Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
ASAIO J ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701397

RESUMEN

The objective was to investigate the outcomes of concomitant venoarterial extracorporeal membrane oxygenation (ECMO) and left ventricular unloading with Impella (ECPELLA) compared with ECMO alone to treat patients affected by cardiogenic shock. Data from patients needing mechanical circulatory support from 4 international centers were analyzed. Of 438 patients included, ECMO alone and ECPELLA were adopted in 319 (72.8%) and 119 (27.2%) patients, respectively. Propensity score matching analysis identified 95 pairs. In the matched cohort, 30-day mortality rates in the ECMO and ECPELLA were 49.5% and 43.2% ( P = 0.467). The incidences of complications did not differ significantly between groups ( P = 0.877, P = 0.629, P = 1.000, respectively). After a median follow-up of 0.18 years (interquartile range 0.02-2.55), the use of ECPELLA was associated with similar mortality compared with ECMO alone (hazard ratio 0.81, 95% confidence interval 0.54-1.20, P = 0.285), with 1-year overall survival rates of 51.3% and 46.6%, for ECPELLA and ECMO alone, respectively. ECMO alone and ECPELLA are both effective strategies in patients needing mechanical circulatory support for cardiogenic shock, showing similar rates of early and mid-term survival.

3.
IEEE Trans Med Imaging ; PP2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640053

RESUMEN

3D Imaging of the human heart at high frame rate is of major interest for various clinical applications. Electronic complexity and cost has prevented the dissemination of 3D ultrafast imaging into the clinic. Row column addressed (RCA) transducers provide volumetric imaging at ultrafast frame rate by using a low electronic channel count, but current models are ill-suited for transthoracic cardiac imaging due to field-of-view limitations. In this study, we proposed a mechanically curved RCA with an aperture adapted for transthoracic cardiac imaging (24 × 16 mm²). The RCA has a toroidal curved surface of 96 elements along columns (curvature radius rC = 4.47 cm) and 64 elements along rows (curvature radius rR = 3 cm). We implemented delay and sum beamforming with an analytical calculation of the propagation of a toroidal wave which was validated using simulations (Field II). The imaging performance was evaluated on a calibrated phantom. Experimental 3D imaging was achieved up to 12 cm deep with a total angular aperture of 30° for both lateral dimensions. The Contrast-to-Noise ratio increased by 12 dB from 2 to 128 virtual sources. Then, 3D Ultrasound Localization Microscopy (ULM) was characterized in a sub-wavelength tube diameter. Finally, 3D ULM was demonstrated on a perfused ex-vivo swine heart to image the coronary microcirculation.

4.
Arch Cardiovasc Dis ; 117(5): 332-342, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38644067

RESUMEN

BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous syndrome that is poorly defined, reflecting an incomplete understanding of its pathophysiology. AIM: To redefine the phenotypic spectrum of HFpEF. METHODS: The PACIFIC-PRESERVED study is a prospective multicentre cohort study designed to perform multidimensional deep phenotyping of patients diagnosed with HFpEF (left ventricular ejection fraction≥50%), patients with heart failure with reduced ejection fraction (left ventricular ejection fraction≤40%) and subjects without overt heart failure (3:2:1 ratio). The study proposes prospective investigations in patients during a 1-day hospital stay: physical examination; electrocardiogram; performance-based tests; blood samples; cardiac magnetic resonance imaging; transthoracic echocardiography (rest and low-level exercise); myocardial shear wave elastography; chest computed tomography; and non-invasive measurement of arterial stiffness. Dyspnoea, depression, general health and quality of life will be assessed by dedicated questionnaires. A biobank will be established. After the hospital stay, patients are asked to wear a connected garment (with digital sensors) to collect electrocardiography, pulmonary and activity variables in real-life conditions (for up to 14 days). Data will be centralized for machine-learning-based analyses, with the aim of reclassifying HFpEF into more distinct subgroups, improving understanding of the disease mechanisms and identifying new biological pathways and molecular targets. The study will also serve as a platform to enable the development of innovative technologies and strategies for the diagnosis and stratification of patients with HFpEF. CONCLUSIONS: PACIFIC-PRESERVED is a prospective multicentre phenomapping study, using novel analytical techniques, which will provide a unique data resource to better define HFpEF and identify new clinically meaningful subgroups of patients.


