, the overall procedure time was not increased.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Exposición a la Radiación , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía/métodos
4.
J Interv Card Electrophysiol ; 66(2): 445-453, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35997848

RESUMEN

BACKGROUND: Very high power short duration (vHPSD) radiofrequency ablation (RFA) may reduce ablation times and improve patient tolerability, permitting pulmonary vein isolation (PVI) under mild conscious sedation (mCS) and promoting same day discharge (SDD). METHODS: First, a retrospective feasibility study was performed at 2 tertiary cardiac centres in the UK. Consecutive cases of first-time PVI using vHPSD ablation with 90 W lesions for up to 4 s were compared against cases performed using standard RF (sRF) and cryoballoon (Cryo) therapy. Subsequently, a prospective study of patients who had vHPSD or Cryo exclusively under mCS was undertaken. Questionnaires based on Likert and visual analogue scales (VAS) were used to measure anxiety, discomfort and pain. RESULTS: In total, 182 patients (59 vHPSD, 62 sRF and 61 Cryo) were included in the retrospective study, with 53 (90%) of vHPSD cases successfully performed under mCS. PVI ablation time in the vHPSD group (5.8 ± 1.7 min) was shorter than for sRF (16.5 ± 6.3 min, p < 0.001) and Cryo (17.5 ± 5.9 min, p < 0.001). Fifty-one vHPSD and 52 Cryo patients were included in the prospective study. PVI ablation time in the vHPSD group was shorter than for the Cryo group (6.4 ± 2.9 min vs 17.9 ± 5.7 min, p < 0.001), but overall procedure duration was longer (121 ± 39 min vs 95 ± 20 min, p < 0.001). There were no differences in the patient experience of anxiety, discomfort or pain. SDD rates were the same in both groups (61% vs 67%, p = 0.49). CONCLUSIONS: vHPSD RFA for PVI can be performed under mCS to achieve SDD rates comparable to cryoablation, without compromising patient experience.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Ablación por Radiofrecuencia , Humanos , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Sedación Consciente , Resultado del Tratamiento , Evaluación del Resultado de la Atención al Paciente , Venas Pulmonares/cirugía
5.
Cardiol Res ; 13(2): 97-103, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35465080

RESUMEN

Background: Ablation index (AI) is a novel catheter-based parameter that has improved the outcome and safety of radiofrequency (RF) ablation of pulmonary vein isolations (PVIs). This index incorporates contact force (CF) (g), time (s), and power (W) parameters. The role of AI in redo ablations for persistent atrial fibrillation (peAF) has not been fully investigated. Hence, the impact of AI on the success of the redo PVI during the short-term follow-up period is the aim of this study. Methods: A retrospective analysis of 39 consecutive patients who underwent redo PVI ablations for peAF was carried out between January 2016 and December 2018. Target values for AI were 500 - 550 for anterior and roof and 400 - 380 for posterior and inferior regions. We compared outcomes between AI-guided and catheter CF ablations (i.e., forced time integral (FTI) of more than 400 g/s) during a follow-up of 24 months. Results: Pulmonary vein reconnections at redo procedure were similar in both groups (P = 0.1). AF free burden period was non-significant (mean 15.53 ± 2.4 months in AI group vs. 15.22 ± 1.9 months in CF group, P = 0.79) at 24 months. The AI group demonstrated greater numbers of patients for whom anti-arrhythmic therapy could be de-escalated over 1 year (n = 11 (65%) in AI vs. n = 6 (27%) in CF, P = 0.02). Fewer patients underwent escalation of their anti-arrhythmic therapy (n = 2 (12%) in AI vs. n = 7 (32%) in CF, P = 0.15). The AI group trended towards a shorter procedure time (111.6 ± 27 min) compared to the CF group (133 ± 40 min) (P = 0.06). Other procedural details were comparable. Conclusion: Redo PVI interventions using AI lead to a significant de-escalation in medication during follow-up. Procedure time and radiation dose using AI tends to be shorter. Both techniques are safe with minimal complications.

