Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
Front Pharmacol ; 14: 1229095, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37745064

RESUMEN

Introduction: Photoactivated Chromophore for Infectious Keratitis-Corneal Cross-Linking (PACK-CXL) has garnered substantial interest among researchers and ophthalmologists due to its high promise as a potential treatment for infectious keratitis. The aim of this study is to evaluate the efficacy and safety of high fluence PACK-CXL, using 10.0 J/cm2 (30 mW/cm2, 5 min, and 33 s) at the slit lamp. Methods: This prospective interventional, nonrandomized cohort study included 20 eyes of 20 patients with bacterial, fungal, or mixed origin keratitis who underwent high fluence PACK-CXL treatment as an adjunct therapy to conventional antimicrobial therapy per American Academy of Ophthalmology treatment guidelines. The re-epithelization time was recorded, and corneal endothelial cell density was counted before and after treatment. Results: The average re-epithelization time was 8.2 ± 2.8 days (range 3-14 days). After PACK-CXL treatment, eight patients (40%) were directly discharged, while the remained patients stayed in the hospital for an average of 5.6 ± 3.5 days. No eyes required keratoplasty. Endothelial cell density counts before and after the PACK-CXL procedure were 2,562.1 ± 397.3, and 2,564.8 ± 404.5 cells/mm2, respectively (p = 0.96). Conclusion: although it was not a randomized control trial, we conclude that high fluence PACK-CXL as an adjuvant therapy is safe with no complications observed, and efficient as time to re-epithelization was less than 14 days for all patients and no patients underwent tectonic keratoplasties. Further research is needed to compare it to the current standard of care.

3.
Harefuah ; 162(2): 116-118, 2023 Feb.
Artículo en Hebreo | MEDLINE | ID: mdl-37078114

RESUMEN

Myopia, short-sightedness, is the most frequent cause of vision difficulty and its prevalence is expected to rise. Nowadays, the usage of atropine drops is effective for myopia progression control. Studies on the Asian population showed that atropine 0.01% is more efficient and safer than solutions that have a higher concentration. In this study, we report findings from a multicenter Spanish study that showed that atropine 0.01% decreases the progression of myopia in a pediatric population, with relatively few adverse effects. The results of this study may be relevant to doctors who treat children who have myopia, as well as to the children treated and their parents.


Asunto(s)
Atropina , Miopía , Niño , Humanos , Atropina/efectos adversos , Soluciones Oftálmicas , Miopía/tratamiento farmacológico , Miopía/epidemiología , Prevalencia , Progresión de la Enfermedad
4.
Ocul Immunol Inflamm ; 31(6): 1151-1162, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35914308

RESUMEN

PURPOSE: To describe herpetic ocular infections following SARS-CoV-2 vaccinations. METHODS: A retrospective study of herpetic ocular infections after BNT162b2mRNA vaccination and a literature review. RESULTS: A cohort of five patients: three varicella zoster virus (VZV) and two herpes simplex virus (HSV) cases, as well as 19 literature cases: 9 cases of VZV and 10 cases of HSV post BNT162b2mRNA, AZD1222, mRNA-1273, and CoronaVac vaccinations. All cases presented within 28 days post vaccination. Most VZV and HSV cases (15/19) reported in the literature presented post first vaccine dose, while in our cohort 2 VZV cases presented post second dose and both HSV cases and one VZV case post third dose. The most common presentations were HZO with ocular involvement and HSV keratitis. All eyes had complete resolution; however, one had retinal detachment and three corneal scars. CONCLUSION: Herpetic ocular infections may develop shortly after SARS-CoV-2 vaccinations. Overall, the outcome is good.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Herpes Zóster Oftálmico , Queratitis Herpética , Humanos , ChAdOx1 nCoV-19 , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Herpes Zóster Oftálmico/diagnóstico , Herpes Zóster Oftálmico/tratamiento farmacológico , Herpes Zóster Oftálmico/etiología , Herpesvirus Humano 3/genética , Queratitis Herpética/diagnóstico , Queratitis Herpética/etiología , Estudios Retrospectivos , SARS-CoV-2 , Simplexvirus , Vacunación/efectos adversos
5.
Int Ophthalmol ; 42(9): 2665-2671, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35381894

