Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Am J Cardiol ; 133: 126-133, 2020 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-32811652

RESUMEN

Since the diagnosis of cardiac amyloidosis (CA) is often delayed, echocardiographic findings are frequently indicative of advanced cardiomyopathy. We aimed to describe early echocardiographic features in patients subsequently diagnosed with CA. Preamyloid diagnosis echocardiographic studies were screened for structural and functional parameters and stratified according to the pathogenetic subtype (immunoglobulin light-chain [AL] or amyloid transthyretin [ATTR]). Abnormalities were defined based on published guidelines. Our cohort included 75 CA patients of whom 42 (56%) were diagnosed with AL and 33 (44%) with ATTR. Forty-two patients had an earlier echocardiography exam available for review. Patients presented with increased wall thickness (1.3 [interquartile range {IQR} 1.0, 1.5] cm) ≥3 years before the diagnosis of CA and relative wall thickness was increased (0.47 [IQR 0.41, 0.50]) ≥7 years prediagnosis. One to 3 years before CA diagnosis restrictive left ventricular (LV) filling pattern was present in 19% of patients and LV ejection fraction ≤50% was present in 21% of patients. Right ventricular dysfunction was detected concomitantly with disease diagnosis. The echocardiographic phenotype of ATTR versus AL-CA showed increased relative wall thickness (0.74 [IQR 0.62, 0.92] versus 0.62 [IQR 0.54, 0.76], p = 0.004) and LV mass index (144 [IQR 129, 191] versus 115 [IQR 105, 146] g/m2, p = 0.020) and reduced LV ejection fraction (50 [IQR 44, 58] versus (60 [IQR 53, 60]%, p = 0.009) throughout the time course of CA progression, albeit survival time was similar. In conclusion, increased wall thickness and diastolic dysfunction in CA develop over a time course of several years and can be diagnosed in their earlier stages by standard echocardiography.


Asunto(s)
Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/diagnóstico por imagen , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/complicaciones , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Neuropatías Amiloides Familiares/mortalidad , Cardiomiopatías/mortalidad , Progresión de la Enfermedad , Ecocardiografía , Femenino , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/mortalidad , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo
2.
JACC Cardiovasc Interv ; 12(15): 1438-1447, 2019 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-31395213

RESUMEN

OBJECTIVES: To evaluate the long-term (≥2 years) outcomes following transcatheter tricuspid valve repair (TTVr) with the FORMA Transcatheter Tricuspid Valve Repair System (Edwards Lifesciences, Irvine, California). BACKGROUND: Scarce data exist on long-term outcomes following TTVr. METHODS: This multicenter experience included patients with severe tricuspid regurgitation (TR) who underwent TTVr with the FORMA system at 4 centers under a compassionate clinical use program. Data were collected at baseline, 30 days, and 1 year, and yearly thereafter. RESULTS: Nineteen patients (76 ± 9 years of age, 74% women, mean EuroSCORE II [European System for Cardiac Operative Risk Evaluation] 9.2 ± 5.6%) with functional TR were included. Procedural success was achieved in 17 (89%) patients and there were no cases of 30-day mortality. At a median follow-up of 32 (interquartile range: 24 to 36) months, 4 (24%) patients had died (3 from terminal heart failure, 1 from sepsis) and 3 (18%) patients required rehospitalization for heart failure. There was 1 device-related thrombosis and 1 pulmonary embolism, both in the setting of subtherapeutic oral anticoagulation. Less than severe TR was observed at echocardiography in 67% of patients at the 2- to 3-year follow-up. Among 15 successfully implanted patients with at least 24-month follow-up, significant improvements in New York Heart Association functional class (p < 0.001), 6-min walk test (+54 m; p = 0.016) and Kansas City Cardiomyopathy Questionnaire score (+16 points; p = 0.016) were observed, compared with baseline. CONCLUSIONS: TTVr using the FORMA system showed favorable long-term safety profile in high-surgical-risk patients, with sustained functional improvement and acceptable TR reduction up to 3 years.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Canadá , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Ensayos de Uso Compasivo , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
3.
JACC Cardiovasc Interv ; 10(19): 1994-2003, 2017 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-28780036

RESUMEN

OBJECTIVES: This study sought to describe the 1-year experience with the transcatheter FORMA system for severe tricuspid regurgitation (TR). BACKGROUND: Severe TR is associated with significant morbidity and mortality. Novel transcatheter therapies have been recently developed. METHODS: Eighteen patients underwent device implantation at 3 centers in Canada and Switzerland. Baseline characteristics, procedural, 30-day, and 1-year outcomes were prospectively evaluated using multimodality imaging and hemodynamic and clinical assessments. RESULTS: Procedural success was achieved in 16 (89%) patients. Unsuccessful procedures were because of right ventricular perforation requiring open surgery and device dislocation. At 1 year there were no deaths, significant arrhythmias, device infections, or dislocations. Thrombus was observed on 1 device at 4 months and there was 1 rehospitalization for heart failure. Among the 14 patients with successful device implantation and 1-year follow-up, 79% were in New York Heart Association functional class I/II (p < 0.001), the average 6-min walk test increased by 84 m (p = 0.03), and the Kansas City Cardiomyopathy Questionnaire heart failure score improved by 18 points (p = 0.02) compared with baseline. Echocardiography showed a reduction of TR from severe in 17 of 18 (94%) patients at baseline to moderate-severe or less in 11 of 16 patients (69%) by 30 days (p = 0.001) and 6 of 13 patients (46%) by 1 year (p = 0.01). The diameters of the tricuspid annulus and the right ventricle were reduced at 1 year (45.7 ± 4.8 mm to 42.1 ± 4.4 mm, p = 0.004; 54 ± 5.3 mm to 49.9 ± 4.3 mm, p = 0.02, respectively). CONCLUSIONS: Implantation of the FORMA system in high-risk patients with severe TR shows feasibility with a good mid-term safety profile. At 1 year, despite variable success in reducing echocardiographic TR grade, there were significant clinical improvements and reductions in right ventricular dimensions.


Asunto(s)
Prótesis Vascular , Cateterismo Cardíaco/instrumentación , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Canadá , Cateterismo Cardíaco/efectos adversos , Catéteres Cardíacos , Ensayos de Uso Compasivo , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios , Suiza , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...