Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Med Phys ; 51(4): 2788-2805, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38189528

RESUMEN

BACKGROUND: Accurate segmentation of lung nodules is crucial for the early diagnosis and treatment of lung cancer in clinical practice. However, the similarity between lung nodules and surrounding tissues has made their segmentation a longstanding challenge. PURPOSE: Existing deep learning and active contour models each have their limitations. This paper aims to integrate the strengths of both approaches while mitigating their respective shortcomings. METHODS: In this paper, we propose a few-shot segmentation framework that combines a deep neural network with an active contour model. We introduce heat kernel convolutions and high-order total variation into the active contour model and solve the challenging nonsmooth optimization problem using the alternating direction method of multipliers. Additionally, we use the presegmentation results obtained from training a deep neural network on a small sample set as the initial contours for our optimized active contour model, addressing the difficulty of manually setting the initial contours. RESULTS: We compared our proposed method with state-of-the-art methods for segmentation effectiveness using clinical computed tomography (CT) images acquired from two different hospitals and the publicly available LIDC dataset. The results demonstrate that our proposed method achieved outstanding segmentation performance according to both visual and quantitative indicators. CONCLUSION: Our approach utilizes the output of few-shot network training as prior information, avoiding the need to select the initial contour in the active contour model. Additionally, it provides mathematical interpretability to the deep learning, reducing its dependency on the quantity of training samples.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Redes Neurales de la Computación , Pulmón , Procesamiento de Imagen Asistido por Computador/métodos
2.
BMC Med Imaging ; 23(1): 163, 2023 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-37858039

RESUMEN

INTRODUCTION: Parameters, such as left ventricular ejection fraction, peak strain dispersion, global longitudinal strain, etc. are influential and clinically interpretable for detection of cardiac disease, while manual detection requires laborious steps and expertise. In this study, we evaluated a video-based deep learning method that merely depends on echocardiographic videos from four apical chamber views of hypertensive cardiomyopathy detection. METHODS: One hundred eighty-five hypertensive cardiomyopathy (HTCM) patients and 112 healthy normal controls (N) were enrolled in this diagnostic study. We collected 297 de-identified subjects' echo videos for training and testing of an end-to-end video-based pipeline of snippet proposal, snippet feature extraction by a three-dimensional (3-D) convolutional neural network (CNN), a weakly-supervised temporally correlated feature ensemble, and a final classification module. The snippet proposal step requires a preliminarily trained end-systole and end-diastole timing detection model to produce snippets that begin at end-diastole, and involve contraction and dilatation for a complete cardiac cycle. A domain adversarial neural network was introduced to systematically address the appearance variability of echo videos in terms of noise, blur, transducer depth, contrast, etc. to improve the generalization of deep learning algorithms. In contrast to previous image-based cardiac disease detection architectures, video-based approaches integrate spatial and temporal information better with a more powerful 3D convolutional operator. RESULTS: Our proposed model achieved accuracy (ACC) of 92%, area under receiver operating characteristic (ROC) curve (AUC) of 0.90, sensitivity(SEN) of 97%, and specificity (SPE) of 84% with respect to subjects for hypertensive cardiomyopathy detection in the test data set, and outperformed the corresponding 3D CNN (vanilla I3D: ACC (0.90), AUC (0.89), SEN (0.94), and SPE (0.84)). On the whole, the video-based methods remarkably appeared superior to the image-based methods, while few evaluation metrics of image-based methods exhibited to be more compelling (sensitivity of 93% and negative predictive value of 100% for the image-based methods (ES/ED and random)). CONCLUSION: The results supported the possibility of using end-to-end video-based deep learning method for the automated diagnosis of hypertensive cardiomyopathy in the field of echocardiography to augment and assist clinicians. TRIAL REGISTRATION: Current Controlled Trials ChiCTR1900025325, Aug, 24, 2019. Retrospectively registered.


Asunto(s)
Cardiomiopatías , Función Ventricular Izquierda , Humanos , Volumen Sistólico , Corazón , Redes Neurales de la Computación , Cardiomiopatías/diagnóstico por imagen
3.
Quant Imaging Med Surg ; 12(1): 28-42, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34993058

RESUMEN

BACKGROUND: The dose of radiation a patient receives when undergoing dual-energy computed tomography (CT) is of significant concern to the medical community, and balancing the tradeoffs between the level of radiation used and the quality of CT images is challenging. This paper proposes a method of synthesizing high-energy CT (HECT) images from low-energy CT (LECT) images using a neural network that achieves an alternative to HECT scanning by employing an LECT scan, which greatly reduces the radiation dose a patient receives. METHODS: In the training phase, the proposed structure cyclically generates HECT and LECT images to improve the accuracy of extracting edge and texture features. Specifically, we combine multiple connection methods with channel attention (CA) and pixel attention (PA) mechanisms to improve the network's mapping ability of image features. In the prediction phase, we use a model consisting of only the network component that synthesizes HECT images from LECT images. RESULTS: Our proposed method was conducted on clinical hip CT image data sets from Guizhou Provincial People's Hospital. In a comparison with other available methods [a generative adversarial network (GAN), a residual encoder-to-decoder network with a visual geometry group (VGG) pretrained model (RED-VGG), a Wasserstein GAN (WGAN), and CycleGAN] in terms of metrics of peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), normalized mean square error (NMSE), and a visual effect evaluation, the proposed method was found to perform better on each of these evaluation criteria. Compared with the results produced by CycleGAN, the proposed method improved the PSNR by 2.44%, the SSIM by 1.71%, and the NMSE by 15.2%. Furthermore, the differences in the statistical indicators are statistically significant, proving the strength of the proposed method. CONCLUSIONS: The proposed method synthesizes high-energy CT images from low-energy CT images, which significantly reduces both the cost of treatment and the radiation dose received by patients. Based on both image quality score metrics and visual effects comparisons, the results of the proposed method are superior to those obtained by other methods.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA