1.
J Biomech Eng ; 146(10)2024 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-38668718

RESUMEN

Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50-90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80-90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50-70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60-70% for maximizing osseointegration with current structure and loading.


Asunto(s)
Análisis de Elementos Finitos , Ensayo de Materiales , Oseointegración , Porosidad , Prótesis e Implantes , Fenómenos Mecánicos , Animales , Metales/química , Estrés Mecánico
2.
Eur Spine J ; 33(5): 2097-2115, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38372793

RESUMEN

PURPOSE: To evaluate the biological and biomechanical effects of fenestration/microdiscectomy in an in vivo rabbit model, and in doing so, create a preclinical animal model of IVDD. METHODS: Lateral lumbar IVD fenestration was performed in vivo as single- (L3/4; n = 12) and multi-level (L2/3, L3/4, L4/5; n = 12) fenestration in skeletally mature 6-month-old New Zealand White rabbits. Radiographic, micro-CT, micro-MRI, non-destructive robotic range of motion, and histological evaluations were performed 6- and 12-weeks postoperatively. Independent t tests, one-way and two-way ANOVA and Kruskal-Wallis tests were used for parametric and nonparametric data, respectively. Statistical significance was set at P < 0.05. RESULTS: All rabbits recovered uneventfully from surgery and ambulated normally. Radiographs and micro-CT demonstrated marked reactive proliferative osseous changes and endplate sclerosis at fenestrated IVDs. Range of motion at the fenestrated disc space was significantly reduced compared to intact controls at 6- and 12-weeks postoperatively (P < 0.05). Mean disc height index percentage for fenestrated IVDs was significantly lower than adjacent, non-operated IVDs for both single and multi-level groups, at 6 and 12 weeks (P < 0.001). Pfirrmann MRI IVDD and histological grading scores were significantly higher for fenestrated IVDs compared to non-operated adjacent and age-matched control IVDs for single and multi-level groups at 6 and 12 weeks (P < 0.001). CONCLUSIONS: Fenestration, akin to microdiscectomy, demonstrated significant biological, and biomechanical effects in this in vivo rabbit model and warrants consideration by veterinary and human spine surgeons. This described model may be suitable for preclinical in vivo evaluation of therapeutic strategies for IVDD in veterinary and human patients.


Asunto(s)
Modelos Animales de Enfermedad , Disco Intervertebral , Vértebras Lumbares , Animales , Conejos , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Disco Intervertebral/cirugía , Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Discectomía/métodos , Rango del Movimiento Articular/fisiología , Microtomografía por Rayos X , Imagen por Resonancia Magnética
3.
J Biomed Mater Res B Appl Biomater ; 112(1): e35356, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38247241

RESUMEN

Sterilization of structural bone allografts is a critical process prior to their clinical use in large cortical bone defects. Gamma irradiation protocols are known to affect tissue integrity in a dose dependent manner. Alternative sterilization treatments, such as supercritical carbon dioxide (SCCO2 ), are gaining popularity due to advantages such as minimal exposure to denaturants, the lack of toxic residues, superior tissue penetration, and minor impacts on mechanical properties including strength and stiffness. The impact of SCCO2 on the fracture toughness of bone tissue, however, remains unknown. Here, we evaluate crack initiation and growth toughness after 2, 6, and 24 h SCCO2 -treatment using Novakill™ and ethanol as additives on ~11 samples per group obtained from a pair of femur diaphyses of a canine. All mechanical testing was performed at ambient air after 24 h soaking in Hanks' balanced salt solution (HBSS). Results show no statistically significant difference in the failure characteristics of the Novakill™-treated groups whereas crack growth toughness after 6 and 24 h of treatment with ethanol significantly increases by 37% (p = .010) and 34% (p = .038), respectively, compared to an untreated control group. In contrast, standard 25 kGy gamma irradiation causes significantly reduced crack growth resistance by 40% (p = .007) compared to untreated bone. FTIR vibrational spectroscopy, conducted after testing, reveals a consistent trend of statistically significant differences (p < .001) with fracture toughness. These trends align with variations in the ratios of enzymatic mature to immature crosslinks in the collagen structure, suggesting a potential association with fracture toughness. Additional Raman spectroscopy after testing shows a similar trend with statistically significant differences (p < .005), which further supports that collagen structural changes occur in the SCF-treated groups with ethanol after 6 and 24 h. Our work reveals the benefits of SCCO2 sterilization compared to gamma irradiation.