6.
Europace ; 23(6): 878-886, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33693677

RESUMEN

AIMS: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. METHODS AND RESULTS: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35-40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35-40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions (n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35-40 W groups, respectively (P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). CONCLUSION: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Benchmarking , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
7.
Eur Heart J Case Rep ; 5(3): ytab082, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33718770

RESUMEN

BACKGROUND: Takotsubo cardiomyopathy is a variant of acute coronary syndrome with characteristic acute left ventricular apical ballooning. Uncommonly, there can be associated left ventricular outflow tract (LVOT) obstruction causing cardiogenic shock refractory to inotropic support. The use of afterload-reducing mechanical support such as intra-aortic balloon pump (IABP) counterpulsation is not routinely employed in instances of this kind. CASE SUMMARY: In our case report, we describe a 66-year-old female with acute Takotsubo cardiomyopathy and associated LVOT obstruction which failed to respond to high-dose dobutamine and whose clinical trajectory was worsened by fast atrial fibrillation with rapid ventricular response. Within 24 h of admission, the patient had an IABP placed which rapidly improved her haemodynamics. Two days later, IABP was removed and within 6 days of admission, apical ballooning and LVOT obstruction had fully recovered. CONCLUSION: We recommend early use of mechanical support with IABP counterpulsation to expedite recovery in patients with acute Takotsubo cardiomyopathy with associated LVOT obstruction.

8.
Eur Heart J Case Rep ; 5(2): ytab050, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33615133

RESUMEN

BACKGROUND: Antegradely conducting left lateral accessory pathways are a risk for supraventricular tachycardias and pre-excited atrial fibrillation. Rarely, an anomalous coronary sinus can cause difficulty in locating the pathway. The left circumflex coronary artery and obtuse marginal branches supply the posterolateral left ventricle. We describe a case report of a high-risk accessory pathway associated with an anomalous coronary sinus which, between successive electrophysiology studies, was obliterated by a felicitous acute coronary syndrome in the left circumflex territory. CASE SUMMARY: A 49-year-old male with palpitations and manifest pre-excitation was referred for electrophysiology study. Initial study revealed a high-risk left lateral accessory pathway with antegrade effective refractory period of 240 ms and rapidly conducting pre-excited atrial fibrillation. The coronary sinus could not be cannulated to localize the pathway. Coronary angiography and cardiac computed tomography showed an anomalous coronary sinus emptying into the right atrial free wall and patent coronaries. While awaiting repeat electrophysiology study, the patient suffered an acute coronary syndrome with immediate loss of previously visible pre-excitation on electrocardiogram, and underwent stenting of an occluded marginal branch of the circumflex. Repeat electrophysiology study demonstrated a now low-risk accessory pathway (effective refractory period 390 ms). Since infarction, the patient's palpitations have fully settled with all subsequent electrocardiograms devoid of manifest pre-excitation. DISCUSSION: Left lateral accessory pathways, which can associate with an anomalous coronary sinus, derive from tissue similar to normal ventricular myocardium and are vulnerable to ischaemic insults in the area subtended by the circumflex artery.

9.
J Arrhythm ; 36(4): 685-691, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32782640

RESUMEN

BACKGROUND: Catheter ablation for atrial fibrillation (AF) traditionally requires the use of circular mapping catheter (CMC) for pulmonary vein isolation (PVI). This study aimed to assess the feasibility and effectiveness of a CMC-free approach for AF ablation performed by a contiguous optimized (CLOSE) ablation protocol. METHODS: A CLOSE-guided and CMC-free PVI protocol with a single transseptal puncture was attempted in 67 patients with AF. Left atrial (LA) CARTO voltage mapping was performed with the ablation catheter pre- and postablation to demonstrate entry block into the pulmonary veins, and pacing maneuvers were used to confirm exit block. RESULTS: The CMC-free approach was successful in achieving PVI in 66 (98.5%) cases, with procedure time of 148 ± 32 minutes, ablation time of 27.5 ± 5.7 minutes, and fluoroscopy time of 7.8 ± 1.0 minutes. First-pass PVI was seen in 58(86.5%) patients, and pacing maneuvers successfully identified the residual gap in eight of the other nine cases. No complication was observed. At 12 months follow-up, 60 (89.6%) patients remained free from AF. The CMC-free approach resulted in a cost saving of £47,190. CONCLUSION: A CMC-free CLOSE-guided PVI approach is feasible, safe, and cost-saving, and is associated with excellent clinical outcomes at 1 year.

