Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Asunto principal
Intervalo de año de publicación
1.
Chem Asian J ; : e202400571, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38775047

RESUMEN

Photoacoustic (PA) imaging is a novel biological imaging technique with superior depth resolution compared to fluorescence imaging. The efficacy of PA imaging depends on contrast agents that possess considerable absorbance at longer wavelengths, coupled with high permeability in biological tissue and minimal fluorescence, achieved through mitigating aggregation-caused quenching (ACQ) that attenuates PA intensity. Despite the successful transfer of porphyrin 2 featuring amino moieties from polysaccharides to liposomes, most of 2 incorporated within λ-carrageenan (CGN-2 complex) remained in CGN under acidic lysosomal conditions (pH 5.0). Consequently, the CGN-2 complex exhibited a strong PA signal under 680 nm photoirradiation in Colon26 cells owing to the ACQ of 2. Moreover, the PA intensity of the CGN-2 complex was further enhanced under 780 nm photoirradiation owing to the increased absorbance at 780 nm facilitated by the redshift of the Q-band at pH 5.0.

2.
Chemistry ; 29(10): e202203071, 2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36415055

RESUMEN

Herein, trimethyl-ß-cyclodextrin (TMe-ß-CDx) and γ-cyclodextrin (γ-CDx) could dissolve a tetraphenylethylene derivative (TPE-OH4 ) in water through high-speed vibration milling. The fluorescence intensity of the TMe-ß-CDx-TPE-OH4 complex was much higher than that of the γ-CDx-TPE-OH4 complex, as the rotation of the central C=C double bond of TPE-OH4 after photoactivation was inhibited in a smaller TMe-ß-CDx cavity in comparison with the γ-CDx cavity. In contrast, the fluorescence intensity of the γ-CDx-TPE-OH4 complex was very weak; nevertheless, it increased after the addition of liposomes due to the transfer of TPE-OH4 from the γ-CDx cavity to the lipid membrane as a "turn-on" phenomenon. Furthermore, to apply temperature sensor, it was demonstrated that the fluorescence intensity in the liposomes depended on the phase-transition temperature. By using the fluorescence turn-on phenomenon, TPE-OH4 could detect the presence of HeLa cells and E. coli by fluorescence.


Asunto(s)
Ciclodextrinas , Humanos , Ciclodextrinas/química , Liposomas , Escherichia coli , Células HeLa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...