Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 750
Filtrar
1.
BMJ Open ; 14(6): e085125, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38830746

RESUMEN

INTRODUCTION: Pain and disability after meniscectomy can be a substantial lifelong problem. There are few treatment options, especially for young people. Non-surgical management (rehabilitation) is an option but increasingly surgeons are performing meniscal allograft transplants (MATs) for these individuals. However, this is still an uncommon procedure, and availability and usage of MAT vary widely both in the UK and internationally. It is not known which treatment option is the most effective and cost-effective. METHODS AND ANALYSIS: The Meniscal Transplant surgery or Optimised Rehabilitation trial is an international, multicentre, randomised controlled trial. The aim is to compare the clinical and cost effectiveness of MAT versus an optimised package of individualised, progressive, rehabilitation that we have called personalised knee therapy (PKT).Participants will be recruited from sites across the UK, Australia, Canada and Belgium. The planned 144 participants provide at least 90% power to detect a 10-point difference in the Knee injury and Osteoarthritis Outcome Score (KOOS4) at 24-months post randomisation (primary outcome). A prospectively planned economic evaluation will be conducted from a healthcare system and personal social services perspective. Secondary outcome data including health utility, occupational status, sports participation, mental well-being, further treatment, and adverse events will be collected at 3, 6, 12, 18, and 24 months. Analysis will be on an intention-to-treat basis and reported in-line with the Consolidated Standards of Reporting Trials statement. ETHICS AND DISSEMINATION: The trial was approved by the London-Bloomsbury Research Ethics Committee on 19 August 2022 (22/LO/0327) and Northern Sydney Local Health District Human Research Ethics Committee, NSW, Australia on the 13 March 2023 (2022/ETH01890).Trial results will be disseminated via peer-reviewed publications, presentations at international conferences, in lay summaries and using social media as appropriate.This protocol adheres to the recommended Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) checklist. TRIAL REGISTRATION NUMBER: ISRCTN87336549.


Asunto(s)
Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Análisis Costo-Beneficio , Estudios Multicéntricos como Asunto , Meniscectomía , Meniscos Tibiales/cirugía , Meniscos Tibiales/trasplante , Lesiones de Menisco Tibial/cirugía , Lesiones de Menisco Tibial/terapia , Lesiones de Menisco Tibial/rehabilitación
2.
medRxiv ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38883764

RESUMEN

Background: Past studies associating personality with psychosis have been limited by small nonclinical samples and a focus on general symptom burden. This study uses a large clinical sample to examine personality's relationship with psychosis-specific features and compare personality dimensions across clinically and neurobiologically defined categories of psychoses. Methods: A total of 1352 participants with schizophrenia, schizoaffective disorder, and bipolar with psychosis, as well as 623 healthy controls (HC), drawn from the Bipolar-Schizophrenia Network for Intermediate Phenotypes (BSNIP-2) study, were included. Three biomarker-derived biotypes were used to separately categorize the probands. Mean personality factors (openness, conscientiousness, extraversion, agreeableness, and neuroticism) were compared between HC and proband subgroups using independent sample t-tests. A robust linear regression was utilized to determine personality differences across biotypes and diagnostic subgroups. Associations between personality factors and cognition were determined through Pearson's correlation. A canonical correlation was run between the personality factors and general functioning, positive symptoms, and negative symptoms to delineate the relationship between personality and clinical outcomes of psychosis. Results: There were significant personality differences between the proband and HC groups across all five personality factors. Overall, the probands had higher neuroticism and lower extraversion, agreeableness, conscientiousness, and openness. Openness showed the greatest difference across the diagnostic subgroups and biotypes, and greatest correlation with cognition. Openness, agreeableness, and extraversion had the strongest associations with symptom severity. Conclusions: Individuals with psychosis have different personality profiles compared to HC. In particular, openness may be relevant in distinguishing psychosis-specific phenotypes and experiences, and associated with biological underpinnings of psychosis, including cognition. Further studies should identify potential causal factors and mediators of this relationship.

