Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Heliyon ; 10(18): e37960, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39323796

RESUMEN

Relay protection and emergency automation is an integral part of electric power systems. The algorithms of the relay protection and emergency automation are based on the use of analysis of the parameters of the electrical mode - current and voltage - obtained from current and voltage instrument transformers. As a rule, these transformers operate on the basis of the laws of electromagnetism. Operational experience shows that the magnetic core of current transformers under fault conditions can be saturated. As a result, the shape of the measured current is distorted which can lead to false operation of the relay protection and emergency automation system. In this paper a comparative analysis of the existing methods is presented. The advantages and disadvantages of them are described. The problem of current transformer core saturation is reduced to a regression problem. To solve the problem an artificial neural networks-based method is proposed. Computational experiments for both proposed and existing methods are performed. The results of experiments show that the efficiency of the proposed method is 1.25 times higher relative to the most effective existing method. The method of re-scaling data at real-time work applied to the restoration of the distorted shape of current is proposed.

2.
Bioengineering (Basel) ; 10(7)2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37508878

RESUMEN

Remote Photoplethysmography (rPPG) is a contactless method that enables the detection of various physiological signals from facial videos. rPPG utilizes a digital camera to detect subtle changes in skin color to measure vital signs such as heart rate variability (HRV), an important biomarker related to the autonomous nervous system. This paper presents a novel contactless HRV extraction algorithm, WaveHRV, based on the Wavelet Scattering Transform technique, followed by adaptive bandpass filtering and inter-beat-interval (IBI) analysis. Furthermore, a novel method is introduced to preprocess noisy contact-based PPG signals. WaveHRV is bench-marked against existing algorithms and public datasets. Our results show that WaveHRV is promising and achieves the lowest mean absolute error (MAE) of 10.5 ms and 6.15 ms for RMSSD and SDNN on the UBFCrPPG dataset.

3.
Sensors (Basel) ; 21(21)2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34770580

RESUMEN

Current measurements from electromagnetic current transformers are essential for the construction of secondary circuit systems, including for protection systems. Magnetic core of these transformers are at risk of saturation, as a result of which maloperation of protection algorithms can possibly occur. The paper considers methods for recovering a current signal in the saturation mode of current transformers. The advantages and disadvantages of methods for detecting the occurrence of current transformers core saturation are described. A comparative analysis of mathematical methods for recovering a current signal is given, their approbation was carried out, and the most promising of them was revealed. The stability and sensitivity of recovery methods were tested by adding white noise to the measured signal and taking into account the initial flux density (remanent magnetization) in the current transformers core. Their comparison is given on the basis of angular, magnitude, and total errors at a given simulation interval.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...