Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Br J Ophthalmol ; 105(4): 521-525, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32554442

RESUMEN

AIM: To determine the outcomes of Aurolab aqueous drainage implant (AADI) placed in the superotemporal versus the inferonasal quadrant in adult eyes with refractory glaucoma. METHODS: This was a retrospective study of eyes that had AADI placement and completed a minimum of 2-year follow-up. The choice of the quadrant was at the surgeon's discretion and mainly depended on the amount of scarring and conjunctival mobility. The cumulative failure rate of the AADI was defined as intraocular pressure (IOP) >21 mm Hg or not reduced by 20% below baseline on two consecutive follow-up visits after 3 months, IOP ≤5 mm Hg on two consecutive follow-up visits after 3 months, reoperation for glaucoma or a complication, or loss of light perception vision. RESULTS: We included 84 eyes with AADI in the inferonasal quadrant versus 69 eyes in the superotemporal quadrant. A significant drop in IOP was seen in both groups (18.4±10.4 mm Hg in the inferonasal group vs 17.7±11.1 mm Hg in the superotemporal group; p=0.63) at 3-month follow-up and this was maintained until last follow-up. Best-corrected visual acuity, IOP, number of IOP-lowering medications and complications were similar between the two groups at all time points. The cumulative success rate at 2-year follow-up without IOP-lowering medications was 57.1% (47.1%-68.1%) in the inferonasal group and 50.7% (39.8%-63.1%) in the superotemporal group (p=0.47). CONCLUSIONS: Inferonasal AADI placement appears to be an equally safe and effective surgical option compared with superotemporal AADI placement and may be helpful in certain clinical situations.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/cirugía , Presión Intraocular/fisiología , Implantación de Prótesis/métodos , Agudeza Visual , Adulto , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
2.
Br J Ophthalmol ; 104(7): 962-966, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31585962

RESUMEN

AIM: To report the intermediate-term outcomes of Aurolab aqueous drainage implant (AADI) surgery in paediatric eyes with refractory glaucoma. METHODS: Case records of patients below 18 years, who underwent AADI surgery between 2012 and 2015 with >2 years follow-up, were analysed. The intraocular pressure (IOP), visual acuity, number of antiglaucoma medications, complications and resurgery if any were recorded at baseline, day 1and then at months 1, 3, 6, 9, 12, 18, 24 and at the last visit. Failure was defined as IOP >18 mm Hg or not reduced by at least 30% below baseline, IOP ≤5 mm Hg on two consecutive follow-up visits after 3 months, reoperation for a complication or loss of light perception vision. RESULTS: 101 eyes of 101 patients were included with a mean age of 10.4±4.7 years at the time of surgery and a mean follow-up of 40.9±15.1 months. Glaucoma following cataract surgery was the most common type of glaucoma (n=31, 30%), followed by primary congenital glaucoma (n=29, 29%). The cumulative probability of failure was 15.8% (95% CI 10.1% to 24.5%) at 1 year, 22.7% (95% CI 15.7% to 32.2%) at 2 years, 42.5% (95% CI 32.6% to 53.9%) at 3 years and 62.1% (95% CI 49.5% to 74.8%) at the 4 years time point. CONCLUSION: The AADI showed excellent success until 2 years after surgery in paediatric eyes after which failure rates increased. Further prospective studies with longer follow-up are required to evaluate the long-term success of the AADI for paediatric glaucomas.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma/congénito , Glaucoma/cirugía , Presión Intraocular/fisiología , Niño , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Implantación de Prótesis , Estudios Retrospectivos , Tonometría Ocular , Resultado del Tratamiento , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...