1.
Technol Cancer Res Treat ; 16(3): 352-356, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28168935

RESUMEN

PURPOSE: Our preferred treatment for juxtapapillary choroidal melanoma is stereotactic radiotherapy. We aim to describe our immobilization system and quantify its reproducibility. MATERIALS AND METHODS: Patients were identified in our radiosurgery database. Patients were imaged at computed tomography simulator with an in-house system which allows visual monitoring of the eye as the patient fixates a small target. All patients were reimaged at least once prior to and/or during radiotherapy. The patients were treated on the CyberKnife system, 60 Gy in 10 daily fractions, using skull tracking in conjunction with our visual monitoring system. In order to quantify the reproducibility of the eye immobilization system, computed tomography scans were coregistered using rigid 6-dimensional skull registration. Using the coregistered scans, x, y, and z displacements of the lens/optic nerve insertion were measured. From these displacements, 3-dimensional vectors were calculated. RESULTS: Thirty-four patients were treated from October 2010 to September 2015. Thirty-nine coregistrations were performed using 73 scans (2-3 scans per patient). The mean displacements of lens and optic nerve insertion were 0.1 and 0.0 mm. The median 3-dimensional displacements (absolute value) of lens and nerve insertion were 0.8 and 0.7 mm (standard deviation: 0.5 and 0.6 mm). Ninety-eight percent of 3-dimensional displacements were below 2 mm (maximum 2.4 mm). The calculated planning target volume (PTV) margins were 0.8, 1.4, and 1.5 mm in the anterior-posterior, craniocaudal, and right-left axes, respectively. Following this analysis, no further changes have been applied to our planning margin of 2 to 2.5 mm as it is also meant to account for uncertainties in magnetic resonance imaging to computed tomography registration, skull tracking, and also contouring variability. CONCLUSION: We have found our stereotactic eye immobilization system to be highly reproducible (<1 mm) and free of systematic error.


Asunto(s)
Neoplasias de la Coroides/radioterapia , Neoplasias del Ojo/radioterapia , Ojo/efectos de la radiación , Radiocirugia/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Coroides/diagnóstico por imagen , Neoplasias de la Coroides/patología , Ojo/diagnóstico por imagen , Ojo/patología , Neoplasias del Ojo/diagnóstico por imagen , Neoplasias del Ojo/patología , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Radiocirugia/normas , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...