Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Thromb Haemost ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38759975

RESUMEN

BACKGROUND: Desmopressin (DDAVP) is used in patients with moderate/mild hemophilia A (PWMHs) to increase their factor VIII (FVIII) level and, if possible, normalize it. However, its effectiveness varies between individuals. The GIDEMHA study aims to investigate the influence of F8 gene variants. MATERIAL AND METHODS: The study collected the trajectory of FVIII levels from therapeutic intravenous DDAVP tests in four French hemophilia treatment centers. A pharmacological analysis was performed associated with efficacy scores according to F8 variants: absolute and relative responses, as well as new scores: absolute duration (based on duration with FVIII ≥ 0.50 IU.mL-1) and relative duration (based on half-life). RESULTS: From enrolled 439 PWMHs, 327 had a hot-spot F8 variant (with ≥5 PWMHs). For these, the median (min-max) basal and peak FVIII were 0.20 (0.02-0.040) and 0.74 (0.14-2.18) IU.mL-1 respectively, with FVIII recovery being 3.80 IU.ml-1 (1.15-14.75). The median FVIII half-life was 3.9 hours (0.7-15.9 hours). FVIII was normalized (≥0.50 IU.mL-1) in 224/327 PWMHs (69%) and the median time with normalized FVIII was 3.9 hours (0.0-54.1 hours). Following the response profiles to DDAVP defined by the four efficacy scores, four groups of F8 variants were isolated, and then compared using survival curves with normalized FVIII (p < 0.0001): "long-lastingly effective" [p.(Glu739Lys), p.(Ser2030Asn), p.(Arg2178His), p.(Gln2208Glu), and T-stretch deletion in intron 13]; "moderately effective" [p.(Ser112Phe), p.(Ala219Thr), p.(Thr2105Ile), p.Phe2146Ser), and p.(Asp2150Asn)]; "moderately ineffective" [p.Ala81Asp), p.(Gln324Pro), p.(Tyr492His), p.(Arg612Cys), p.(Met701Val), p.(Val2035Asn), and p.(Arg2178Cys)]; and "frequently ineffective" [c.-219C > T, p.(Cys2040Tyr), p.(Tyr2169His), p.(Pro2319Leu), and p.(Arg2326Gln)]. CONCLUSION: In view of our data, we propose indications for DDAVP use in PWMH based on F8 variants for minor and major invasive procedures.

2.
Clin Chim Acta ; 551: 117611, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37865270

RESUMEN

BACKGROUND: Circulating creatinine is a biomarker of paramount importance in clinical practice. In cases of acetaminophen (APAP) intoxication, the antidote, N-acetylcysteine (NAC), interferes with commonly used creatininase-peroxidase methods. This study aimed to assess whether creatininase-amperometric methods were affected in this context. METHODS: This study includes in vitro interference tests, involving four creatinine assays using NAC-spiked plasma pools and an in vivo retrospective study comparing creatininase-peroxidase and creatininase-amperometric measurements in patients presenting with NAC-treated APAP poisoning. RESULTS: Creatininase-peroxidase method was impacted by NAC interference in a clinically-significant manner at therapeutic NAC levels (basal value recovery of 80 % and 70 % for 500 and 1000 mg.L-1 of NAC, respectively), surpassing the desirable Reference Change Value (RCV%). Enzymo-amperometric methods were not impacted. Among patients, a mean bias of -45.2 ± 28.0 % was observed for the peroxidase detection method compared to the amperometric in those who received NAC prior plasma sampling and -2.7 ± 5.4 % in those who did not. CONCLUSIONS: Our findings indicate that enzymo-amperometric creatinine assays remain unaffected by NAC interference due to the absence of the peroxidase step in the analytical process. Therefore, these methods are suitable to prevent spurious hypocreatininemia in APAP intoxicated patients undergoing NAC therapy.


Asunto(s)
Acetaminofén , Acetilcisteína , Humanos , Acetilcisteína/uso terapéutico , Creatinina , Estudios Retrospectivos , Peroxidasa , Peroxidasas
4.
Heliyon ; 9(6): e16466, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37265627

RESUMEN

Background: Bloodstream infections are a leading cause of mortality. Their detection relies on blood cultures (BCs) but time to positivity is often between tens of hours and days. d-lactate is a metabolite widely produced by bacteria but very few in human. We aimed to evaluate d-lactate, d-lactate/l-lactate ratio and d-lactate/total lactate ratio in plasma as potential early biomarkers of bacteraemia on a strictly biological standpoint. Methods: A total of 228 plasma specimens were collected from patients who had confirmed bacteraemia (n = 131) and healthy outpatients (n = 97). Specific l-lactate and d-lactate analyses were performed using enzymatic assays and analytical performances of d-lactate, d-lactate/total lactate and d-lactate/l-lactate ratios for the diagnosis of bacteraemia were assessed. Results: A preliminary in vitro study confirmed that all strains of Escherichia coli, Klebsiella pneumoniae and Staphylococcus aureus were able to produce d-lactate at significant levels. In patients, plasma d-lactate level was the most specific biomarker predicting a bacteraemia profile with a specificity and predictive positive value of 100% using a cut-off of 131 µmol.L-1. However, sensitivity and negative predictive value were rather low, estimated at 31% and 52%, respectively. d-lactate displayed an Area Under Receiver Operating Characteristic (AUROC) curve of 0.696 with a P value < 0.0001. There was no difference of d-lactate levels between BCs bottles positive for Gram-positive or Gram-negative bacteria (p = 0.55). Conclusion: d-lactate shows promise as a specific early biomarker of bacterial metabolism. The development of rapid automated assays could raise clinical applications for infectious diseases diagnosis including early bacteraemia prediction.

5.
Clin Res Hepatol Gastroenterol ; 39(5): 570-5, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25776452

RESUMEN

BACKGROUND: The treatment of HFE-related hemochromatosis, one of the most common genetic diseases, is based on phlebotomies whose tolerance is evaluated by regular monitoring of hemoglobin. Using a portable hemoglobinometer (PH) could provide an easy and fast determination of hemoglobin. Therefore, the aim of the present study was to compare, in hemochromatosis patients treated by bloodletting, the hemoglobin concentrations as assayed, on capillary blood, by a PH device and, on venous blood, by a cell counter (CC) device. METHODS: For a total period of 12 weeks duration, all patients undergoing phlebotomies in the same hospital outpatient unit had hemoglobin determinations both by the HemoCue and by the laboratory's DxH 800 Coulter. To evaluate the sensitivity and specificity of the HemoCue, patients were classified as presenting or not anemia as defined by hemoglobin level below 11 g/dl. RESULTS: Measurements of hemoglobin were performed in 122 patients. The sensitivity and specificity of PH compared to CC were 100 and 98.1%, respectively. Capillary hemoglobin by PH slightly underestimated venous hemoglobin by CC. The Pearson's correlation coefficient between PH and CC was 0.80 (P<0.0001). CONCLUSION: PH is a reliable, quick and easy technology, which can be proposed to follow-up the tolerance of venesections in hemochromatosis patients.


Asunto(s)
Anemia/diagnóstico , Hemocromatosis/terapia , Hemoglobinometría/instrumentación , Hemoglobinas/análisis , Pacientes Ambulatorios , Flebotomía , Femenino , Estudios de Seguimiento , Hemoglobinometría/métodos , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Flebotomía/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Venas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...