Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Cancer Imaging ; 20(1): 72, 2020 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-33036660

RESUMEN

BACKGROUND: The aim of this study is to investigate the potential impact of prostate magnetic resonance imaging (MRI) -related interreader variability on a population-based randomized prostate cancer screening trial (ProScreen). METHODS: From January 2014 to January 2018, 100 men aged 50-63 years with clinical suspicion of prostate cancer (PCa) in Helsinki University Hospital underwent MRI. Nine radiologists individually reviewed the pseudonymized MRI scans of all 100 men in two ProScreen trial centers. All 100 men were biopsied according to a histological composite variable comprising radical prostatectomy histology (N = 38) or biopsy result within 1 year from the imaging (N = 62). Fleiss' kappa (κ) was used to estimate the combined agreement between all individual radiologists. Sample data were subsequently extrapolated to 1000-men subgroups of the ProScreen cohort. RESULTS: Altogether 89% men of the 100-men sample were diagnosed with PCa within a median of 2.4 years of follow-up. Clinically significant PCa (csPCa) was identified in 76% men. For all PCa, mean sensitivity was 79% (SD ±10%, range 62-96%), and mean specificity 60% (SD ±22%, range 27-82%). For csPCa (Gleason Grade 2-5) MRI was equally sensitive (mean 82%, SD ±9%, range 67-97%) but less specific (mean 47%, SD ±20%, range 21-75%). Interreader agreement for any lesion was fair (κ 0.40) and for PI-RADS 4-5 lesions it was moderate (κ 0.60). Upon extrapolating these data, the average sensitivity and specificity to a screening positive subgroup of 1000 men from ProScreen with a 30% prevalence of csPCa, 639 would be biopsied. Of these, 244 men would be true positive, and 395 false positive. Moreover, 361 men would not be referred to biopsy and among these, 56 csPCas would be missed. The variation among the radiologists was broad as the least sensitive radiologist would have twice as many men biopsied and almost three times more men would undergo unnecessary biopsies. Although the most sensitive radiologist would miss only 2.6% of csPCa (false negatives), the least sensitive radiologist would miss every third. CONCLUSIONS: Interreader agreement was fair to moderate. The role of MRI in the ongoing ProScreen trial is crucial and has a substantial impact on the screening process.


Asunto(s)
Imagen por Resonancia Magnética/normas , Neoplasias de la Próstata/diagnóstico por imagen , Anciano , Ensayos Clínicos como Asunto/normas , Humanos , Biopsia Guiada por Imagen , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Variaciones Dependientes del Observador , Neoplasias de la Próstata/patología , Distribución Aleatoria
2.
PLoS Med ; 16(6): e1002813, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31158230

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) combined with targeted biopsy (TB) is increasingly used in men with clinically suspected prostate cancer (PCa), but the long acquisition times, high costs, and inter-center/reader variability of routine multiparametric prostate MRI limit its wider adoption. METHODS AND FINDINGS: The aim was to validate a previously developed unique MRI acquisition and reporting protocol, IMPROD biparametric MRI (bpMRI) (NCT01864135), in men with a clinical suspicion of PCa in a multi-institutional trial (NCT02241122). IMPROD bpMRI has average acquisition time of 15 minutes (no endorectal coil, no intravenous contrast use) and consists of T2-weighted imaging and 3 separate diffusion-weighed imaging acquisitions. Between February 1, 2015, and March 31, 2017, 364 men with a clinical suspicion of PCa were enrolled at 4 institutions in Finland. Men with an equivocal to high suspicion (IMPROD bpMRI Likert score 3-5) of PCa had 2 TBs of up to 2 lesions followed by a systematic biopsy (SB). Men with a low to very low suspicion (IMPROD bpMRI Likert score 1-2) had only SB. All data and protocols are freely available. The primary outcome of the trial was diagnostic accuracy-including overall accuracy, sensitivity, specificity, negative predictive value (NPV), and positive predictive value-of IMPROD bpMRI for clinically significant PCa (SPCa), which was defined as a Gleason score ≥ 3 + 4 (Gleason grade group 2 or higher). In total, 338 (338/364, 93%) prospectively enrolled men completed the trial. The accuracy and NPV of IMPROD bpMRI for SPCa were 70% (113/161) and 95% (71/75) (95% CI 87%-98%), respectively. Restricting the biopsy to men with equivocal to highly suspicious IMPROD bpMRI findings would have resulted in a 22% (75/338) reduction in the number of men undergoing biopsy while missing 4 (3%, 4/146) men with SPCa. The main limitation is uncertainty about the true PCa prevalence in the study cohort, since some of the men may have PCa despite having negative biopsy findings. CONCLUSIONS: IMPROD bpMRI demonstrated a high NPV for SPCa in men with a clinical suspicion of PCa in this prospective multi-institutional clinical trial. TRIAL REGISTRATION: ClinicalTrials.gov NCT02241122.


Asunto(s)
Imagen por Resonancia Magnética/normas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/epidemiología , Anciano , Finlandia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor/normas , Estudios Prospectivos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...