Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
PLOS Glob Public Health ; 4(6): e0003378, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38913630

RESUMEN

Routine HIV viral load testing is important for evaluating HIV treatment outcomes, but conventional viral load testing has many barriers including expensive laboratory equipment and lengthy results return times to patients. A point-of-care viral load testing technology, such as GeneXpert HIV-1 quantification assay, could reduce these barriers by decreasing cost and turnaround time, however real-world performance is limited. We conducted a secondary analysis using 900 samples collected from participants in two studies to examine the performance of GeneXpert as point-of-care viral load compared to standard-of-care testing (which was conducted with two centralized laboratories using traditional HIV-1 RNA PCR quantification assays). The two studies, Opt4Kids (n = 704 participants) and Opt4Mamas (n = 820 participants), were conducted in western Kenya from 2019-2021 to evaluate the effectiveness of a combined intervention strategy, which included point-of-care viral load testing. Paired viral load results were compared using four different thresholds for virological non-suppression, namely ≥50, ≥200, ≥400, ≥1000 copies/ml. At a threshold of ≥1000 copies/mL, paired samples collected on the same day: demonstrated sensitivities of 90.0% (95% confidence interval [CI] 68.3, 98.8) and 66.7% (9.4, 99.2), specificities of 98.4% (95.5, 99.7) and 100% (96.5, 100), and percent agreements of 97.7% (94.6, 99.2) and 99.1% (95.0, 100) in Opt4Kids and Opt4Mamas studies, respectively. When lower viral load thresholds were used and the paired samples were collected an increasing number of days apart, sensitivity, specificity, and percent agreement generally decreased. While specificity and percent agreement were uniformly high, sensitivity was lower than expected. Non-specificity of the standard of care testing may have been responsible for the sensitivity values. Nonetheless, our results demonstrate that GeneXpert may be used reliably to monitor HIV treatment in low- and middle- income countries to attain UNAID's 95-95-95 HIV goals.

2.
J Int AIDS Soc ; 26(11): e26182, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37938856

RESUMEN

INTRODUCTION: Lack of viral suppression (VS) among pregnant and breastfeeding women living with HIV poses challenges for maternal and infant health, and viral load (VL) monitoring via centralized laboratory systems faces many barriers. We aimed to determine the impact of point-of-care (POC) VL and targeted drug resistance mutation (DRM) testing in improving VS among pregnant and postpartum women on antiretroviral therapy. METHODS: We conducted a pre/post-intervention prospective cohort study among 820 pregnant women accessing HIV care at five public-sector facilities in western Kenya from 2019 to 2022. The pre-intervention or "control" group consisted of standard-of-care (SOC) centralized VL testing every 6 months and the post-intervention or "intervention" group consisted of a combined strategy of POC VL every 3 months, targeted DRM testing, and clinical management support. The primary outcome was VS (VL ≤1000 copies/ml) at 6 months postpartum; secondary outcomes included uptake and turnaround times for VL testing and sustained VS. RESULTS: At 6 months postpartum, 321/328 (98%) of participants in the intervention group and 339/347 (98%) in the control group achieved VS (aRR 1.00, 95% confidence interval [CI] 0.98, 1.02). When assessing VS using a threshold of <40 copies/ml, VS proportions were lower overall (90-91%) but remained similar between groups. Among women with viraemia (VL>1000 copies/ml) who underwent successful DRM testing in the intervention group, all (46/46, 100%) had some DRMs and 20 (43%) had major DRMs (of which 80% were nucleos(t)ide reverse transcriptase inhibitor mutations). POC VL testing uptake was high (>89%) throughout pregnancy, delivery, and postpartum periods, with a median turnaround time of 1 day (IQR 1, 4) for POC VL in the intervention group and 7 days (IQR 5, 9) for SOC VL in the control group. Sustained VS throughout follow-up was similar between groups with either POC or SOC VL testing (90-91% for <1000 copies/ml, 62-70% for <40 copies/ml). CONCLUSIONS: Our combined strategy markedly decreased turnaround time but did not increase VS rates, which were already very high, or sustained VS among pregnant and postpartum women living with HIV. Further research on how best to utilize POC VL and DRM testing is needed to optimize sustained VS among this population.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Lactante , Humanos , Embarazo , Femenino , Kenia , Infecciones por VIH/tratamiento farmacológico , Estudios Prospectivos , Sistemas de Atención de Punto , Carga Viral , Periodo Posparto , Fármacos Anti-VIH/uso terapéutico
3.
J Clin Invest ; 133(13)2023 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-37219944

