RESUMEN
BACKGROUND: A key moderator of wound healing is oxygen. Wound healing is a dynamic and carefully orchestrated process involving blood cells, cytokines, parenchymal cells (i.e. fibroblasts and mesenchymal stem cells) and extracellular matrix reorganization. Human adipose derived stem cells as well as human fibroblasts produce soluble factors, exhibit diverse effects on inflammation and anti inflammation response and are involved in wound healing processes.Hyperbaric oxygen therapy is an effective adjunct treatment for ischemic disorders such as chronic infection or chronic wounds. In vitro effects of hyperbaric oxygen therapy on human cells were presented in many studies except for those on mono- and co-cultures of human adipose derived stem cells and fibroblasts. OBJECTIVE: The aim of this study was to investigate the effects of hyperbaric oxygen therapy on mono- and co-cultures of human adipose derived stem cells and fibroblasts. METHODS: Mono- and co-cultures from human adipose derived stem cells and fibroblasts were established. These cultures were exposed to hyperbaric oxygen therapy every 24âh for five consecutive days. Measuring experiments were performed on the first, third and fifth day. Therapy effects on the expression of VEGF, IL 6 and reactive oxygen species were investigated. RESULTS: After exposure to hyperbaric oxygen, cell culturess showed a significant increase in the expression of VEGF after 3 and 5 days. All cultures showed significantly reduced formation of reactive oxygen species throughout the experiments. The expression of IL-6 decreased during the experiment in mono-cultures of human adipose derived stem cells and co-cultures. In contrast, mono-cultures of human skin fibroblasts showed an overall significantly increased expression of IL-6. CONCLUSIONS: Hyperbaric oxygen therapy leads to immunmodulatory and proangiogenetic effects in a wound-like enviroment of adipose derived stem cells and fibroblasts.
Asunto(s)
Tejido Adiposo/metabolismo , Técnicas de Cocultivo/métodos , Fibroblastos/metabolismo , Oxigenoterapia Hiperbárica/métodos , Células Madre/metabolismo , Cicatrización de Heridas/fisiología , Humanos , Estrés Oxidativo , Especies Reactivas de OxígenoRESUMEN
BACKGROUND: Fat present during blood salvage in orthopaedic or cardiac surgery can pose a risk of fat embolism and should be eliminated before transfusion. Based on observations of central fat accumulation at the bottom of Latham bowls, a fat reduction program was developed using two volume displacements, where blood temporarily is removed and respun in the bowl to force the fat through the RBC sediment. MATERIALS AND METHODS: Pooled ABO-matched RBC and FFP were adjusted to a haematocrit of 10%, and human fat tissue added to a concentration of 1·25 vol%. In six experiments, blood was processed with the new-generation cell salvage device CS Elite in a newly developed fat reduction program in bowls of three sizes. Volumetric quantification of fat was performed after centrifugation of blood samples in Pasteur pipettes. From volumes, haematocrits and the concentrations of fat, RBC recovery and fat elimination rates were calculated. RESULTS: Fat removal rates of 93·2 ± 2·8, 97·0 ± 2·1 and 99·6 ± 0·3% were observed with a 70-ml, 125-ml and 225-ml bowl, respectively, and even higher rates when removal rates were calculated one cycle. At the same time, high RBC recovery and plasma elimination rates were maintained, not significantly different to the default program mode. CONCLUSION: Modifications in process parameters and sequence led to a fat reduction program that significantly improves fat removal with the Cell Saver Elite from 77·4 ± 5·1% in the default mode to an average of 98·6 ± 1·1%, yielding results equivalent to the continuous cell salvage system (C.A.T.S).
Asunto(s)
Seguridad de la Sangre , Lípidos/aislamiento & purificación , Transfusión de Sangre Autóloga , Transfusión de Eritrocitos , Hematócrito , Humanos , Lípidos/sangreRESUMEN
BACKGROUND AND OBJECTIVES: Cell salvage plays a key role in blood conservation. To maintain high performance, quality management is recommended. Accordingly, a new-generation autotransfusion device was tested for its performance and compared with its predecessor. Two different calculations of quality parameters were applied. MATERIALS AND METHODS: In an experimental study, the continuous autotransfusion devices CATSmart and Continuous Autotransfusion System (C.A.T.S) plus were tested using banked blood adjusted to a haematocrit of 20% and anticoagulated with heparin 5 U/L. Test blood was processed using an emergency programme, a high-quality programme/smart wash programme and a low-volume wash programme. Samples were taken after the production of 200 mL of red blood cells (RBC) and after the final emptying of the separation chamber. In an additional set of tests, blood containing 1·25% fat was processed with both devices to examine fat removal. RESULTS: Both devices demonstrated an equally high performance with regards to product hematocrit (Hct); RBC recovery; and elimination rates of protein, heparin and fat. The high fat elimination rate (>99·8%) reported for C.A.T.S plus was confirmed for CATSmart, regardless of the used programme. Samples taken during the ongoing process show a higher haematocrit and RBC recovery rate than samples taken after the final emptying of the separation chamber. Interface sensors were not affected by fat in the blood. CONCLUSIONS: The new-generation autotransfusion device CATSmart is not inferior to its predecessor and shows high performance with regards to RBC recovery, plasma and fat elimination in all programme modes. Samples for quality controls should be taken during blood processing.
