Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Endosc Int Open ; 12(6): E812-E817, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38911014

RESUMEN

Background and study aims Endoscopic through-the-scope clips (TTSC) are used for hemostasis and closure. We documented the performance of a new TTSC with anchor prongs. Patients and methods We conducted a prospective case series of the new TTSC in 50 patients with an indication for endoscopic clipping at three hospitals in the United States and Canada. Patients were followed for 30 days after the index procedure. Outcomes included defect closure and rate of serious adverse events (SAEs) related to the device or procedure. Results Fifty patients had 56 clipping procedures. Thirty-four procedures were clipping after endoscopic mucosal resection (EMR) in the colon (33) or stomach (1), 16 after polypectomy, two for hemostasis of active bleeding, and one each for fistula closure, per-oral endoscopic myotomy mucosal closure, or anchoring a feeding tube. Complete defect closure was achieved in 32 of 33 colon EMR defects and 21 of 22 other defects. All clips were placed per labeled directions for use. In 41 patients (82.0%), prophylaxis of delayed bleeding was reported as an indication for endoscopic clipping. There were three instances of delayed bleeding. There were no device-related SAEs. The only technical difficulty was one instance of premature clip deployment. Conclusions A novel TTSC with anchor prongs showed success in a range of defect closures, an acceptable safety profile, and low incidence of technical difficulties.

2.
Gastrointest Endosc ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38879045

RESUMEN

BACKGROUND AND AIMS: Endoscopic submucosal dissection (ESD) is a technically challenging resection technique for en-bloc removal of dysplastic and early cancerous gastrointestinal (GI) lesions. We conducted a single-arm retrospective study evaluating the safety and efficacy of a new through-the-needle injection-capable electrosurgical knife used in upper and lower ESD procedures performed at 6 US academic centers. METHODS: Data were retrospectively collected on consecutive cases in which the new ESD knife was used. The primary efficacy endpoint was successful ESD (en bloc resection with negative margins). Secondary efficacy endpoints included en-bloc resection rate, curative resection rate, median ESD time, and median dissection speed. The safety endpoint was device- or procedure-related serious adverse events (SAEs). RESULTS: ESD of 581 lesions in 579 patients were reviewed, including 187 (32.2%) upper GI and 394 (67.8%) lower GI lesions. Prior treatment was reported in 283 (48.9%) patients. Successful ESD was achieved in 477 (82.1% of 581) lesions ‒ lower for patients with versus without submucosal fibrosis (73.6% versus 87.0%, respectively, P < 0.001), but similar for those with versus without previous treatment (81.7% versus 82.3%, respectively, P = 0.848). Four hundred and forty-three (76.2% of 581) lesions met criteria for curative resection. Median ESD time was 1.0 (range 0.1-4.5) hour. Median dissection speed was 17.1 (IQR 5.3-29.8) cm2/hour. Related SAEs were reported in 15 (2.6%) patients, including delayed hemorrhage (1.9%), perforation (0.5%), or postpolypectomy syndrome (0.2%). CONCLUSION: A newly developed through-the-needle injection-capable ESD knife showed a good success rate and excellent safety at US centers. (ClinicalTrials.gov number, NCT04580940).

3.
Endosc Int Open ; 12(2): E237-E244, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38362361

RESUMEN

Background and study aims Patients with primary sclerosing cholangitis (PSC) have a 9% to 20% lifetime incidence of cholangiocarcinoma (CCA). Per-oral cholangioscopy (POCS) added to endoscopic retrograde cholangiography (ERC) could potentially improve detection of CCA occurrence. We prospectively assessed POCS identification of 12-month CCA incidence in PSC patients undergoing ERC. Patients and methods Consecutive patients with PSC, an indication for ERC, and no prior liver transplantation were enrolled. During the index procedure, POCS preceded planned therapeutic maneuvers. The primary endpoint was ability for POCS visualization with POCS-guided biopsy to identify CCA during 12-month follow-up. Secondary endpoints included ability of ERC/cytology to identify CCA, repeat ERC, liver transplantation, and serious adverse events (SAEs). Results Of 42 patients enrolled, 36 with successful cholangioscope advancement were analyzed. Patients had a mean age 43.5±15.6 years and 61% were male. Three patients diagnosed with CCA had POCS visualization impressions of benign/suspicious/suspicious, and respective POCS-guided biopsy findings of suspicious/positive/suspicious for malignancy at the index procedure. The three CCA cases had ERC visualization impressions of benign/benign/suspicious, and respective cytology findings of atypical/atypical/suspicious for malignancy. No additional patients were diagnosed with CCA during median 11.5-month follow-up. Twenty-three repeat ERCs (5 including POCS) were performed in 14 patients. Five patients had liver transplantation, one after CCA diagnosis and four after benign cytology at the index procedure. Three patients (7.1%) had post-ERC pancreatitis. No SAEs were POCS-related. Conclusions In PSC patients, POCS visualization/biopsy and ERC/cytology each identified three cases of CCA. Some patients had a repeat procedure and none experienced POCS-related SAEs.

