Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Mil Med ; 188(Suppl 6): 280-287, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37948225

RESUMEN

INTRODUCTION: Hemorrhage is responsible for 91% of preventable prehospital deaths in combat. Bleeding from anatomic junctions such as the groin, neck, and axillae make up 19% of these deaths, and reports estimate that effective control of junctional hemorrhage could have prevented 5% of fatalities in Afghanistan. Hemostatic dressings are effective but are time-consuming to apply and are limited when proper packing and manual pressure are not feasible, such as during care under fire. CounterFlow-Gauze is a hemostatic dressing that is effective without compression and delivers thrombin and tranexamic acid into wounds. Here, an advanced prototype of CounterFlow-Gauze, containing a range of low thrombin doses, was tested in a lethal swine model of junctional hemorrhage. Outcomes were compared with those of Combat Gauze, the current dressing recommended by Tactical Combat Casualty Care. MATERIALS AND METHODS: CounterFlow-Gauze containing thrombin doses of 0, 20, 200, and 500 IU was prepared. Swine received femoral arteriotomies, and CounterFlow-Gauze was packed into wounds without additional manual compression. In a separate study using a similar model of junctional hemorrhage without additional compression, CounterFlow-Gauze containing 500 IU thrombin was tested and compared with Combat Gauze. In both studies, the primary outcomes were survival to 3 h and volume of blood loss. RESULTS: CounterFlow-Gauze with 200 and 500 IU had the highest 3-h survival, achieving 70 and 75% survival, respectively. CounterFlow-Gauze resulted in mean peak plasma tranexamic acid concentrations of 9.6 ± 1.0 µg/mL (mean ± SEM) within 3 h. In a separate study with smaller injury, CounterFlow-Gauze with 500 IU achieved 100% survival to 3 h compared with 92% in Combat Gauze animals. CONCLUSIONS: An advanced preclinical prototype of CounterFlow-Gauze formulated with a minimized thrombin dose is highly effective at managing junctional hemorrhage without compression. These results demonstrate that CounterFlow-Gauze could be developed into a feasible alternative to Combat Gauze for hemorrhage control on the battlefield.


Asunto(s)
Hemostáticos , Ácido Tranexámico , Animales , Porcinos , Trombina/uso terapéutico , Ácido Tranexámico/farmacología , Ácido Tranexámico/uso terapéutico , Técnicas Hemostáticas , Modelos Animales de Enfermedad , Hemorragia/tratamiento farmacológico , Hemostáticos/farmacología , Hemostáticos/uso terapéutico , Vendajes , Ceguera
2.
Injury ; 53(5): 1603-1609, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35067343

RESUMEN

INTRODUCTION: Non-compressible intra-abdominal hemorrhage (NCIAH) is a major cause of preventable death on the battlefield and in civilian trauma. Currently, it can only be definitively managed with surgery, as there are limited strategies for controlling ongoing NCIAH in the prehospital environment. We hypothesized that a self-propelling thrombin-containing powder (SPTP) could increase survival in a swine model of NCIAH when delivered percutaneously into the closed abdomen using an engineered spray system. MATERIALS AND METHODS: Nineteen swine underwent surgical laparotomy followed by a Grade V liver injury that created massive hemorrhage, before closing the abdomen with sutures. Animals either received treatment with standard of care fluid resuscitation (n=9) or the SPTP spray system (n=10), which consisted of a spray device and a 14 Fr catheter. Using the spray system, SPTP was delivered into a hemoperitoneum identified using a focused assessment with sonography in trauma (FAST) exam. Lactated Ringer's solution was administered to all animals to maintain a mean arterial pressure (MAP) of >50 mmHg. The primary outcome was percentage of animals surviving at three hours following injury. RESULTS: In the swine model of NCIAH, a greater percentage of animals receiving SPTP survived to three hours, although differences were not significant. The SPTP spray system increased the median survival of animals from 1.6 hr in the fluid resuscitation group to 4.3 hr. The SPTP spray system delivered a total mass of 18.5 ± 1.0 g of SPTP. The mean change in intra-abdominal pressure following SPTP delivery was 5.2 ± 1.8 mmHg (mean ± SEM). The intervention time was 6.7 ± 1.7 min. No adverse effects related to the SPTP formulation or the spray system were observed. SPTP was especially beneficial in animals that had either severely elevated lactate concentrations or low mean arterial pressure of <35 mmHg shortly after injury. CONCLUSIONS: This demonstrates proof-of-concept for use of a new minimally invasive procedure for managing NCIAH, which could extend survival time to enable patients to reach definitive surgical care.


Asunto(s)
Hemorragia , Hemostáticos , Abdomen , Animales , Modelos Animales de Enfermedad , Fluidoterapia , Hemorragia/terapia , Hemostáticos/farmacología , Humanos , Polvos , Resucitación/métodos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...