Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
J Adv Nurs ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38924169

RESUMEN

AIM: To evaluate the effectiveness of utilizing the integrated pulmonary index for capnography implementation during sedation administered by nurses. DESIGN: Cluster-randomized trial. METHODS: Participants were enrolled from the interventional radiology department at an academic hospital in Canada. Nurses were randomized to either enable or disable the Integrated Pulmonary Index feature of the capnography monitor. Procedures were observed by a research assistant to collect information about alarm performance characteristics. The primary outcome was the number of seconds in an alert condition state without an intervention being applied. RESULTS: The number of seconds in an alarm state without intervention was higher in the group that enabled the integrated pulmonary index compared to the group that disabled this feature, but this difference did not reach statistical significance. Likewise, the difference between groups for the total alarm duration, total number of alarms and the total number of appropriate alarms was not statistically significant. The number of inappropriate alarms was higher in the group that enabled the Integrated Pulmonary Index, but this estimate was highly imprecise. There was no difference in the odds of an adverse event (measured by the Tracking and Reporting Outcomes of Procedural Sedation tool) occurring between groups. Desaturation events were uncommon and brief in both groups but the area under the SpO2 90% desaturation curve scores were lower for the group that enabled the integrated pulmonary index. CONCLUSION: Enabling the integrated pulmonary index during nurse-administered procedural sedation did not reduce nurses' response times to alarms. Therefore, integrating multiple physiological parameters related to respiratory assessment into a single index did not lower the threshold for intervention by nurses. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The time it takes to respond to capnography monitor alarms will not be reduced if the integrated pulmonary Iindex feature of capnography monitors is enabled during nurse-administered procedural sedation. IMPACT: Results do not support the routine enabling of the integrated pulmonary index when nurses use capnography to monitor patients during procedural sedation as a strategy to reduce the time it takes to initiate responses to alarms. REPORTING METHOD: CONSORT. PATIENT OR PUBLIC CONTRIBUTION: There was no patient or public contribution. TRIAL REGISTRATION: This study was prospectively registered at ClinicalTrials.gov (ID: NCT05068700).

2.
Health Informatics J ; 30(2): 14604582241252791, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721881

RESUMEN

Before a medical procedure requiring anesthesia, patients are required to not eat or drink non-clear fluids for 6 h and not drink clear fluids for 2 h. Fasting durations in standard practice far exceed these minimum thresholds due to uncertainties in procedure start time. The aim of this retrospective, observational study was to compare fasting durations arising from standard practice with different approaches for calculating the timepoint at which patients are instructed to stop eating and drinking. Scheduling data for procedures performed in the cardiac catheterization laboratory of an academic hospital in Canada (January 2020 to April 2022) were used. Four approaches utilizing machine learning (ML) and simulation were used to predict procedure start times and calculate when patients should be instructed to start fasting. Median fasting duration for standard practice was 10.08 h (IQR 3.5) for both food and clear fluids intake. The best performing alternative approach, using tree-based ML models to predict procedure start time, reduced median fasting from food/non-clear fluids to 7.7 h (IQR 2) and clear liquids fasting to 3.7 h (IQR 2.4). 97.3% met the minimum fasting duration requirements (95% CI 96.9% to 97.6%). Further studies are required to determine the effectiveness of operationalizing this approach as an automated fasting alert system.


Asunto(s)
Ayuno , Humanos , Estudios Retrospectivos , Factores de Tiempo , Canadá , Aprendizaje Automático/normas , Citas y Horarios , Femenino , Masculino
4.
J Clin Monit Comput ; 38(1): 121-130, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37715858

RESUMEN

The purpose of this study was to evaluate the feasibility and accuracy of remote Video Plethysmography (VPPG) for contactless measurements of blood pressure (BP) and heart rate (HR) in adult surgical patients in a hospital setting. An iPad Pro was used to record a 1.5-minute facial video of the participant's face and VPPG was used to extract vital signs measurements. A standard medical device (Welch Allyn) was used for comparison to measure BP and HR. Trial registration: NCT05165381. Two-hundred-sixteen participants consented and completed the contactless BP and HR monitoring (mean age 54.1 ± 16.8 years, 58% male). The consent rate was 75% and VPPG was 99% successful in capturing BP and HR. VPPG predicted SBP, DBP, and HR with a measurement bias ± SD, -8.18 ± 16.44 mmHg, - 6.65 ± 9.59 mmHg, 0.09 ± 6.47 beats/min respectively. Pearson's correlation for all measurements between VPPG and standard medical device was significant. Correlation for SBP was moderate (0.48), DBP was weak (0.29), and HR was strong (0.85). Most patients were satisfied with the non-contact technology with an average rating of 8.7/10 and would recommend it for clinical use. VPPG was highly accurate in measuring HR, and is currently not accurate in measuring BP in surgical patients. The VPPG BP algorithm showed limitations in capturing individual variations in blood pressure, highlighting the need for further improvements to render it clinically effective across all ranges. Contactless vital signs monitoring was well-received and earned a high satisfaction score.