Asunto(s)
Dióxido de Carbono , Fracturas Óseas , Animales , Perros , Dióxido de Carbono/farmacología , Etanol/farmacología , Huesos , Hueso Cortical , Colágeno/farmacología
4.
Am J Vet Res ; 85(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38029513

RESUMEN

OBJECTIVE: Compare 3 methods of nucleus pulposus (NP) volume measurement using the rabbit lumbar spines as a preclinical model to determine the effectiveness of prophylactic intervertebral disk fenestration in dogs. ANIMALS: Twelve 9-month-old, skeletally mature female entire New Zealand White rabbits weighing between 3.5 to 4.5 kg. METHODS: NP volume measurements of dissected rabbit lumber spines between L1 and L6 were made and compared using gross measurements, reconstructed MRI images, and water volumetry based on Archimedes' principle. Water volumetry was used as the true gold standard volume measurement in this study. RESULTS: The true volume (mean ± SD) of the nucleus pulposus NP as measured by water volumetry increased caudally from L1/L2 (16.26 ± 3.32 mm3) to L5/L6 (22.73 ± 6.09 mm3). Volume estimates made by MRI were significantly higher than those made using water volumetry at all sites (L1/L2 [P = .044], L2/L3 [P = .012], L3/L4 [P = .015], L4/L5 [P < .001], and L5/L6 [P < .001]). Gross measurements also significantly overestimated volume when compared to water volumetry at all sites; L1/L2 (P = .021), L2/L3 (P = .025), L3/L4 (P = .001), L4/L5 (P < .001), and L5/L6 (P < .001). MRI and gross volume estimates were significantly different at L4/L5 (P = .035) and L5/L6 (P = .030). CLINICAL RELEVANCE: The findings of this preclinical model might be relevant to veterinary surgeons who perform prophylactic fenestration for which there is no reliable method to determine the amount of NP to be removed. Preclinical ex vivo and in vivo fenestration studies with pre- and postoperative NP volume assessment are required.


Asunto(s)
Enfermedades de los Perros , Degeneración del Disco Intervertebral , Disco Intervertebral , Núcleo Pulposo , Conejos , Perros , Femenino , Animales , Núcleo Pulposo/diagnóstico por imagen , Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/cirugía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/prevención & control , Degeneración del Disco Intervertebral/veterinaria , Agua
6.
JOR Spine ; 6(1): e1234, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36994459

RESUMEN

Intervertebral disc degeneration (IVDD), a widely recognized cause of lower back pain, is the leading cause of disability worldwide. A myriad of preclinical in vivo animal models of IVDD have been described in the literature. There is a need for critical evaluation of these models to better inform researchers and clinicians to optimize study design and ultimately, enhance experimental outcomes. The purpose of this study was to conduct an extensive systematic literature review to report the variability of animal species, IVDD induction method, and experimental timepoints and endpoints used in in vivo IVDD preclinical research. A systematic literature review of peer-reviewed manuscripts featured on PubMed and EMBASE databases was conducted in accordance with PRISMA guidelines. Studies were included if they reported an in vivo animal model of IVDD and included details of the species used, how disc degeneration was induced, and the experimental endpoints used for analysis. Two-hundred and fifty-nine (259) studies were reviewed. The most common species, IVDD induction method and experimental endpoint used was rodents(140/259, 54.05%), surgery (168/259, 64.86%) and histology (217/259, 83.78%), respectively. Experimental timepoint varied greatly between studies, ranging from 1 week (dog and rodent models), to >104 weeks in dog, horse, monkey, rabbit, and sheep models. The two most common timepoints used across all species were 4 weeks (49 manuscripts) and 12 weeks (44 manuscripts). A comprehensive discussion of the species, methods of IVDD induction and experimental endpoints is presented. There was great variability across all categories: animal species, method of IVDD induction, timepoints and experimental endpoints. While no animal model can replicate the human scenario, the most appropriate model should be selected in line with the study objectives to optimize experimental design, outcomes and improve comparisons between studies.