Asunto(s)
Insuficiencia Cardíaca , Estudios Multicéntricos como Asunto , Fenotipo , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Estudios Prospectivos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/clasificación , Insuficiencia Cardíaca/terapia , Proyectos de Investigación , Pronóstico , Femenino , Masculino , Anciano , Calidad de Vida , Persona de Mediana Edad
5.
ESC Heart Fail ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38581135

RESUMEN

AIMS: Right ventricular failure after left ventricular assist device (LVAD) implantation is a major concern that remains challenging to predict. We sought to investigate the relationship between preoperative pulmonary artery pulsatility index (PAPi) and mortality after LVAD implantation. METHODS AND RESULTS: A retrospective analysis of the ASSIST-ICD multicentre registry allowed the assessment of PAPi before LVAD according to the formula [(systolic pulmonary artery pressure - diastolic pulmonary artery pressure)/central venous pressure]. The primary endpoint was survival at 3 months, according to the threshold value of PAPi determined by the receiver operating characteristic (ROC) curve. A multivariate analysis including demographic, echographic, haemodynamic, and biological variables was performed to identify predictive factors for 2 year mortality. One hundred seventeen patients were included from 2007 to 2021. The mean age was 58.45 years (±13.16), with 15.4% of women (sex ratio 5.5). A total of 53.4% were implanted as bridge to transplant and 43.1% as destination therapy. Post-operative right ventricular failure was observed in 57 patients (48.7%), with no significant difference between survivors and non-survivors at 1 month (odds ratio 1.59, P = 0.30). The median PAPi for the whole study population was 2.83 [interquartile range 1.63-4.69]. The threshold value of PAPi determined by the ROC curve was 2.84. Patients with PAPi ≥ 2.84 had a higher survival rate at 3 months [PAPi < 2.84: 58.1% [46.3-72.8%] vs. PAPi ≥ 2.84: 89.1% [81.1-97.7%], hazard ratio (HR) 0.08 [0.02-0.28], P < 0.01], with no significant difference after 3 months (HR 0.67 [0.17-2.67], P = 0.57). Other predictors of 2 year mortality were systemic hypertension (HR 4.22 [1.49-11.97], P < 0.01) and diabetes mellitus (HR 4.90 [1.83-13.14], P < 0.01). LVAD implantation as bridge to transplant (HR 0.18 [0.04-0.74], P = 0.02) and heart transplantation (HR 0.02 [0.00-0.18], P < 0.01) were associated with a higher survival rate at 2 years. CONCLUSIONS: Preoperative PAPi < 2.84 was associated with a higher risk of early mortality after LVAD implantation without impacting 2 year outcomes among survivors.

6.
JACC Cardiovasc Imaging ; 17(3): 314-329, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38448131

RESUMEN

The advent of high-frame rate imaging in ultrasound allowed the development of shear wave elastography as a noninvasive alternative for myocardial stiffness assessment. It measures mechanical waves propagating along the cardiac wall with speeds that are related to stiffness. The use of cardiac shear wave elastography in clinical studies is increasing, but a proper understanding of the different factors that affect wave propagation is required to correctly interpret results because of the heart's thin-walled geometry and intricate material properties. The aims of this review are to give an overview of the general concepts in cardiac shear wave elastography and to discuss in depth the effects of age, hemodynamic loading, cardiac morphology, fiber architecture, contractility, viscoelasticity, and system-dependent factors on the measurements, with a focus on clinical application. It also describes how these factors should be considered during acquisition, analysis, and reporting to ensure an accurate, robust, and reproducible measurement of the shear wave.


Asunto(s)
Cardiología , Diagnóstico por Imagen de Elasticidad , Humanos , Valor Predictivo de las Pruebas , Ultrasonografía , Miocardio
7.
Vasc Med ; 29(3): 296-301, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38488572

RESUMEN

Introduction: Takayasu arteritis (TA) is associated with microvascularization of the wall of large arteries and is related to inflammation. Ultrasound localization microscopy (ULM), combining ultrafast ultrasound imaging with microbubble (MB) injection, can track the path of MBs within the arterial wall and thus provide imaging of the vasa vasorum. From the analysis of MB tracks in the common carotid arteries of patients with active TA, we report the presence of microvessels in connection with the carotid lumen (i.e., vasa vasorum interna [VVI]). Methods: ULM maps were obtained on five patients with active disease in the observational single-center series of the TAK-UF study. MB tracks connected to the carotid lumen were automatically identified, allowing the reconstruction of VVI. Results: MB tracking allows us to observe a microvascular network on the inner part of the wall, with some vessels in communication with the carotid lumen. This type of vessel was identified in all patients with active TA (n = 5) with a median of 2.2 [1.1-3.0] vessels per acquisition (2D longitudinal view of 3 cm of the common carotid artery). The blood flow within these vessels is mainly centrifugal; that is, toward the adventitia (88% [54-100] of MB tracks with flow directed to the outer part of the wall). Conclusion: VVI are present in humans in the case of active TA and emphasize the involvement of the intima in the pathological process. ClinicalTrials.gov Identifier: NCT03956394.


Asunto(s)
Microburbujas , Valor Predictivo de las Pruebas , Arteritis de Takayasu , Vasa Vasorum , Humanos , Vasa Vasorum/diagnóstico por imagen , Vasa Vasorum/patología , Arteritis de Takayasu/diagnóstico por imagen , Femenino , Adulto , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/patología , Masculino , Medios de Contraste , Microcirculación , Microscopía Acústica , Persona de Mediana Edad , Microvasos/diagnóstico por imagen , Microvasos/patología , Adulto Joven
8.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Heart Fail Rev ; 29(1): 227-234, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37950833

RESUMEN

As the survival after heart transplantation (HTx) is steadily improving, an increasing number of patients with late cardiac pathologies such as valvular disease is expected to rise. Nevertheless, no guidelines for indication of redo cardiac surgery after HTx exists. The aim of the present systematic review is to describe the results reported in the literature of surgical management of severe aortic and/or mitral valve disease. A systematic review was conducted including studies reporting on adult patients with severe mitral or aortic valve pathology needing surgery after their previous HTx. Exclusion criteria consisted in surgery with no left heart valve surgery, concomitant valve surgery during heart transplant, transcatheter interventions, and heterotopic HTx. A total of 35 papers met our inclusion criteria out of 2755 potentially eligible studies with 44 mitral valve surgery patients and 20 aortic valve surgery patients. In the entire population, the mean time from HTx to reintervention was 6.19 ± 5.22 years. After a mean follow-up of 2.78 ± 3.54 years and 1.53 ± 2.26 years from reintervention, 65.6% mitral and 86.7% aortic patients were reported as alive, respectively. As guidelines on cardiac surgery after HTx are currently lacking, left-sided valvular cardiac reinterventions can be considered a possible therapeutic approach in carefully selected patients. These interventions may not only improve the patient's functional status and survival, but may ultimately reduce the need for re-transplantation due to the chronic shortage of donor hearts. However, the support of more robust data is warranted.


Asunto(s)
Cardiopatías , Trasplante de Corazón , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Humanos , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Donantes de Tejidos , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
11.
Heart Fail Rev ; 29(1): 219-226, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37851119

RESUMEN

Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.


Asunto(s)
Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Persona de Mediana Edad , Femenino , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Trasplante de Corazón/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos
13.
J Biomed Inform ; 149: 104579, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38135173

RESUMEN

With the emergence of health data warehouses and major initiatives to collect and analyze multi-modal and multisource data, data organization becomes central. In the PACIFIC-PRESERVED (PhenomApping, ClassIFication, and Innovation for Cardiac Dysfunction - Heart Failure with PRESERVED LVEF Study, NCT04189029) study, a data driven research project aiming at redefining and profiling the Heart Failure with preserved Ejection Fraction (HFpEF), an ontology was developed by different data experts in cardiology to enable better data management in a complex study context (multisource, multiformat, multimodality, multipartners). The PACIFIC ontology provides a cardiac data management framework for the phenomapping of patients. It was built upon the BMS-LM (Biomedical Study -Lifecycle Management) core ontology and framework, proposed in a previous work to ensure data organization and provenance throughout the study lifecycle (specification, acquisition, analysis, publication). The BMS-LM design pattern was applied to the PACIFIC multisource variables. In addition, data was structured using a subset of MeSH headings for diseases, technical procedures, or biological processes, and using the Uberon ontology anatomical entities. A total of 1372 variables were organized and enriched with annotations and description from existing ontologies and taxonomies such as LOINC to enable later semantic interoperability. Both, data structuring using the BMS-LM framework, and its mapping with published standards, foster interoperability of multimodal cardiac phenomapping datasets.


Asunto(s)
Ontologías Biológicas , Cardiología , Insuficiencia Cardíaca , Humanos , Manejo de Datos , Insuficiencia Cardíaca/terapia , Cuidados Paliativos , Semántica , Volumen Sistólico , Estudios Clínicos como Asunto
14.
Lancet ; 402(10419): 2317-2325, 2023 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-37972628

RESUMEN

BACKGROUND: Calcific aortic stenosis is commonly treated using surgical or transcatheter aortic valve replacement; however, many patients are not considered suitable candidates for these interventions due to severe comorbidities and limited life expectancy. As such, non-invasive therapies might offer alternative therapeutic possibilities in these patients. This study aimed to assess the safety of non-invasive ultrasound therapy and its ability to improve valvular function by softening calcified valve tissue. METHODS: This prospective, multicentre, single-arm series enrolled 40 adult patients with severe symptomatic aortic valve stenosis at three hospitals in France, the Netherlands, and Serbia between March 13, 2019, and May 8, 2022. Patients were treated with transthoracically delivered non-invasive ultrasound therapy. Follow-ups were scheduled at 1, 3, 6, 12, and 24 months. The primary endpoints were procedure-related deaths within 30 days and improved valve function. We report the 6-month data. This study is registered at ClinicalTrials.gov, NCT03779620 and NCT04665596. FINDINGS: 40 high-risk patients with a mean Society of Thoracic Surgeons score of 5·6% (SD 4·4) and multiple severe comorbidities were included. The primary endpoint, procedure-related mortality, did not occur; furthermore, no life-threatening or cerebrovascular events were reported. Improved valve function was confirmed up to 6 months, reflected by a 10% increase in mean aortic valve area from 0·58 cm2 (SD 0·19) at baseline to 0·64 cm2 (0·21) at follow-up (p=0·0088), and a 7% decrease in mean pressure gradient from 41·9 mm Hg (20·1) to 38·8 mm Hg (17·8; p=0·024). At 6 months, the New York Heart Association score had improved or stabilised in 24 (96%) of 25 patients, and the mean Kansas City Cardiomyopathy Questionnaire score had improved by 33%, from 48·5 (SD 22·6) to 64·5 (21·0). One serious procedure-related adverse event occurred in a patient who presented with a transient decrease in peripheral oxygen saturation. Non-serious adverse events included pain, discomfort during treatment, and transient arrhythmias. INTERPRETATION: This novel, non-invasive ultrasound therapy for calcified aortic stenosis proved to be safe and feasible. FUNDING: Cardiawave.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Terapia por Ultrasonido , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Perfusion ; : 2676591231215282, 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37944166

