RESUMEN
BACKGROUND: The HeartLogic algorithm integrates data from implantable defibrillator(ICD) sensors to predict heart failure(HF) decompensation: first(S1) and third(S3) heart sounds, intrathoracic impedance, respiration rate, ratio of respiration rate to tidal volume(RSBI), and night heart rate. OBJECTIVE: This study assessed the relative changes in ICD sensors at the onset of HeartLogic alerts, their association with patient characteristics, and outcomes. METHODS: The study included 568 HF patients carrying ICDs(CRT-D,n=410) across 26 centers, with a median follow-up of 26 months. HeartLogic alerts triggered patient contact and potential treatment. RESULTS: A total of 1200 HeartLogic alerts were recorded in 370 patients. The sensor with the highest change at the alert's onset was S3 in 27% of alerts, followed by S3/S1(25%). Patients with atrial fibrillation(AF) and chronic kidney disease(CKD) at implantation had higher alert prevalence(AF,84% vs. no-AF,58%; CKD,72% vs. no-CKD,59%; p <0.05) and rate (AF,1.51/patient-year vs. no-AF,0.88/patient-year; CKD,1.30/patient-year vs. no-CKD,0.89/patient-year; p<0.05). During follow-up, 247 patients experienced more than one alert; in 85%, the sensor with the highest change varied between successive alerts. Of the 88(7%) alerts associated with HF hospitalization or death, respiration rate or RSBI(11%, p=0.007 vs. S3/S1) and night heart rate(11%, p=0.031 vs. S3/S1) were more commonly the sensors showing the highest change. Clinical events were more common with the first alert(12.6%) than subsequent alerts(5.2%,p <0.001). CONCLUSION: HeartLogic alerts are mostly triggered by changes in heart sounds, but clinical events are more linked to respiration rate, RSBI, and night heart rate. Recurrent alerts often involve different sensors, indicating diverse mechanisms of HF progression.
RESUMEN
BACKGROUND: No data have been reported on cooling characteristics and the impact of variant pulmonary vein (PV) anatomy on atrial fibrillation (AF) recurrences after POLARx cryoballoon (CB) ablation. OBJECTIVE: The purpose of this study was to analyze the impact of PV anatomy variants and cooling characteristics after CB ablation from a large multicenter prospective registry. METHODS: The primary end point was defined as 1-year absence of any atrial tachyarrhythmias (ATAs: AF/atrial flutter/atrial tachycardia). Correlation between ATA recurrences and anatomy variants/cooling characteristics were evaluated. The secondary outcome was the rate of major periprocedural complications. RESULTS: A total of 429 consecutive patients diagnosed with paroxysmal AF (83.4%) or persistent AF (peAF; 16.6%) were enrolled. Twenty-eight patients (6.6%) exhibited an anatomical variant (common ostium: 4.0%; adjunctive PV: 2.6%). Nadir temperature, thaw time, and total deflation time were different between standard PVs and PV variants. After the blanking period, over a mean of 431 ± 99 days of follow-up, 63 patients (14.7%) suffered an ATA recurrence. Patients with recurrences had both a shorter thaw time (18.5 ± 7 seconds vs 19.8 ± 7 seconds; P = .0012) and a shorter total deflation time, whereas time to isolation was longer (57.4 ± 42 seconds vs 49.1 ± 33 seconds; P = .04). Patients with anatomy variants showed a similar ATA recurrence rate (5 of 28 [17.9%]) to the standard PV anatomy group (58 of 401 [14.5%]) (P = .584), with a hazard ratio (HR) of 1.43 (95% confidence interval [CI] 0.49-4.13; log-rank, P = .4384). After adjusting for confounders, heart failure (HR 4.12; 95% CI 1.75-9.73; P = .0013) and peAF (HR 1.81; 95% CI 1.03-3.18; P = .0433) remained associated with ATA recurrence during follow-up. CONCLUSION: The POLARx CB system demonstrated long-term efficacy, along with a safe profile, in both patients with paroxysmal AF and those with peAF, regardless of the presence PV variants. Time to isolation was longer in patients with ATA recurrences during follow-up. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). CLINICALTRIALS: gov identifier: NCT03793998. Registration date: January 4, 2019.