7.
J Vis Exp ; (190)2022 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-36533818

RESUMEN

Bone models serve many purposes, including improving anatomical understanding, preoperative surgical planning, and intraoperative referencing. Several techniques for the maceration of soft tissues have been described, mainly for forensic analysis. For clinical research and medical use, these methods have been superseded by three-dimensional (3D) printed models, which require substantial equipment and expertise, and are costly. Here, cadaveric sheep vertebral bone was cleaned by vacuum sealing the specimen with commercial dishwashing detergent, immersing in a hot water bath, and subsequently manually removing the soft tissue. This eliminated the disadvantages of the previously existing maceration methods, such as the existence of foul odors, usage of hazardous chemicals, substantial equipment, and high costs. The described technique produced clean, dry samples while maintaining anatomical detail and structure to accurately model the osseous structures that can be useful for preoperative planning and intraoperative referencing. The method is simple, low-cost, and effective for bone model preparation for education and surgical planning in veterinary and human medicine.


Asunto(s)
Inmersión , Modelos Anatómicos , Humanos , Animales , Ovinos , Huesos , Cadáver , Agua , Impresión Tridimensional
8.
Materials (Basel) ; 15(14)2022 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-35888273

RESUMEN

Corrosion of medical implants is a possible failure mode via induced local inflammatory effects, systemic deposition and corrosion related mechanical failure. Cyclic potentiodynamic polarisation (CPP) testing was utilized to evaluate the effect of increased porosity (60% and 80%) and decreased wall thickness in gyroid lattice structures on the electrochemical behaviour of LPBF Ti6Al4V structures. The use of CPP allowed for the landmarks of breakdown potential, resting potential and vertex potential to be analysed, as well as facilitating the construction of Tafel plots and qualitative Goldberg analysis. The results indicated that 60% gyroid samples were most susceptible to the onset of pitting corrosion when compared to 80% gyroid and solid samples. This was shown through decreased breakdown and vertex potentials and were found to correlate to increased lattice surface area to void volume ratio. Tafel plots indicated that despite the earlier onset of pitting corrosion, both gyroid test groups displayed lower rates of corrosion per year, indicating a lower severity of corrosion. This study highlighted inherent tradeoffs between lattice optimisation and corrosion behaviour with a potential parabolic link between void volume, surface area and corrosion being identified. This potential link is supported by 60% gyroid samples having the lowest breakdown potentials, but investigation into other porosity ranges is suggested to support the hypothesis. All 3D printed materials studied here showed breakdown potentials higher than ASTM F2129's suggestion of 800 mV for evaluation within the physiological environment, indicating that under static conditions pitting and crevice corrosion should not initiate within the body.

9.
J Spine Surg ; 8(1): 117-131, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35441100

RESUMEN

Background: 'SMART' implants refer to modified orthopedic implants that combine the biomechanical safety and efficacy of traditional devices with the intelligence of data-logging sensors. This review aims to systematically assess the available literature on SMART spinal implants and present these findings in a clinically relevant manner. Methods: A search of PubMed, Scopus, and Google Scholar databases was conducted by two separate reviewers. Information including sensor type, intended application, and sample size, was extracted from included studies. Risk of bias assessment was conducted using the Office of Health Assessment and Translation (OHAT) risk of bias tool. Results: Eighteen studies were included for analysis. Eight studies involved SMART rods and ten studies used SMART vertebral body replacements (VBR). No more than 20 patients are reported to have received a SMART spinal implant. Including non-primary evidence, seven unique designs for SMART spinal implants were found. The majority of these used strain gauges with recent designs including thermometers and accelerometers. Discussion: At present, SMART spinal implants have primarily focused on utilising strain gauges to report loading on the implant itself. This is a logical first step as it allows quantification of real-world requirements of an implant, detection of catastrophic failure, while also allowing researchers and clinicians to estimate changes in load sharing between newly forming bone and the implant itself, providing real-time information on the progression of healing and fusion. Future work includes documenting the correlation between data provided by these SMART implants and clinical findings, including complications such as pedicle screw loosening and interbody cage subsidence.

10.
J Spine Surg ; 8(1): 93-102, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35441107

RESUMEN

Background: Cervical spine range of motion (ROM) assessment has long been carried out via use of the universal goniometer (UG) as an objective tool in the evaluation of patient rehabilitation pre- and post-operatively. The advent of novel ROM assessment technology, such as HALO digital goniometer (DG), presents an avenue for research and potential application within clinical and surgical settings. The objective of this study was to examine the reliability and validity of the HALO DG in the assessment of the active ROM of the cervical spine. Methods: One hundred healthy subjects were recruited for the study and were split into two groups to be assessed by either physiotherapists or medical students. The methodology for cervical spine ROM assessment was carried out per the American Association of Orthopaedic Surgeons (AAOS) guidelines. The reliability analysis was completed using IBM SPSS Statistics 25, calculating the intraclass correlation coefficients (ICC) to determine both the intra- and inter-rater reliability of the device. Results: Inter-rater reliability within the physiotherapist cohort with the DG (ICCr =0.477, 0.718, 0.551) was higher compared to the UG (ICCr =0.380, 0.510, 0.255) for active cervical flexion, lateral flexion, and rotation, respectively. The UG (ICCr =0.819) showed better reliability versus the DG (ICCr =0.780) when assessing cervical extension. Similarly, in the medical student cohort, the DG outperformed the UG in all movement except cervical lateral flexion. When assessing for intra-rater reliability, the DG (ICCm =0.507, 0.773, 0.728, 0.691) performed better than the UG (ICCm =0.487, 0.529, 0.532, 0.585) in cervical flexion, extension, lateral flexion, and rotation, respectively. Conclusions: The present validation study identified the DG as a reliable substitute for the UG.

11.
J Mech Behav Biomed Mater ; 129: 105155, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35313188

RESUMEN

Water is a crucial component of bone, affecting the interplay of collagen and minerals and contributing to bone's high strength and ductility. Dehydration has been shown to significantly effect osseous mechanical properties; however, studies comparing the effects of various dehydrating environments on fracture toughness of bone are scarce. Accordingly, the crack resistance curve (R-curve) behavior of human and sheep cortical bone was characterized in a bio-bath, in ambient pressure air, and in scanning electron microscopes (SEMs) under three different environmental conditions (water vapor pressure, air pressure, and high-vacuum). The aim of this work was to better understand the impact of test environment on both intrinsic and extrinsic toughening and hence crack initiation toughness, K0 and crack growth resistance, dK/dΔa. Results show significantly lower K0 values for samples that were tested inside SEMs combined with pronounced extrinsic toughening through microcracking and crack path deflections out of the mode I plane. Importantly, all three SEM test environments gave similar results, and thus it does not matter which type of SEM is used. Ex situ testing of hydrated samples revealed similar K0 for both environments but elevated crack growth resistance for testing in ambient air relative to the bio-bath. Our data reveals the experimental difficulties to directly observe microscale crack propagation in cortical bone that resembles the in vivo situation. Ex situ testing immersed in Hanks' Balanced Salt Solution (HBSS) with subsequent crack path analysis, while tedious, is thought to presents the most realistic picture of the in vivo structure-fracture property relations in biological tissue.


