Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biomolecules ; 14(3)2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38540678

RESUMEN

The present study aimed to investigate the effect of a H2S donor, GYY 4137, on human pulmonary arteries and whether low-frequency ultrasound (20 kHz, 4 W/cm2) inhibits GYY 4137 contractions. Functional studies were conducted on human and rat pulmonary arteries mounted on microvascular myographs. We placed an ultrasonic gadget in the tissue organ bath to insonate the arteries with low-frequency ultrasound. To measure the effect of the low-frequency ultrasound on the entrance of extracellular Ca2+, the preparations were placed in a Ca2+-free solution, and the thromboxane agonist, U46619, and extracellular calcium were added in the presence of insonation. In isolated human pulmonary arteries, GYY 4137 induced contractions, which were most pronounced in the arteries contracted with the thromboxane analogue, U46619. The transient GYY4137 contractions were reversed by low-frequency ultrasound, a blocker of KV7 channels, XE-991 (10 µM), and glibenclamide (1 µM), a blocker of ATP-sensitive channels. Low-frequency ultrasound also inhibited the contractions induced by the smooth muscle entrance of increasing extracellular calcium concentrations. The present findings show that GYY 4137 can cause a transient contraction of pulmonary arteries in human arteries. GYY 4137 alone does not cause significant vascular contraction in rat lung arteries, but it contracts rat lung arteries precontracted with U46619. The transient contractions induced by GYY 4137 can be inhibited by low-frequency ultrasound, probably by counteracting the influx of external Ca2+. The effect of low-frequency ultrasound counteracts contraction in pulmonary arteries; therefore, a possibility could be to develop a larger device allowing treatment of patients with pulmonary hypertension.


Asunto(s)
Morfolinas , Músculo Liso Vascular , Compuestos Organotiofosforados , Arteria Pulmonar , Humanos , Ratas , Animales , Ácido 15-Hidroxi-11 alfa,9 alfa-(epoximetano)prosta-5,13-dienoico/farmacología , Calcio/farmacología , Tromboxanos/farmacología
2.
Respir Res ; 25(1): 70, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38317182

RESUMEN

BACKGROUND: Currently, there are no reliable clinical tools that allow non-invasive therapeutic support for patients with pulmonary arterial hypertension. This study aims to propose a low-frequency ultrasound device for pulmonary hypertension therapy and to demonstrate its potential. METHODS: A novel low-frequency ultrasound transducer has been developed. Due to its structural properties, it is excited by higher vibrational modes, which generate a signal capable of deeply penetrating biological tissues. A methodology for the artificial induction of pulmonary hypertension in sheep and for the assessment of lung physiological parameters such as blood oxygen concentration, pulse rate, and pulmonary blood pressure has been proposed. RESULTS: The results showed that exposure of the lungs to low-frequency ultrasound changed physiological parameters such as blood oxygen concentration, pulse rate and blood pressure. These parameters are most closely related to indicators of pulmonary hypertension (PH). The ultrasound exposure increased blood oxygen concentration over a 7-min period, while pulse rate and pulmonary blood pressure decreased over the same period. In anaesthetised sheep exposed to low-frequency ultrasound, a 10% increase in SpO2, a 10% decrease in pulse rate and an approximate 13% decrease in blood pressure were observed within 7 min. CONCLUSIONS: The research findings demonstrate the therapeutic efficiency of low-frequency ultrasound on hypertensive lungs, while also revealing insights into the physiological aspects of gas exchange within the pulmonary system.


Asunto(s)
Hipertensión Pulmonar , Humanos , Animales , Ovinos , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/terapia , Pulmón/diagnóstico por imagen , Ultrasonografía , Presión Sanguínea , Oxígeno
3.
Sensors (Basel) ; 23(7)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37050668

RESUMEN

The safety of ultrasound exposure is very important for a patient's well-being. High-frequency (1-10 MHz) ultrasound waves are highly absorbed by biological tissue and have limited therapeutic effects on internal organs. This article presents the results of the development and application of a low-frequency (20-100 kHz) ultrasonic transducer for sonication of biological tissues. Using the methodology of digital twins, consisting of virtual and physical twins, an ultrasonic transducer has been developed that emits a focused ultrasound signal that penetrates into deeper biological tissues. For this purpose, the ring-shaped end surface of this transducer is excited not only by the main longitudinal vibrational mode, which is typical of the flat end surface transducers used to date, but also by higher mode radial vibrations. The virtual twin simulation shows that the acoustic signal emitted by the ring-shaped transducer, which is excited by a higher vibrational mode, is concentrated into a narrower and more precise acoustic wave that penetrates deeper into the biological tissue and affects only the part of the body to be treated, but not the whole body.


Asunto(s)
Sonicación , Ultrasonido , Humanos , Diseño de Equipo , Ultrasonografía , Transductores
4.
Materials (Basel) ; 15(3)2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35160970

RESUMEN

During the single-point incremental forming (SPIF) process, a sheet is formed by a locally acting stress field on the surface consisting of a normal and shear component that is strongly affected by friction of the dragging forming tool. SPIF is usually performed under well-lubricated conditions in order to reduce friction. Instead of lubricating the contact surface of the sheet metal, we propose an innovative, environmentally friendly method to reduce the coefficient of friction by ultrasonic excitation of the metal sheet. By evaluating the tool-workpiece interaction process as non-linear due to large deformations in the metal sheet, the finite element method (FEM) allows for a virtual evaluation of the deformation and piercing parameters of the SPIF process in order to determine destructive loads.

5.
Sensors (Basel) ; 21(22)2021 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-34833535

RESUMEN

The aim of this work is to evaluate the possibility of inexpensively producing small-batch polymer sheet components using robotized single point incremental forming (SPIF) without backing plate support. An innovative method of thermal and ultrasound assisted deformation of a polymer sheet is proposed using a tool with a sphere mounted in a ring-shaped magnetic holder, the friction of which with the tool holder is reduced by ultrasound, and the heating is performed by a laser. The heated tool moving on the sheet surface locally increases the plasticity of the polyvinyl chloride (PVC) polymer in the contact zone with less deforming force does not reducing the stiffness of the polymer around the tool contact area and eliminating the need for a backing plate. The free 3D rotating ball also changes the slip of the tool on the surface of the polymer sheet by the rolling, thereby improving the surface quality of the product. The finite element method (FEM) allowed the virtual evaluation of the deformation parameters of the SPIF. Significant process parameters were found, and the behavior of the heated polymer sheet was determined.

6.
Sensors (Basel) ; 21(9)2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33946491

RESUMEN

There are many tool condition monitoring solutions that use a variety of sensors. This paper presents a self-powering wireless sensor node for shank-type rotating tools and a method for real-time end mill wear monitoring. The novelty of the developed and patented sensor node is that the longitudinal oscillations, which directly affect the intensity of the energy harvesting, are significantly intensified due to the helical grooves cut onto the conical surface of the tool holder horn. A wireless transmission of electrical impulses from the capacitor is proposed, where the collected electrical energy is charged and discharged when a defined potential is reached. The frequency of the discharge pulses is directly proportional to the wear level of the tool and, at the same time, to the surface roughness of the workpiece. By employing these measures, we investigate the support vector machine (SVM) approach for wear level prediction.

7.
Sensors (Basel) ; 22(1)2021 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-35009560

RESUMEN

This paper proposes a method for extracting information from the parameters of a single point incremental forming (SPIF) process. The measurement of the forming force using this technology helps to avoid failures, identify optimal processes, and to implement routine control. Since forming forces are also dependent on the friction between the tool and the sheet metal, an innovative solution has been proposed to actively control the friction forces by modulating the vibrations that replace the environmentally unfriendly lubrication of contact surfaces. This study focuses on the influence of mechanical properties, process parameters and sheet thickness on the maximum forming force. Artificial Neural Network (ANN) and different machine learning (ML) algorithms have been applied to develop an efficient force prediction model. The predicted forces agreed reasonably well with the experimental results. Assuming that the variability of each input function is characterized by a normal distribution, sampling data were generated. The applicability of the models in an industrial environment is due to their relatively high performance and the ability to balance model bias and variance. The results indicate that ANN and Gaussian process regression (GPR) have been identified as the most efficient methods for developing forming force prediction models.


Asunto(s)
Aprendizaje Automático , Fenómenos Mecánicos , Fricción , Metales , Redes Neurales de la Computación
8.
Biomed Tech (Berl) ; 63(3): 279-290, 2018 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-29624499

RESUMEN

Time-consuming design and manufacturing processes are a serious disadvantage when adapting human cardiovascular implants as they cause unacceptable delays after the decision to intervene surgically has been made. An ideal cardiovascular implant should have a broad range of characteristics such as strength, viscoelasticity and blood compatibility. The present research proposes the sequence of the geometrical adaptation procedures and presents their results. The adaptation starts from the identification of a person's current health status while performing abdominal aortic aneurysm (AAA) imaging, which is a point of departure for the mathematical model of a cardiovascular implant. The computerized tomography scan shows the patient-specific geometry parameters of AAA and helps to create a model using COMSOL Multiphysics software. The initial parameters for flow simulation are taken from the results of a patient survey. The simulation results allow choosing the available shape of an implant which ensures a non-turbulent flow. These parameters are essential for the design and manufacturing of an implant prototype which should be tested experimentally for the assurance that the mathematical model is adequate to a physical one. The article gives a focused description of competences and means that are necessary to achieve the shortest possible preparation of the adapted cardiovascular implant for the surgery.


Asunto(s)
Aneurisma de la Aorta Abdominal/enfermería , Aneurisma de la Aorta Abdominal/fisiopatología , Prótesis Vascular/efectos adversos , Stents/efectos adversos , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/cirugía , Sistema Cardiovascular , Humanos , Modelos Cardiovasculares , Tomografía Computarizada por Rayos X
9.
Sensors (Basel) ; 17(12)2017 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-29231850

RESUMEN

This paper proposes an approach for designing an efficient vibration energy harvester based on a vibro-impacting piezoelectric microcantilever with a geometric shape that has been rationally modified in accordance with results of dynamic optimization. The design goal is to increase the amplitudes of higher-order vibration modes induced during the vibro-impact response of the piezoelectric transducer, thereby providing a means to improve the energy conversion efficiency and power output. A rational configuration of the energy harvester is proposed and it is demonstrated that the new design retains essential modal characteristics of the optimal microcantilever structures, further providing the added benefit of less costly fabrication. The effects of structural dynamics associated with advantageous exploitation of higher vibration modes are analyzed experimentally by means of laser vibrometry as well as numerically via transient simulations of microcantilever response to random excitation. Electrical characterization results indicate that the proposed harvester outperforms its conventional counterpart (based on the microcantilever of the constant cross-section) in terms of generated electrical output. Reported results may serve for the development of impact-type micropower generators with harvesting performance that is enhanced by virtue of self-excitation of large intensity higher-order mode responses when the piezoelectric transducer is subjected to relatively low-frequency excitation with strongly variable vibration magnitudes.

10.
Sensors (Basel) ; 17(5)2017 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-28448472

RESUMEN

Frequency up-conversion is a promising technique for energy harvesting in low frequency environments. In this approach, abundantly available environmental motion energy is absorbed by a Low Frequency Resonator (LFR) which transfers it to a high frequency Piezoelectric Vibration Energy Harvester (PVEH) via impact or magnetic coupling. As a result, a decaying alternating output signal is produced, that can later be collected using a battery or be transferred directly to the electric load. The paper reports an impact-coupled frequency up-converting tandem setup with different LFR to PVEH natural frequency ratios and varying contact point location along the length of the harvester. RMS power output of different frequency up-converting tandems with optimal resistive values was found from the transient analysis revealing a strong relation between power output and LFR-PVEH natural frequency ratio as well as impact point location. Simulations revealed that higher power output is obtained from a higher natural frequency ratio between LFR and PVEH, an increase of power output by one order of magnitude for a doubled natural frequency ratio and up to 150% difference in power output from different impact point locations. The theoretical results were experimentally verified.