Asunto(s)
Atención Perioperativa , Pletismografía , Adulto , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Presión Sanguínea/fisiología , Frecuencia Cardíaca
5.
J Clin Monit Comput ; 38(1): 47-55, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37698697

RESUMEN

The accurate recording of respiratory rate (RR) without contact is important for patient care. The current methods for RR measurement such as capnography, pneumography, and plethysmography require patient contact, are cumbersome, or not accurate for widespread clinical use. Video Plethysmography (VPPG) is a novel automated technology that measures RR using a facial video without contact. The objective of our study was to determine whether VPPG can feasibly and accurately measure RR without contact in surgical patients at a clinical setting. After research ethics approval, 216 patients undergoing ambulatory surgery consented to the study. Patients had a 1.5 min video of their faces taken via an iPad preoperatively, which was analyzed using VPPG to obtain RR information. The RR prediction by VPPG was compared to 60-s manual counting of breathing by research assistants. We found that VPPG predicted RR with 88.8% accuracy and a bias of 1.40 ± 1.96 breaths per minute. A significant and high correlation (0.87) was observed between VPPG-predicted and manually recorded RR. These results did not change with the ethnicity of patients. The success rate of the VPPG technology was 99.1%. Contactless RR monitoring of surgical patients at a hospital setting using VPPG is accurate and feasible, making this technology an attractive alternative to the current approaches to RR monitoring. Future developments should focus on improving reliability of the technology.


Asunto(s)
Pletismografía , Frecuencia Respiratoria , Humanos , Reproducibilidad de los Resultados , Monitoreo Fisiológico/métodos , Respiración
6.
BMJ Open ; 13(9): e073612, 2023 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-37770257

RESUMEN

INTRODUCTION: The ageing population has led to an increasing proportion of surgical patients with greater frailty and comorbidity. Complications and mortality within 30 days of a surgical procedure are often used to evaluate success in the perioperative period however these measures can potentially underestimate a substantial level of morbidity associated with surgery. Personal wearable technologies are now readily available and can offer detailed information on activity intensity, sedentary behaviour and sleeping patterns. These devices may provide important information perioperatively by acting as a non-invasive, and cost-efficient means to risk stratify patients. METHODS AND ANALYSIS: The Peri-Operative Wearables in Elder Recover After Surgery (POWERS) study is a multicentre observational study of 200 older adults (≥65 years) having major elective non-cardiac surgery. The objectives are to characterise the association between preoperative and postoperative activity monitor measurements with postoperative disability and recovery, as well as characterise trajectories of activity and sleep in the perioperative period. Activity will be monitored with the ActiGraph GT3X device and measured for 7-day increments, preoperatively, and at 1 week, 1 month and 3 months postoperatively. Disability will be assessed using the WHO Disability Assessment Schedule 2.0 assessed at 1 week, 1 month and 3 months postoperatively. ETHICS AND DISSEMINATION: The POWERS study received research ethics board approval at all participating sites on 1 August 2019 (REB # 19-121 (CTO 1849)). Renewal was granted on 19 May 2022.


Asunto(s)
Complicaciones Posoperatorias , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Estudios Prospectivos , Complicaciones Posoperatorias/epidemiología , Procedimientos Quirúrgicos Electivos/efectos adversos , Periodo Perioperatorio , Estudios Observacionales como Asunto , Estudios Multicéntricos como Asunto
7.
Lancet Respir Med ; 11(8): 739-754, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37475125

RESUMEN

Individuals with SARS-CoV-2 infection can develop symptoms that persist well beyond the acute phase of COVID-19 or emerge after the acute phase, lasting for weeks or months after the initial acute illness. The post-acute sequelae of COVID-19, which include physical, cognitive, and mental health impairments, are known collectively as long COVID or post-COVID-19 condition. The substantial burden of this multisystem condition is felt at individual, health-care system, and socioeconomic levels, on an unprecedented scale. Survivors of COVID-19-related critical illness are at risk of the well known sequelae of acute respiratory distress syndrome, sepsis, and chronic critical illness, and these multidimensional morbidities might be difficult to differentiate from the specific effects of SARS-CoV-2 and COVID-19. We provide an overview of the manifestations of post-COVID-19 condition after critical illness in adults. We explore the effects on various organ systems, describe potential pathophysiological mechanisms, and consider the challenges of providing clinical care and support for survivors of critical illness with multisystem manifestations. Research is needed to reduce the incidence of post-acute sequelae of COVID-19-related critical illness and to optimise therapeutic and rehabilitative care and support for patients.


Asunto(s)
COVID-19 , Adulto , Humanos , COVID-19/complicaciones , Síndrome Post Agudo de COVID-19 , SARS-CoV-2 , Enfermedad Crítica , Progresión de la Enfermedad
8.
Br J Anaesth ; 131(3): 607-616, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37208282

RESUMEN

BACKGROUND: Tracheal intubation is a high-risk procedure in the critically ill, with increased intubation failure rates and a high risk of other adverse events. Videolaryngoscopy might improve intubation outcomes in this population, but evidence remains conflicting, and its impact on adverse event rates is debated. METHODS: This is a subanalysis of a large international prospective cohort of critically ill patients (INTUBE Study) performed from 1 October 2018 to 31 July 2019 and involving 197 sites from 29 countries across five continents. Our primary aim was to determine the first-pass intubation success rates of videolaryngoscopy. Secondary aims were characterising (a) videolaryngoscopy use in the critically ill patient population and (b) the incidence of severe adverse effects compared with direct laryngoscopy. RESULTS: Of 2916 patients, videolaryngoscopy was used in 500 patients (17.2%) and direct laryngoscopy in 2416 (82.8%). First-pass intubation success was higher with videolaryngoscopy compared with direct laryngoscopy (84% vs 79%, P=0.02). Patients undergoing videolaryngoscopy had a higher frequency of difficult airway predictors (60% vs 40%, P<0.001). In adjusted analyses, videolaryngoscopy increased the probability of first-pass intubation success, with an OR of 1.40 (95% confidence interval [CI] 1.05-1.87). Videolaryngoscopy was not significantly associated with risk of major adverse events (odds ratio 1.24, 95% CI 0.95-1.62) or cardiovascular events (odds ratio 0.78, 95% CI 0.60-1.02). CONCLUSIONS: In critically ill patients, videolaryngoscopy was associated with higher first-pass intubation success rates, despite being used in a population at higher risk of difficult airway management. Videolaryngoscopy was not associated with overall risk of major adverse events. CLINICAL TRIAL REGISTRATION: NCT03616054.


Asunto(s)
Enfermedad Crítica , Laringoscopios , Humanos , Enfermedad Crítica/terapia , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Laringoscopía/efectos adversos , Laringoscopía/métodos , Estudios Prospectivos
9.
J Clin Monit Comput ; 37(5): 1327-1339, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37178234

RESUMEN

Capnography monitors trigger high priority 'no breath' alarms when CO2 measurements do not exceed a given threshold over a specified time-period. False alarms occur when the underlying breathing pattern is stable, but the alarm is triggered when the CO2 value reduces even slightly below the threshold. True 'no breath' events can be falsely classified as breathing if waveform artifact causes an aberrant spike in CO2 values above the threshold. The aim of this study was to determine the accuracy of a deep learning approach to classifying segments of capnography waveforms as either 'breath' or 'no breath'. A post hoc secondary analysis of data from 9 North American sites included in the PRediction of Opioid-induced Respiratory Depression In Patients Monitored by capnoGraphY (PRODIGY) study was conducted. We used a convolutional neural network to classify 15 s capnography waveform segments drawn from a random sample of 400 participants. Loss was calculated over batches of 32 using the binary cross-entropy loss function with weights updated using the Adam optimizer. Internal-external validation was performed by iteratively fitting the model using data from all but one hospital and then assessing its performance in the remaining hospital. The labelled dataset consisted of 10,391 capnography waveform segments. The neural network's accuracy was 0.97, precision was 0.97 and recall was 0.96. Performance was consistent across hospitals in internal-external validation. The neural network could reduce false capnography alarms. Further research is needed to compare the frequency of alarms derived from the neural network with the standard approach.