Asunto(s)
Huesos , Fracturas Óseas , Animales , Colágeno , Hueso Cortical , Ovinos , Estrés Mecánico , Resistencia a la Tracción
12.
Spine J ; 22(6): 1028-1037, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35017054

RESUMEN

BACKGROUND CONTEXT: Cage subsidence remains a serious complication after spinal fusion surgery. Novel porous designs in the cage body or endplate offer attractive options to improve subsidence and osseointegration performance. PURPOSE: To elucidate the relative contribution of a porous design in each of the two major domains (body and endplates) to cage stiffness and subsidence performance, using standardized mechanical testing methods, and to analyze the fusion progression via an established ovine interbody fusion model to support the mechanical testing findings. STUDY DESIGN/SETTING: A comparative preclinical study using standardized mechanical testing and established animal model. METHODS: To isolate the subsidence performance contributed by each porous cage design feature, namely the stress-optimized body lattice (vs. a solid body) and microporous endplates (vs. smooth endplates), four groups of cages (two-by-two combination of these two features) were tested in: (1) static axial compression of the cage (per ASTM F2077) and (2) static subsidence (per ASTM F2267). To evaluate the progression of fusion, titanium cages were created with a microporous endplate and internal lattice architecture analogous to commercial implants used in subsidence testing and implanted in an endplate-sparing, ovine intervertebral body fusion model. RESULTS: The cage stiffness was reduced by 16.7% by the porous body lattice, and by 16.6% by the microporous endplates. The porous titanium cage with both porous features showed the lowest stiffness with a value of 40.4±0.3 kN/mm (Mean±SEM) and a block stiffness of 1976.8±27.4 N/mm for subsidence. The body lattice showed no significant impact on the block stiffness (1.4% reduction), while the microporous endplates decreased the block stiffness significantly by 24.9% (p<.0001). All segments implanted with porous titanium cages were deemed rigidly fused by manual palpation, except one at 12 weeks, consistent with robotic ROM testing and radiographic and histologic observations. A reduction in ROM was noted from 12 to 26 weeks (4.1±1.6° to 2.2±1.4° in lateral bending, p<.05; 2.1±0.6° to 1.5±0.3° in axial rotation, p<.05); and 3.3±1.6° to 1.9±1.2° in flexion extension, p=.07). Bone in the available void improved with time in the central aperture (54±35% to 83±13%, p<.05) and porous cage structure (19±26% to 37±21%, p=.15). CONCLUSIONS: Body lattice and microporous endplates features can effectively reduce the cage stiffness, therefore reducing the risk of stress shielding and promoting early fusion. While body lattice showed no impact on block stiffness and the microporous endplates reduced the block stiffness, a titanium cage with microporous endplates and internal lattice supported bone ingrowth and segmental mechanical stability as early as 12 weeks in ovine interbody fusion. CLINICAL SIGNIFICANCE: Porous titanium cage architecture can offer an attractive solution to increase the available space for bone ingrowth and bridging to support successful spinal fusion while mitigating risks of increased subsidence.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Animales , Fenómenos Biomecánicos , Humanos , Vértebras Lumbares/cirugía , Porosidad , Impresión Tridimensional , Ovinos , Titanio
13.
Hip Int ; 32(2): 231-236, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33081513

RESUMEN

BACKGROUND: The aim of this study was to investigate total hip arthroplasty (THA) Morse taper pull-off strengths after impaction prior to cyclical loading compared to cyclical loading alone. The practical relevance of the experiment is to provide a perspective on what may be clinically satisfactory taper assembly given the spectrum of head tapping patterns used by surgeons, as well as compare traditional impaction performed in standard THA with alternate methods of taper engagement such as 'in situ assembly' used in micro-invasive techniques. METHODS: 36 taper constructs utilising a combination of cobalt-chrome alloy and ceramic-titanium alloy junctions were investigated in vitro in wet and dry conditions with cyclical loading of the constructs. Taper disengagement strengths with and without impaction were compared. Secondary investigation of the surface roughness of the heads and tapers was also assessed. RESULTS: An impaction to a wet taper resulted in a greater pull off force compared to a dry taper with a CoCr head and taper combination. Impacting the head and dryness of the taper did not affect pull off forces of a ceramic femoral head on titanium taper. Pulling a head off a taper significantly alters the head surface roughness. CONCLUSION: Impaction of a taper does not provide any benefit over cyclical loading of a taper assembly alone for pull-off strength.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Aleaciones de Cromo , Corrosión , Humanos , Diseño de Prótesis , Falla de Prótesis , Soporte de Peso
14.
Biomaterials ; 279: 121206, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34715639

RESUMEN

Optimization of porous titanium alloy scaffolds designed for orthopedic implants requires balancing mechanical properties and osseointegrative performance. The tradeoff between scaffold porosity and the stiffness/strength must be optimized towards the goal to improve long term load sharing while simultaneously promoting osseointegration. Osseointegration into porous titanium implants covering a wide range of porosity (0%-90%) and manufactured by laser powder bed fusion (LPBF) was evaluated with an established ovine cortical and cancellous defect model. Direct apposition and remodeling of woven bone was observed at the implant surface, as well as bone formation within the interstices of the pores. A linear relationship was observed between the porosity and benchtop mechanical properties of the scaffolds, while a non-linear relationship was observed between porosity and the ex vivo cortical bone-implant interfacial shear strength. Our study supports the hypothesis of porosity dependent performance tradeoffs, and establishes generalized relationships between porosity and performance for design of topological optimized implants for osseointegration. These results are widely applicable for orthopedic implant design for arthroplasty components, arthrodesis devices such as spinal interbody fusion implants, and patient matched implants for treatment of large bone defects.


Asunto(s)
Oseointegración , Prótesis e Implantes , Aleaciones , Animales , Humanos , Porosidad , Ovinos , Titanio
15.
J Mech Behav Biomed Mater ; 123: 104775, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34419888

RESUMEN

Long-term survival of orthopedic implants requires a strong and compliant interface between the implant and surrounding bone. This paper further explores the in-vivo response to a novel, macro-scale osseointegration surface morphology. In this study, we examine the effects of material composition on osseointegration in relation to the controlled surface geometry. The pillared surface is constructed of discontinuous surface geometry which creates an open space for unencumbered bone migration. In creating an open, macro-scale morphology we have demonstrated a bone migration and integration that is less dependent on the underlying implant material and is substantially driven thru surface geometry. In this in-vivo study an established ovine model was used to examine the effects of implant material composition on bone ingrowth and mechanical performance. Cortical and cancellous sites in the tibia and distal femur were examined at 6 and 12 weeks with µCT, histology, histomorphometry, and mechanical performance. Implant materials tested included PEEK (Evonik, VISTAKEEP®), PEEK HA (Invibio, PEEK-OPTIMA HA Enhanced), Titanium coated PEEK, Titanium (Ti-6Al-4V, Grade 5), and Ultra-High Molecular Weight Polyethylene (UHMWPE). Extensive bone ingrowth was noted in all implant materials at 12 weeks with maturation of the bone within the pillar structure from 6 weeks to 12 weeks. Histology demonstrated little fibrous deposition at the implant interface with no adverse cellular reactions. Histomorphometric review of cortical sites revealed greater than 60% bone ingrowth at 6 weeks increasing to nearly 80% by the 12 week timepoint. Cancellous sites yielded a mean of 30% ingrowth at 6 weeks increasing to 35% by 12 weeks. Pushout testing of cortical site samples demonstrated increase in pushout force between the 6 and 12 week timepoints. Increases were significant in all but the UHMWPE samples. Stiffness likewise increased in all samples between the two times. These results demonstrated the effectiveness of the pillar morphology with full integrating from the surrounding bony tissue regardless of the material.


Asunto(s)
Oseointegración , Prótesis e Implantes , Animales , Fémur , Ovinos , Propiedades de Superficie , Tibia , Titanio
16.
J Mech Behav Biomed Mater ; 119: 104462, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33839536

RESUMEN

Primary stability and secondary fixation of orthopedic implants to bony tissues are important for healing and long-term functionality. Load sharing and stress transfer are key requirements of an effective implant/tissue interface. This paper presents a novel, macro-scale osseointegration surface morphology which addresses the implant/tissue interface from both the biologic as well as biomechanical perspective. The surface morphology is a controlled, engineered, open topography manifested as discrete pillars projecting from the implant enabling continuous bone ingrowth. The pillared surface is distinct from other porous surfaces and can be differentiated by the localization of the implant material into discrete pillars enabling a continuous mass of bone to freely and easily interdigitate into the pillared structure. Traditional porous structures distribute the implant material throughout the surface forcing the bone to grow in a discontinuous manner. Creating an open and continuous space or "open porosity" in and around the pillar structure allows the bone to easily interdigitate with the implant surface without encumberment from a continuous porous structure. An in-vivo study, using an established ovine model, was undertaken examining the effects of pillar morphology on bone ingrowth and mechanical performance. Cortical and cancellous sites were evaluated utilizing histology, histomophometry, and mechanical pushout, at 4 and 12 weeks. Robust bone ingrowth occurred for all morphologies as was noted in review of the study results. An increase in volume and maturity of bone was noted between the intermediated and final time points. Histomophometry demonstrated over 40% and 80% new bone occupied the available "ingrowth" area at 12 weeks for cancellous and cortical sites (respectively). Histologic review showed little fibrous tissue ingrowth at the interface with no adverse cellular reactions. Testing of cortical samples demonstrated a significant increase in pushout load between the 4 and 12 week timepoints and a 4-8 fold increase in pushout load as compared to the grit blast control. These results demonstrated the effectiveness of the novel interface for orthopedic applications in an in-vivo ovine model.


Asunto(s)
Oseointegración , Titanio , Animales , Porosidad , Prótesis e Implantes , Ovinos
17.
World Neurosurg ; 148: e1-e9, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33189919

RESUMEN

OBJECTIVE: Lower back pain associated with degenerative disc disease (DDD) is a leading cause of disability worldwide. Anterior lumbar interbody fusion (ALIF) has been shown to be effective for treating refractory DDD, but it remains unclear which patients may benefit most from the procedure. This study aims to develop a predictive model for clinical success in L5/S1 ALIF for DDD. METHODS: A retrospective cohort study of 68 patients with refractory DDD who underwent L5/S1 ALIF was performed. Clinical success was defined as an improvement in Oswestry Disability Index (ODI) of 20 points postoperatively. Exploratory analyses were performed on 16 preoperative clinical and radiographic parameters, followed by a multivariate logistic regression. Evaluation of the predictive model was performed. RESULTS: After exploratory analyses, 4 parameters were suitable for inclusion in the multivariate model. Workers' compensation status (odds ratio [OR], 0.02; 95% confidence interval [CI], 0.001-0.262; P = 0.004) and preoperative ODI (OR, 1.13; 95% CI, 1.05-1.23; P = 0.002) were statistically significant parameters. Furthermore, posterior disc height and disc depth contributed significantly to the model variance (OR, 0.69, 95% CI, 0.44-1.09 and OR, 0.97, 95% CI, 0.81-1.15, respectively). The model had a sensitivity of 81.5%, specificity of 83.3%, C-statistic of 0.921, and a calibration plot similar to the 45° reference line. CONCLUSIONS: This analysis confirms workers' compensation and low preoperative ODI as risk factors for successful L5/S1 ALIF performed for DDD. It also identifies novel prognostic factors, namely posterior disc height and disc depth. This model can aid in patient counseling and selection in the management of L5/S1 DDD.


