Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Afr J Lab Med ; 13(1): 2339, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39228898

RESUMEN

Background: HIV testing remains an entry point into HIV care and treatment services. In 2007, Nigeria adopted and implemented a two-test rapid HIV testing algorithm of three HIV rapid test kits, following the sequence: Alere Determine (first test), UnigoldTM (second test), and STAT-PAK® as the tie-breaker. Sub-analysis of the 2018 Nigeria HIV/AIDS Indicator and Impact Survey data showed significant discordance between the first and second tests, necessitating an evaluation of the algorithm. This manuscript highlights lessons learnt from that evaluation. Intervention: A two-phased evaluation method was employed, including abstraction and analysis of retrospective HIV testing data from January 2017 to December 2019 from 24 selected sites supported by the United States President's Emergency Plan for AIDS Relief programme. A prospective evaluation of HIV testing was done among 2895 consecutively enrolled and consented adults, aged 15-64 years, accessing HIV testing services from three selected sites per state across the six geopolitical zones of Nigeria between July 2020 and September 2020. The prospective evaluation was performed both in the field and at the National Reference Laboratory under controlled laboratory conditions. Stakeholder engagements, strategic selection and training of study personnel, and integrated supportive supervision were employed to assure the quality of evaluation procedures and outcomes. Lessons learnt: The algorithm showed higher sensitivity and specificity in the National Reference Laboratory compared with the field. The approaches to quality assurance were integral to the high-quality study outcomes. Recommendations: We recommend comparison of testing algorithms under evaluation against a gold standard. What this study adds: This study provides context-specific considerations in using World Health Organization recommendations to evaluate the Nigerian national HIV rapid testing algorithm.

2.
Am J Trop Med Hyg ; 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39255809

RESUMEN

Congenital transmission of Toxoplasma gondii can occur when a woman becomes infected for the first time during or just before pregnancy. Toxoplasma gondii in the fetus can lead to miscarriage, stillbirth, ocular or neurological abnormalities at birth, or progressive visual, hearing, motor, and cognitive deficiencies. The national seroprevalence of T. gondii infection in Nigeria was previously unknown. The 2018 Nigeria HIV/AIDS Indicator and Impact Survey collected demographic, socioeconomic, and HIV-related data and stored blood specimens with consent for future analysis for other pathogens of public health importance. We evaluated toxoplasmosis seropositivity and risk factors in a sample of 44,269 women of reproductive age (WRA) between 15 and 44 years. The national T. gondii seroprevalence among WRA was 26.8% (95% CI: 25.8-27.7%). We found that WRA from all 36 states and the Federal Capital Territory had T. gondii exposure. Seroprevalence was higher in 25- to 44-year-olds than in 15- to 24-year-olds. A similar proportion of pregnant and nonpregnant women were seropositive. Increased odds of seropositivity were associated with unimproved toilet facilities and drinking water sources, being in a higher wealth quintile, and primary and secondary education compared with no education. Decreased odds of seropositivity were associated with living in an urban area and owning livestock. This study provides the first-ever national seroprevalence estimate for WRA in Nigeria. Although information on known risk factors for toxoplasmosis (e.g., consumption of undercooked meat, cat ownership) was not collected, future studies could further investigate potential risk factors to inform the development of effective toxoplasmosis prevention measures.

3.
Am J Trop Med Hyg ; 110(1): 90-97, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38011731

RESUMEN

The first nationally representative, population-based study of schistosomiasis seroprevalence in Nigeria was conducted using blood samples and risk-factor data collected during the 2018 Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS). Schistosomiasis seroprevalence was estimated by analyzing samples for reactivity to schistosome soluble egg antigen (SEA) in a multiplex bead assay; NAIIS survey data were assessed to identify potential risk factors for seropositivity. The SEA antibody data were available for 31,459 children aged 0 to 14 years. Overall seroprevalence was 17.2% (95% CI: 16.3-18.1%). Seropositive children were identified in every age group, including children < 5 years, and seroprevalence increased with increasing age (P < 0.0001). Several factors were associated with increased odds of seropositivity, including being a boy (odds ratio [OR] = 1.34, 95% CI: 1.24-1.45), living in a rural area (OR = 2.2, 95% CI: 1.9-2.5), and animal ownership (OR = 1.67, 95% CI: 1.52-1.85). Access to improved sanitation and drinking water sources were associated with decreased odds of seropositivity (OR = 0.52, 95% CI: 0.47-0.58 and OR = 0.53, 95% CI: 0.47-0.60, respectively) regardless of whether the child lived in a rural (sanitation: adjusted odds ratio [aOR] = 0.7, 95% CI: 0.6-0.8; drinking water: aOR = 0.7, 95% CI: 0.6-0.8) or urban area (sanitation: aOR = 0.6, 95% CI: 0.5-0.7; drinking water: aOR = 0.5, 95% CI: 0.4-0.6), highlighting the importance of these factors for schistosomiasis prevention and control. These results identified additional risk populations (children < 5 years) and a new risk factor (animal ownership) and could be used to monitor the impact of control programs.


Asunto(s)
Agua Potable , Esquistosomiasis , Niño , Masculino , Animales , Humanos , Estudios Seroepidemiológicos , Nigeria/epidemiología , Esquistosomiasis/epidemiología , Factores de Riesgo , Schistosoma
4.
Front Immunol ; 14: 1208822, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37691957

RESUMEN

Background: Plasmodium falciparum malaria is a leading cause of child mortality in Nigeria. Neonates are born with maternal antibodies from placental transfer which may protect against malaria infection in the first months of life. The IgG dynamics of the transition from passively transferred antimalarial antibodies to actively acquired IgG from natural exposure have not been well elucidated. Methods: Blood samples collected during a 2018 Nigeria nationwide HIV/AIDS household survey were available for 9,443 children under 5 years of age, with a subset of infants under 2 months of age having maternal samples available (n=41). Samples were assayed for the P. falciparum HRP2 antigen and anti-malarial IgG antibodies. LOESS regression examined the dynamics in IgG response in the first 5 years of life. Correlation with maternal IgG levels was assessed for mother/child pairs. Results: Consistent decreases were observed in median IgG levels against all Plasmodium spp. antigen targets for the first months of life. At a population level, P. falciparum apical membrane antigen-1 (AMA1) and merozoite surface protein-1 19kD (PfMSP1) IgG decreased during the first 12 months of life before reaching a nadir, whereas IgGs to other targets only declined for the first 4 months of life. Seropositivity showed a similar decline with the lowest seropositivity against AMA1 and PfMSP1 at 10-12 months, though remaining above 50% during the first 2 years of life in higher transmission areas. No protective association was observed between IgG positivity and P. falciparum infection in infants. Maternal antibody levels showed a strong positive correlation with infant antibody levels for all P. falciparum antigens from birth to 2 months of age, but this correlation was lost by 6 months of age. Discussion: Maternally transferred anti-malarial IgG antibodies rapidly decline during the first 6 months of life, with variations among specific antigens and malaria transmission intensity. From 3-23 months of age, there was a wide range in IgG levels for the blood-stage antigens indicating high individual variation in antibody production as children are infected with malaria. Non-falciparum species-specific antigens showed similar patterns in waning immunity and correlation with paired mother's IgG levels compared to P. falciparum antigens.


Asunto(s)
Antimaláricos , Malaria Falciparum , Plasmodium , Embarazo , Recién Nacido , Humanos , Niño , Lactante , Femenino , Preescolar , Inmunoglobulina G , Formación de Anticuerpos , Placenta , Antígenos de Protozoos
5.
Nat Commun ; 14(1): 1360, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36914649

RESUMEN

Plasmodium falciparum (Pf) is the dominant malaria parasite in Nigeria though P. vivax (Pv), P. ovale (Po), and P. malariae (Pm) are also endemic. Blood samples (n = 31,234) were collected from children aged 0-14 years during a 2018 nationwide HIV survey and assayed for Plasmodium antigenemia, Plasmodium DNA, and IgG against Plasmodium MSP1-19 antigens. Of all children, 6.6% were estimated to have Pm infection and 1.4% Po infection with no Pv infections detected. The highest household wealth quintile was strongly protective against infection with Pm (aOR: 0.11, 95% CI: 0.05-0.22) or Po (aOR= 0.01, 0.00-0.10). Overall Pm seroprevalence was 34.2% (95% CI: 33.3-35.2) with lower estimates for Po (12.1%, 11.6-12.5) and Pv (6.3%, 6.0-6.7). Pm seropositivity was detected throughout the country with several local government areas showing >50% seroprevalence. Serological and DNA indicators show widespread exposure of Nigerian children to Pm with lower rates to Po and Pv.


Asunto(s)
Malaria Falciparum , Malaria Vivax , Malaria , Plasmodium , Humanos , Niño , Estudios Seroepidemiológicos , Nigeria/epidemiología , Malaria/epidemiología , Malaria/parasitología , Malaria Vivax/parasitología , Plasmodium falciparum/genética , Antígenos de Protozoos , Inmunoglobulina G , Malaria Falciparum/parasitología , Plasmodium vivax/genética
6.
Sci Rep ; 13(1): 1998, 2023 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-36737630

RESUMEN

Prevalence estimates are critical for malaria programming efforts but generating these from non-malaria surveys is not standard practice. Malaria prevalence estimates for 6-59-month-old Nigerian children were compared between two national household surveys performed simultaneously in 2018: a Demographic and Health Survey (DHS) and the Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS). DHS tested via microscopy (n = 8298) and HRP2-based rapid diagnostic test (RDT, n = 11,351), and NAIIS collected dried blood spots (DBS) which were later tested for histidine-rich protein 2 (HRP2) antigen (n = 8029). National Plasmodium falciparum prevalence was 22.6% (95% CI 21.2- 24.1%) via microscopy and 36.2% (34.6- 37.8%) via RDT according to DHS, and HRP2 antigenemia was 38.3% (36.7-39.9%) by NAIIS DBS. Between the two surveys, significant rank-order correlation occurred for state-level malaria prevalence for RDT (Rho = 0.80, p < 0.001) and microscopy (Rho = 0.75, p < 0.001) versus HRP2. RDT versus HRP2 positivity showed 24 states (64.9%) with overlapping 95% confidence intervals from the two independent surveys. P. falciparum prevalence estimates among 6-59-month-olds in Nigeria were highly concordant from two simultaneous, independently conducted household surveys, regardless of malaria test utilized. This provides evidence for the value of post-hoc laboratory HRP2 detection to leverage non-malaria surveys with similar sampling designs to obtain accurate P. falciparum estimates.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida , Malaria Falciparum , Niño , Preescolar , Humanos , Lactante , Antígenos de Protozoos , Pruebas Diagnósticas de Rutina , Malaria Falciparum/diagnóstico , Malaria Falciparum/epidemiología , Nigeria/epidemiología , Plasmodium falciparum , Prevalencia , Proteínas , Proteínas Protozoarias , Sensibilidad y Especificidad , Encuestas Epidemiológicas
7.
J Clin Virol Plus ; 3(1): 100139, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36683611

RESUMEN

Objectives: Determining an accurate estimate of SARS-CoV-2 seroprevalence has been challenging in African countries where malaria and other pathogens are endemic. We compared the performance of one single-antigen assay and three multi-antigen SARS-CoV-2 IgG assays in a Nigerian population endemic for malaria. Methods: De-identified plasma specimens from SARS-CoV-2 RT-PCR positive, dried blood spot (DBS) SARS-CoV-2 RT-PCR positive, and pre-pandemic negatives were used to evaluate the performance of the four SARS-CoV-2 assays (Tetracore, SARS2MBA, RightSign, xMAP). Results: Results showed higher sensitivity with the multi-antigen (81% (Tetracore), 96% (SARS2MBA), 85% (xMAP)) versus the single-antigen (RightSign (64%)) SARS-CoV-2 assay. The overall specificities were 98% (Tetracore), 100% (SARS2MBA and RightSign), and 99% (xMAP). When stratified based on <15 days to ≥15 days post-RT-PCR confirmation, the sensitivities increased from 75% to 88.2% for Tetracore; from 93% to 100% for the SARS2MBA; from 58% to 73% for RightSign; and from 83% to 88% for xMAP. With DBS, there was no positive increase after 15-28 days for the three assays (Tetracore, SARS2MBA, and xMAP). Conclusion: Multi-antigen assays performed well in Nigeria, even with samples with known malaria reactivity, and might provide more accurate measures of COVID-19 seroprevalence and vaccine efficacy.

8.
PLoS One ; 17(4): e0266184, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35363818

RESUMEN

OBJECTIVE: There is a need for reliable serological assays to determine accurate estimates of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seroprevalence. Most single target antigen assays have shown some limitations in Africa. To assess the performance of a multi-antigen assay, we evaluated a commercially available SARS-CoV-2 Multi-Antigen IgG assay for human coronavirus disease 2019 (COVID-19) in Nigeria. METHODS: Validation of the xMAP SARS-CoV-2 Multi-Antigen IgG assay was carried out using well-characterized SARS-CoV-2 reverse transcription polymerase chain reactive positive (97) and pre-COVID-19 pandemic (86) plasma panels. Cross-reactivity was assessed using pre-COVID-19 pandemic plasma specimens (213) from the 2018 Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS). RESULTS: The overall sensitivity of the xMAP SARS-CoV-2 Multi-Antigen IgG assay was 75.3% [95% CI: 65.8%- 82.8%] and specificity was 99.0% [95% CI: 96.8%- 99.7%]. The sensitivity estimate increased to 83.3% [95% CI: 70.4%- 91.3%] for specimens >14 days post-confirmation of diagnosis. However, using the NAIIS pre-pandemic specimens, the false positivity rate was 1.4% (3/213). CONCLUSIONS: Our results showed overall lower sensitivity and a comparable specificity with the manufacturer's validation. There appears to be less cross-reactivity with NAIIS pre-pandemic COVID-19 specimens using the xMAP SARS-CoV-2 Multi-Antigen IgG assay. In-country SARS-CoV-2 serology assay validation can help guide the best choice of assays in Africa.


Asunto(s)
COVID-19 , Pandemias , Anticuerpos Antivirales , COVID-19/diagnóstico , COVID-19/epidemiología , Humanos , Inmunoglobulina G , Nigeria/epidemiología , SARS-CoV-2 , Sensibilidad y Especificidad , Estudios Seroepidemiológicos
9.
PLOS Glob Public Health ; 2(7): e0000466, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962526

RESUMEN

BACKGROUND: The Nigeria AIDS Indicator and Impact Survey (NAIIS), a cross-sectional household survey, was conducted in 2018 with primary objectives to estimate HIV prevalence, HIV-1 incidence, and status of UNAIDS 90-90-90 cascade. We conducted retrospective analysis of the performance of HIV rapid tests and the national HIV testing algorithm used in Nigeria. METHODS: The national algorithm included Determine HIV-1/2 as test 1 (T1), Unigold HIV-1/2 as test 2 (T2), and StatPak HIV-1/2 as the tie-breaker test (T3). Individuals reactive with T1 and either T2 or T3 were considered HIV-positive. HIV-positive specimens from the algorithm were further confirmed for the survey using supplemental test Geenius HIV-1/2. If Geenius did not confirm HIV-positive status, HIV-1 Western blot was performed. We calculated the concordance between tests and positive predictive value (PPV) of the algorithm on unweighted data. RESULTS: Of 204,930 participants (ages ≥18 months) 5,103 (2.5%) were reactive on T1. Serial testing of T1 reactive specimens with T2 or if needed by tiebreaker T3 identified 2958 (1.44%) persons as HIV-positive. Supplemental testing confirmed 2,800 (95%) as HIV-positive (HIV-1 = 2,767 [98.8%]; HIV-2 = 5 [0.2%]; dual infections = 22 [0.8%]). Concordance between T1 and T2 was 56.6% while PPV of the national algorithm was 94.5%. CONCLUSIONS: Our results show high discordant rates and poor PPV of the national algorithm with a false-positive rate of about 5.5% in the NAIIS survey. Considering our findings have major implications for HIV diagnosis in routine HIV testing services, additional evaluation of testing algorithm is warranted in Nigeria.

10.
PLOS Glob Public Health ; 2(11): e0001077, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36962660

RESUMEN

Human Immunodeficiency Virus (HIV) diagnosis remains the gateway to HIV care and treatment. However, due to changes in HIV prevalence and testing coverage across different geopolitical zones, it is crucial to evaluate the national HIV testing algorithm as false positivity due to low prevalence could be detrimental to both the client and the service delivery. Therefore, we evaluated the performance of the national HIV rapid testing algorithm using specimens collected from multiple HIV testing services (HTS) sites and compared the results from different HIV prevalence levels across the six geopolitical zones of Nigeria. The evaluation employed a dual approach, retrospective, and prospective. The retrospective evaluation focused on a desktop review of program data (n = 492,880) collated from patients attending routine HTS from six geopolitical zones of Nigeria between January 2017 and December 2019. The prospective component utilized samples (n = 2,895) collected from the field at the HTS and tested using the current national serial HIV rapid testing algorithm. These samples were transported to the National Reference Laboratory (NRL), Abuja, and were re-tested using the national HIV rapid testing algorithm and HIV-1/2 supplementary assays (Geenius to confirm positives and resolve discordance and multiplex assay). The retrospective component of the study revealed that the overall proportion of HIV positives, based on the selected areas, was 5.7% (28,319/492,880) within the study period, and the discordant rate between tests 1 and 2 was 1.1%. The prospective component of the study indicated no significant differences between the test performed at the field using the national HIV rapid testing algorithm and the re-testing performed at the NRL. The comparison between the test performed at the field using the national HIV rapid testing algorithm and Geenius HIV-1/2 supplementary assay showed an agreement rate of 95.2%, while that of the NRL was 99.3%. In addition, the comparison of the field results with HIV multiplex assay indicated a sensitivity of 96.6%, the specificity of 98.2%, PPV of 97.0%, and Kappa Statistic of 0.95, and that of the NRL with HIV multiplex assay was 99.2%, 99.4%, 99.0%, and 0.99, respectively. Results show that the Nigeria national serial HIV rapid testing algorithm performed very well across the target settings. However, the algorithm's performance in the field was lower than the performance outcomes under a controlled environment in the NRL. There is a need to target testers in the field for routine continuous quality improvement implementation, including refresher trainings as necessary.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...