Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Diabetes Res Clin Pract ; 208: 111123, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38309532

RESUMEN

AIMS: Understanding the lived experience of using a tubeless insulin pump and how this differs compared to usual care (tubed insulin pump therapy (IPT) vs multiple daily injections (MDI)). METHODS: Interviews were conducted after 12-weeks of using the Omnipod DASH Insulin Management System (Insulet, Acton, MA) and analysed using thematic analysis. RESULTS: Fifty-eight adults (35 female; mean age 42;SD 13 years; 35 previous MDI) were interviewed. Most (84 %) wanted to continue using the device. Experiences fit two themes: 1. Taking back control of my diabetes: many previous MDI users perceived improved glycaemic control, explained by more "nuanced" control, with some reporting positive effects during exercise and sleep. Many previous MDI and IPT users endorsed positive experiences in concealing or disclosing their diabetes to others. However, some previous MDI users reported negative psychosocial experiences due to feeling continuously "attached" to their diabetes. 2. Barriers and facilitators of device acceptability: both MDI and IPT users cited wearability, alarms and the financial cost impacted their choice to continue device use. IPT users reported positive wearability experiences. CONCLUSIONS: The tubeless pump improved diabetes management perceptions for both MDI and tubed pump users. However, participants' prior glucose management affected perceptions of its advantages and disadvantages.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/psicología , Hipoglucemiantes/uso terapéutico , Australia , Insulina/uso terapéutico , Inyecciones , Sistemas de Infusión de Insulina , Glucemia
2.
J Clin Endocrinol Metab ; 109(8): 1984-1995, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38373265

RESUMEN

CONTEXT: Omnipod DASH Insulin Management System is a tubeless insulin pump that overcomes the physical inconveniences of conventional tubed insulin pump therapy (IPT). OBJECTIVE: We compared treatment satisfaction with Omnipod DASH System to usual care (multiple daily injections [MDIs] or tubed IPT) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from 4 diabetes centers in Australia were randomly assigned in a 1:1 nonblinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension during which all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire "current" (ΔDTQ-current) score at 12 weeks (study end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, and glycemic and device-related outcomes at 12 weeks (study end) and 24 weeks (end extension). RESULTS: Treatment satisfaction improved more in the Omnipod group vs the Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs 0.0 [12.8]; P < .001) at study end. Significantly greater improvements in other PROs and glycated hemoglobin A1c were also observed. Improvements in DTQ-current and other PROs comparing study end and end extension were similar. While percentage in time in range change from baseline did not differ at study end (-2.0 [12.7] %), it was significantly greater at end extension (5.6 [10.9] %; P = .016). CONCLUSION: The Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG that was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Satisfacción del Paciente , Calidad de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/instrumentación , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Insulina/administración & dosificación , Insulina/uso terapéutico , Glucemia/análisis , Hemoglobina Glucada/análisis , Resultado del Tratamiento , Australia
3.
Pilot Feasibility Stud ; 9(1): 171, 2023 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-37814352

RESUMEN

BACKGROUND: Insulin pump therapy (IPT) improves glucose control in people with type 1 diabetes (T1D) compared with multiple daily injections (MDI). However, their size, the tethered insulin infusion set, intrusiveness when operating the device and the need to disconnect during showering limit their acceptance to many who may benefit. The Omnipod DASH® Insulin Management System is a small waterproof tubeless device which is wirelessly controlled by a handheld device which may be an acceptable alternative. However, there are no randomised controlled trials focusing on the impact on user perceptions of tubeless insulin pump therapy. This pilot study aims to assess study feasibility and acceptability of patch pump therapy compared with usual care in adults with T1D in Australia to inform power calculations and progression to a large-scale multi-site randomised controlled study. METHODS: A pilot multi-site parallel randomised controlled study will be conducted in sixty-four adults with T1D who are managed on MDI or IPT and self-monitoring with finger-stick blood glucose from four specialist diabetes centres in Victoria, Australia. Following carbohydrate counting education, participants will be randomised to use Omnipod DASH® System (Omnipod group) or continue usual care (usual care group) for 12 weeks, followed by a 12-week extension phase where all participants will use Omnipod DASH® System. The primary outcome measure is feasibility determined by study completion rates with a threshold of 0.80. Acceptability of the intervention (Omnipod DASH® System) will be assessed by the difference in Diabetes Technology Questionnaire 'current' (DTQ-current) score at 12 weeks post-randomisation compared to baseline. Secondary outcomes will include other measures of user acceptance, process outcomes, resource outcomes, participant-centred outcomes, healthcare professional perceptions and glycaemic outcomes. DISCUSSION: This pilot study will provide insights regarding the feasibility of the study design and the first data regarding user acceptance of insulin patch pump technology in Australian T1D adults. We anticipate that this study will provide information informing the design of a larger study evaluating the impact of patch pumps on subjective outcomes that are of significance to the person living with T1D. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ( https://anzctr.org.au/ ) ACTRN12621001195842 (8th September 2021). Please refer to Additional file 1: Appendix 1 for full details.

4.
Resuscitation ; 187: 109787, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37028747

RESUMEN

The effective recruitment and randomisation of patients in pre-hospital clinical trials presents unique challenges. Owing to the time critical nature of many pre-hospital emergencies and limited resourcing, the use of traditional methods of randomisation that may include centralised telephone or web-based systems are often not practicable or feasible. Previous technological limitations have necessitated that pre-hospital trialists strike a compromise between implementing pragmatic, deliverable study designs, with robust enrolment and randomisation methodologies. In this commentary piece, we present a novel smartphone-based solution that has the potential to align pre-hospital clinical trial recruitment processes to that of best-in-practice in-hospital and ambulatory care based studies.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2 , Teléfono Inteligente , Proyectos de Investigación , Hospitales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...