Asunto(s)
Capnografía , Aprendizaje Profundo , Humanos , Dióxido de Carbono/análisis , Respiración , Hospitales
10.
JAMA Surg ; 158(3): 235-244, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36630120

RESUMEN

Importance: Selenium contributes to antioxidative, anti-inflammatory, and immunomodulatory pathways, which may improve outcomes in patients at high risk of organ dysfunctions after cardiac surgery. Objective: To assess the ability of high-dose intravenous sodium selenite treatment to reduce postoperative organ dysfunction and mortality in cardiac surgery patients. Design, Setting, and Participants: This multicenter, randomized, double-blind, placebo-controlled trial took place at 23 sites in Germany and Canada from January 2015 to January 2021. Adult cardiac surgery patients with a European System for Cardiac Operative Risk Evaluation II score-predicted mortality of 5% or more or planned combined surgical procedures were randomized. Interventions: Patients were randomly assigned (1:1) by a web-based system to receive either perioperative intravenous high-dose selenium supplementation of 2000 µg/L of sodium selenite prior to cardiopulmonary bypass, 2000 µg/L immediately postoperatively, and 1000 µg/L each day in intensive care for a maximum of 10 days or placebo. Main Outcomes and Measures: The primary end point was a composite of the numbers of days alive and free from organ dysfunction during the first 30 days following cardiac surgery. Results: A total of 1416 adult cardiac surgery patients were analyzed (mean [SD] age, 68.2 [10.4] years; 1043 [74.8%] male). The median (IQR) predicted 30-day mortality by European System for Cardiac Operative Risk Evaluation II score was 8.7% (5.6%-14.9%), and most patients had combined coronary revascularization and valvular procedures. Selenium did not increase the number of persistent organ dysfunction-free and alive days over the first 30 postoperative days (median [IQR], 29 [28-30] vs 29 [28-30]; P = .45). The 30-day mortality rates were 4.2% in the selenium and 5.0% in the placebo group (odds ratio, 0.82; 95% CI, 0.50-1.36; P = .44). Safety outcomes did not differ between the groups. Conclusions and Relevance: In high-risk cardiac surgery patients, perioperative administration of high-dose intravenous sodium selenite did not reduce morbidity or mortality. The present data do not support the routine perioperative use of selenium for patients undergoing cardiac surgery. Trial Registration: ClinicalTrials.gov Identifier: NCT02002247.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Selenio , Adulto , Humanos , Masculino , Anciano , Femenino , Selenito de Sodio/uso terapéutico , Selenito de Sodio/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Antiinflamatorios , Método Doble Ciego
11.
PLoS One ; 18(1): e0281016, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36706107

RESUMEN

Fiberoptic intubation for a difficult airway requires significant experience. Traditionally only normal airways were available for high fidelity bronchoscopy simulators. It is not clear if training on difficult airways offers an advantage over training on normal airways. This study investigates the added value of difficult airway scenarios during virtual reality fiberoptic intubation training. A prospective multicentric randomized study was conducted 2019 to 2020, among 86 inexperienced anesthesia residents, fellows and staff. Two groups were compared: Group N (control, n = 43) first trained on a normal airway and Group D (n = 43) first trained on a normal, followed by three difficult airways. All were then tested by comparing their ORSIM® scores on 5 scenarios (1 normal and 4 difficult airways). The final evaluation ORSIM® score for the normal airway testing scenario was significantly higher for group N than group D: median score 76% (IQR 56.5-90) versus 58% (IQR 51.5-69, p = 0.0039), but there was no difference in ORSIM® scores for the difficult intubation testing scenarios. A single exposure to each of 3 different difficult airway scenarios did not lead to better fiberoptic intubation skills on previously unseen difficult airways, when compared to multiple exposures to a normal airway scenario. This finding may be due to the learning curve of approximately 5-10 exposures to a specific airway scenario required to reach proficiency.


Asunto(s)
Intubación Intratraqueal , Realidad Virtual , Humanos , Estudios Prospectivos , Anestesiólogos , Curva de Aprendizaje
12.
Anesth Analg ; 137(1): 200-208, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-36445843

RESUMEN

BACKGROUND: The high-fidelity ORSIM (Airway Simulation Ltd) and the low-fidelity wooden-block fiber-optic task trainers allow users to familiarize themselves with the psychomotor skills required to manipulate the fiber-optic scope. METHODS: This single-center study aimed to compare residents' performance of fiber-optic intubation after 2 different types of task training. Twenty-four residents with experience of <8 fiber-optic intubations were randomized to either the ORSIM or a wooden-block task trainer. In a single teaching session, the resident performed 20 fiber-optic intubations on their assigned task trainer. This implied simulator competence. In the 4 months after this training, all subjects then attempted to perform a fiber-optic intubation on an American Society of Anesthesiologists (ASA) I or II anesthetized patient whose airway was preoperatively assessed as normal. The primary outcome was the cumulative sum (CUSUM) learning curves obtained as the residents trained on their respective task trainers. Secondary outcomes included: the mean time (in seconds) to perform each of the 20 fiber-optic intubations on their assigned task trainer, the total simulator training time, global rating scale score, checklist score, and time to carina when performing fiber-optic intubation on the patient. RESULTS: The CUSUM analysis showed that the ORSIM group achieved simulator competence faster. The mean time to perform fiber-optic intubation was shorter in the ORSIM group. A 2-way analysis of variance (ANOVA) test suggests that the combined effect of group (wooden-block or ORSIM) and time is statistically significant ( P < .05).Total training time (mean, 899 s ± 440 s vs 1358 s ± 405 s; 95% confidence interval [CI], 100.46-818.54; P = .01) was also significantly better in the ORSIM group.No significant difference was found between the 2 groups ( P > 0) in terms of global rating scale, checklist score, and time to reach the carina ( P >.05) when performing the fiber-optic intubation on the patient. CONCLUSIONS: ORSIM showed superiority in terms of the CUSUM learning curve in reaching competence faster in fewer attempts. There was no statistically significant difference in residents' performance when translated to clinical practice on a patient. This information should assist course directors when choosing task trainers for fiber-optic intubation training programs.


Asunto(s)
Internado y Residencia , Médicos , Humanos , Tecnología de Fibra Óptica , Intubación Intratraqueal , Simulación por Computador , Curva de Aprendizaje , Competencia Clínica
14.
Int J Colorectal Dis ; 37(9): 1937-1944, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36002749

RESUMEN

PURPOSE: Squamous cell carcinoma of the anus (SCCA) suffers a constant increase each year in the last decades. Recent studies suggested the possibility of local excision (LE) as an option for early-stage SCAC patients. This systematic review aims to summarize the available evidence on the comparison of LE vs. chemoradiotherapy (CRT) in the treatment of early SCCA patients. METHODS: We conducted a literature review including MEDLINE/PubMed, EMBASE, SCOPUS, clinicaltrials.gov, and the Cochrane Database of Systematic Reviews through June 2022. MOOSE guidelines were followed. We used the methodological index for non-randomized studies (MINORS) tool to assess quality. Data on survival and procedure-associated costs were extracted. RESULTS: Four retrospective studies including 3323 patients were included. They were all comparative retrospective cohort studies (three were registry-based studies, either NCDB or SEER) with a MINORS score of 16-19 points. Overall survival (OS) was comparable between LE and CRT patients in three studies, with a 5-year OS of 85.3-100% in LE patients and 85-91.6% in CRT patients. One study investigated cancer-specific survival (CSS) and reported similar 5-year CSS in LE (98%) and CRT patients (96%). One investigated progression-free survival (PFS) and did not report any statistically significant difference in 5-year PFS between LE (91%) and CRT patients (83%). Only one study considered the mean costs associated with the two approaches (29,210 USD with LE and 46,350 USD with CRT). CONCLUSIONS: LE may potentially be considered a valid alternative to CRT for patients with early-stage SCAA. Results of prospective randomized long-term trials comparing LE with CRT are warranted to draw definitive conclusions and consider LE as a true cost-effective strategy for T1N0 SCCA with similar oncologic results offered by CRT, which-to date-remains the "gold standard." PROSPERO REGISTRATION: CRD42022338750.


Asunto(s)
Neoplasias del Ano , Carcinoma de Células Escamosas , Humanos , Canal Anal/patología , Neoplasias del Ano/patología , Neoplasias del Ano/cirugía , Carcinoma de Células Escamosas/cirugía , Quimioradioterapia , Estudios Prospectivos , Estudios Retrospectivos
15.
Am J Respir Crit Care Med ; 206(4): 449-458, 2022 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-35536310

RESUMEN

Rationale: Cardiovascular instability/collapse is a common peri-intubation event in patients who are critically ill. Objectives: To identify potentially modifiable variables associated with peri-intubation cardiovascular instability/collapse (i.e., systolic arterial pressure <65 mm Hg [once] or <90 mm Hg for >30 minutes; new/increased vasopressor requirement; fluid bolus >15 ml/kg, or cardiac arrest). Methods: INTUBE (International Observational Study to Understand the Impact and Best Practices of Airway Management In Critically Ill Patients) was a multicenter prospective cohort study of patients who were critically ill and undergoing tracheal intubation in a convenience sample of 197 sites from 29 countries across five continents from October 1, 2018, to July 31, 2019. Measurements and Main Results: A total of 2,760 patients were included in this analysis. Peri-intubation cardiovascular instability/collapse occurred in 1,199 out of 2,760 patients (43.4%). Variables associated with this event were older age (odds ratio [OR], 1.02; 95% confidence interval [CI], 1.02-1.03), higher heart rate (OR, 1.008; 95% CI, 1.004-1.012), lower systolic blood pressure (OR, 0.98; 95% CI, 0.98-0.99), lower oxygen saturation as measured by pulse oximetry/FiO2 before induction (OR, 0.998; 95% CI, 0.997-0.999), and the use of propofol as an induction agent (OR, 1.28; 95% CI, 1.05-1.57). Patients with peri-intubation cardiovascular instability/collapse were at a higher risk of ICU mortality with an adjusted OR of 2.47 (95% CI, 1.72-3.55), P < 0.001. The inverse probability of treatment weighting method identified the use of propofol as the only factor independently associated with cardiovascular instability/collapse (OR, 1.23; 95% CI, 1.02-1.49). When administered before induction, vasopressors (OR, 1.33; 95% CI, 0.84-2.11) or fluid boluses (OR, 1.17; 95% CI, 0.96-1.44) did not reduce the incidence of cardiovascular instability/collapse. Conclusions: Peri-intubation cardiovascular instability/collapse was associated with an increased risk of both ICU and 28-day mortality. The use of propofol for induction was identified as a modifiable intervention significantly associated with cardiovascular instability/collapse.Clinical trial registered with clinicaltrials.gov (NCT03616054).


Asunto(s)
Propofol , Choque , Enfermedad Crítica/terapia , Humanos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Propofol/uso terapéutico , Estudios Prospectivos , Choque/tratamiento farmacológico , Vasoconstrictores/uso terapéutico
16.
J Adv Nurs ; 78(7): 2245-2254, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35485238

RESUMEN

AIM: To determine if smart alarm-guided treatment of respiratory depression using the Integrated Pulmonary Index is an effective way to implement capnography during nurse-administered sedation. DESIGN: Parallel cluster-randomized trial. METHODS: Nurses will be randomized to use capnography with or without the Integrated Pulmonary Index enabled. Capnography alarm performance will be compared between nurses using capnography alone or with the Integrated Pulmonary Index enabled. The target sample size is 400 adult patients scheduled for elective procedures with nurse-administered sedation. The primary outcome is the number of seconds in an alert condition state without an intervention being applied. Secondary outcomes are alarm burden, number of appropriate alarms, number of inappropriate alarms, total duration of alert conditions, choice of alarm settings and adverse sedation events. This study has been funded since April 2021. DISCUSSION: Implementing capnography into practice for respiratory monitoring during nurse-administered sedation is considered a high priority. The Integrated Pulmonary Index shows promise as a strategy to optimize the implementation of capnography for respiratory monitoring during nurse-administered sedation. If it is found in this study that using the Integrated Pulmonary Index improves the nursing management of physiologically abnormal states during nurse-administered sedation, it would provide the high-level evidence needed to support broader use of this 'smart alarm' strategy for respiratory monitoring in practice. IMPACT: With advances in medical technology continuing to expand the indications for minimally invasive surgical techniques, the use of nurse-administered sedation during medical procedures is likely to expand in the future. The findings may be applied to other populations receiving nurse-administered sedation during medical procedures. Results from this study will help translate the usage of smart alarm-guided treatment of respiratory depression during procedural sedation. TRIAL REGISTRATION: NCT05068700.


Asunto(s)
Capnografía , Insuficiencia Respiratoria , Adulto , Capnografía/métodos , Humanos , Monitoreo Fisiológico/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto
17.
Clin Transplant ; 36(10): e14613, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35147248

RESUMEN

BACKGROUND: In the era of enhanced recovery after surgery, there is significant discussion regarding the impact of intraoperative anesthetic management on short-term outcomes following liver transplantation (LT), with no clear consensus in the literature. OBJECTIVES: To identify whether or not intraoperative anesthetic management affects short-term outcomes after liver transplantation. DATA SOURCES: Ovid MEDLINE, Embase, Scopus, Google Scholar, and Cochrane Central. METHODS: A systematic review following PRISMA guidelines was undertaken. The systematic review was registered on PROSPERO (CRD42021239758). An international expert panel made recommendations for clinical practice using the GRADE approach. RESULTS: After screening, 14 studies were eligible for inclusion in this systematic review. Six were prospective randomized clinical trials, three were prospective nonrandomized clinical trials, and five were retrospective studies. These manuscripts were reviewed to look at five questions regarding anesthetic care and its impact on short term outcomes following liver transplant. After review of the literature, the quality of evidence according to the following outcomes was as follows: intraoperative and postoperative morbidity and mortality (low), early allograft dysfunction (low), and hospital and ICU length of stay (moderate). CONCLUSIONS: For optimal short term outcomes after liver transplantation, the panel recommends the use of volatile anesthetics in preference to total intravenous anesthesia (TIVA) (Level of Evidence: Very low; Strength of Recommendation: Weak) and minimum alveolar concentration (MAC) versus bispectral index (BIS) for depth of anesthesia monitoring (Level of Evidence: Very low; Strength of Recommendation: Weak). Regarding ventilation and oxygenation, the panel recommends a restrictive oxygenation strategy targeting a PaO2 of 70-120 mmHg (10-14 kPa), a tidal volume of 6-8 ml/kg ideal body weight (IBW), administration of positive end expiratory pressure (PEEP) tailored to patient intraoperative physiology, and recruitment maneuvers. (Level of evidence: Very low; Strength of Recommendation: Strong). Finally, the panel recommends the routine use of antiemetic prophylaxis. (Level of evidence: low; Strength of Recommendation: Strong).


Asunto(s)
Anestésicos , Trasplante de Hígado , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Anestesia General
18.
J Clin Monit Comput ; 36(4): 961-973, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35119597

RESUMEN

One of the most significant limitations of oximeters is their performance under poor perfusion conditions. This systematic review examines pulse oximeter model accuracy in adults under poor perfusion conditions. A multiple database search was conducted from inception to December 2020. The inclusion criteria were as follows: (1) adult participants (> 18 years) with explicitly stated conditions that cause poor peripheral perfusion (conditions localized at the oximeter placement site; or systemic conditions, including critical conditions such as hypothermia, hypotension, hypovolemia, and vasoconstricting agents use; or experimental conditions) (2) a comparison of arterial oxygen saturation and arterial blood gas values. A total of 22 studies were included and assessed for reliability and agreement using a modified Guidelines for Reporting Reliability and Agreement Studies tool. We calculated the accuracy root mean square error from bias and precision we extracted from the studies. Most oximeters (75%) were deemed accurate in patients with poor perfusion. Modern oximeters utilizing more complex algorithms were more likely to be accurate than older models. Earlobe placement of oximeters seemed more sensitive, with greater measurement accuracy, than on fingertip placement. Only one study controlled for skin pigmentation, and none strictly followed Food and Drug Association recommendations for experiments to determine oximeter accuracy. Oximeters are accurate in poorly perfused patients, especially newer oximeter models and those placed on earlobes. Further studies are needed that examine multiple oximeter models used on a diverse selection of patients while following FDA recommendations to examine oximeter accuracy.


Asunto(s)
Oximetría , Saturación de Oxígeno , Adulto , Humanos , Oxígeno , Perfusión , Reproducibilidad de los Resultados
19.
CJEM ; 24(2): 185-194, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35041201

RESUMEN

OBJECTIVES: In the early stages of the COVID-19 pandemic, there were significant concerns about the infectious risks of intubation to healthcare providers. In response, a dedicated emergency response intubation team (ERIT) consisting of anesthesiologists and allied health providers was instituted for our emergency department (ED). Given the high-risk nature of intubations and the new interprofessional team dynamics, we sought to assess health-care provider experiences and potential areas of improvement. METHODS: Surveys were distributed to healthcare providers at the University Health Network, a quaternary healthcare centre in Toronto, Canada, which includes two urban EDs seeing over 128,000 patients per year. Participants included ED physicians and nurses, anesthesiologists, anesthesia assistants, and operating room nurses. The survey included free-text questions. Responses underwent thematic analysis using grounded theory and were independently coded by two authors to generate descriptive themes. Discrepancies were resolved with a third author. Descriptive themes were distilled through an inductive, iterative process until fewer main themes emerged. RESULTS: A total of 178 surveys were collected (68.2% response rate). Of these, 123 (69%) participated in one or more ERIT activations. Positive aspects included increased numbers of staff to assist, increased intubation expertise, improved safety, and good team dynamics within the ERIT team. Challenges included a loss of scope (primarily ED physicians and nurses) and unfamiliar workflows, perceived delays to ERIT team arrival or patient intubation, role confusion, handover concerns, and communication challenges between ED and ERIT teams. Perceived opportunities for improvement included interprofessional training, developing clear guidelines on activation, inter-team role clarification, and guidelines on handover processes post-intubation. CONCLUSIONS: Healthcare providers perceived that a novel interprofessional collaboration for intubations of COVID-19 patients presented both benefits and challenges. Opportunities for improvement centred around interprofessional training, shared decision making between teams, and structured handoff processes.