3.
J R Soc Interface ; 21(215): 20230729, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38835246

RESUMEN

In recent years, blending mechanistic knowledge with machine learning has had a major impact in digital healthcare. In this work, we introduce a computational pipeline to build certified digital replicas of cardiac electrophysiology in paediatric patients with congenital heart disease. We construct the patient-specific geometry by means of semi-automatic segmentation and meshing tools. We generate a dataset of electrophysiology simulations covering cell-to-organ level model parameters and using rigorous mathematical models based on differential equations. We previously proposed Branched Latent Neural Maps (BLNMs) as an accurate and efficient means to recapitulate complex physical processes in a neural network. Here, we employ BLNMs to encode the parametrized temporal dynamics of in silico 12-lead electrocardiograms (ECGs). BLNMs act as a geometry-specific surrogate model of cardiac function for fast and robust parameter estimation to match clinical ECGs in paediatric patients. Identifiability and trustworthiness of calibrated model parameters are assessed by sensitivity analysis and uncertainty quantification.


Asunto(s)
Electrocardiografía , Cardiopatías Congénitas , Modelos Cardiovasculares , Humanos , Cardiopatías Congénitas/fisiopatología , Electrocardiografía/métodos , Niño
4.
Artículo en Inglés | MEDLINE | ID: mdl-38860740

RESUMEN

PURPOSE: The study hypothesized that the addition of lateral extra-articular tenodesis (LEAT) in anterior cruciate ligament reconstruction (ACLR) had a significant effect on ACL graft healing. METHODS: A total of 80 patients were divided into two cohorts matched for gender, age, body mass index, time from surgery to post-operative MRI and graft diameter. Forty patients underwent ACL reconstruction alone, while 40 underwent ACLR in addition to LEAT. Patients underwent a magnetic resonance imaging scan at 12 months post-surgery; tunnel apertures were measured using multiplanar reformation, graft healing was assessed using signal-to-noise quotient (SNQ) in three regions of interest and finally graft maturity and integration were classified using the Howell and Ge scale, respectively. In addition, clinical evaluation and patient-reported outcome measures were collected. RESULTS: The mean femoral tunnel widening at 12 months post-surgery was 39.8 ± 14.0% in the ACLR + LEAT group and 55.2 ± 12.7% in the ACLR alone group (p < 0.05). The mean tibial tunnel widening was 29.3 ± 12.7% in the ACLR + LEAT group and 44.4 ± 12.1% in the ACLR group (p < 0.05). The mean adjusted graft SNQ was 9.0 ± 14.9 in the ACLR + LEAT group and 9.5 ± 11.4 in the ACLR group (n.s.). CONCLUSION: At 1 year post-operatively, we noted significantly less femoral and tibial tunnel widening in the ACLR + LEAT group. LEAT did not result in a statistically significant effect on graft healing. LEVEL OF EVIDENCE: Level III.

5.
J Phys Chem A ; 128(20): 4030-4037, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38722760

RESUMEN

The multiphoton ionization/dissociation dynamics of molecular sulfur (S2) in the ultraviolet range of 205-300 nm is studied using velocity map ion imaging (VMI). In this one-color experiment, molecular sulfur (S2) is generated in a pulsed discharge and then photodissociated by UV radiation. At the three-photon level, superexcited states are accessed via two different resonant states: the B3Σu- (v' = 8-11) valence states at the one-photon level and a Rydberg state at the two-photon level. Among the decay processes of these superexcited states, dissociation to electronically excited S atoms is dominant as compared to autoionization to ionic states S2+ (X2Πg) at wavelengths λ < 288 nm. The anisotropy parameter extracted from these images reflects the parallel character of these electronic transitions. In contrast, autoionization is found to be particularly efficient at S(1D) and S(1S) detection wavelengths around 288 nm. Information obtained from the kinetic energy distributions of S atoms has revealed the existence of vibrationally excited S2+ (X2Πg (v+ > 11)) that dissociates to ionic products following one-photon absorption. This work also reveals many interesting features of S2 photodynamics compared to those of electronically analogous O2.

6.
J Pain Res ; 17: 1815-1827, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38799276

RESUMEN

Background: Pain management physicians are increasingly focused on limiting prescription opioid abuse, yet existing tools for monitoring adherence have limited accuracy. Medication event monitoring system (MEMS) is an emerging technology for tracking medication usage in real-time but has not been tested in chronic pain patients on long-term opioid regimens. Objective: We conducted a pilot clinical trial to investigate the utility of MEMS for monitoring opioid adherence and compared to traditional methods including self-report diaries, urine drug screen (UDS), and physicians' opinions. Methods: Opioid-maintained chronic pain patients were recruited from a pain management clinic. Participants (n=28) were randomly assigned to either receive MEMS bottles containing their opioid medication for a 90-day period or to continue using standard medication bottles. MEMS bottles were configured to record and timestamp all bottle openings and the number of pills that were removed from the bottle (via measurement of weight change). Results: Participants who received MEMS demonstrated highly heterogenous dosing patterns, with a substantial number of patients rapidly removing excessive amounts of medication and/or "stockpiling" medication. By comparison, physicians rated all participants as either "totally compliant" or "mostly compliant". UDS results did not reveal any illicit drug use, but 25% of participants (n=7) tested negative for their prescribed opioid metabolite. MEMS data did not correlate with physician-rated adherence (P=0.24) and UDS results (P=0.77). MEMS data consistently revealed greater non-adherence than self-report data (P<0.001). Conclusion: These results highlight the limits in our understanding of naturalistic patterns of daily opioid use in chronic pain patients as well as support the use of MEMS for detecting potential misuse as compared to routine adherence monitoring methods. Future research directions include the need to determine how MEMS could be used to improve patient outcomes, minimize harm, and aid in clinical decision-making. Trial Registration: This study was preregistered on ClinicalTrials.gov (NCT03752411).

7.
Schizophr Res ; 269: 9-17, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38703519

RESUMEN

BACKGROUND: 22q11.2 deletion syndrome (22q11DS) is one of the most robust genetic predictors of psychosis and other psychiatric illnesses. In this study, we examined 22q11DS subjects' acoustic startle responses (ASRs), which putatively index psychosis risk. Latency of the ASR is a presumptive marker of neural processing speed and is prolonged (slower) in schizophrenia. ASR measures correlate with increased psychosis risk, depend on glutamate and dopamine receptor signaling, and could serve as translational biomarkers in interventions for groups at high psychosis risk. METHODS: Startle magnitude, latency, and prepulse inhibition were assessed with a standard acoustic startle paradigm in 31 individuals with 22q11.2DS and 32 healthy comparison (HC) subjects. Surface electrodes placed on participants' orbicularis oculi recorded the electromyographic signal in ASR eyeblinks. Individuals without measurable startle blinks in the initial habituation block were classified as non-startlers. RESULTS: Across the startle session, the ASR magnitude was significantly lower in 22q11DS subjects than HCs because a significantly higher proportion of 22q11DS subjects were non-startlers. Latency of the ASR to pulse-alone stimuli was significantly slower in 22q11DS than HC subjects. Due to the overall lower 22q11DS startle response frequency and magnitudes prepulse inhibition could not be analyzed. CONCLUSIONS: Reduced magnitude and slow latency of 22q11DS subjects' responses suggest reduced central nervous system and neuronal responsiveness. These findings are consistent with significant cognitive impairments observed in 22q11DS subjects. Further research is needed to untangle the connections among basic neurotransmission dysfunction, psychophysiological responsiveness, and cognitive impairment.


Asunto(s)
Parpadeo , Síndrome de DiGeorge , Inhibición Prepulso , Reflejo de Sobresalto , Humanos , Masculino , Femenino , Reflejo de Sobresalto/fisiología , Adulto , Adolescente , Adulto Joven , Síndrome de DiGeorge/fisiopatología , Inhibición Prepulso/fisiología , Parpadeo/fisiología , Tiempo de Reacción/fisiología , Electromiografía , Estimulación Acústica
8.
Environ Res ; : 119220, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38797466

RESUMEN

Brick kiln emissions adversely affect air pollution and the health of workers and individuals living near the kilns; however, evidence of their impacts remains limited. We conducted a systematic review of brick kiln pollution (emissions, source contributions and personal exposures) and its effects on health. We extracted articles from electronic databases and through manual citation searching. We estimated pooled, sample-size-weighted means and standard deviations for personal exposures by job type; computed mean emission factors and pollutant concentrations by brick kiln design; and meta-analyzed differences in means or proportions for health outcomes between brick kiln workers and controls or for participants living near or far away from kilns. We identified 104 studies; 74 were conducted in South Asia. The most evaluated pollutants were particulate matter (PM; n=48), sulfur dioxide (SO2; n=24) and carbon monoxide (CO; n=22), and the most evaluated health outcomes were respiratory health (n=34) and musculoskeletal disorders (n=9). PM and CO emissions were higher among traditional than improved brick kilns. Mean respirable silica exposures were only measured in 4 (4%) studies and were as high as 620 µg/m3, exceeding the NIOSH recommended exposure limit by a factor of over 12. Brick kiln workers had consistently worse lung function, more respiratory symptoms, more musculoskeletal complaints, and more inflammation when compared to unexposed participants across studies; however, most studies had a small sample size and did not fully describe methods used for sampling or data collection. On average, brick kiln workers had worse health outcomes when compared to unexposed controls but study quality supporting the evidence was low. Few studies reported silica concentrations or personal exposures, but the few that did suggest that exposures are high. Further research is needed to better understand the relationship between brick kiln pollution and health among workers, and to evaluate exposure mitigation strategies.

9.
Surg Endosc ; 38(5): 2746-2755, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38561584

RESUMEN

BACKGROUND: Emergency department (ED) utilization following surgery is poorly understood and places immense strain on the healthcare system, being responsible for up to $38 billion in wasteful spending annually. The aim of this study was to quantify ED utilization following bariatric procedures to identify causes and areas of improvement. MATERIALS AND METHODS: A retrospective review of a prospectively maintained database was conducted for all patients who underwent metabolic bariatric surgery (MBS) between November 2006 and June 2019. The study includes 4703 patients across 8 hospitals in a single health system. Patients who returned to the ED within 30 and 90 days were analyzed for relation to surgery and preventability. RESULTS: Of the 4703 patients that underwent MBS, 907 (19.3%) visited the ED at least once within 90 days and 350 (7.4%) required hospital readmission. The most common bariatric procedure performed was the Roux-en-Y Gastric Bypass (RYGB) (3716/4703) with an average BMI of 43.8. The median length between discharge and ED visit was 19 days. Under 50% of patients called prior to ED presentation and 61% of these ED visits resulted in discharge. CONCLUSION: While hospital readmissions following MBS have been scrutinized in literature, investigation of ED utilization remains scarce. Our study is one of few to investigate postoperative ED utilization up to 90 days following bariatric intervention. A clear opportunity exists to improve discharge education and early post-discharge communication. This would additionally alleviate burden to allow focus on the acutely ill.


Asunto(s)
Cirugía Bariátrica , Servicio de Urgencia en Hospital , Readmisión del Paciente , Humanos , Servicio de Urgencia en Hospital/estadística & datos numéricos , Cirugía Bariátrica/estadística & datos numéricos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Readmisión del Paciente/estadística & datos numéricos , Obesidad Mórbida/cirugía , Complicaciones Posoperatorias/epidemiología
10.
J Learn Disabil ; : 222194241236164, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563210

RESUMEN

School context can shape relative intervention response in myriad ways due to factors, such as instructional quality, resource allocation, peer effects, and correlations between the school context and characteristics of enrolled students (e.g., higher-poverty students attending higher-poverty schools). In the current study, we used data from 16,000 Grade 3 students in a community-based supplemental reading intervention program to investigate the degree to which school context factors (percentage eligible for free/reduced-price lunch [FRPL], school-level achievement) relate to the differences in triannual reading fluency growth rates between students actively receiving supplemental intervention (active recipients) and those that formerly received intervention (and therefore only received general class instruction at this time; former recipients). Using Bayesian multilevel modeling, our findings indicate that school-level FRPL eligibility played a more prominent factor in growth rate differences between these two groups than school-level reading achievement. However, school-level reading achievement was much more strongly related to reading fluency differences between active and former intervention recipients at the beginning of the school year (when controlling for FRPL). Implications for investigating school-level heterogeneity in intervention response and sustainability are discussed.

12.
Psychol Med ; 54(8): 1835-1843, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38357733

RESUMEN

BACKGROUND: Enlarged pituitary gland volume could be a marker of psychotic disorders. However, previous studies report conflicting results. To better understand the role of the pituitary gland in psychosis, we examined a large transdiagnostic sample of individuals with psychotic disorders. METHODS: The study included 751 participants (174 with schizophrenia, 114 with schizoaffective disorder, 167 with psychotic bipolar disorder, and 296 healthy controls) across six sites in the Bipolar-Schizophrenia Network on Intermediate Phenotypes consortium. Structural magnetic resonance images were obtained, and pituitary gland volumes were measured using the MAGeT brain algorithm. Linear mixed models examined between-group differences with controls and among patient subgroups based on diagnosis, as well as how pituitary volumes were associated with symptom severity, cognitive function, antipsychotic dose, and illness duration. RESULTS: Mean pituitary gland volume did not significantly differ between patients and controls. No significant effect of diagnosis was observed. Larger pituitary gland volume was associated with greater symptom severity (F = 13.61, p = 0.0002), lower cognitive function (F = 4.76, p = 0.03), and higher antipsychotic dose (F = 5.20, p = 0.02). Illness duration was not significantly associated with pituitary gland volume. When all variables were considered, only symptom severity significantly predicted pituitary gland volume (F = 7.54, p = 0.006). CONCLUSIONS: Although pituitary volumes were not increased in psychotic disorders, larger size may be a marker associated with more severe symptoms in the progression of psychosis. This finding helps clarify previous inconsistent reports and highlights the need for further research into pituitary gland-related factors in individuals with psychosis.


Asunto(s)
Trastorno Bipolar , Imagen por Resonancia Magnética , Hipófisis , Trastornos Psicóticos , Esquizofrenia , Humanos , Trastornos Psicóticos/diagnóstico por imagen , Trastornos Psicóticos/patología , Masculino , Femenino , Adulto , Hipófisis/patología , Hipófisis/diagnóstico por imagen , Trastorno Bipolar/diagnóstico por imagen , Trastorno Bipolar/patología , Esquizofrenia/diagnóstico por imagen , Esquizofrenia/patología , Esquizofrenia/fisiopatología , Persona de Mediana Edad , Antipsicóticos/uso terapéutico , Antipsicóticos/farmacología , Tamaño de los Órganos , Estudios de Casos y Controles , Biomarcadores
13.
J Chem Phys ; 160(8)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38385514

RESUMEN

The identification and analysis of quantum state-specific effects can significantly deepen our understanding of detailed photodissociation dynamics. Here, we report an experimental investigation on the vibrational state-mediated photodissociation of the OCS+ cation via the A2Π1/2 (ν1 0 ν3) states by using the velocity map ion imaging technique over the photolysis wavelength range of 263-294 nm. It was found that the electronically excited S+ product channel S+(2Du) + CO (X1Σ+) was significantly enhanced when the ν1 and ν3 vibrational modes were excited. Clear deviations in the branching ratios of the electronically excited S+ channel were observed when the vibrational modes ν1 and ν3 were selectively excited. The results reveal that vibrationally excited states play a vital role in influencing the nonadiabatic couplings in the photodissociation process.

14.
Res Sq ; 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38260530

RESUMEN

Idiopathic psychosis shows considerable biological heterogeneity across cases. B-SNIP used psychosis-relevant biomarkers to identity psychosis Biotypes, which will aid etiological and targeted treatment investigations. Psychosis probands from the B-SNIP consortium (n = 1907), their first-degree biological relatives (n = 705), and healthy participants (n = 895) completed a biomarker battery composed of cognition, saccades, and auditory EEG measurements. ERP quantifications were substantially modified from previous iterations of this approach. Multivariate integration reduced multiple biomarker outcomes to 11 "bio-factors". Twenty-four different approaches indicated bio-factor data among probands were best distributed as three subgroups. Numerical taxonomy with k-means constructed psychosis Biotypes, and rand indices evaluated consistency of Biotype assignments. Psychosis subgroups, their non-psychotic first-degree relatives, and healthy individuals were compared across bio-factors. The three psychosis Biotypes differed significantly on all 11 bio-factors, especially prominent for general cognition, antisaccades, ERP magnitude, and intrinsic neural activity. Rand indices showed excellent consistency of clustering membership when samples included at least 1100 subjects. Canonical discriminant analysis described composite bio-factors that simplified group comparisons and captured neural dysregulation, neural vigor, and stimulus salience variates. Neural dysregulation captured Biotype-2, low neural vigor captured Biotype-1, and deviations of stimulus salience captured Biotype-3. First-degree relatives showed similar patterns as their Biotyped proband relatives on general cognition, antisaccades, ERP magnitudes, and intrinsic brain activity. Results extend previous efforts by the B-SNIP consortium to characterize biologically distinct psychosis Biotypes. They also show that at least 1100 observations are necessary to achieve consistent outcomes. First-degree relative data implicate specific bio-factor deviations to the subtype of their proband and may inform studies of genetic risk.

