Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomed Opt Express ; 14(6): 2645-2657, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37342721

RESUMEN

The phenomenon of retinal vein pulsation is still not a deeply understood topic in retinal hemodynamics. In this paper, we present a novel hardware solution for recording retinal video sequences and physiological signals using synchronized acquisition, we apply the photoplethysmographic principle for the semi-automatic processing of retinal video sequences and we analyse the timing of the vein collapse within the cardiac cycle using of an electrocardiographic signal (ECG). We measured the left eyes of healthy subjects and determined the phases of vein collapse within the cardiac cycle using a principle of photoplethysmography and a semi-automatic image processing approach. We found that the time to vein collapse (Tvc) is between 60 ms and 220 ms after the R-wave of the ECG signal, which corresponds to 6% to 28% of the cardiac cycle. We found no correlation between Tvc and the duration of the cardiac cycle and only a weak correlation between Tvc and age (0.37, p = 0.20), and Tvc and systolic blood pressure (-0.33, p = 0.25). The Tvc values are comparable to those of previously published papers and can contribute to the studies that analyze vein pulsations.

2.
PLoS One ; 18(5): e0284743, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37146019

RESUMEN

The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (p<0.001) reflects the highest PAA-RNFL correspondence in the temporal semi-circular area, compared to the lowest value in the nasal semi-circular area (Rnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Fibras Nerviosas , Células Ganglionares de la Retina , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos
3.
Front Med (Lausanne) ; 10: 1125154, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37007778

RESUMEN

Based on our previously developed mono-color video-ophthalmoscope a multi-color video-ophthalmoscope was developed. Using narrow band transmission filters, this instrument allows to measure the pulsatile cardiac cycle induced blood volume changes in the human retina for any wavelength in the sensitivity range of the used CMOS-camera. In this key experiment, video sequences (8 s, 25 fps, 200 frames) of the optic nerve head (ONH) were acquire for seven wavelengths between 475 nm and 677 nm one after the other. After image registration of all frames of each video sequence (to compensate for eye movements) and trend correction (to compensate for slow intensity changes), the amplitude of the cardiac cycle induced light intensity changes (pulsatile absorption amplitude PAA) can be calculated for all seven wavelengths. The results confirmed that the spectral distribution of PAA (λ) follows the distribution of the light absorption of blood. The measured values correspond to the absorption of a thin blood layer of about 0.5 µm thickness.

4.
J Biophotonics ; 15(9): e202200094, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35604408

RESUMEN

Multispectral imaging is used in various applications including astronomy, industry and agriculture. In retinal imaging, the single-shot multispectral image stack is typically acquired and analyzed. This multispectral analysis can provide information on various structural or metabolic properties. This paper describes the multispectral improvement of a video-ophthalmoscope, which can acquire retinal video sequences of the optic nerve head and peripapillary area using various spectral light illumination. The description of the multispectral video imaging is provided and several applications are described. These applications include multispectral retinal photoplethysmography, visualization of spontaneous vein pulsation and multispectral RGB image generation.


Asunto(s)
Iluminación , Disco Óptico , Tecnología de Fibra Óptica , Oftalmoscopios , Oftalmoscopía/métodos , Disco Óptico/diagnóstico por imagen , Retina/diagnóstico por imagen , Retina/fisiología
5.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 483-494, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32960321

RESUMEN

PURPOSE: To measure parameters of the cardiac cycle-induced pulsatile light absorption signal (plethysmography signal) of the optic nerve head (ONH) and to compare parameters between normal subjects and patients with different stages of glaucoma. PATIENTS AND METHODS: A recently developed video ophthalmoscope was used to acquire short video sequences (10 s) of the ONH. After image registration and trend correction, the pulsatile changing light absorption at the ONH tissue (excluding large vessels) was calculated. The changing light absorption depends on the pulsatile changing blood volume. Various parameters, including peak amplitude, steepness, time-to-peak, full width at half maximum (FWHM), and pulse duration, were calculated for averaged individual pulses (heartbeats) of the plethysmography signal. This method was applied to 19 healthy control subjects and 91 subjects with ocular hypertension, as well as different stages of primary open-angle glaucoma (17 subjects with ocular hypertension, 24 with preperimetric glaucoma, and 50 with perimetric glaucoma). RESULTS: Compared to the normal subjects, significant reductions (p < 0.001) in peak amplitude and steepness were observed in the group of perimetric glaucoma patients, but no significant difference was found for time-to-peak, FWHM, and pulse duration. Peak amplitude and steepness showed high correlations with RNFL thickness (p < 0.001). CONCLUSIONS: The presented low-cost video-ophthalmoscope permits measurement of the plethysmographic signal of the ONH tissue and calculation of different blood flow-related parameters. The reduced values of the amplitude and steepness parameters in perimetric glaucoma patients suggest decreased ONH perfusion and blood volume. This outcome is in agreement with results from other studies using OCT angiography and laser speckle flowgraphy, which confirm reduced capillary density in these patients. Registration site: www.clinicaltrials.gov , Trial registration number: NCT00494923.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Disco Óptico , Glaucoma/diagnóstico , Humanos , Presión Intraocular , Pletismografía , Tomografía de Coherencia Óptica , Campos Visuales
6.
Biomed Opt Express ; 12(12): 7405-7421, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35003842

RESUMEN

Assessment of retinal blood flow inside the optic nerve head (ONH) and the peripapillary area is an important task in retinal imaging. For this purpose, an experimental binocular video ophthalmoscope that acquires precisely synchronized video sequences of the optic nerve head and peripapillary area from both eyes has been previously developed. It enables to compare specific characteristics of both eyes and efficiently detect the eye asymmetry. In this paper, we describe a novel methodology for the analysis of acquired video data using a photoplethysmographic approach. We describe and calculate the pulsatile attenuation amplitude (PAA) spatial map, which quantifies the maximum relative change of blood volume during a cardiac cycle using a frequency domain approach. We also describe in detail the origin of PAA maps from the fundamental (the first) and the second harmonic component of the pulsatile signal, and we compare the results obtained by time-based and frequency-based approaches. In several cases, we show the advantages and possibilities of this device and the appropriate image analysis approach - fast measurement and comparison of blood flow characteristics of both eyes at a glance, the robustness of this approach, and the possibility of easy detection of asymmetry.

7.
IEEE Trans Med Imaging ; 40(3): 852-864, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33232226

RESUMEN

Dynamic optical imaging of retinal hemodynamics is a rapidly evolving technique in vision and eye-disease research. Video-recording, which may be readily accessible and affordable, captures several distinct functional phenomena such as the spontaneous venous pulsations (SVP) of central vein or local arterial blood supply etc. These phenomena display specific dynamic patterns that have been detected using manual or semi-automated methods. We propose a pioneering concept in retina video-imaging using blind source separation (BSS) serving as an automated localizer of distinct areas with temporally synchronized hemodynamics. The feasibility of BSS techniques (such as spatial principal component analysis and spatial independent component analysis) and K-means based post-processing method were successfully tested on the monocular and binocular video-ophthalmoscopic (VO) recordings of optic nerve head (ONH) in healthy subjects. BSSs automatically detected three spatially distinct reproducible areas, i.e. SVP, optic cup pulsations (OCP) that included areas of larger vessels in the nasal part of ONH, and "other" pulsations (OP). The K-means post-processing reduced a spike noise from the patterns' dynamics while high linear dependence between the non-filtered and post-processed signals was preserved. Although the dynamics of all patterns were heart rate related, the morphology analysis demonstrated significant phase shifts between SVP and OCP, and between SVP and OP. In addition, we detected low frequency oscillations that may represent respiratory-induced effects in time-courses of the VO recordings.


Asunto(s)
Disco Óptico , Voluntarios Sanos , Humanos , Oftalmoscopía , Disco Óptico/diagnóstico por imagen , Retina , Grabación en Video
8.
Int J Pediatr Otorhinolaryngol ; 126: 109614, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31377401

RESUMEN

OBJECTIVES: To evaluate the hearing benefit, advantages, and disadvantages in a series of children using a new, nonimplantable, pressure-free, adhesive bone conduction hearing aid. METHODS: Seventeen children were included in the study. 5 children suffered from bilateral conductive hearing loss (CHL), 6 children with unilateral CHL and 6 children with unilateral sensorineural hearing loss. An audiological tests were provide. Additionally, sound quality (SSQ10) and quality of life (AQoL-6D) were assessed using questionnaires. RESULTS: The average value of speech audiometry with bubble noise in children with SNHL is 21.33 (±5.72) dB HL with the device and 27.67 (±4.59) dB HL without the device, which is a statistically significant gain (p = 0.027). The analysis showed the average value of hearing threshold in sound field in the group of children with CHL supported 20.23 (±16.84) dB HL and not supported 33.52 (±27.27) by the hearing aid for bone conduction, which i a statistically significant gain (p = 0.008). The average value of speech audiometry is 23.45 (±14.45) dB HL with the device and 37.27 (±26.65) dB HL without the device, which is a statistically significant gain (p = 0.012). The average value of speech audiometry with bubble noise is 30.55 (±10.03) dB HL with the device and 45.45 (±18.41) dB HL without the device, which is a statistically significant gain (p = 0.008). No patient referred pain or irritation. CONCLUSION: This new device for bone conduction show a hearing benefit for a paediatric patient, without any concomitant aesthetic and other complications.


