Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Bone ; 165: 116571, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36174928

RESUMEN

Identification of bone erosions and quantification of erosion volume is important for rheumatoid arthritis diagnosis, and can add important information to evaluate disease progression and treatment effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) is well suited for this purpose, however analysis methods are not widely available. The purpose of this study was to develop an open-source software tool for the identification and quantification of bone erosions using images acquired by HR-pQCT. The collection of modules, Bone Analysis Modules (BAM) - Erosion, implements previously published erosion analysis techniques as modules in 3D Slicer, an open-source image processing and visualization tool. BAM includes a module to automatically identify cortical interruptions, from which erosions are manually selected, and a hybrid module that combines morphological and level set operations to quantify the volume of bone erosions. HR-pQCT images of the second and third metacarpophalangeal (MCP) joints were acquired in patients with RA (XtremeCT, n = 14, XtremeCTII, n = 22). The number of cortical interruptions detected by BAM-Erosion agreed strongly with the previously published cortical interruption detection algorithm for both XtremeCT (r2 = 0.85) and XtremeCTII (r2 = 0.87). Erosion volume assessment by BAM-Erosion agreed strongly (r2 = 0.95) with the Medical Image Analysis Framework. BAM-Erosion provides an open-source erosion analysis tool that produces comparable results to previously published algorithms, with improved options for visualization. The strength of the tool is that it implements multiple image processing algorithms for erosion analysis on a single, widely available, open-source platform that can accommodate future updates.


Asunto(s)
Artritis Reumatoide , Humanos , Artritis Reumatoide/diagnóstico por imagen , Articulación Metacarpofalángica , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador , Progresión de la Enfermedad
2.
Quant Imaging Med Surg ; 10(2): 314-325, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32190559

RESUMEN

BACKGROUND: Joint space assessment for rheumatoid arthritis (RA) by ordinal conventional radiographic scales is susceptible to floor and ceiling effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides superior resolution, and may detect earlier changes. The goal of this work was to compare existing 3D methods to calculate joint space width (JSW) metrics in human metacarpophalangeal (MCP) joints with HR-pQCT and reach consensus for future studies. Using the consensus method, we established reproducibility with repositioning as well as feasibility for use in second-generation HR-pQCT scanners. METHODS: Three published JSW methods were compared using datasets from individuals with RA from three research centers. A SPECTRA consensus method was developed to take advantage of strengths of the individual methods. Using the SPECTRA method, reproducibility after repositioning was tested and agreement between scanner generations was also established. RESULTS: When comparing existing JSW methods, excellent agreement was shown for JSW minimum and mean (ICC 0.987-0.996) but not maximum and volume (ICC 0.000-0.897). Differences were identified as variations in volume definitions and algorithmic differences that generated high sensitivity to boundary conditions. The SPECTRA consensus method reduced this sensitivity, demonstrating good scan-rescan reliability (ICC >0.911) except for minimum JSW (ICC 0.656). There was strong agreement between results from first- and second-generation HR-pQCT (ICC >0.833). CONCLUSIONS: The SPECTRA consensus method combines unique strengths of three independently-developed algorithms and leverages underlying software updates to provide a mature analysis to measure 3D JSW. This method is robust with respect to repositioning and scanner generations, suggesting its suitability for detecting change.

3.
PLoS One ; 13(7): e0200331, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29985943

RESUMEN

OBJECTIVES: To develop a scoring method to visually score cortical interruptions in finger joints on High-Resolution peripheral Quantitative Computed Tomography (HR-pQCT), determine its intra- and inter-reader reliability and test its feasibility. METHODS: The scoring method was developed by integrating results from in-depth discussions with experts, consensus meetings, multiple reading experiments and the literature. Cortical interruptions were scored by two independent readers in an imaging dataset with finger joints from patients with rheumatoid arthritis (RA) and healthy controls and assessed for adjacent trabecular distortion. Reliability for the total number of cortical interruptions per joint and per quadrant was calculated using intraclass correlation coefficient (ICC). Feasibility was tested by recording the time to analyze one joint. RESULTS: In 98 joints we identified 252 cortical interruptions, 17% had trabecular distortion. Mean diameter of the interruptions was significantly larger in patients with RA compared with healthy controls (0.88 vs 0.47 mm, p = 0.03). Intra-reader reliability was ICC 0.88 (95% CI 0.83;0.92) per joint and ICC 0.69 (95% CI 0.65;0.73) per quadrant. Inter-reader reliability was ICC 0.48 (95% CI 0.20;0.67) per joint and ICC 0.56 (95% CI 0.49;0.62) per quadrant. The time to score one joint was mean 9.2 (SD 4.9) min. CONCLUSIONS: This scoring method allows detection of small cortical interruptions on HR-pQCT imaging of finger joints, which is promising for use in clinical studies.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Hueso Cortical/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Adulto , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
4.
J Bone Miner Res ; 33(9): 1676-1685, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29750836

RESUMEN

Small cortical interruptions may be the first sign of an erosion, and more interruptions can be found in patients with rheumatoid arthritis (RA) compared with healthy subjects. First, we compared the number and size of interruptions in patients with RA with healthy subjects using high-resolution peripheral quantitative CT (HR-pQCT). Second, we investigated the association between structural damage and inflammatory markers on conventional radiography (CR) and MRI with interruptions on HR-pQCT. Third, the added value of HR-pQCT over CR and MRI was investigated. The finger joints of 39 patients with RA and 38 healthy subjects were examined through CR, MRI, and HR-pQCT. CRs were scored using the Sharp/Van der Heijde method. MRI images were analyzed for the presence of erosions, bone marrow edema, and synovitis. HR-pQCT images were analyzed for the number, surface area, and volume of interruptions using a semiautomated algorithm. Descriptives were calculated and associations were tested using generalized estimating equations. Significantly more interruptions and both a larger surface area and the volume of interruptions were detected in the metacarpophalangeal joints of patients with RA compared with healthy subjects (median, 2.0, 1.42 mm2 , and 0.48 mm3 versus 1.0, 0.69 mm2 , and 0.23 mm3 , respectively; all p < 0.01). Findings on CR and MRI were significantly associated with more and larger interruptions on HR-pQCT (prevalence ratios [PRs] ranging from 1.03 to 7.74; all p < 0.01) in all subjects, and were consistent in patients with RA alone. Having RA was significantly associated with more and larger interruptions on HR-pQCT (PRs, 2.33 to 5.39; all p < 0.01), also after adjustment for findings on CR or MRI. More and larger cortical interruptions were found in the finger joints of patients with RA versus healthy subjects, also after adjustment for findings on CR or MRI, implying that HR-pQCT imaging may be of value in addition to CR and MRI for the evaluation of structural damage in patients with RA. © 2018 The Authors. Journal of Bone and Mineral Research Published by Wiley Periodicals Inc.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Hueso Cortical/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Artritis Reumatoide/patología , Densidad Ósea , Hueso Cortical/patología , Articulaciones de los Dedos/patología , Humanos , Persona de Mediana Edad
5.
J Rheumatol ; 43(10): 1914-1920, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27698106

RESUMEN

OBJECTIVE: Conventional radiographs (CR) of the hands are the gold standard for imaging bone erosions. The presence of bone erosions, reflected by the presence of cortical breaks, is a poor prognostic factor in patients with rheumatoid arthritis (RA). The availability of high-resolution peripheral quantitative computed tomography (HR-pQCT) enables detailed investigation of cortical breaks in rheumatic diseases. The aim of this image review is to show HR-pQCT images of the spectrum of cortical breaks with and without underlying trabecular bone changes in metacarpophalangeal (MCP) joints of healthy controls (HC) and patients with RA, with corresponding images on CR and magnetic resonance imaging (MRI). METHODS: Second and third MCP joints of 41 patients (of which 10 were early RA with ≤ 2 years and 24 longstanding RA with ≥ 10 years of disease duration) and 38 HC were imaged by CR, MRI, and HR-pQCT (XtremeCT1, Scanco Medical AG). Representative images of the spectrum of cortical breaks were selected. RESULTS: Cortical breaks were found in early and longstanding RA, but also in HC. They were heterogeneous in size, location, and number per joint, with a variety of surrounding cortical and underlying trabecular bone characteristics. CONCLUSION: Using HR-pQCT images of MCP joints, heterogeneous cortical breaks with and without surrounding trabecular bone changes were found, not only in RA but also in HC. The underlying mechanisms and significance of this spectrum of cortical breaks as found with high 3-D resolution needs further investigation.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Fracturas Óseas/diagnóstico por imagen , Articulaciones de la Mano/diagnóstico por imagen , Articulaciones de la Mano/lesiones , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Hueso Esponjoso/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Articulación Metacarpofalángica/diagnóstico por imagen , Persona de Mediana Edad
6.
J Arthroplasty ; 31(12): 2773-2777, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27394075

RESUMEN

BACKGROUND: Historically it has been suggested that noise-induced hearing loss (NIHL) affects approximately 50% of the orthopedic surgery personnel. This noise may be partially caused by the use of powered saw systems that are used to make the bone cuts. The first goal was to quantify and compare the noise emission of these different saw systems during total knee arthroplasty (TKA) surgery. A second goal was to estimate the occupational NIHL risk for the orthopedic surgery personnel in TKA surgery by quantifying the total daily noise emission spectrum during TKA surgery and to compare this to the Dutch Occupational Health Organization guidelines. METHODS: A conventional sagittal oscillating blade system with a full oscillating blade and 2 newer oscillating tip saw systems (handpiece and blade) were compared. Noise level measurements during TKA surgery were performed during cutting and hammering, additionally surgery noise profiles were made. RESULTS: The noise level was significantly lower for the oscillating tip saw systems compared to the conventional saw system, but all were in a range that can cause NIHL. The conventional system handpiece produced a considerable higher noise level compared to oscillating tip handpiece. CONCLUSION: NIHL is an underestimated problem in the orthopedic surgery. Solutions for decreasing the risk of hearing loss should be considered. The use of oscillating tip saw systems have a reduced noise emission in comparison with the conventional saw system. The use of these newer systems might be a first step in decreasing hearing loss among the orthopedic surgery personnel.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Huesos/cirugía , Ruido , Exposición Profesional/análisis , Ortopedia/estadística & datos numéricos , Pérdida Auditiva Provocada por Ruido/etiología , Humanos , Ruido/efectos adversos , Exposición Profesional/efectos adversos , Instrumentos Quirúrgicos
7.
Nicotine Tob Res ; 12(9): 913-8, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20675363

RESUMEN

INTRODUCTION: The objective of this study was to investigate the effect of smoking cues in movies on immediate smoking behavior. We tested whether smokers who are confronted with smoking characters in a movie smoke more cigarettes while watching than those confronted with non-smoking characters and whether this effect is less profound when smokers are more involved in the narrative (i.e., transportation). METHOD: Using an experimental design, 60 daily smokers were assigned randomly to one of two movie conditions (smoking vs. non-smoking characters). Participants were exposed to a 72-min movie clip and were allowed to smoke while watching the movie. Transportation and smoking habits were assessed with a questionnaire afterward. RESULTS: The results showed a significant interaction effect between movie condition and transportation on immediate smoking behavior, indicating that smokers who were less transported smoked significantly more cigarettes when they were exposed to smoking characters compared with non-smoking characters. DISCUSSION: These results call for (a) increasing the awareness among people about the effect smoking cues in movies might have and (b) stricter control over smoking cues in movies.


Asunto(s)
Conducta Adictiva/psicología , Señales (Psicología) , Películas Cinematográficas , Comunicación Persuasiva , Estimulación Luminosa/métodos , Fumar/psicología , Adulto , Nivel de Alerta , Actitud Frente a la Salud , Femenino , Humanos , Masculino , Persona de Mediana Edad , Motivación , Países Bajos , Medio Social , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...