Asunto(s)
Personas con Discapacidad , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Sacro/cirugía , Fusión Vertebral/métodos , Adulto , Anciano , Estudios de Cohortes , Femenino , Humanos , Degeneración del Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sacro/diagnóstico por imagen , Fusión Vertebral/tendencias , Resultado del Tratamiento
18.
World Neurosurg ; 146: e336-e340, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33228956

RESUMEN

BACKGROUND: Cage subsidence is a known complication of spinal fusion. Various aspects of cage design have been investigated for their influence on cage subsidence, whereas the potential contribution of graft material to load sharing is often overlooked. We aimed to determine whether graft in the aperture affects endplate pressure distribution. METHODS: The pressure distributions of a polyetheretherketone interbody cage with 3 different aperture graft conditions were evaluated: empty, demineralized bone matrix, and supercritical CO2-treated allograft bone crunch (SCCO2). RESULTS: Graft materials contributed as much as half the load transmission for SCCO2, whereas demineralized bone matrix contributed one third. Endplate areas in contact with the cage demonstrated decreased areas within the highest-pressure spectrum with SCCO2 graft materials compared with empty cages. CONCLUSIONS: Graft choice plays a role in reducing peak endplate pressures. This finding is relevant to implant subsidence, as well as graft loading and remodeling.


Asunto(s)
Materiales Biocompatibles/normas , Trasplante Óseo/normas , Cetonas/normas , Polietilenglicoles/normas , Prótesis e Implantes/normas , Fusión Vertebral/normas , Soporte de Peso , Autoinjertos/diagnóstico por imagen , Autoinjertos/normas , Benzofenonas , Materiales Biocompatibles/administración & dosificación , Fenómenos Biomecánicos/fisiología , Trasplante Óseo/métodos , Humanos , Cetonas/administración & dosificación , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Polietilenglicoles/administración & dosificación , Polímeros , Presión , Fusión Vertebral/instrumentación , Estrés Mecánico , Soporte de Peso/fisiología
19.
Spine J ; 19(11): 1885-1898, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31255790

RESUMEN

BACKGROUND CONTEXT: The potential for osseointegration to provide biological fixation for implants may be related to anatomical site and loading conditions. PURPOSE: To evaluate the influence of anatomical site on osseointegration of 3D-printed implants. STUDY DESIGN: A comparative preclinical study was performed evaluating bone ingrowth in cortical and cancellous sites in long bones as well as lumbar interbody fusion with posterior pedicle screw stabilization using the same 3D-printed titanium alloy design. METHODS: 3D-printed dowels were implanted in cortical bone and cancellous bone in adult sheep and evaluated at 4 and 12 weeks for bone ingrowth using radiography, mechanical testing, and histology/histomorphometry. In addition, a single-level lumbar interbody fusion using cages based on the same 3D-printed design was performed. The aperture was filled with autograft or ovine allograft processed with supercritical carbon dioxide. Interbody fusions were assessed at 12 weeks via radiography, mechanical testing, and histology/histomorphometry. RESULTS: Bone ingrowth in long bone cortical and cancellous sites did not translate directly to interbody fusion cages. While bone ingrowth was robust and improved with time in cortical sites with a line-to-line implantation condition, the same response was not found in cancellous sites even when the implants were placed in a press fit manner. Osseointegration into the porous walls with 3D porous interbody cages was similar to the cancellous implantation sites rather than the cortical sites. The porous domains of the 3D-printed device, in general, were filled with fibrovascular tissue while some bone integration into the porous cages was found at 12 weeks when fusion within the aperture was present. CONCLUSION: Anatomical site, surgical preparation, biomechanical loading, and graft material play an important role in in vivo response. Bone ingrowth in long bone cortical and cancellous sites does not translate directly to interbody fusions.


Asunto(s)
Hueso Esponjoso/cirugía , Hueso Cortical/cirugía , Vértebras Lumbares/cirugía , Oseointegración/fisiología , Impresión Tridimensional , Prótesis e Implantes , Animales , Fenómenos Biomecánicos , Hueso Esponjoso/fisiología , Hueso Cortical/fisiología , Vértebras Lumbares/fisiología , Porosidad , Diseño de Prótesis , Ovinos , Fusión Vertebral/instrumentación , Titanio