15.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 432-444, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38294963

RESUMEN

PURPOSE: This study sought to examine if achieved postoperative alignment when compared to the native anatomy would lead to a difference in Patient Reported Outcome Measures (PROMs), and whether the achieved alignment could be broadly categorised by an accepted alignment strategy. METHODS: A retrospective cohort study of prospectively collected data on patients undergoing single primary or bilateral simultaneous total knee arthroplasty (TKA) was carried out. CT scans were used to determine the mean change ("delta values") between the pre and postoperative; hip-knee-ankle angle, lateral distal femoral angle, medial proximal tibial angle and femoral implant rotation. Femoral implant flexion and tibial implant slope were measured postoperatively. The primary outcome was the relationship of the variables to the change in KOOS pain subscale after one year. The secondary outcome was the number of knees which could be categorised postoperatively to an alignment strategy, and the mean PROMs in each cohort. RESULTS: A total of 296 knees in 261 patients were available for analysis. With regards to the primary outcome, the delta values for each variable did not demonstrate any association with the change in knee injury and osteoarthritis outcome score (KOOS) pain score. Approximately 46% of knees could not be categorised to an alignment strategy based on postoperatively measured alignment, with no significant difference between each cohort with regards to the change in KOOS Pain score. CONCLUSION: Achieved alignment does not consistently match accepted alignment strategies, and appears to confer no benefit to clinical outcomes when the native anatomy is most closely approximated, nor results in poorer outcomes in outliers. This study highlights the importance of routine three dimensional pre and postoperative imaging in clinical practice and for the valid analysis of outcomes in studies on alignment. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Dolor/cirugía
16.
Nat Nanotechnol ; 19(5): 668-676, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38242986

RESUMEN

Positron emission particle tracking (PEPT) enables 3D localization and tracking of single positron-emitting radiolabelled particles with high spatiotemporal resolution. The translation of PEPT to the biomedical imaging field has been limited due to the lack of methods to radiolabel biocompatible particles with sufficient specific activity and protocols to isolate a single particle in the sub-micrometre size range, below the threshold for capillary embolization. Here we report two key developments: the synthesis and 68Ga-radiolabelling of homogeneous silica particles of 950 nm diameter with unprecedented specific activities (2.1 ± 1.4 kBq per particle), and the isolation and manipulation of a single particle. We have combined these developments to perform in vivo PEPT and dynamic positron emission tomography (PET) imaging of a single radiolabelled sub-micrometre size particle using a pre-clinical positron emission tomography/computed tomography scanner. This work opens possibilities for quantitative assessment of haemodynamics in vivo in real time, at the whole-body level using minimal amounts of injected radioactive dose and material.


Asunto(s)
Tomografía de Emisión de Positrones , Animales , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Galio/química , Ratones , Dióxido de Silicio/química , Tamaño de la Partícula , Nanopartículas/química , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
17.
J ISAKOS ; 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38185248

RESUMEN

OBJECTIVES: We aimed to determine whether the site of anatomical degenerative change could be identified as an independent risk factor influencing clinical outcome of total knee arthroplasty (TKA) 12 months postoperatively. METHODS: We compared preoperative, postoperative and the change observed in Oxford Knee Score (OKS) amongst TKA patients categorised as primarily medial, lateral or patellofemoral osteoarthritis (PFJOA). Multivariable regression analysis was conducted on 434 consecutive knees in 333 patients, adjusting for sex, age and body mass index (BMI). RESULTS: Adjusted estimates showed that preoperatively, patients with medial and lateral osteoarthritis (OA) had a lower mean OKS of 2.1 (p â€‹= â€‹0.049) and 2.3 (p â€‹= â€‹0.056) points respectively, while those with PFJOA had mean scores 2.7 points higher (p â€‹= â€‹0.062). There was no statistically significant difference between compartments in absolute postoperative OKS. The greatest improvement of 30.1 points (95% confidence interval (CI) 16.9-36.0, p â€‹= â€‹0.012) in OKS was observed for those with lateral OA, followed by 28.9 points (95% CI 16.7-35.3, p â€‹= â€‹0.049) for those with medial OA. The improvement observed postoperatively in patients with PFJOA was less than that observed for the average of the cohort at 24.5 (95% CI 11.5-29.7, p â€‹= â€‹0.088). CONCLUSIONS: The site of compartmental involvement in knee OA is an independent factor influencing clinical outcome of TKA. With arthroplasty registry adoption of patient-reported outcome measures (PROMs), this study supports precise anatomical categorisation of knee OA in outcome studies. LEVEL OF EVIDENCE: Level III, Retrospective consecutive clinical study.