RESUMEN
Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable cardioverter-defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Objective: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th-75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P = .045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusion: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.
RESUMEN
BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers. METHODS: A patient App to collect AF-related symptoms and general health status was proposed to all patients who underwent an index PVI-C. Patients were divided into two groups according to the utilization of the App or the non-usage. RESULTS: Out of 865 patients, 353 (41%) subjects composed the App group, and 512 (59%) composed the No-App group. Baseline characteristics were comparable between the two cohorts except for age, sex, type of AF, and body mass index. During a mean follow-up of 7.9±13.8 months, AF recurrence was found in 57/865 (7%) subjects with an annual rate of 7.36% (95% CI:5.67-9.55%) in the No-App versus 10.99% (95% CI:9.67-12.48%) in the App group, p=0.007. In total, 14,458 diaries were sent by the 353 subjects in the App group and 77.1% reported a good health status and no symptoms. In only 518 diaries (3.6%), the patients reported a bad health status, and bad health status was an independent parameter of AF recurrence during follow-up. CONCLUSIONS: The use of a web App to record AF-related symptoms was feasible and effective. Additionally, a bad health status reporting in the App was associated with AF recurrence during follow-up.
Asunto(s)
Fibrilación Atrial , COVID-19 , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Resultado del Tratamiento , Criocirugía/efectos adversos , Venas Pulmonares/cirugía , Recurrencia , Ablación por Catéter/efectos adversosRESUMEN
INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Criocirugía/métodos , Italia/epidemiología , Sistema de Registros , Ablación por Catéter/métodos , RecurrenciaRESUMEN
INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.
Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Disfunción Ventricular Izquierda , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Disfunción Ventricular Izquierda/terapiaRESUMEN
The risk of microbial air contamination in a dental setting, especially during aerosol-generating dental procedures (AGDPs), has long been recognized, becoming even more relevant during the COVID-19 pandemic. However, individual pathogens were rarely studied, and microbial loads were measured heterogeneously, often using low-sensitivity methods. Therefore, the present study aimed to assess microbial air contamination in the dental environment, identify the microorganisms involved, and determine their count by active air sampling at the beginning (T0), during (T1), and at the end (T2) of ultrasonic scaling in systemically and periodontally healthy subjects. Air microbial contamination was detected at T0 in all samples, regardless of whether the sample was collected from patients treated first or later; predominantly Gram-positive bacteria, including Staphylococcus and Bacillus spp. and a minority of fungi, were identified. The number of bacterial colonies at T1 was higher, although the species found were similar to that found during the T0 sampling, whereby Gram-positive bacteria, mainly Streptococcus spp., were identified. Air samples collected at T2 showed a decrease in bacterial load compared to the previous sampling. Further research should investigate the levels and patterns of the microbial contamination of air, people, and the environment in dental settings via ultrasonic scaling and other AGDPs and identify the microorganisms involved to perform the procedure- and patient-related risk assessment and provide appropriate recommendations for aerosol infection control.
Asunto(s)
COVID-19 , Ultrasonido , Humanos , Voluntarios Sanos , Pandemias , Aerosoles y Gotitas Respiratorias , Microbiología del Aire , Recuento de Colonia MicrobianaRESUMEN
BACKGROUND: The risk of complications has been shown to be lower with subcutaneous implantable defibrillator (S-ICD) than with conventional ICDs. Given the low frequency of complications, experience of how to manage them is limited. In this paper, we describe generator- and lead-related complications recorded in a series of S-ICD patients, and we propose our conservative approach to managing them. METHODS: The study cohort consisted of S-ICD patients who were referred to our institution owing to generator- or lead-related complications requiring surgical intervention. With our "shift and cover" approach, the system component involved is moved from its original position to an alternative, more protected location. In the case of the generator, this involves moving it to an intermuscular pocket. In the case of infections at the parasternal scar, the electrode sleeve is moved away from its original location, stitched, and then covered with the muscular fascia. RESULTS: Fourteen S-ICD patients were referred to our institution owing to system-related complications. Complications involved the generator in 7 cases (deep pocket infections with erosion, extrusion, or pain), the lead in 5 cases (parasternal infections at the xyphoid incision site), and both the generator and the lead in 2 cases. Complications were managed without completely removing the device and resolved in a single surgical session with no intraoperative complications. During defibrillation testing, the first shock at 65 J was effective in all patients. The shock impedance after revision was significantly lower than that measured during first implantation (59 ± 10 Ohm versus 86 ± 24 Ohm, P = 0.013). In all cases, the cosmetic result was satisfactory. No complications or recurrent infections were reported at the 12-month follow-up visit. CONCLUSIONS: The proposed conservative approach was successful in managing S-ICD complications. The revision procedure allowed to optimize the system configuration in terms of the defibrillation vector, resulting in lower shock impedance values and better device positioning.
RESUMEN
BACKGROUND: Transvenous pacing is nowadays the cornerstone of interventional management of bradyarrhythmias. It is still associated, however, with significant complications, mostly related to indwelling transvenous leads or device pocket. In order to reduce these complications, leadless pacemakers have been recently introduced into clinical practice, but no guidelines are yet available to indicate who are those patients that might benefit the most and whether leadless pacing should be preferred in the old or young population. This survey aims to describe the use of leadless pacemaker devices in a real-world setting. METHODS: Eleven arrhythmia centers in the Lombardy region (out of a total of 17 participating centers) responded to the proposed questionnaire regarding patient characteristics and indications to leadless pacing. RESULTS: Out of a total of 411 patients undergoing leadless pacing during 4.2 ± 0.98 years, the median age was 77 years, with 0.18% of patients having less than 18 years, 29.9% 18-65 years, 34.3% 65-80 years and 35.6% >80 years. The most common indication was slow atrial fibrillation (49% of patients), followed by atrioventricular block and sinoatrial dysfunction. Two centers reported in-hospital complications. CONCLUSIONS: Leadless pacemakers proved to be a safe pacing strategy actually destined mostly to elderly patients.
Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Anciano , Bloqueo Atrioventricular/terapia , Diseño de Equipo , Humanos , Encuestas y CuestionariosRESUMEN
A 78 year-old patient with postischaemic dilated cardiomyopathy and severely reduced ejection fraction was implanted with a Boston Scientific RESONATE X4 CRT-D and followed by LATITUDE remote monitoring platform. From the end of January to the end of March 2021 he was hospitalized for COVID19 pneumonia followed by two episodes of acute heart decompensation with bilateral pleural effusion. We remotely followed the patient and identified a typical Heart Logic sensor pattern linked to the COVID19 pneumonia, different from the one linked to the heart failure (HF). We eventually made a literature review on the topic.
Asunto(s)
COVID-19 , Cardiomiopatía Dilatada , Insuficiencia Cardíaca , Anciano , Cardiomiopatía Dilatada/complicaciones , Insuficiencia Cardíaca/etiología , Hospitalización , Humanos , MasculinoRESUMEN
BACKGROUND: In heart failure (HF) patients, atrial fibrillation (AF) is associated with a worse prognosis. Implantable cardioverter-defibrillator (ICD) diagnostics allow continuous monitoring of AF and are equipped with algorithms for HF monitoring. OBJECTIVE: We evaluated the association between the values of the multisensor HF HeartLogic index and the incidence of AF, and assessed the performance of the index in detecting follow-up periods of significantly increased AF risk. METHODS: The HeartLogic feature was activated in 568 ICD patients. Median follow-up was 25 months [25th-75th percentile (15-35)]. The HeartLogic algorithm calculates a daily HF index and identifies periods of IN-alert state on the basis of a configurable threshold. The endpoints were daily AF burden ≥5 minutes, ≥6 hours, and ≥23 hours. RESULTS: The HeartLogic index crossed the threshold value 1200 times. AF burden ≥5 minutes/day was documented in 183 patients (32%), ≥6 hours/day in 118 patients (21%), and ≥23 hours/day in 89 patients (16%). The weekly time of IN-alert state was independently associated with AF burden ≥5 minutes/day (hazard ratio [HR] 1.95; 95% confidence interval [CI] 1.22-3.13; P = .005), ≥6 hours/day (HR 2.66; 95% CI 1.60-4.44; P <.001), and ≥23 hours/day (HR 3.32; 95% CI 1.83-6.02; P <.001), after correction for baseline confounders. Comparison of the episode rates in the IN-alert state with those in the OUT-of-alert state yielded HR ranging from 1.57 to 3.11 for AF burden from ≥5 minutes to ≥23 hours. CONCLUSIONS: The HeartLogic alert state was independently associated with AF occurrence. The intervals of time defined by the algorithm as periods of increased risk of HF allow risk stratification of AF according to various thresholds of daily burden.
Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Monitoreo FisiológicoAsunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Ensayo de Materiales , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Estudios de Casos y Controles , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Seguridad de Equipos , Femenino , Humanos , Italia , Masculino , Seguridad del Paciente , Puntaje de Propensión , Diseño de Prótesis , Falla de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Insuficiencia del TratamientoRESUMEN
BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.
Asunto(s)
Fibrilación Atrial/prevención & control , Fibrilación Atrial/cirugía , Ablación por Catéter , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Sistema de RegistrosRESUMEN
BACKGROUND: Coronavirus disease 2019 (COVID-19) has shown high morbidity and mortality and the relationship between pulmonary embolism (PE) and COVID-19 is well established in the literature. METHODS: We describe the characteristics of a cohort of COVID-19 patients (EP-COV) hospitalized at our Centre with PE, investigating how COVID-19 may have influenced their outcomes, as compared to patients without COVID-19 hospitalized for PE in the same months of 2020 (EP-2020) and 2019 (EP-2019). RESULTS: EP-COV patients (n=25) were younger (60.5 ± 8.5 vs 71.4 ± 14.5 vs 70.9 ± 11.8 years, p=0.003), more frequently male (76% vs 48% vs 35%, p=0.016), with a lower history of neoplasia (12% vs 47% vs 40%, p=0.028) and more clinically severe (SOFA score 3.4 ± 1.4 vs 2.2 ± 1.4 vs 1 ± 1.1, p<0.001 and PaO2/FiO2 ratio 223.8 ± 75.5 vs 306.5 ± 49.3 vs 311.8 ± 107.5) than EP-2020 (n=17) and EP-2019 patients (n=20). D-dimer and C-reactive protein were higher in EP-COV (p=0.038 e p<0.001, respectively). The rate of concomitant deep vein thrombosis associated with PE did not differ significantly between the three groups. EP-COV patients developed PE more frequently during in-hospital stay than non-COVID-19 patients (p = 0.016). The mortality rate was higher in EP-COV than in EP-2020 and EP-2019 patients (36% vs 0% vs 5%, p=0.019). CONCLUSIONS: In our study, the risk factors for PE in COVID-19 patients seem to differ from the traditional risk factors for venous thromboembolism; EP-COV patients are clinically more severe and display a higher mortality rate than EP-2020 and EP-2019 patients.
Asunto(s)
COVID-19 , Embolia Pulmonar , Tromboembolia Venosa , Anciano , COVID-19/complicaciones , COVID-19/diagnóstico , Femenino , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Embolia Pulmonar/epidemiología , Embolia Pulmonar/etiología , SARS-CoV-2RESUMEN
PURPOSE OF REVIEW: Catheter ablation of atrial fibrillation in heart failure seems to be the way to improve the quality of life, life expectance, and prognosis. In this review, we outline the growing role of this therapy and which patients can benefit from it. RECENT FINDINGS: While previous studies comparing rate control and rhythm control had not demonstrated the superiority of rhythm control in the prognosis of patients with atrial fibrillation and heart failure, recent findings seem to demonstrate that catheter ablation of atrial fibrillation reduces mortality and hospitalization for heart failure and improves the quality of life, when compared to medical therapy alone. An early rhythm-control strategy in atrial fibrillation may reduce cardiovascular death, stroke, hospitalization for HF, or acute coronary syndrome. Catheter ablation in heart failure is an effective and safe solution to obtain a rhythm control and, therefore, to improve outcomes. A better selection of the patients could help to avoid futile procedures and to identify patients requiring a closer follow-up, to redo procedures, or the addition of antiarrhythmic drugs.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Humanos , Calidad de VidaRESUMEN
BACKGROUND: More and more heart failure (HF) patients aged ≥ 75 years undergo cardiac resynchronization therapy (CRT) device implantation, however the data regarding the outcomes and their predictors are scant. We investigated the mid- to long-term outcomes and their predictors in CRT patients aged ≥ 75 years. METHODS: Patients in the Cardiac Resynchronization Therapy Modular (CRT MORE) Registry were divided into three age-groups: <65 (group A), 65-74 (group B) and ≥75 years (group C). Mortality, hospitalization, and composite event rate were evaluated at 1 year and during long-term follow-up. RESULTS: Patients (n = 934) were distributed as follows: group A 242; group B 347; group C 345. On 12-month follow-up examination, 63% of patients ≥ 75 years displayed a positive clinical response. Mortality was significantly higher in patients ≥ 75 years than in the other two groups, although the rate of hospitalizations for HF worsening was similar to that of patients aged 65-74 (7 vs. 9.5%, respectively; p = 0.15). Independent predictors of death and of negative clinical response were age >80 years, chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD). Over long-term follow-up (1020 days (IQR 680-1362)) mortality was higher in patients ≥ 75 years than in the other two groups. Hospitalization and composite event rates were similar in patients ≥ 75 years and those aged 65-74 (9 vs. 11.8%; p = 0.26, and 26.7 vs. 20.5%; p = 0.06). CONCLUSION: Positive clinical response and hospitalization rates do not differ between CRT recipients ≥ 75 years and those aged 65-74. However, age > 80 years, COPD and CKD are predictors of worse outcomes.
RESUMEN
BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Impedancia Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
AIM: To evaluate the current interpretation of the lower doses of direct oral anticoagulants (DOAC) dabigatran, apixaban, edoxaban and rivaroxaban in nonvalvular atrial fibrillation. METHODS: A questionnaire of 14 statements to which the possible answers were fully agree/partially agree/partially disagree/fully disagree or yes/no was prepared within the board of the Italian Atherosclerosis, Thrombosis and Vascular Biology Study Group and forwarded to individual Italian physicians. RESULTS: A total of 620 complete questionnaires were received from nearly all the Italian regions and physicians of various medical specialists, either enabled or not for the prescription of DOAC. A wide agreement was found as regards the pharmacological, as well as clinical consequences of the administration of the lower dose of factor-Xa inhibitors both in patients with and without clinical and/or laboratory criteria requiring dose reduction. Wide agreement was also found as regards the presence of moderate kidney insufficiency in selecting the dose of DOAC. Instead, more debated were issues regarding the proportionality between dabigatran dose and plasma concentration and selection of dabigatran dose, as well as the role of measuring drug plasma concentration and/or determine the anticoagulant activity of factor-Xa inhibitors when used at the lower dose. CONCLUSION: The interpretation of the lower doses of DOAC in current Italian clinical practice appears largely correct and shared. Because of the persistence of some residual uncertainties, essentially regarding dabigatran, however, continuous educational effort still appears warranted.
Asunto(s)
Anticoagulantes/administración & dosificación , Aterosclerosis/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Inhibidores del Factor Xa/administración & dosificación , Trombosis/diagnóstico , Administración Oral , Aterosclerosis/etiología , Aterosclerosis/prevención & control , Fibrilación Atrial/complicaciones , Dabigatrán/administración & dosificación , Relación Dosis-Respuesta a Droga , Humanos , Italia , Pirazoles/administración & dosificación , Piridinas/administración & dosificación , Piridonas/administración & dosificación , Insuficiencia Renal/complicaciones , Rivaroxabán/administración & dosificación , Encuestas y Cuestionarios , Tiazoles/administración & dosificación , Trombosis/etiología , Trombosis/prevención & control , Resultado del TratamientoRESUMEN
BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.