Asunto(s)
Transfusión de Sangre Autóloga/instrumentación , Eritrocitos , Lípidos , Control de Calidad , Transfusión de Sangre Autóloga/métodos , Hematócrito , HumanosRESUMEN
PURPOSE: Radical cystectomy (RC) can be associated with significant blood loss, whereas many patients are presenting with anemia preoperatively. To date, there is a lack of data addressing the impact of preoperative anemia (PA) on survival of patients undergoing RC for urothelial carcinoma of the bladder (UCB). METHODS: This retrospective multicenter study includes 684 patients with UCB undergoing RC with pelvic lymph node dissection. The median follow-up was 50 (IQR 29,78) months. Anemia was defined in line with the WHO classification (hemoglobin (Hb): male ≤13 g/dL, female ≤12 g/dL) and based on contemporary gender- and age-adjusted classification (Hb: white male aged <60 years: ≤13.7 g/dL; ≥60 years: ≤13.2 g/dL; white female of all ages ≤12.2 g/dL). Univariable and multivariable Cox regression analyses were used to assess the effects of PA on oncological outcomes. RESULTS: A total of 269 (39.3 %) and 302 (44.2 %) patients were anemic according to the WHO classification versus contemporary classification. Age, increased ECOG performance status, advanced tumor stages, lymph node metastasis, positive surgical margin and anemia were associated with disease recurrence (DR), cancer-specific mortality (CSM) and all-cause mortality (ACM). In multivariable analysis, anemia was an independent predictor of DR, CSM and ACM (WHO and/or contemporary classification). Blood transfusion was significantly associated with ACM in both classifications of anemia. CONCLUSIONS: PA is significantly associated with worse oncological outcome in patients undergoing RC. Based on the additional unfavorable influence of blood transfusion, this emphasizes the importance of early diagnosis and correction of anemia and implementation of alternative methods of blood volume management.
Asunto(s)
Anemia/patología , Neoplasias de la Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/cirugía , Anciano , Transfusión Sanguínea/métodos , Cistectomía/métodos , Femenino , Humanos , Escisión del Ganglio Linfático/métodos , Metástasis Linfática/patología , Masculino , Recurrencia Local de Neoplasia/patología , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
PURPOSE: Radical cystectomy (RC) can be associated with significant blood loss. Allogenic blood transfusion (ABT) may alter disease outcome because of a theoretical immunomodulatory effect. We evaluated the effects of ABT on overall survival (OS) and progression-free survival (PFS) of patients undergoing RC for urothelial carcinoma of the bladder (UCB). MATERIALS AND METHODS: This is a retrospective single-center study of 350 consecutive patients of a university health center with a median follow-up of 70.1 month. All patients underwent RC and pelvic lymph node dissection. The effect of ABT on OS and PFS was analyzed using univariable and multivariable Cox proportional hazards models. RESULTS: The overall ABT rate was 63 % (n = 219), with intraoperative blood transfusion and postoperative blood transfusion being performed in 183 patients (52 %) and 99 patients (28 %), respectively. Preoperative anemia was detected in 156 patients (45 %) with median estimated blood loss of 800 ml (IQR: 500-1,200). ABT was associated with significant decrease of OS and PFS in multivariable analyses (p < 0.001), whereas patients' prognosis worsened the more packed red blood cells (PRBC) were transfused (p < 0.001). The study is limited in part due to its retrospective design. CONCLUSIONS: We found that ABT and the number of PRBC transfused are associated with poor prognosis for UCB patients undergoing RC, whereas preoperative anemia had no influence on survival. This emphasizes the importance of surgeon's awareness for a strict indication for ABT. A prospective study will be necessary to evaluate the independent risks associated with ABT during surgical treatments.
Asunto(s)
Transfusión Sanguínea , Carcinoma/mortalidad , Carcinoma/cirugía , Cistectomía/efectos adversos , Neoplasias de la Vejiga Urinaria/mortalidad , Neoplasias de la Vejiga Urinaria/cirugía , Anciano , Anemia/complicaciones , Anemia/mortalidad , Anemia/cirugía , Carcinoma/complicaciones , Cistectomía/mortalidad , Supervivencia sin Enfermedad , Femenino , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Neoplasias de la Vejiga Urinaria/complicaciones , UrotelioRESUMEN
BACKGROUND: The aim of this study was to conduct an audit of a university inpatient pain consultation service and to examine the quality and the implementation of the recommended therapeutic measures. Factors that influenced the implementation should be identified. PATIENTS AND METHODS: All inpatients treated by the consultation service in the years 2009 and 2010 were analyzed retrospectively. Demographic patient characteristics as well as quality parameters of the consultation service and pharmacological and non-pharmacological recommendations and their implementation were analyzed. RESULTS: In total 1,048 requests for the consultation service were processed of which 39.7% of the requests were for patients with acute pain, 33.8% with chronic and 19.9% with tumor-associated pain. Measures recommended most were medication, physiotherapy and psychological treatment. Recommended medications were actually prescribed in more than 80%, physiotherapy recommended in about 75% and psychological treatment recommended in 47% of the cases. Only a few influencing factors for the implementation of the recommended measures could be identified. CONCLUSION: Many different pain states are seen in an inpatient pain consultation service. The recommendations given are implemented in most cases especially concerning the medication.