18.
Chemistry ; 30(9): e202303227, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38078726

RESUMEN

Understanding the factors that shape the circularly polarised luminescence (CPL) emission profiles of europium(III)-based CPL emitters to have specific sign properties, e. g. monosignate individual CPL transitions, is key to design novel complexes for applications ranging from advanced security inks to bio-probes for live cell imaging. In order to correlate structure and spectral characteristics, a photophysical and kinetic investigation has been conducted on a series of coordinatively saturated nine-coordinate europium(III) systems based on 1,4,7-triazacyclononane. We highlight that lanthanide emission is sensitive to changes in the ligand field by showing the linear dependence of total emission intensity ratios as a function of solvent polarity, for europium(III) complexes displaying an internal charge transfer (ICT) excited state. This sensitivity increases by a factor of 20 when studying changes in CPL spectra, rendering these complexes accurate probes of local polarity. Solvent polarity, solvent-specific effects, and the nature of the chromophores' coordinating donor atoms strongly influence the kinetic stability of europium(III) complexes with respect to enantiomer interconversion. Notably, we show that the choice of donor groups to coordinating to europium(III) and the nature and polarity of the solvent affects the rate of racemisation, leading to systems with very long half-lives at room temperature in non-polar media.

19.
Adv Sci (Weinh) ; 11(2): e2304698, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37946681

RESUMEN

The notion that phonons can carry pseudo-angular momentum has many major consequences, including topologically protected phonon chirality, Berry curvature of phonon band structure, and the phonon Hall effect. When a phonon is resonantly coupled to an orbital state split by its crystal field environment, a so-called vibronic bound state forms. Here, a vibronic bound state is observed in NaYbSe2 , a quantum spin liquid candidate. In addition, field and polarization dependent Raman microscopy is used to probe an angular momentum transfer of ΔJz = ±â„ between phonons and the crystalline electric field mediated by the vibronic bound stat. This angular momentum transfer between electronic and lattice subsystems provides new pathways for selective optical addressability of phononic angular momentum via electronic ancillary states.

20.
Surg Obes Relat Dis ; 20(5): 462-466, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38155076

RESUMEN

BACKGROUND: Laparoscopic sleeve gastrectomy (LSG) is the most common Bariatric procedure in the United States; however, the frequency of conversion to Roux-en-Y gastric bypass (RYGB) is unknown. OBJECTIVES: The primary aim was to determine the conversion rate over time from LSG to RYGB. The secondary objectives were to evaluate factors associated with conversion and postconversion weight loss outcomes. SETTING: Single Academic Institution, Center of Bariatric Excellence. METHODS: A retrospective analysis of all LSG from 2011 to 2020 was done. Kaplan-Meier analysis was utilized to estimate the conversion rate over time after LSG. Cox regression was utilized to identify predictors of future conversion. RESULTS: Of 875 LSGs, 46 were converted to RYGB from 2011 to 2020. Median follow-up was 2.6 years, and 7-year follow-up rate was 59.9%. The 1-year conversion rate was 1.4%, increasing to 3.8%, 9.0%, and 12.6% at 3, 5, and 7 years respectively. Female gender (hazard ratio [HR] = 4.2, P = .05) and age <55 (HR = 3.5, P = .04) were associated with greater chance of conversion. Preoperative asthma (HR = 1.7, P = .14) and gastroesophageal reflux disease (GERD) (HR = 1.5, P = .18) trended toward higher conversion but were not significant. Of those with body mass index (BMI) >35 at time of conversion, the mean total body weight loss (TBWL) was 13.0% at the time of conversion. This subgroup had additional 13.6% of TBWL 1-year after conversion. CONCLUSIONS: Conversion of LSG to RYGB increased with time to 12.6% conversion rate at 7-years. Patients with GERD prior to LSG had a nonsignificant trend toward conversion, while younger patients and females had significantly higher rates of conversion. There may be additional weight loss benefit for patients converted to RYGB.


Asunto(s)
Gastrectomía , Derivación Gástrica , Laparoscopía , Obesidad Mórbida , Pérdida de Peso , Humanos , Femenino , Masculino , Estudios Retrospectivos , Pérdida de Peso/fisiología , Derivación Gástrica/métodos , Derivación Gástrica/estadística & datos numéricos , Laparoscopía/métodos , Laparoscopía/estadística & datos numéricos , Persona de Mediana Edad , Obesidad Mórbida/cirugía , Gastrectomía/métodos , Gastrectomía/estadística & datos numéricos , Adulto , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA