Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Front Endocrinol (Lausanne) ; 15: 1297164, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38505746

RESUMEN

Background: Syndrome of inappropriate antidiuretic(SIAD) occurs secondary to various diseases, which is characterised by hypotonic hyponatremia and impaired urinary diluting capacity. Research on SIAD in both domestic and international contexts has a long history. This study objectively and comprehensively analyses the research trends, hotspots and development of SIAD research of the past 20 years using the method of bibliometric analysis. Methods: The 2003-2022 data in the Web of Science Core Collection database were searched. The Bibliometrix software package, VOSviewer and CiteSpace were used to mine, extract and visualise the retrieved literature, and the generated maps were used in analysing the main topics and trends in the field of SIAD research. Results: A total of 1215 articles published in 623 journals were included in the analysis, with a total of 18,886 citations. Results showed that the research output on SIAD has continuously increased in the past 20 years, and the United States had the highest number of publications and citations. Keywords with the highest burst strength in recent years were the most mentioned keywords, in addition to the search terms 'hyponatremia', 'covid-19', and 'mortality'. Thus, the relationship among SIAD, covid-19 and mortality may become research frontiers and trends. Fifteen milestone articles were identified through co-citation analysis, which mainly focused on the pathophysiology and treatment of SIAD. Conclusion: Based on bibliometric analysis and knowledge mapping, this study summarises development trends in the field of SIAD research, providing references for current and future research into SIAD.


Asunto(s)
COVID-19 , Hiponatremia , Humanos , Bibliometría , COVID-19/epidemiología , Bases de Datos Factuales , Conocimiento
2.
Front Endocrinol (Lausanne) ; 14: 1251718, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38116308

RESUMEN

A Chinese family was identified to have two patients with rickets, an adult female and a male child (proband), both exhibiting signs related to X-linked hypophosphatemic rickets (XLH). Gene sequencing analysis revealed a deletion of adenine at position 1985 (c.1985delA) in the PHEX-encoding gene. To investigate the relationship between this mutation and the pathogenicity of XLH, as well as analyze the effects of different dosages of PHEX gene mutations on clinical phenotypes, we developed a rat model carrying the PHEX deletion mutation. The CRISPR/Cas9 gene editing technology was employed to construct the rat model with the PHEX gene mutation (c.1985delA). Through reproductive procedures, five genotypes of rats were obtained: female wild type (X/X), female heterozygous (-/X), female homozygous wild type (-/-), male wild type (X/Y), and male hemizygous (-/Y). The rats with different genotypes underwent analysis of growth, serum biochemical parameters, and bone microstructure. The results demonstrated the successful generation of a stable rat model inheriting the PHEX gene mutation. Compared to the wild-type rats, the mutant rats displayed delayed growth, shorter femurs, and significantly reduced bone mass. Among the female rats, the homozygous individuals exhibited the smallest body size, decreased bone mass, shortest femur length, and severe deformities. Moreover, the mutant rats showed significantly lower blood phosphorus concentration, elevated levels of FGF23 and alkaline phosphatase, and increased expression of phosphorus regulators. In conclusion, the XLH rat model with the PHEX gene mutation dosage demonstrated its impact on growth and development, serum biochemical parameters, and femoral morphology.


Asunto(s)
Raquitismo Hipofosfatémico Familiar , Animales , Femenino , Masculino , Ratas , Raquitismo Hipofosfatémico Familiar/genética , Raquitismo Hipofosfatémico Familiar/diagnóstico , Genotipo , Mutación , Linaje , Endopeptidasa Neutra Reguladora de Fosfato PHEX/genética , Fósforo
3.
Sensors (Basel) ; 16(9)2016 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-27589768

RESUMEN

Gaze tracking is the technology that identifies a region in space that a user is looking at. Most previous non-wearable gaze tracking systems use a near-infrared (NIR) light camera with an NIR illuminator. Based on the kind of camera lens used, the viewing angle and depth-of-field (DOF) of a gaze tracking camera can be different, which affects the performance of the gaze tracking system. Nevertheless, to our best knowledge, most previous researches implemented gaze tracking cameras without ground truth information for determining the optimal viewing angle and DOF of the camera lens. Eye-tracker manufacturers might also use ground truth information, but they do not provide this in public. Therefore, researchers and developers of gaze tracking systems cannot refer to such information for implementing gaze tracking system. We address this problem providing an empirical study in which we design an optimal gaze tracking camera based on experimental measurements of the amount and velocity of user's head movements. Based on our results and analyses, researchers and developers might be able to more easily implement an optimal gaze tracking system. Experimental results show that our gaze tracking system shows high performance in terms of accuracy, user convenience and interest.


Asunto(s)
Investigación Empírica , Fijación Ocular/fisiología , Movimientos de la Cabeza/fisiología , Fotograbar/instrumentación , Diseño de Equipo , Humanos , Imagenología Tridimensional , Ultrasonido
4.
Sensors (Basel) ; 16(1)2016 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-26784206

RESUMEN

Most gaze tracking systems are based on the pupil center corneal reflection (PCCR) method using near infrared (NIR) illuminators. One advantage of the PCCR method is the high accuracy it achieves in gaze tracking because it compensates for the pupil center position based on the relative position of corneal specular reflection (SR). However, the PCCR method only works for user head movements within a limited range, and its performance is degraded by the natural movement of the user's head. To overcome this problem, we propose a gaze tracking method using an ultrasonic sensor that is robust to the natural head movement of users. Experimental results demonstrate that with our compensation method the gaze tracking system is more robust to natural head movements compared to other systems without our method and commercial systems.

5.
Sensors (Basel) ; 16(1)2016 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-26742045

RESUMEN

Gaze tracking is a camera-vision based technology for identifying the location where a user is looking. In general, a calibration process is applied at the initial stage of most gaze tracking systems. This process is necessary to calibrate for the differences in the eyeballs and cornea size of the user, as well as the angle kappa, and to find the relationship between the user's eye and screen coordinates. It is applied on the basis of the information of the user's pupil and corneal specular reflection obtained while the user is looking at several predetermined positions on a screen. In previous studies, user calibration was performed using various types of markers and marker display methods. However, studies on estimating the accuracy of gaze detection through the results obtained during the calibration process have yet to be carried out. Therefore, we propose the method for estimating the accuracy of a final gaze tracking system with a near-infrared (NIR) camera by using a fuzzy system based on the user calibration information. Here, the accuracy of the final gaze tracking system ensures the gaze detection accuracy during the testing stage of the gaze tracking system. Experiments were performed using a total of four types of markers and three types of marker display methods. From them, it was found that the proposed method correctly estimated the accuracy of the gaze tracking regardless of the various marker and marker display types applied.


Asunto(s)
Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Lógica Difusa , Procesamiento de Imagen Asistido por Computador/métodos , Calibración , Humanos , Rayos Infrarrojos
6.
Sensors (Basel) ; 15(3): 5935-81, 2015 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-25769050

RESUMEN

Gaze tracking systems usually utilize near-infrared (NIR) lights and NIR cameras, and the performance of such systems is mainly affected by external light sources that include NIR components. This is ascribed to the production of additional (imposter) corneal specular reflection (SR) caused by the external light, which makes it difficult to discriminate between the correct SR as caused by the NIR illuminator of the gaze tracking system and the imposter SR. To overcome this problem, a new method is proposed for determining the correct SR in the presence of external light based on the relationship between the corneal SR and the pupil movable area with the relative position of the pupil and the corneal SR. The experimental results showed that the proposed method makes the gaze tracking system robust to the existence of external light.


Asunto(s)
Córnea/fisiología , Movimientos Oculares/fisiología , Fijación Ocular , Humanos , Luz , Iluminación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...