4.
Endoscopy ; 55(12): 1103-1114, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37463599

RESUMEN

BACKGROUND: The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. METHODS: 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). RESULTS: Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3-4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. CONCLUSIONS: In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Pancreatitis , Adulto , Masculino , Humanos , Femenino , Colangiopancreatografia Retrógrada Endoscópica/métodos , Duodenoscopios/efectos adversos , Endoscopía Gastrointestinal , Pancreatitis/etiología
5.
Ann Surg ; 277(5): e1072-e1080, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35129503

RESUMEN

OBJECTIVE: We evaluated a protocolized endoscopic necrosectomy approach with a lumen-apposing metal stent (LAMS) in patients with large symptomatic walled-off pancreatic necrosis (WON) comprising significant necrotic content, with or without infection. SUMMARY BACKGROUND DATA: Randomized trials have shown similar efficacy of endoscopic treatment compared with surgery for infected WON. DESIGN: We conducted a regulatory, prospective, multicenter single-arm clinical trial examining the efficacy and safety of endoscopic ultrasound -guided LAMS with protocolized necrosectomy to treat symptomatic WON ≥6 cm in diameter with >30% solid necrosis. After LAMS placement, protocolized WON assessment was conducted and endoscopic necrosectomy was performed for insufficient WON size reduction and persistent symptoms. Patients with radiographic WON resolution to ≤ 3 cm and/or 60-day LAMS indwell had LAMS removal, then 6-month follow-up. Primary endpoints were probability of radiographic resolution by 60 days and procedure-related serious adverse events. RESULTS: Forty consecutive patients were enrolled September 2018 to March 2020, of whom 27 (67.5%) were inpatients and 19 (47.5%) had clinical evidence of infection at their index procedure. Mean WON size was 15.0 ± 5.6 cm with mean 53.2% ± 16.7% solid necrosis. Radiographic WON resolution was seen in 97.5% (95% CI, 86.8%, 99.9%) by 60 days, without recurrence in 34 patients with 6-month follow-up data. Mean time to radiographic WON resolution was 34.1 ± 16.8 days. Serious adverse events occurred in 3 patients (7.5%), including sepsis, vancomycin-resistant enterococcal bacteremia and shock, and upper gastrointestinal bleeding. There were no procedure-related deaths. CONCLUSIONS: Endoscopic ultrasound-guided drainage with protocolized endoscopic necrosectomy to treat large symptomatic or infected walled-off necrotic pancreatic collections was highly effective and safe. Clinicaltrials.-gov no: NCT03525808.


Asunto(s)
Pancreatitis Aguda Necrotizante , Humanos , Drenaje/métodos , Endosonografía , Metales , Necrosis/etiología , Necrosis/cirugía , Pancreatitis Aguda Necrotizante/diagnóstico por imagen , Pancreatitis Aguda Necrotizante/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
6.
Ann Surg ; 278(3): e556-e562, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36537290

RESUMEN

OBJECTIVE: To evaluate the safety and efficacy of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) using a lumen-apposing metal stent (LAMS). BACKGROUND: For patients with acute cholecystitis who are poor surgical candidates, EUS-GBD using a LAMS is an important treatment alternative to percutaneous gallbladder drainage. METHODS: We conducted a regulatory-compliant, prospective multicenter trial at 7 tertiary referral centers in the United States of America and Belgium. Thirty consecutive patients with mild or moderate acute cholecystitis who were not candidates for cholecystectomy were enrolled between September 2019 and August 2021. Eligible patients had a LAMS placed transmurally with 30 to 60-day indwell if removal was clinically indicated, and 30-day follow-up post-LAMS removal. Endpoints included days until acute cholecystitis resolution, reintervention rate, acute cholecystitis recurrence rate, and procedure-related adverse events (AEs). RESULTS: Technical success was 93.3% (28/30) for LAMS placement and 100% for LAMS removal in 19 patients for whom removal was attempted. Five (16.7%) patients required reintervention. Mean time to acute cholecystitis resolution was 1.6±1.5 days. Acute cholecystitis symptoms recurred in 10.0% (3/30) after LAMS removal. Five (16.7%) patients died from unrelated causes. Procedure-related AEs were reported to the FDA in 30.0% (9/30) of patients, including one fatal event 21 days after LAMS removal; however, no AEs were causally related to the LAMS. CONCLUSIONS: For selected patients with acute cholecystitis who are at elevated surgical risk, EUS-GBD with LAMS is an alternative to percutaneous gallbladder drainage. It has high technical and clinical success, with low recurrence and an acceptable AE rate. Clinicaltrials.gov, Number: NCT03767881.


