According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.


Asunto(s)
Familia , Cuerpo Médico , Exposición Profesional/análisis , Ácido Pentético/análogos & derivados , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Radiofármacos/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Grecia , Internacionalidad , Ácido Pentético/análisis , Ácido Pentético/uso terapéutico , Dosis de Radiación , Radiofármacos/uso terapéutico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad