Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38452886

RESUMEN

BACKGROUND: In light of the updated lowered threshold for diagnosing pulmonary hypertension (PH), the reversibility of precapillary PH with left ventricular assist device (LVAD) and the associated post-heart transplantation (HT) outcomes remain unclear. METHODS: Using data from the United Network for Organ Sharing database, we aimed to investigate predictors of persistent precapillary PH in HT recipients bridged with LVAD and examine the interrelated post-HT survival using the updated pulmonary vascular resistance (PVR) cutoff of >2 Wood units for precapillary PH. RESULTS: Among 2169 HT recipients bridged with LVAD, 1299 had PVR >2 at baseline; 551 (42.4%) of whom normalized their PVR ≤2 and 748 (57.6%) remained with elevated PVR >2 after LVAD implantation. Female sex (adjusted odds ratio [aOR]; 2.22, 95% confidence interval [CI], 1.61-3.07; P < .001) and inotrope treatment at listing (aOR, 1.31; 95% CI, 1.03-1.66; P = .028) were associated with persistently elevated PVR after LVAD. Conversely, longer duration of LVAD support (aOR, 0.74; 95% CI, 0.65-0.84; P < .001) and use of HeartMate II (aOR, 0.74; CI, 0.59-0.93; P = .011) were found to be protective against persistently elevated PVR after LVAD. Persistently elevated PVR >2 after LVAD was associated with increased risk of death compared with those who normalized their PVR (adjusted hazard ratio [aHR], 1.26; 95% CI, 1.01-1.57; P = .037). However, the normalized PVR post-LVAD group had comparable survival with those with PVR ≤2 at baseline (aHR, 0.76; 95% CI, 0.57-1.02; P = .07). CONCLUSIONS: Many recipients of HT bridged with LVAD remain with PVR >2 after LVAD implantation, which is associated with increased risk of death after HT compared with patients with normalized PVR after LVAD.

2.
Biomedicines ; 11(3)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36979735

RESUMEN

Left ventricular assist devices (LVADs) have been increasingly used in patients with advanced heart failure, either as a destination therapy or as a bridge to heart transplant. Continuous flow (CF) LVADs have revolutionized advanced heart failure treatment. However, significant vascular pathology and complications have been linked to their use. While the newer CF-LVAD generations have led to a reduction in some vascular complications such as stroke, no major improvement was noticed in the rate of other vascular complications such as gastrointestinal bleeding. This review attempts to provide a comprehensive summary of the effects of CF-LVAD on vasculature, including pathophysiology, clinical implications, and future directions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...