11.
Biomed Mater Eng ; 28(2): 117-130, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28372265

RESUMEN

The fundamental cause of diabetic limbs' problem is insufficient blood supply. The aim of the current work was to experimentally and numerically investigate the blood flow velocity and pressure changes in the channel during vibrational excitation. The micro-scale Particle Image Velocimetry (µPIV) technique as well as corresponding numerical channel model in COMSOL Multiphysics software were used to investigate the influence of external vibrations. Momentum upstream flow were noted on the fluid that was influenced by vibrations. Furthermore, momentum flow velocity increased by more than 3 times in both experimentally and theoretically. These results show that suggested novel low-frequency vibrational excitation method should be investigated in clinical studies in case of improvement of blood circulation in human limbs.


Asunto(s)
Velocidad del Flujo Sanguíneo , Complicaciones de la Diabetes/fisiopatología , Extremidad Inferior/irrigación sanguínea , Extremidad Superior/irrigación sanguínea , Simulación por Computador , Hemodinámica , Humanos , Modelos Cardiovasculares , Reología , Vibración
12.
Sensors (Basel) ; 16(1)2015 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-26703623

RESUMEN

The piezoelectric transduction mechanism is a common vibration-to-electric energy harvesting approach. Piezoelectric energy harvesters are typically mounted on a vibrating host structure, whereby alternating voltage output is generated by a dynamic strain field. A design target in this case is to match the natural frequency of the harvester to the ambient excitation frequency for the device to operate in resonance mode, thus significantly increasing vibration amplitudes and, as a result, energy output. Other fundamental vibration modes have strain nodes, where the dynamic strain field changes sign in the direction of the cantilever length. The paper reports on a dimensionless numerical transient analysis of a cantilever of a constant cross-section and an optimally-shaped cantilever with the objective to accurately predict the position of a strain node. Total effective strain produced by both cantilevers segmented at the strain node is calculated via transient analysis and compared to the strain output produced by the cantilevers segmented at strain nodes obtained from modal analysis, demonstrating a 7% increase in energy output. Theoretical results were experimentally verified by using open-circuit voltage values measured for the cantilevers segmented at optimal and suboptimal segmentation lines.

13.
Sensors (Basel) ; 15(6): 12594-612, 2015 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-26029948

RESUMEN

This paper focuses on several aspects extending the dynamical efficiency of a cantilever beam vibrating in the third mode. A few ways of producing this mode stimulation, namely vibro-impact or forced excitation, as well as its application for energy harvesting devices are proposed. The paper presents numerical and experimental analyses of novel structural dynamics effects along with an optimal configuration of the cantilever beam. The peculiarities of a cantilever beam vibrating in the third mode are related to the significant increase of the level of deformations capable of extracting significant additional amounts of energy compared to the conventional harvester vibrating in the first mode. Two types of a piezoelectric vibrating energy harvester (PVEH) prototype are analysed in this paper: the first one without electrode segmentation, while the second is segmented using electrode segmentation at the strain nodes of the third vibration mode to achieve effective operation at the third resonant frequency. The results of this research revealed that the voltage generated by any segment of the segmented PVEH prototype excited at the third resonant frequency demonstrated a 3.4-4.8-fold increase in comparison with the non-segmented prototype. Simultaneously, the efficiency of the energy harvester prototype also increased at lower resonant frequencies from 16% to 90%. The insights presented in the paper may serve for the development and fabrication of advanced piezoelectric energy harvesters which would be able to generate a considerably increased amount of electrical energy independently of the frequency of kinematical excitation.

14.
J Biomech ; 47(6): 1368-72, 2014 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-24607008

RESUMEN

According to World Health Organization obesity is one of the greatest public health challenges of the 21st century. It has tripled since the 1980s and the numbers of those affected continue to rise at an alarming rate, especially among children. There are number of devices that act as a prevention measure to boost person's motivation for physical activity and its levels. The placement of these devices is not restricted thus the measurement errors that appear because of the body rheology, clothes, etc. cannot be eliminated. The main objective of this work is to introduce a tool that can be applied directly to process measured accelerations so human body surface tissue induced errors can be reduced. Both the modeling and experimental techniques are proposed to identify body tissue rheological properties and prelate them to body mass index. Multi-level computational model composed from measurement device model and human body surface tissue rheological model is developed. Human body surface tissue induced inaccuracies can increase the magnitude of measured accelerations up to 34% when accelerations of the magnitude of up to 27 m/s(2) are measured. Although the timeframe of those disruptions are short - up to 0.2 s - they still result in increased overall measurement error.


Asunto(s)
Monitoreo Ambulatorio/instrumentación , Obesidad/prevención & control , Reología , Aceleración , Artefactos , Composición Corporal , Índice de Masa Corporal , Simulación por Computador , Humanos , Modelos Teóricos , Monitoreo Ambulatorio/métodos , Reproducibilidad de los Resultados
15.
Sensors (Basel) ; 14(1): 1805-21, 2014 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-24451467

RESUMEN

Optical investigation of movable microsystem components using time-averaged holography is investigated in this paper. It is shown that even a harmonic excitation of a non-linear microsystem may result in an unpredictable chaotic motion. Analytical results between parameters of the chaotic oscillations and the formation of time-averaged fringes provide a deeper insight into computational and experimental interpretation of time-averaged MEMS holograms.


Asunto(s)
Holografía/métodos , Sistemas Microelectromecánicos , Humanos , Movimiento (Física)
16.
Sensors (Basel) ; 13(9): 11184-95, 2013 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-23974151

RESUMEN

Due to their small size, low weight, low cost and low energy consumption, MEMS accelerometers have achieved great commercial success in recent decades. The aim of this research work is to identify a MEMS accelerometer structure for human body dynamics measurements. Photogrammetry was used in order to measure possible maximum accelerations of human body parts and the bandwidth of the digital acceleration signal. As the primary structure the capacitive accelerometer configuration is chosen in such a way that sensing part measures on all three axes as it is 3D accelerometer and sensitivity on each axis is equal. Hill climbing optimization was used to find the structure parameters. Proof-mass displacements were simulated for all the acceleration range that was given by the optimization problem constraints. The final model was constructed in Comsol Multiphysics. Eigenfrequencies were calculated and model's response was found, when vibration stand displacement data was fed into the model as the base excitation law. Model output comparison with experimental data was conducted for all excitation frequencies used during the experiments.


Asunto(s)
Aceleración , Acelerometría/instrumentación , Actigrafía/instrumentación , Sistemas Microelectromecánicos/instrumentación , Monitoreo Ambulatorio/instrumentación , Movimiento/fisiología , Transductores , Simulación por Computador , Diseño Asistido por Computadora , Capacidad Eléctrica , Electrónica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Modelos Biológicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Sensors (Basel) ; 13(4): 5368-80, 2013 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-23609803

RESUMEN

Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner's subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.


Asunto(s)
Sistemas Microelectromecánicos/instrumentación , Sistemas Microelectromecánicos/métodos , Pulso Arterial/instrumentación , Pulso Arterial/métodos , Arteria Radial/fisiología , Calibración , Humanos , Rayos Láser , Fenómenos Ópticos , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Propiedades de Superficie
18.
Sensors (Basel) ; 9(12): 10201-16, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22303170

RESUMEN

This paper reports on numerical modeling and simulation of a generalized contact-type MEMS device having large potential in various micro-sensor/actuator applications, which are currently limited because of detrimental effects of the contact bounce phenomenon that is still not fully explained and requires comprehensive treatment. The proposed 2-D finite element model encompasses cantilever microstructures operating in a vacuum and impacting on a viscoelastic support. The presented numerical analysis focuses on the first three flexural vibration modes and their influence on dynamic characteristics. Simulation results demonstrate the possibility to use higher modes and their particular points for enhancing MEMS performance and reliability through reduction of vibro-impact process duration.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...