RéSUMé: OBJECTIFS: Aux premiers stades de la pandémie de COVID-19, les risques infectieux de l'intubation pour les prestataires de soins de santé ont suscité de vives inquiétudes. En réponse, une équipe d'intervention d'urgence en intubation (emergency response intubation team ERIT), composée d'anesthésistes et de prestataires de services paramédicaux, a été mise en place dans notre service d'urgence. Compte tenu de la nature à haut risque des intubations et de la nouvelle dynamique d'équipe interprofessionnelle, nous avons cherché à évaluer les expériences des prestataires de soins et les domaines d'amélioration potentiels. MéTHODES: Les questionnaires ont été distribués aux prestataires de soins de santé du University Health Network, un centre de soins de santé quaternaire de Toronto, au Canada, qui comprend deux urgences urbaines accueillant plus de 128 000 patients par an. Les participants comprenaient des médecins et des infirmiers des urgences, des anesthésistes, des assistants en anesthésie et des infirmiers de salle d'opération. Les réponses ont fait l'objet d'une analyse thématique fondée sur la théorie de la base et ont été codées indépendamment par deux auteurs afin de générer des thèmes descriptifs. Les divergences ont été résolues avec un troisième auteur. Les thèmes descriptifs ont été distillés par un processus inductif et itératif jusqu'à ce qu'un nombre réduit de thèmes principaux émerge. RéSULTATS: Au total, 178 sondages ont été recueillis (taux de réponse de 68,2 %). Parmi ceux-ci, 123 (69 %) ont participé à une ou plusieurs activations d'ERIT. Les aspects positifs comprenaient un nombre accru de personnel pour aider, une expertise accrue en matière d'intubation, une sécurité améliorée et une bonne dynamique d'équipe au sein de l'équipe ERIT. Parmi les difficultés rencontrées, citons la perte du champ d'action (principalement les médecins et les infirmières des services d'urgence) et les flux de travail non familiers, les retards perçus dans l'arrivée de l'équipe d'ERIT ou l'intubation du patient, la confusion des rôles, les problèmes de transfert et les difficultés de communication entre les équipes des services d'urgence et d'ERIT. Les possibilités d'amélioration perçues comprennent la formation interprofessionnelle, l'élaboration de directives claires sur l'activation, la clarification des rôles entre les équipes et les directives sur les processus de transfert après l'intubation. CONCLUSIONS: Les prestataires de soins de santé ont perçu qu'une nouvelle collaboration interprofessionnelle pour les intubations des patients COVID-19 présentait à la fois des avantages et des défis.


Asunto(s)
COVID-19 , COVID-19/epidemiología , COVID-19/terapia , Servicio de Urgencia en Hospital , Personal de Salud , Humanos , Intubación Intratraqueal , Pandemias , Grupo de Atención al Paciente , SARS-CoV-2
20.
J Clin Monit Comput ; 36(1): 41-54, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34240262

RESUMEN

The objective of this systematic review and meta-analysis was to analyze the effectiveness of contactless vital sign monitors that utilize a consumer-friendly camera versus medical grade instruments. A multiple database search was conducted from inception to September 2020. Inclusion criteria were as follows: studies that used a consumer-grade camera (smartphone/webcam) to examine contactless vital signs in adults; evaluated the non-contact device against a reference medical device; and used the participants' face for measurement. Twenty-six studies were included in the review of which 16 were included in Pearson's correlation and 14 studies were included in the Bland-Altman meta-analysis. Twenty-two studies measured heart rate (HR) (92%), three measured blood pressure (BP) (12%), and respiratory rate (RR) (12%). No study examined blood oxygen saturation (SpO2). Most studies had a small sample size (≤ 30 participants) and were performed in a laboratory setting. Our meta-analysis found that consumer-grade contactless vital sign monitors were accurate in comparison to a medical device in measuring HR. Current contactless monitors have limitations such as motion, poor lighting, and lack of automatic face tracking. Currently available consumer-friendly contactless monitors measure HR accurately compared to standard medical devices. More studies are needed to assess the accuracy of contactless BP and RR monitors. Implementation of contactless vital sign monitors for clinical use will require validation in a larger population, in a clinical setting, and expanded to encompass other vital signs including BP, RR, and SpO2.


Asunto(s)
Frecuencia Respiratoria , Signos Vitales , Adulto , Frecuencia Cardíaca , Humanos , Monitoreo Fisiológico , Oximetría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...