RESUMEN

PURPOSE: To validate the effectiveness of the multi-metric D-index by Pentacam in detecting keratoconus (KC) progression. MATERIALS AND METHODS: This was a retrospective study of KC patients at the Rabin Medical Center, Petah Tikva, Israel, during 2016-2018 with at least two corneal tomography examinations six months apart. Agreement between clinical diagnosis of progression (1.5D increase in mean keratometric value, 1D increase in Kmax, a 5% decrease in central corneal thickness (CCT), worsening of visual acuity by more than one line, or deterioration of manifest corneal astigmatism > 1.5D) and the D-index was evaluated. Receiver operating characteristic (ROC) analysis was used to find the D-index's optimal cutoff value to show progression. RESULTS: We included KC eyes in the stable group (N = 7) and the progression group (N = 54). Patient demographics and tomographic parameters at baseline were similar between the groups. The D-index change was significantly higher in the progression group than in the stable group (median + 1 and 0.0, respectively, p = 0.024). Based on the ROC analysis, the optimal D-index cutoff change within at least six months was 0.32 (59.3% sensitivity and 100% specificity (area under the curve [AUC] = 0.771, Youden = 0.592). Subjects with a D-index change above this value had a 21.1-fold increase in odds for corneal ectasia progression requiring CXL (OR: 21.1, 95%CI 1.17-398.8, p = 0.038). CONCLUSION: The multi-metric D-index can serve as a clinically feasible parameter to detect KC progression and guide patients' referral for further interventions.


Asunto(s)
Queratocono , Córnea , Topografía de la Córnea , Humanos , Estudios Retrospectivos , Agudeza Visual
6.
Int Ophthalmol ; 41(10): 3451-3458, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34109478

RESUMEN

PURPOSE: To compare keratometry data between the handheld Retinomax K-plus 3 and the table-mounted IOLMaster 700. METHODS: Healthy adult volunteers were prospectively recruited to the study. All participants underwent 3 consecutive keratometry measurements using the Retinomax K-plus 3 and a single biometry assessment using the IOLMaster 700. Differences between the Retinomax K-plus 3 and the IOLMaster 700 were assessed using Wilcoxon test for paired samples, Spearman correlation, Bland-Altman and mountain plots. RESULT: Twenty-eight healthy subjects with a median age of 37 years (interquartile range (IQR) 28-44 years) were included in the study. The median mean keratometry (mean K) reading was higher using the Retinomax K-plus 3 (44.04D; IQR 42.96-45.61D) compared to the IOLMaster 700 (43.78D; IQR 43.22-44.90D, p < 0.01), with a mean difference of 0.18D (95% confidence interval (CI) 0.11-0.23D). Mean K readings were highly correlated between the 2 devices (r = 0.995, p < 0.01). Bland-Altman plots showed 95% limits of agreement between -0.14D and 0.49D. Frequency histogram of mean K reading differences between the Retinomax K-plus 3 and the IOLMaster 700 showed that 56% of cases were between ± 0.2D, 93% of cases were between ± 0.4D and all cases were between ± 0.5D. Mean corneal astigmatism measurement was higher using the Retinomax K-plus 3 (1.01 ± 0.40D) compared to the IOLMaster 700 (0.77 ± 0.36D), with a mean difference of 0.23 ± 0.37D (p < 0.01) between the devices. CONCLUSIONS: A good agreement exists between the Retinomax K-plus 3 and the IOLMaster 700 regarding keratometry readings. This enables cataract surgeons to safely use the Retinomax K-plus 3 device when indicated.


Asunto(s)
Astigmatismo , Catarata , Adulto , Biometría , Córnea , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...