Asunto(s)
Conducta Cooperativa , Hospitalización , Comunicación Interdisciplinaria , Manejo del Dolor/métodos , Derivación y Consulta/organización & administración , Dolor Agudo/psicología , Dolor Agudo/terapia , Anciano , Analgésicos/uso terapéutico , Dolor Crónico/psicología , Dolor Crónico/terapia , Terapia Combinada , Femenino , Alemania , Adhesión a Directriz , Hospitales Universitarios , Humanos , Masculino , Persona de Mediana Edad , Clínicas de Dolor , Dimensión del Dolor , Dolor Intratable/psicología , Dolor Intratable/terapia , Modalidades de Fisioterapia/psicología , Psicoterapia , Garantía de la Calidad de Atención de Salud , Estudios RetrospectivosRESUMEN
OBJECTIVE: Frequently central venous catheter sets do not contain all necessary materials. To evaluate, if combined measures using a specially arranged central venous catheter (CVC) set result in economical and clinical advantages, we compared both cost and time differences of a CVC complete set with ECG guide wire lead and an adhesive fixation with a standard set requiring additional materials, ECG fluid column lead and surgical suture. Furthermore, quality of different ECG leads, the reliability and tolerability of the adhesive fixation was compared. METHODS: 76 elective adult surgical patients were randomly assigned to receive either a control CVC set or a test CVC complete set, which was featured by preconnected stopcocks, included sterile drapes, guide wire ECG position control, and an adhesive fixation. We performed ECG-guided placement of the central venous catheter using a guide wire lead in the test CVC set vs. fluid column lead in the control CVC set. Time was recorded for preparation phase of the nurse and the anesthetist, for the puncture phase, for the ECG position control and time for CVC fixation. Quality of ECG position control using guide wire or fluid column was determined by forming Pmax/R ratio. Costs of the complete set and the standard set with additional material were compared. RESULTS: Times for preparation of nurse and anesthetists, for ECG position control and catheter fixation were significantly shorter using the test catheter set and resulted in a total time saving of 6 min (P < 0.01). Times for sterile preparation and central venous puncture were not significantly different between the groups. ECG position control using the guide wire was successful in 37 out of 38 patients (97%) and in 34 of 38 patients (89%), respectively. Pmax/R ratio was 0.8 +/- 0.2 using the guide wire versus 0.5 +/- 0.2, respectively. There were only 2 out of 38 adhesive fixations, that had to be replaced, while the mean duration of adhesive fixation was 6.2 days (3-15 days). Avoidance of disposable materials in the test CVC set led to a significant reduction of costs compared to the control CVC set. CONCLUSION: The test CVC complete set allows a significant time saving and cost reduction in performing a central venous catheter line because of completely included disposable materials. CVC position control via guide wire needs less time and shows significantly better quality of ECG compared to fluid column ECG lead. An adhesive revealed to be a reliable CVC fixation comparable to a surgical suture.
Asunto(s)
Cateterismo Venoso Central/instrumentación , Adhesivos , Adolescente , Adulto , Anciano , Anestesia , Cateterismo Venoso Central/economía , Ahorro de Costo , Electrocardiografía , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Persona de Mediana Edad , Esterilización , SuturasRESUMEN
BACKGROUND AND OBJECTIVE: Placement of central venous catheters in patients is associated with several risks including endocardial lesions and dysrhythmias. Correct positioning of central venous catheters in the superior vena cava is essential for immediate use. The objective of a first study was to evaluate the signal quality of an intravascular electrocardiogram (ECG) during position control using a guidewire compared with the customary fluid column-based ECG system, and to assess its efficacy of correct placement of the central venous catheter. A second study tested if dysrhythmias can be avoided by intravascular ECG monitoring during catheter and guidewire advancement. METHODS: The jugular or subclavian vein of 40 patients undergoing heart surgery or who were being treated in the intensive care unit was cannulated. Intravascular ECGs were recorded during position control, and guidewire and water column lead were compared in the same patient with regard to the quality of the ECG reading and P-wave enhancement. In another 40 patients, the guidewire was inserted only 10 cm and the central venous catheter advanced under guidewire ECG control. Correct position of all the central venous catheters was confirmed by chest radiography. RESULTS: All central venous catheters were correctly positioned in the superior vena cava. For the same catheter position, the P-wave was significantly larger in the guidewire ECG than in the fluid column system. No changes in the quality of the ECG were detected when the guidewire was advanced or withdrawn by 1 cm relative to the catheter tip. Cardiac dysrhythmias were not seen during ECG-monitored advancement of the guidewire. CONCLUSIONS: ECG quality using a guidewire lead is superior to the water column-based system. Furthermore, it is independent from the exact position of the guidewire as related to the tip of the catheter. Using intravascular guidewire ECG during advancement can prevent induction of dysrhythmias.