10.
Int J Qual Health Care ; 31(3): 191-198, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29924325

RESUMEN

OBJECTIVE: In this study, we aim to describe the post-sepsis syndrome from the perspective of the sepsis survivors. DESIGN AND SETTING: The study is a prospective, observational online international survey. PARTICIPANTS: Sepsis survivors enrolled via social media from 13 September 2014 to 13 September 2016. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Physiologic, physical and psychological function post-sepsis; and patient satisfaction with sepsis-centered care. RESULTS: 1731 completed surveys from 41 countries were analyzed, with 79.9% female respondents, age 47.6 ± 14.4 years. The majority of respondents (47.8%) had sepsis within the last year. Survivors reported an increase in sensory, integumentary, digestive, breathing, chest pain, kidney and musculoskeletal problems after sepsis (all P-value <0.0001). Physical functions such as daily chores, running errands, spelling, reading and reduced libido posed increased difficulty (all P-value <0.0001). Within 7 days prior to completing the survey, the survivors reported varying degrees of anxiety, depression, fatigue and sleep disturbance. Sepsis survivors reported dissatisfaction with a number of hospital support services, with up to 29.3% of respondents stating no social services support was provided for their condition. CONCLUSIONS: Sepsis survivors suffer from a myriad of physiologic, physical and psychological challenges. Survivors overall reveal dissatisfaction with sepsis-related care, suggesting areas for improvement both in-hospital and post-discharge.


Asunto(s)
Actividades Cotidianas , Salud Mental , Sepsis/complicaciones , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente/estadística & datos numéricos , Estudios Prospectivos , Sepsis/psicología , Sepsis/rehabilitación , Servicio Social/estadística & datos numéricos , Estrés Psicológico , Encuestas y Cuestionarios , Sobrevivientes/estadística & datos numéricos
11.
Ir J Med Sci ; 188(1): 101-108, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29860595

RESUMEN

BACKGROUND: Non-vitamin K antagonist oral anticoagulants (NOACs) are a major advance for stroke prevention in atrial fibrillation (AF). Use of the vitamin K antagonist (VKA), warfarin, has dropped 40% since 2010 in our institution. There is limited Irish hospital data on NOAC prescribing for stroke prevention. METHOD: Single centre, retrospective observational cohort study of consecutive AF patients at increased risk of stroke and/or awaiting electrical cardioversion. Data on prescribed NOACs from February 2010 till July 2015 was collected from the electronic inpatient record. Appropriateness of prescriptions was based on CHA2DS2-VASC score and accuracy on individual NOAC SPCs. Potential drug interactions and bleeding risk were also quantified. RESULTS: A total of 348 patients AF and increased risk of stroke (CHA2DS2-VASC score > 1 for men and > 2 for women) were studied. Forty-eight percent were female with a mean age 71 ± 18.6 years, 52% of whom were > 75. Mean CHA2DS2-Vasc and HAS-BLED scores were 4.1 ± 1.8 and 1.4 ± 0.8, respectively. Rivaroxaban, dabigatran and apixaban were prescribed to 154 (54.2%), 106 (34.3%) and 41 (13.2%) patients, respectively. 20.4% had inaccurate prescriptions; 92.9% (n = 65) underdosed and 7.1% (n = 5) on inappropriately higher doses. Neither choice of NOAC, age, history of anaemia, previous bleeding or co-prescribed antiplatelets influenced the accuracy of prescription (p = NS), but decreased renal function appeared to do so (p = 0.05). CONCLUSION: Our study highlights significant inaccuracies in NOAC prescribing. Patients commenced on NOACs should be assessed and followed up in a multidisciplinary AF clinic to ensure safe and effective prescribing and stroke prevention.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Prescripción Inadecuada/estadística & datos numéricos , Prescripciones/estadística & datos numéricos , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Dabigatrán/uso terapéutico , Femenino , Humanos , Masculino , Auditoría Médica , Persona de Mediana Edad , Pirazoles/uso terapéutico , Piridonas/uso terapéutico , Estudios Retrospectivos , Rivaroxabán/uso terapéutico
13.
Otolaryngol Head Neck Surg ; 150(5): 827-33, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24515967

RESUMEN

OBJECTIVES: To determine the incidence of vocal cord (VC) paralysis and dysphagia after aortic arch reconstruction, including the Norwood procedure. SETTING: Tertiary children's hospital. STUDY DESIGN: Retrospective cohort. METHODS: Database/chart review of neonates requiring Norwood or arch surgery between January 2005 and December 2012. Demographics, postoperative VC function, dysphagia, need for gastrostomy tube and/or tracheotomy, and long-term follow-up were reviewed. RESULTS: One hundred fifty-one consecutive subjects (96 Norwood, 55 aortic arch) were reviewed. Median age at repair was 9 days (interquartile range [IQR], 7-13) for Norwood and 24 days (IQR, 12-49) for arch reconstruction (P < .001). Documentation of VC motion abnormality was found in 60 of 104 (57.6%) subjects and unavailable in 47 (16 without documentation and 31 who died prior to extubation). There were no significant differences in proportions of documented VC motion (P = .337), dysphagia (P = .987), and VC paralysis (P = .706) between the arch and Norwood groups. Dysphagia was found in 73.5% of Norwood and 69.2% of arch subjects who had documented VC paralysis. Even without unilateral VC paralysis (UVCP), dysphagia was present (56% Norwood, 61% arch). Overall, 120 of 151 (79.5%) required feeding evaluation and a modified feeding regimen. Gastrostomy was required in 31% of Norwood and 23.6% of arch reconstruction overall. To date, mortality in this series is 55 of 151 (36.4%) patients. Of those with VC paralysis, only 23 (22%) had any otolaryngology follow-up after discharge from surgery. More than 75% with VC paralysis with follow-up after hospital discharge had persistent VC paralysis 11.5 months after diagnosis. CONCLUSION: There is high incidence of UVCP and dysphagia after Norwood and arch reconstruction. Dysphagia was highly prevalent in both groups even without UVCP. Preoperative discussion on vocal cord function and dysphagia should be considered.


Asunto(s)
Aorta Torácica/cirugía , Trastornos de Deglución/etiología , Procedimientos de Norwood , Procedimientos de Cirugía Plástica/métodos , Complicaciones Posoperatorias/etiología , Parálisis de los Pliegues Vocales/etiología , Femenino , Gastrostomía , Humanos , Recién Nacido , Masculino , Apoyo Nutricional/métodos , Estudios Retrospectivos , Traqueostomía , Resultado del Tratamiento
14.
Nat Mater ; 2(9): 616-21, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12923529

RESUMEN

Blends of conjugated polymers are frequently used as the active semiconducting layer in light-emitting diodes and photovoltaic devices. Here we report the use of scanning near-field optical microscopy, scanning force microscopy and nuclear-reaction analysis to study the structure of a thin film of a phase-separated blend of two conjugated polymers prepared by spin-casting. We show that in addition to the well-known micrometre-scale phase-separated morphology of the blend, one of the polymers preferentially wets the surface and forms a 10-nm-thick, partially crystallized wetting layer. Using near-field microscopy we identify unexpected changes in the fluorescence emission from the blend that occurs in a 300-nm-wide band located at the interface between the different phase-separated domains. Our measurements provide an insight into the complex structure of phase-separated conjugated-polymer thin films. Characterizing and controlling the properties of the interfaces in such films will be critical in the further development of efficient optoelectronic devices.


Asunto(s)
Cristalización/métodos , Cristalografía/métodos , Fluorenos/química , Nanotecnología/métodos , Espectrometría de Fluorescencia/métodos , Tiadiazoles/química , Electroquímica/instrumentación , Electroquímica/métodos , Fluorescencia , Nanotecnología/instrumentación , Fotoquímica/instrumentación , Fotoquímica/métodos , Polímeros/química , Estadística como Asunto , Relación Estructura-Actividad , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...