RESUMEN

INTRODUCTION: There are several types of surface treatments (coatings) aimed at improving the biocompatibility of cardiopulmonary bypass (CPB) circuit. Some coatings appear to require higher doses of heparin to maintain anticoagulation goals, and some of them might induce postoperative coagulopathy. In this study, we compared the amount of heparin required, postoperative bleeding, and inflammatory response according to three types of coatings. METHOD: We retrospectively included 300 consecutive adult patients who underwent cardiac surgery with CPB and received one of three coatings (Phisio®, Trillium®, and Xcoating™). Our primary objective was to compare, according to coating, the amount of heparin required to maintain an ACT > 400s during CPB. Our secondary objectives were to compare postoperative bleeding for 48 h and CRP rate. RESULTS: Baseline characteristics were comparable between groups except for age and preoperative CRP. We did not find a significant difference between the 3 coatings regarding the amount of heparin reinjected. However, we found less postoperative bleeding with the Xcoating™ circuit compared to the Phisio® circuit (-149 mL [-289; -26.5]; p = 0.02) and a lower elevation of CRP with the Phisio® circuit (2.8 times higher than preoperative CRP) compared to Trillium® (4.9 times higher) and Xcoating™ (6.4 times higher); p < 10-3. CONCLUSION: The choice of coating did not influence the amount of heparin required during CPB; however, the post-CPB inflammatory syndrome may be impacted by this choice.

16.
Artículo en Inglés | MEDLINE | ID: mdl-37951484

RESUMEN

An increasing number of patients experience late valvular disease after heart transplantation (HTx). While mostly being primarily addressed through surgical interventions, transcatheter valve procedures to treat these conditions are rising, particularly for unsuitable surgical candidates. This review aims at analyzing the outcomes of transcatheter valvular procedures in this subset of patients. A systematic review was conducted including studies reporting on adult patients requiring any form of transcatheter valvular intervention after a previous HTx. Studies involving a surgical approach, heterotopic heart transplants, or concomitant procedures performed during the transplant itself were excluded. Twenty-five articles with a total of 33 patients met the inclusion criteria, 10 regarding the aortic valve (14 patients), 5 the mitral valve (6 patients), and 6 the tricuspid valve (13 patients). In two cases, the procedure was recommended to stabilize the valvular lesion before re-transplantation, as both were very young patients. Overall, the mean time from heart transplantation to reintervention was 14.7 ± 9.5 years. The mean follow-up was 15.5 ± 13.5 months, and only one patient died 22.3 months after the intervention. There is a growing emergence of transcatheter interventions for valvular disease after heart transplantation, especially in cases where surgery is deemed high-risk or prohibitive. A different strategy may also be considered in young patients to permit longer allograft life before later re-transplantation. Although encouraging outcomes have been documented, additional research is required to establish the most appropriate approach within this specific subset of patients.

17.
Sci Adv ; 9(40): eadi4252, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37792931

RESUMEN

Blood pressure measurement is the most widely performed clinical exam to predict mortality risk. The gold standard for its noninvasive assessment is the auscultatory method, which relies on listening to the so-called "Korotkoff sounds" in a stethoscope placed at the outlet of a pneumatic arm cuff. However, more than a century after their discovery, the origin of these sounds is still debated, which implies a number of clinical limitations. We imaged the Korotkoff sound generation in vivo at thousands of images per second using ultrafast ultrasound. We showed with both experience and theory that Korotkoff sounds are paradoxically not sound waves emerging from the brachial artery but rather shear vibrations conveyed in surrounding tissues by the nonlinear pulse wave propagation. When these shear vibrations reached the stethoscope, they were synchronous, correlated, and comparable in intensity with the Korotkoff sounds. Understanding this mechanism could ultimately improve blood pressure measurement and provide additional understanding of arterial mechanical properties.


Asunto(s)
Determinación de la Presión Sanguínea , Sonido , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Vibración , Extremidad Superior
18.
Cureus ; 15(9): e44688, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37809256

RESUMEN

In the current era of improved survival after orthotopic heart transplantation, post-transplant valve dysfunction is not an uncommon occurrence. The first treatment is medical management, but when it fails, surgery, possibly as retransplantation, may be needed. However, due to the scarcity of donor hearts, efforts are being made on the preservation of the cardiac allograft function by conventional operations in lieu of retransplantation. In this case report, we present a patient developing severe aortic valve insufficiency and moderate-to-severe functional tricuspid valve insufficiency five years after cardiac transplant, leading to progressive clinical deterioration and heart failure symptoms. The aortic valve was replaced with an Edwards Inspiris Resilia Nr. 23 biological prosthesis, and the tricuspid valve was repaired with a Medtronic Contour 3D Nr. 28 annuloplasty. The postoperative course was uneventful, and the patient remained well six months after her reintervention. In the literature, cases of patients undergoing valve operations following their heart transplants have already been described. However, to the best of our knowledge, this is the first case report describing a concomitant procedure of aortic valve replacement and tricuspid valve repair in an adult patient occurring five years after her cardiac transplant.