Asunto(s)
Colecistitis Aguda , Vesícula Biliar , Humanos , Vesícula Biliar/diagnóstico por imagen , Vesícula Biliar/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Colecistitis Aguda/diagnóstico por imagen , Colecistitis Aguda/cirugía , Endosonografía , Drenaje/efectos adversos , Stents , Ultrasonografía Intervencional
7.
Gastrointest Endosc ; 97(3): 472-481.e3, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36208796

RESUMEN

BACKGROUND AND AIMS: Fully covered self-expandable metal stents (FCSEMSs) may offer a treatment option for pain associated with a dilated pancreatic duct (PD) in chronic pancreatitis (CP), but optimal patient selection and FCSEMS design, efficacy, and safety remain uncertain. We studied an investigational pancreatic FCSEMS for treatment of CP-associated pain. METHODS: Patients with painful CP, a dominant distal PD stricture, and PD dilation upstream were enrolled in a prospective, multicenter, single-arm trial studying 6-month indwell of a 4- to 6-cm-long soft pancreatic FCSEMS. Primary efficacy and safety endpoints were pain reduction 6 months after FCSEMS indwell (performance goal ≥53%) and PD stenting-related serious adverse events (SAEs), respectively (performance goal <32%). The primary efficacy endpoint was assessed in patients with sufficiently severe and frequent pain at FCSEMS placement as a first stent or in exchange of a plastic stent. RESULTS: Among 67 patients (mean age, 52.7 ± 12.5 years; mean time since CP diagnosis, 6.4 ± 6.4 years), 34 (50.7%) had plastic stent placement within 90 days of FCSEMS placement, and 46 patients were eligible for the primary efficacy endpoint analysis. Technical success was 97.0% (65/67). The observed primary efficacy (26.1%, 12/46) and safety endpoints (31.3%, 21/67) failed to meet the a priori study hypotheses. Study stent migration occurred in 47.7% of patients (31/65). CONCLUSIONS: Six-month treatment with an FCSEMS did not lead to an expected degree of pain reduction, and migrations and SAEs were common. Further study is needed to clarify optimal decompressive strategy, FCSEMS design, and patient selection. (Clinical trial registration number: NCT02802020.).


Asunto(s)
Enfermedades Gastrointestinales , Pancreatitis Crónica , Stents Metálicos Autoexpandibles , Humanos , Adulto , Persona de Mediana Edad , Anciano , Conductos Pancreáticos , Constricción Patológica/terapia , Constricción Patológica/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Stents Metálicos Autoexpandibles/efectos adversos , Pancreatitis Crónica/complicaciones , Stents/efectos adversos , Enfermedades Gastrointestinales/etiología , Dolor/etiología , Plásticos , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos
8.
Sci Rep ; 12(1): 20275, 2022 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-36434034

RESUMEN

This study assessed a new natural orifice transluminal endoscopic surgery (NOTES) bariatric endoscopic procedure in obese adult pigs. This 14-week prospective study compared 6 adult male Yucatan test pigs with baseline mean age 1.5 years to 2 control pigs. The test pigs received a fully endoscopic NOTES-based duodenal-jejunal bypass including measurement of the bypassed limb and creation of a gastrojejunal anastomosis (GJA) using a gastrojejunal lumen-apposing metal stent (GJ-LAMS) at Week 0, placement of a duodenal exclusion device (DED) at Week 2, and endoscopic examinations at Weeks 6 and 10. At Week 14, the pigs were sacrificed for necropsy. All endoscopic procedures were technically successful. By Week 14, the controls had gained a mean 1.1 ± 2.1 kg (+ 1.6%) while the intervention animals lost a mean 6.8 ± 3.9 kg (- 10.5%) since baseline. GJ-LAMS migrations occurred in 3 pigs, two of which also had DED migration and/or partial dislocation. Two other pigs died, one with aberrant splenic vein positioning near the GJA and the other from an unknown cause. An endoscopic bariatric bypass procedure with controlled bypass length was technically successful in all the cases and led to weight loss in test animals. Safety concerns must be further addressed.


Asunto(s)
Bariatria , Derivación Gástrica , Cirugía Endoscópica por Orificios Naturales , Masculino , Porcinos , Animales , Proyectos Piloto , Estudios de Factibilidad , Derivación Gástrica/métodos , Estudios Prospectivos , Obesidad/cirugía , Cirugía Endoscópica por Orificios Naturales/métodos
9.
Endosc Int Open ; 10(6): E874-E897, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35692924

