RESUMEN
Antibiotic-resistant microorganisms have become a serious threat to public health, resulting in hospital infections, the majority of which are caused by commonly used urinary tract catheters. Strategies for preventing bacterial adhesion to the catheters' surfaces have been potentially shown as effective methods, such as coating thesurface with antimicrobial biomolecules. Here, novel antimicrobial peptides (AMPs) were designed as potential biomolecules to prevent antibiotic-resistant bacteria from binding to catheter surfaces. Thiolated AMPs were synthesized using solid-phase peptide synthesis (SPPS), and prep-HPLC was used to obtain AMPs with purity greater than 90%. On the other side, the silicone catheter surface was activated by UV/ozone treatment, followed by functionalization with allyl moieties for conjugation to the free thiol group of cystein in AMPs using thiol-ene click chemistry. Peptide-immobilized surfaces were found to become more resistant to bacterial adhesion while remaining biocompatible with mammalian cells. The presence and site of conjugation of peptide molecules were investigated by immobilizing them to catheter surfaces from both ends (C-Pep and Pep-C). It was clearly demonstrated that AMPs conjugated to the surface via theirN terminus have a higher antimicrobial activity. This strategy stands out for its effective conjugation of AMPs to silicone-based implant surfaces for the elimination of bacterial infections.
RESUMEN
In this work, a biosensor based on surface plasmon field-enhanced florescence spectroscopy (SPFS) method was successfully constructed to detect the truncated form of cholera toxin, that is, its beta subunit (CTX-B). CTX-B is a relatively small molecule (12 kDa) and it was chosen as model analyte for the detection of protein toxins originated from waterborne pathogens. Recognition layer was prepared on gold-coated LaSFN9 glasses modified with 11-mercaptoundecanoic acid (11-MUA). Biotin-conjugated anti-CTX-B polyclonal antibody (B-Ab) was immobilized on streptavidin (SA) layer constructed on the 11-MUA-modified surface. CTX-B amount was determined with direct assay using B-Ab in surface plasmon resonance (SPR) mode and with sandwich assay in SPFS mode using Cy5-conjugated anti-CTX-B polyclonal antibody. Minimum detected CTX-B concentrations were 10 and 0.01 µg/ml with SPR and SPFS, respectively, showing the sensitivity of the SPFS system over the conventional one. The detection was done in 2-6 h, which was faster than both culture and polymerase chain reaction (PCR)-based methods. Stability tests were performed with SA-coated sensors (excluding B-Ab). In this form, the layer was stable after 30 days of storage in phosphate-buffered saline (PBS; 0.01 M, pH = 7.4) at +4°C. B-Ab layer was formed immediately on them before each measurement.