Asunto(s)
Conducción Ósea , Audífonos , Pérdida Auditiva Conductiva/rehabilitación , Pérdida Auditiva Sensorineural/rehabilitación , Percepción del Habla , Adhesivos , Adolescente , Audiometría del Habla , Niño , Preescolar , Femenino , Humanos , Masculino , Proyectos Piloto , Calidad de Vida , Encuestas y Cuestionarios
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 4725-4728, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946917

RESUMEN

This paper describes an application of binocular video-ophthalmoscope for binocular eye movement analysis during target fixation. We analyze eye movements during monocular and binocular fixation and the changes in eye position for 73 subjects. We show that the standard deviations of differences between eye shifts for vertical and horizontal movements are higher for binocular fixation with respect to monocular fixation. We also present different examples of eye movement visualization.


Asunto(s)
Movimientos Oculares , Fijación Ocular , Oftalmoscopios , Visión Binocular , Humanos
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 4729-4732, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31946918

RESUMEN

Optical imaging of retinal hemodynamic function is an important part of ophthalmologic research. Development and inventing of imaging devices and data analysis methods are both just in progress. The current study innovatively implements two blind source separation (BSS) techniques (i.e. spatial Principal Component Analysis - sPCA; and spatial Independent Component Analysis - sICA) in application of an automatic detection and segmentation of a distinct Optic Disc (OD) areas with different hemodynamic properties from a simultaneous binocular video-ophthalmoscopic records. Both methods detected 3 different spatial patterns mostly symmetric over both eyes stable and reproducible over investigated participants, i.e. central Spontaneous Vessel Pulsations (SVPs), inner OD intensity pulsations and other OD pulsations. Dynamics of all mentioned patterns has a periodic character with similar main frequency (possibly corresponding to subject-specific heart rate) but shifted phase decreasing patterns' mutual high cross-correlations. The sICA estimates a higher rate of phase shifts than sPCA.


Asunto(s)
Oftalmoscopía , Disco Óptico , Retina/diagnóstico por imagen , Grabación en Video , Humanos , Oftalmoscopios
11.
Biomed Opt Express ; 9(12): 6237-6254, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31065425

RESUMEN

We describe a low-cost, easy to use binocular instrument to acquire retinal video sequences of both eyes simultaneously. After image registration, cardiac cycle-induced pulsatile light attenuation changes can be measured quantitatively with high spatial and temporal resolution. Parameters such as amplitude, pulse form, and time shift between light attenuation changes can be calculated and compared between eye sides. Deviation from inter-eye symmetry can be not only an early sign of beginning eye diseases such as glaucoma but also a sign of pathological changes in the carotid arteries; hence, this method can improve the early detection of pathological changes. Important features compared to existing monocular instruments are a narrow band light source with the wavelength close to the peak of the blood extinction, and a proportional relationship of image intensity and light intensity, which are the main requirements for quantitative evaluation.

12.
Brain Behav ; 7(9): e00799, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28948092

RESUMEN

INTRODUCTION: Metallothioneins (MTs) are a class of ubiquitously occurring low-molecular-weight cysteine- and metal-rich proteins containing sulfur-based metal clusters. MT-3 exhibits neuro-inhibitory activity. The possibility to enhance the expression of MT-3 or protect it from degradation is an attractive therapeutic target, because low levels of MT-3 were found in brains of Alzheimer's disease (AD) patients. OBJECTIVES: The primary objective of this study was to test an enhancement of MT-3 cellular concentration after MT-3 binding treatment, which could prevent MT-3 degradation. METHODS: MTT assay, flow-cytometry, fluorescence microscopy, quantitative real-time polymerase chain reaction, and immunodetection of MT3 were used for analysis of effect of STOCK1N-26544, STOCK1N-26929, and STOCK1N-72593 on immortalized human microglia-SV40 cell line. RESULTS: All three tested compounds enhanced concentration of MT-3 protein in cells and surprisingly also mRNA concentration. IC50 values of tested molecules exceeded about ten times the concentration that was needed for induction of MT-3 expression. The tested compound Benzothiazolone-2 enhanced apoptosis and necrosis, but it was not of severe effect. About 80% of cells were still viable. There was no serious ROS-generation and no severe decrease in mitochondria numbers or stress induced endoplasmic reticulum changes after test treatments. The selected compound showed stable hydrophobic and electrostatic interaction during MT-3 ligand interaction. CONCLUSION: Benzothiazolone-2 compounds significantly enhanced MT-3 protein and mRNA levels. The compounds can be looked upon as one of the probable lead compounds for future drug designing experiments in the treatment of Alzheimer's disease.


Asunto(s)
Enfermedad de Alzheimer/metabolismo , Encéfalo/efectos de los fármacos , Metalotioneína/metabolismo , Microglía/efectos de los fármacos , Apoptosis/efectos de los fármacos , Benzotiazoles/química , Benzotiazoles/farmacología , Encéfalo/metabolismo , Línea Celular , Supervivencia Celular/efectos de los fármacos , Humanos , Microglía/metabolismo , ARN Mensajero/metabolismo , Especies Reactivas de Oxígeno/metabolismo
13.
Biomed Eng Online ; 15(1): 57, 2016 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-27206477

RESUMEN

BACKGROUND: Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. METHODS: Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. RESULTS: The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. CONCLUSION: The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Oftalmoscopios , Retina , Algoritmos , Movimientos Oculares , Humanos , Retina/fisiología , Vasos Retinianos/citología , Relación Señal-Ruido , Grabación de Cinta de Video
14.
Appl Biochem Biotechnol ; 178(6): 1154-66, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26634841

RESUMEN

Artificial neural network based modeling is a generic approach to understand and correlate different complex parameters of biological systems for improving the desired output. In addition, some new inferences can also be predicted in a shorter time with less cost and labor. As terpenoid indole alkaloid pathway in Vinca minor is very less investigated or elucidated, a strategy of elicitation with hydroxylase and acetyltransferase along with incorporation of various precursors from primary shikimate and secoiridoid pools via simultaneous employment of cyclooxygenase inhibitor was performed in the hairy roots of V. minor. This led to the increment in biomass accumulation, total alkaloid concentration, and vincamine production in selected treatments. The resultant experimental values were correlated with algorithm approaches of artificial neural network that assisted in finding the yield of vincamine, alkaloids, and growth kinetics using number of elicits. The inputs were the hydroxylase/acetyltransferase elicitors and cyclooxygenase inhibitor along with various precursors from shikimate and secoiridoid pools and the outputs were growth index (GI), alkaloids, and vincamine. The approach incorporates two MATLAB codes; GRNN and FFBPNN. Growth kinetic studies revealed that shikimate and tryptophan supplementation triggers biomass accumulation (GI = 440.2 to 540.5); while maximum alkaloid (3.7 % dry wt.) and vincamine production (0.017 ± 0.001 % dry wt.) was obtained on supplementation of secologanin along with tryptophan, naproxen, hydrogen peroxide, and acetic anhydride. The study shows that experimental and predicted values strongly correlate each other. The correlation coefficient for growth index (GI), alkaloids, and vincamine was found to be 0.9997, 0.9980, 0.9511 in GRNN and 0.9725, 0.9444, 0.9422 in FFBPNN, respectively. GRNN provided greater similarity between the target and predicted dataset in comparison to FFBPNN. The findings can provide future insights to calculate growth index, alkaloids, and vincamine in combination to different elicits.


Asunto(s)
Alcaloides/biosíntesis , Redes Neurales de la Computación , Raíces de Plantas/metabolismo , Vinca/metabolismo
15.
Artículo en Inglés | MEDLINE | ID: mdl-26737475

RESUMEN

This paper describes a novel methodology for eye fixation measurement using a unique videoophthalmoscope setup and advanced image registration approach. The representation of the eye movements via Poincare plot is also introduced. The properties, limitations and perspective of this methodology are finally discussed.


Asunto(s)
Fijación Ocular , Procesamiento de Imagen Asistido por Computador/métodos , Retina/fisiología , Humanos , Oftalmoscopía
16.
Comput Med Imaging Graph ; 38(6): 508-16, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24906911

RESUMEN

Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning.


Asunto(s)
Color , Glaucoma/patología , Aumento de la Imagen/métodos , Cadenas de Markov , Fibras Nerviosas/patología , Disco Óptico/patología , Fondo de Ojo , Humanos , Distribución Normal , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica
17.
Comput Math Methods Med ; 2013: 134543, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24454526

RESUMEN

The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.


Asunto(s)
Axones/patología , Fondo de Ojo , Células Ganglionares de la Retina/patología , Algoritmos , Color , Entropía , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Fibras Nerviosas , Fotograbar , Valores de Referencia , Análisis de Regresión , Reproducibilidad de los Resultados , Propiedades de Superficie , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...