RESUMEN

Background and study aims Malignant disease accounts for up to 80 % of gastric outlet obstruction (GOO) cases, which may be treated with duodenal self-expanding metal stents (SEMS), surgical gastrojejunostomy (GJ), and more recently endoscopic-ultrasound-guided gastroenterostomy (EUS-GE). These three treatments have not been compared head-to-head in a randomized trial. Methods We searched the Embase and MEDLINE databases for studies published January 2015-February 2021 assessing treatment of malignant GOO using duodenal SEMS, endoscopic (EUS-GE) or surgical (laparoscopic or open) GJ. Efficacy outcomes assessed included technical and clinical success rates, GOO recurrence and reintervention. Safety outcomes included procedure-related bleeding or perforation, and stent-related events for the duodenal SEMS and EUS-GE arms. Results EUS-GE had a lower rate of technical success (95.3%) than duodenal SEMS (99.4 %) or surgical GJ (99.9%) ( P  = 0.0048). For duodenal SEMS vs. EUS-GE vs. surgical GJ, rates of clinical success (88.9 % vs. 89.0 % vs. 92.3 % respectively, P  = 0.49) were similar. EUS-GE had a lower rate of GOO recurrence based on limited data ( P  = 0.0036), while duodenal SEMS had a higher rate of reintervention ( P  = 0.041). Overall procedural complications were similar (duodenal SEMS 18.7 % vs. EUS-GE 21.9 % vs. surgical GJ 23.8 %, P  = 0.32), but estimated bleeding rate was lowest ( P  = 0.0048) and stent occlusion rate was highest ( P  = 0.0002) for duodenal SEMS. Conclusions Duodenal SEMS, EUS-GE, and surgical GJ showed similar clinical efficacy for the treatment of malignant GOO. Duodenal SEMS had a lower procedure-related bleeding rate but higher rate of reintervention.

10.
Obes Surg ; 32(7): 2280-2288, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35469079

RESUMEN

PURPOSE: Bariatric endoscopic procedures are emerging as alternatives to bariatric surgical procedures. This study aimed to assess if a natural orifice transluminal endoscopic surgery (NOTES) bariatric procedure could be converted to a surgical duodenal-jejunal bypass (DJB) or sleeve gastrectomy (SG). MATERIALS AND METHODS: This 12-week prospective study compared 4 test pigs to 3 control (no procedures) pigs aged 3 months at baseline. The test pigs received a fully endoscopic NOTES-based bypass including measurement of the bypassed limb and creation of a gastrojejunal anastomosis (GJA) using gastrojejunal lumen-apposing metal stents (GJ-LAMS) at Week 0, placement of a duodenal exclusion device (DED) at Week 2, and randomization to DJB or SG surgery at Week 8 with subsequent 4-week follow-up. At Week 12, the pigs were sacrificed and necropsy was performed. RESULTS: Endoscopic procedures were technically successful. One pig did not receive a DED due to early GJ-LAMS migration leading to premature closure of the GJA. At Week 8, all 4 pigs were doing well, and the remaining 3 GJ-LAMS and 3 DEDs were uneventfully endoscopically removed. Two one-anastomosis DJB were performed, and 2 SG were performed, closing in one case the site of the previous GJA. The surgical procedures were technically feasible and uneventful during follow-up. Necropsy assessments showed no local or peritoneal inflammation or abscess and no leakage or fistula. CONCLUSION: An endoscopic bariatric bypass can be transitioned to a one-anastomosis duodenal-jejunal bypass or sleeve gastrectomy, without complications.


Asunto(s)
Cirugía Bariátrica , Derivación Gástrica , Obesidad Mórbida , Animales , Estudios de Factibilidad , Gastrectomía/métodos , Derivación Gástrica/métodos , Obesidad Mórbida/cirugía , Proyectos Piloto , Estudios Prospectivos , Porcinos , Resultado del Tratamiento
11.
Sci Rep ; 12(1): 21, 2022 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-34996894

RESUMEN

We conducted a pilot study of a potential endoscopic alternative to bariatric surgery. We developed a Natural Orifice Transluminal Endoscopic Surgery (NOTES) gastric bypass with controlled bypass limb length using four new devices including a dedicated lumen-apposing metal stent (GJ-LAMS) and pyloric duodenal exclusion device (DED). We evaluated procedural technical success, weight change from baseline, and adverse events in growing Landrace/Large-White pigs through 38 weeks after GJ-LAMS placement. Six pigs (age 2.5 months, mean baseline weight 26.1 ± 2.7 kg) had initial GJ-LAMS placement with controlled bypass limb length, followed by DED placement at 2 weeks. Technical success was 100%. GJ-LAMS migrated in 3 of 6, and DED migrated in 3 of 5 surviving pigs after mucosal abrasion. One pig died by Day 94. At 38 weeks, necropsy showed 100-240 cm limb length except for one at 760 cm. Weight gain was significantly lower in the pigs that underwent endoscopic bypass procedures compared to expected weight for age. This first survival study of a fully endoscopic controlled bypass length gastrojejunostomy with duodenal exclusion in a growing porcine model showed high technical success but significant adverse events. Future studies will include procedural and device optimizations and comparison to a control group.


Asunto(s)
Duodeno/cirugía , Endoscopía del Sistema Digestivo/métodos , Obesidad Mórbida/cirugía , Animales , Modelos Animales de Enfermedad , Duodeno/metabolismo , Endoscopía del Sistema Digestivo/instrumentación , Estudios de Seguimiento , Derivación Gástrica/efectos adversos , Humanos , Obesidad Mórbida/metabolismo , Obesidad Mórbida/mortalidad , Proyectos Piloto , Stents , Porcinos , Resultado del Tratamiento
12.
Gastrointest Endosc ; 94(6): 1046-1055, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34186052

RESUMEN

BACKGROUND AND AIMS: Expert endoscopists previously reported ERCP outcomes for the first commercialized single-use duodenoscope. We aimed to document usability of this device by endoscopists with different levels of ERCP experience. METHODS: Fourteen "expert" (>2000 lifetime ERCPs) and 5 "less-expert" endoscopists performed consecutive ERCPs in patients without altered pancreaticobiliary anatomy. Outcomes included ERCP completion for the intended indication, rate of crossover to another endoscope, device performance ratings, and serious adverse events. RESULTS: Two hundred ERCPs including 81 (40.5%) with high complexity (American Society for Gastrointestinal Endoscopy grades 3-4) were performed. Crossover rate (11.3% vs 2.5%, P = .131), ERCP completion rate (regardless of crossovers) (96.3% vs 97.5%, P = .999), median ERCP completion time (25.0 vs 28.5 minutes, P = .130), mean cannulation attempts (2.8 vs 2.8, P = .954), and median overall satisfaction with the single-use duodenoscope (8.0 vs 8.0 [range, 1.0-10.0], P = .840) were similar for expert versus less-expert endoscopists, respectively. The same metrics were similar by procedural complexity except for shorter median completion time for grades 1 to 2 versus grades 3 to 4 (P < .001). Serious adverse events were reported in 13 patients (6.5%). CONCLUSIONS: In consecutive ERCPs including high complexity procedures, endoscopists with varying ERCP experience had good procedural success and reported high device performance ratings. (Clinical trial registration number: NCT04223830.).


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscopios , Cateterismo , Endoscopía Gastrointestinal , Humanos
13.
Gastroenterology ; 161(1): 185-195, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33741314

RESUMEN

BACKGROUND & AIMS: Benign biliary strictures (BBS) are complications of chronic pancreatitis (CP). Endotherapy using multiple plastic stents (MPS) or a fully covered self-expanding metal stent (FCSEMS) are acceptable treatment options for biliary obstructive symptoms in these patients. METHODS: Patients with symptomatic CP-associated BBS enrolled in a multicenter randomized noninferiority trial comparing 12-month treatment with MPS vs FCSEMS. Primary outcome was stricture resolution status at 24 months, defined as absence of restenting and 24-month serum alkaline phosphatase not exceeding twice the level at stenting completion. Secondary outcomes included crossover rate, numbers of endoscopic retrograde cholangiopancreatography (ERCPs) and stents, and stent- or procedure-related serious adverse events. RESULTS: Eighty-four patients were randomized to MPS and 80 to FCSEMS. Baseline technical success was 97.6% for MPS and 98.6% for FCSEMS. Eleven patients crossed over from MPS to FCSEMS, and 10 from FCSEMS to MPS. For MPS vs FCSEMS, respectively, stricture resolution status at 24 months was 77.1% (54/70) vs 75.8% (47/62) (P = .008 for noninferiority intention-to-treat analysis), mean number of ERCPs was 3.9 ± 1.3 vs 2.6 ± 1.3 (P < .001, intention-to-treat), and mean number of stents placed was 7.0 ± 4.4 vs 1.3 ± .6 (P < .001, as-treated). Serious adverse events occurred in 16 (19.0%) MPS and 19 (23.8%) FCSEMS patients (P = .568), including cholangitis/fever/jaundice (9 vs 7 patients respectively), abdominal pain (5 vs 5), cholecystitis (1 vs 3) and post-ERCP pancreatitis (0 vs 2). No stent- or procedure-related deaths occurred. CONCLUSIONS: Endotherapy of CP-associated BBS has similar efficacy and safety for 12-month treatment using MPS compared with a single FCSEMS, with FCSEMS requiring fewer ERCPs over 2 years. (ClinicalTrials.gov, Number: NCT01543256.).


Asunto(s)
Colestasis/terapia , Materiales Biocompatibles Revestidos , Drenaje/instrumentación , Pancreatitis Crónica/complicaciones , Plásticos , Stents Metálicos Autoexpandibles , Stents , Adulto , Anciano , Colestasis/diagnóstico por imagen , Colestasis/etiología , Drenaje/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pancreatitis Crónica/diagnóstico , Diseño de Prótesis , Resultado del Tratamiento
14.
Endosc Int Open ; 8(11): E1639-E1653, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33140020

RESUMEN

Background and study aims Lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off pancreatic necrosis (WON). Recent studies suggested greater adverse event (AE) rates with LAMS for WON. We conducted a systematic review and meta-analysis to compare the safety and efficacy of LAMS with double-pigtail plastic stents (DPPS) for endoscopic drainage of WON. The primary aim was to evaluate stent-related AEs. Methods In October 2019, we searched the Ovid (Embase, MEDLINE, Cochrane) and Scopus databases for studies assessing a specific LAMS or DPPS for WON drainage conducted under EUS guidance. Safety outcomes were AE rates of bleeding, stent migration, perforation, and stent occlusion. Efficacy outcomes were WON resolution and number of procedures needed to achieve resolution. A subanalysis including non-EUS-guided cases was performed. Results Thirty studies including one randomized controlled trial (total 1,524 patients) were analyzed. LAMS were associated with similar bleeding (2.5 % vs. 4.6 %, P =  0.39) and perforation risk (0.5 % vs. 1.1 %, P =  0.35) compared to DPPS. WON resolution (87.4 % vs. 87.5 %, P =  0.99), number of procedures to achieve resolution (2.09 vs. 1.88, P =  0.72), stent migration (5.9 % vs. 6.8 %, P =  0.79), and stent occlusion (3.8 % vs. 5.2 %, P =  0.78) were similar for both groups. Inclusion of non-EUS-guided cases led to significantly higher DPPS bleeding and perforation rates. Conclusions LAMS and DPPS were associated with similar rates of AEs and WON resolution when limiting analysis to EUS-guided cases. Higher bleeding rates were seen in historical studies of DPPS without EUS guidance. Additional high-quality studies of WON treatment using consistent outcome definitions are needed.

15.
Gastrointest Endosc ; 92(6): 1216-1224, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32417298

RESUMEN

BACKGROUND AND AIMS: Minimally invasive treatments of anastomotic benign biliary stricture (BBS) after orthotopic liver transplantation (OLT) include endoscopic placement of multiple plastic stents or fully covered self-expandable metal stents (FCSEMSs). No multiyear efficacy data are available on FCSEMS treatment after OLT. METHODS: We prospectively studied long-term efficacy and safety of FCSEMS treatment in adults aged ≥18 years with past OLT, cholangiographically confirmed BBS, and an indication for ERCP with stent placement. Stent removal was planned after 4 to 6 months, with subsequent follow-up until 5 years or stricture recurrence. Long-term outcomes were freedom from stricture recurrence, freedom from recurrent stent placement, and stent-related serious adverse events (SAEs). RESULTS: In 41 patients, long-term follow-up began after FCSEMS removal (n = 33) or observation of complete distal migration (CDM) (n = 8). On an intention-to-treat basis, the 5-year probability of remaining stent-free after FCSEMS removal or observation of CDM was 48.9% (95% confidence interval [CI], 33.2%-64.7%) among all patients and 60.9% (95% CI, 43.6%-78.2%) among 31 patients with over 4 months of FCSEMS indwell time. In 28 patients with stricture resolution at FCSEMS removal or observed CDM (median, 5.0 months indwell time), the 5-year probability of no stricture recurrence was 72.6% (95% CI, 55.3%-90%). Sixteen patients (39%) had at least 1 related SAE, most commonly cholangitis (n = 10). CONCLUSIONS: By 5 years after temporary FCSEMS treatment of post-OLT BBS, approximately half of all patients remained stent-free on an intention-to-treat basis. Stent-related SAEs (especially cholangitis) were common. FCSEMS placement is a viable long-term treatment option for patients with post-OLT BBS. (Clinical trial registration number: NCT01014390.).


Asunto(s)
Enfermedades de los Conductos Biliares/cirugía , Constricción Patológica/cirugía , Trasplante de Hígado , Stents Metálicos Autoexpandibles , Adulto , Anciano , Enfermedades de los Conductos Biliares/etiología , Colangiopancreatografia Retrógrada Endoscópica , Constricción Patológica/etiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Implantación de Prótesis , Resultado del Tratamiento
16.
Endoscopy ; 52(7): 574-582, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32289852

RESUMEN

BACKGROUND: Peroral cholangioscopy (POCS) of indeterminate biliary strictures aims to achieve a diagnosis through visual examination and/or by obtaining targeted biopsies under direct visualization. In this large, prospective, multinational, real-life experience of POCS-guided evaluation of indeterminate biliary strictures, we evaluated the performance of POCS in this difficult-to-manage patient population. METHODS: This prospective registry enrolled patients, with indeterminate biliary strictures across 20 centers in Asia, the Middle East, and Africa. The primary end points were the ability to visualize the lesion, obtain histological sampling when intended, and an assessment of the diagnostic accuracy of POCS for malignant strictures. Patients were followed for 6 months after POCS or until a definitive malignant diagnosis was made, whichever occurred first. RESULTS: 289 patients underwent 290 POCS procedures with intent to biopsy in 182 cases. The stricture/filling defect was successfully visualized in 286/290 (98.6 %), providing a visual diagnostic impression in 253/290 (87.2 %) and obtaining adequate biopsies in 169/182 (92.9 %). Procedure-related adverse events occurred in 5/289 patients (1.7 %). POCS influenced patient management principally by elucidating filling defects or the causes of bile duct stricture or dilation. The visual impression of malignancy showed 86.7 % sensitivity, 71.2 % specificity, 65.8 % positive and 89.4 % negative predictive value, and 77.2 % overall accuracy compared with final diagnosis. Histological POCS-guided samples showed 75.3 % sensitivity, 100 % specificity, 100 % positive and 77.1 % negative predictive value, and 86.5 % overall accuracy. CONCLUSION: In this large, real-life, prospective series, POCS was demonstrated to be an effective and safe intervention guiding the management of patients with indeterminate biliary strictures.


Asunto(s)
Colestasis , Endoscopía del Sistema Digestivo , Asia , Colestasis/etiología , Constricción Patológica/etiología , Humanos , Sistema de Registros
17.
Gastrointest Endosc ; 91(2): 361-369.e3, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31494135

RESUMEN

BACKGROUND AND AIMS: Temporary single, fully covered self-expanding metal stent (FCSEMS) placement for benign biliary strictures (BBSs) associated with chronic pancreatitis (CP) may require fewer interventions than endotherapy with multiple plastic stents and may carry less morbidity than biliary diversion surgery. This study aimed to assess long-term outcomes in CP-associated BBSs after FCSEMS placement and removal. METHODS: In this open-label, multinational, prospective study, subjects with CP and a BBS treated with FCSEMS placement with scheduled removal at 10 to 12 months were followed for 5 years after FCSEMS indwell. Kaplan-Meier analyses assessed BBS resolution and cumulative probability of freedom from recurrent stent placement to 5 years after FCSEMS indwell. RESULTS: One hundred eighteen patients were eligible for FCSEMS removal. At a median of 58 months (interquartile range, 44-64) post-FCSEMS indwell, the probability of remaining stent-free was 61.6% (95% confidence interval [CI], 52.5%-70.7%). In 94 patients whose BBSs resolved at the end of FCSEMS indwell, the probability of remaining stent-free 5 years later was 77.4% (95% CI, 68.4%-86.4%). Serious stent-related adverse events occurred in 27 of 118 patients (22.9%); all resolved with medical therapy or repeated endoscopy. Multivariate analysis identified severe CP (hazard ratio, 2.4; 95% CI, 1.0-5.6; P = .046) and longer stricture length (hazard ratio, 1.2; 95% CI, 1.0-1.4; P = .022) as predictors of stricture recurrence. CONCLUSION: In patients with symptomatic BBSs secondary to CP, 5 years after placement of a single FCSEMS intended for 10 to 12 months indwell, more than 60% remained asymptomatic and stent-free with an acceptable safety profile. Temporary placement of a single FCSEMS may be considered as first-line treatment for patients with CP and BBSs. (Clinical trial registration number: NCT01014390.).


Asunto(s)
Colestasis/terapia , Pancreatitis Crónica/complicaciones , Stents Metálicos Autoexpandibles , Adulto , Enfermedades de los Conductos Biliares/etiología , Enfermedades de los Conductos Biliares/terapia , Colangiopancreatografia Retrógrada Endoscópica , Colangitis/epidemiología , Colestasis/etiología , Constricción Patológica/etiología , Constricción Patológica/terapia , Remoción de Dispositivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Recurrencia , Resultado del Tratamiento
18.
Gastrointest Endosc ; 91(2): 396-403, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31679738

RESUMEN

BACKGROUND AND AIMS: Multidrug-resistant infectious outbreaks associated with duodenoscope reuse have been documented internationally. A single-use endoscope could eliminate exogenous patient-to-patient infection associated with ERCP. METHODS: We conducted a comparative bench simulation study of a new single-use and 3 models of reusable duodenoscopes on a synthetic anatomic bench model. Four ERCP tasks were performed: guidewire locking (single-use and 1 reusable duodenoscope only), plastic stent placement and removal, metal stent placement and removal, and basket sweeping. The study schedule included block randomization by 4 duodenoscopes, 4 tasks, and 2 anatomic model ERCP stations. Ability to complete tasks, task completion times, and subjective ratings of overall performance, navigation/pushability, tip control, and image quality on a scale of 1 (worst) to 10 (best) were compared among duodenoscopes. RESULTS: All 4 ERCP tasks (total 14 subtasks) were completed by 6 expert endoscopists using all 4 duodenoscopes, with similar task completion times (median, 1.5-8.0 minutes per task) and overall performance ratings by task (median, 8.0-10.0). Navigation/pushability ratings were lower for the single-use duodenoscope than for the 3 reusable duodenoscopes (median, 8.0, 10.0, 9.0, and 9.0, respectively; P < .01). Tip control ratings were similar among all the duodenoscopes (median, 9.0-10.0; P = .77). Image quality ratings were lower for 1 reusable duodenoscope compared with the single-use and other 2 reusable duodenoscopes (median, 8.0, 9.0, 9.0, and 9.0, respectively; P < .01). CONCLUSIONS: A new single-use duodenoscope was used to simulate 4 ERCP tasks in an anatomic model, with performance ratings and completion times comparable with 3 models of reusable duodenoscopes.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/instrumentación , Equipos Desechables/normas , Duodenoscopios/normas , Equipo Reutilizado , Modelos Anatómicos , Tempo Operativo , Infección Hospitalaria/prevención & control , Humanos , Distribución Aleatoria
19.
Clin Gastroenterol Hepatol ; 18(9): 2108-2117.e3, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31706060

RESUMEN

BACKGROUND & AIMS: Disposable, single-use duodenoscopes might reduce outbreaks of infections associated with endoscope reuse. We tested the feasibility, preliminary safety, and performance of a new single-use duodenoscope in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP). METHODS: We conducted a case-series study of the outcomes of ERCP with a single-use duodenoscope from April through May 2019 at 6 academic medical centers. We screened consecutive patients (18 years and older) without alterations in pancreaticobiliary anatomy and enrolled 73 patients into the study. Seven expert endoscopists performed roll-in maneuvers (duodenoscope navigation and visualization of duodenal papilla only) in 13 patients and then ERCPs in the 60 other patients. Outcomes analyzed included completion of ERCP for the intended clinical indication, crossover from a single-use duodenoscope to a reusable duodenoscope, endoscopist performance ratings of the device, and serious adverse events (assessed at 72 hours and 7 days). RESULTS: Thirteen (100%) roll-in maneuver cases were completed using the single-use duodenoscope. ERCPs were of American Society for Gastrointestinal Endoscopy procedural complexity grade 1 (least complex; 7 patients [11.7%]), grade 2 (26 patients [43.3%]), grade 3 (26 patients [43.3%]), and grade 4 (most complex; 1 patient [1.7%]). Fifty-eight ERCPs (96.7%) were completed using the single-use duodenoscope only and 2 ERCPs (3.3%) were completed using the single-use duodenoscope followed by crossover to a reusable duodenoscope. Median overall satisfaction was 9 out of 10. Three patients developed post-ERCP pancreatitis, 1 patient had post-sphincterotomy bleeding, and 1 patient had worsening of a preexisting infection and required rehospitalization. CONCLUSIONS: In a case-series study, we found that expert endoscopists can complete ERCPs of a wide range of complexity using a single-use duodenoscope for nearly all cases. This alternative might decrease ERCP-related risk of infection. Clinicaltrials.gov no: NCT03701958.


Asunto(s)
Duodenoscopios , Pancreatitis , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Brotes de Enfermedades , Endoscopía Gastrointestinal , Humanos
20.
BMC Gastroenterol ; 19(1): 214, 2019 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-31830897

RESUMEN

BACKGROUND: Endoscopic treatment of post-cholecystectomy biliary strictures (PCBS) with multiple plastic biliary stents placed sequentially is a minimally invasive alternative to surgery but requires multiple interventions. Temporary placement of a single fully-covered self-expanding metal stent (FCSEMS) may offer safe and effective treatment with fewer re-interventions. Long-term effectiveness of treatment with FCSEMS to obtain PCBS resolution has not yet been studied. METHODS: In this prospective multi-national study in patients with symptomatic benign biliary strictures (N = 187) due to various etiologies received a FCSEMS with scheduled removal at 6-12 months and were followed for 5 years. We report here long-term outcomes of the subgroup of patients with PCBS (N = 18). Kaplan Meier analyses assessed long-term freedom from re-stenting. Adverse events were documented. RESULTS: Endoscopic removal of the FCSEMS was achieved in 83.3% (15/18) of patients after median indwell of 10.9 (range 0.9-13.8) months. In the remaining 3 patients (16.7%), the FCSEMS spontaneously migrated and passed without complications. At the end of FCSEMS indwell, 72% (13/18) of patients had stricture resolution. At 5 years after FCSEMS removal, 84.6% (95% CI 65.0-100.0%) of patients who had stricture resolution at FCSEMS removal remained stent-free. In addition, at 75 months after FCSEMS placement, the probability of remaining stent-free was 61.1% (95% CI 38.6-83.6%) for all patients. Stent or removal related serious adverse events occurred in 38.9% (7/18) all resolved without sequalae. CONCLUSIONS: In patients with symptomatic PCBS, temporary placement of a single FCSEMS intended for 10-12 months indwell is associated with long-term stricture resolution up to 5 years. Temporary placement of a single FCSEMS may be considered for patients with PCBS not involving the main hepatic confluence. TRIAL REGISTRATION NUMBERS: NCT01014390; CTRI/2012/12/003166; Registered 17 November 2009.


Asunto(s)
Colecistectomía/efectos adversos , Colestasis/terapia , Complicaciones Posoperatorias/terapia , Stents Metálicos Autoexpandibles , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Constricción Patológica/terapia , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Stents Metálicos Autoexpandibles/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...