RESUMEN

BackgroundSARS-CoV-2 infection in Africa has been characterized by a less severe disease profile than what has been observed elsewhere, but the profile of SARS-CoV-2-specific adaptive immunity in these mainly asymptomatic patients has not, to our knowledge, been analyzed.MethodsWe collected blood samples from residents of rural Kenya (n = 80), who had not experienced any respiratory symptoms or had contact with individuals with COVID-19 and had not received COVID-19 vaccines. We analyzed spike-specific antibodies and T cells specific for SARS-CoV-2 structural (membrane, nucleocapsid, and spike) and accessory (ORF3a, ORF7, ORF8) proteins. Pre-pandemic blood samples collected in Nairobi (n = 13) and blood samples from mild-to-moderately symptomatic COVID-19 convalescent patients (n = 36) living in the urban environment of Singapore were also studied.ResultsAmong asymptomatic Africans, we detected anti-spike antibodies in 41.0% of the samples and T cell responses against 2 or more SARS-CoV-2 proteins in 82.5% of samples examined. Such a pattern was absent in the pre-pandemic samples. Furthermore, distinct from cellular immunity in European and Asian COVID-19 convalescents, we observed strong T cell immunogenicity against viral accessory proteins (ORF3a, ORF8) but not structural proteins, as well as a higher IL-10/IFN-γ cytokine ratio profile.ConclusionsThe high incidence of T cell responses against different SARS-CoV-2 proteins in seronegative participants suggests that serosurveys underestimate SARS-CoV-2 prevalence in settings where asymptomatic infections prevail. The functional and antigen-specific profile of SARS-CoV-2-specific T cells in African individuals suggests that environmental factors can play a role in the development of protective antiviral immunity.FundingUS Centers for Disease Control and Prevention, Division of Global Health Protection; the Singapore Ministry of Health's National Medical Research Council (COVID19RF3-0060, COVID19RF-001, COVID19RF-008, MOH-StaR17Nov-0001).


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Adulto , Kenia/epidemiología , Linfocitos T , COVID-19/epidemiología , Vacunas contra la COVID-19 , Prevalencia , Anticuerpos Antivirales
4.
Diagn Microbiol Infect Dis ; 102(2): 115591, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34920265

RESUMEN

Testing for SARS-CoV-2 in resource-poor settings remains a considerable challenge. Gold standard nucleic acid tests are expensive and depend on availability of expensive equipment and highly trained laboratory staff. More affordable and easier rapid antigen tests are an attractive alternative. This study assessed field performance of such a test in western Kenya. We conducted a prospective multi-facility field evaluation study of NowCheck COVID-19 Ag-RDT compared to gold standard PCR. Two pairs of oropharyngeal and nasopharyngeal swabs were collected for comparative analysis. With 997 enrolled participants the Ag-RDT had a sensitivity 71.5% (63.2-78.6) and specificity of 97.5% (96.2-98.5) at cycle threshold value <40. Highest sensitivity of 87.7% (77.2-94.5) was observed in samples with cycle threshold values ≤30. NowCheck COVID-19 Ag-RDT performed well at multiple healthcare facilities in an African field setting. Operational specificity and sensitivity were close to WHO-recommended thresholds.


Asunto(s)
Antígenos Virales/análisis , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virología , Orofaringe/virología , SARS-CoV-2/inmunología , Adulto , Niño , Estudios Transversales , Países en Desarrollo , Pruebas Diagnósticas de Rutina , Femenino , Humanos , Kenia , Masculino , Persona de Mediana Edad , Pruebas en el Punto de Atención , Estudios Prospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...