19.
Eur Heart J Acute Cardiovasc Care ; 12(12): 821-830, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37713615

RESUMEN

AIMS: Short-term mechanical circulatory support (STMCS) may be used as an intentional escalation strategy to treat refractory cardiogenic shock (rCS). However, with growing technical possibilities, making the right choice at the right time can be challenging. We established a shock team in January 2013 comprising a cardiac anaesthetist-intensivist, an interventional cardiologist, and a cardiac surgeon. Since then, a diagnosis of rCS has triggered a multidisciplinary team meeting based on a common algorithm. This study aimed to compare the decision-making process for STMCS for rCS before (2007-2013) and after (2013-2019) the creation of the shock team. METHODS AND RESULTS: This before-and-after cohort study was conducted over a 156-month period. Post-cardiotomy rCS were excluded. The primary outcome was a 1-year survival rate. In total, 250 consecutive adult patients were included in the analysis (84 in the control group and 166 in the shock team group). At baseline, the CardShock score was not different between the two groups (5[3-5] vs. 5[4-6], P = 0.323). The 1-year survival rate was significantly higher in the shock team group compared with the control group (59% vs. 45%, P = 0.043). After a Cox regression analysis, the shock team intervention was independently associated with a significantly improved 1-year survival rate (HR: 0.592, 95% CI: 0.398-0.880, P = 0.010). CONCLUSION: A multidisciplinary shock team-based decision for STMCS device implantation in rCS is associated with better 1-year survival rates.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Adulto , Humanos , Estudios de Cohortes , Resultado del Tratamiento , Estudios Retrospectivos
20.
Eur J Vasc Endovasc Surg ; 66(6): 821-829, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37567339

RESUMEN

OBJECTIVE: A proximal scallop design allows aortic arch repair without complex endovascular manipulation in the aortic arch. The aim was to assess the safety and efficacy at one year of the Relay proximal scallop stent graft. METHODS: A prospective multicentre study evaluated consecutive patients treated with the Relay proximal scallop stent graft in 10 French aortic centres. All consecutive patients eligible for elective thoracic endovascular repair with proximal scallop in the 10 participating centres between January 2015 and July 2018 were included. Primary endpoints were 30 day mortality, stroke, and spinal cord ischaemia (SCI) rates. Outcomes including safety and efficacy, technical and clinical success, all cause death, neurological events, vessel patency, and device specific complications were analysed. Survival and survival without severe complications were estimated using Kaplan-Meier estimates. RESULTS: Ten aortic centres treated 40 patients for thoracic aortic aneurysm (45%), penetrating atherosclerotic aneurysm (30%), and dissection (25%). Half of the procedures (50%) targeted zone 0 of the aortic arch (zone 0 in 17.5% and zones 0/1 in 32.5%), 37.5% targeted zone 2 (35% zone 2 alone; 2.5% zones 1/2), and 15% targeted zone 1 (12.5% zone 1 alone). Median follow up was one year. Thirty day mortality, stroke, and SCI rates were 10%, 5%, and 0% respectively. Primary technical success was 95%. Type Ia, Ib, and III endoleaks rates were 5.4%, 0%, and 0% respectively at one month. The overall mortality rate at one year was 17.5%. Aneurysm expansion was > 5 mm in one case at one year associated with type Ia endoleak (3%). There was no supra-aortic trunk thrombosis, one (2%) graft kink, and no migration. CONCLUSION: One year outcomes showed that the Relay proximal scallop stent graft is an acceptable answer to thoracic aortic disease to deal with short proximal landing zones.


Asunto(s)
Aneurisma , Aneurisma de la Aorta Torácica , Enfermedades de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Stents/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/complicaciones , Endofuga/etiología , Endofuga/cirugía , Accidente Cerebrovascular/cirugía , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...