Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Dent Mater ; 39(8): 729, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37393151

RESUMEN

OBJECTIVES: To obtain new generation dental composites with improved performance properties compared to currently available dental fillings on the market and to determine the influence of new initiating systems on final product parameters such as degree of cure, hardness, color, and shrinkage. METHODS: In order to verify the effectiveness of the developed initiating systems, typical spectroscopic, electrochemical, and kinetic studies using the real-time FT-IR method were shown. Moreover, paste dental fillings were prepared, the compositions were irradiated with the dental lamp, and the degrees of cross-linking were measured by Raman spectroscopy. The polymerization shrinkage was also determined using the rheometer. In addition, their hardness was examined on the Shore scale. Finally, the color analysis of the composites in the L*a*b* color space was compared with the VITA CLASSIC colorant. RESULTS: It was shown that, due to their excellent spectroscopic and electrochemical properties, new quinazolin-2-one can act as co-initiators in cationic and radical photopolymerization. It was demonstrated that the most effective composite containing the initiator system in the form of 3-SCH3Ph-Q, IOD, MDEA, and an inorganic filler as nanometric silica and a bonding agent is cured more than 90% after just 1 cycle of dental lamp exposure (30 s), the hardness of the composite after curing on the Shor Scale is 82 ± 4, and the polymerization shrinkage is less than 2.8%. SIGNIFICANCE: The article demonstrates effective new initiator systems as an alternative to CQ/amine for obtaining new-generation dental composites. The developed dental composites are a big competition to the currently used dental fillings on the market.

2.
Sensors (Basel) ; 20(11)2020 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-32471215

RESUMEN

Novel fluorescent sensors with electron-donating or electron-withdrawing substituents incorporated into a chromophore group based on 2,6-diphenylpyridine were designed and synthesised. The spectroscopic properties of these compounds were studied. Moreover, the positive solvatochromism of 2,6-bis-(4-methylsulphanylphenyl)pyridine (PT-SCH3) in selected solvents was studied by measurement of the absorption and emission spectra and analysed using the Dimroth-Reichardt solvent parameter set. After that, the performance of a series of 2,6-diphenylpyridine derivatives as fluorescent molecular sensors for monitoring free-radical and cationic photopolymerization processes by the Fluorescence Probe Technique (FPT) was studied. As a consequence of this stage of research, the effect of substituents on the sensitivity of the 2,6-diphenylpyridine derivatives as sensors during photopolymerization has been evaluated and discussed. It has been found that compounds containing strong electron-donating substituent (PT-SCH3) slightly shift their fluorescence spectrum during the free-radical polymerization of monomer, which enables the monitoring of the polymerization progress using the fluorescence intensity ratio measured at two different wavelengths as the progress indicator. The position of the fluorescence spectrum of 2,6-diphenylpyridine derivatives with electron-withdrawing substituents is practically insensitive to changes occurring in their environment. Hence, it is recommended to use these compounds with different indicators of the progress of the photopolymerization process based on normalised intensity of fluorescence (Imax/I0). Among the compounds studied, 2,6-bis(4-methylsulphanylphenyl)pyridine (PT-SCH3) turned out to be the best fluorescent sensor for the purpose of monitoring free-radical polymerization by FPT. Consequently, the dual application of the selected 2,6-diphenylpyridine derivatives is proposed: (a) as fluorescent sensors for monitoring the free-radical photopolymerization progress, and (b) as spectroscopic sensors for the determination of efficiencies of the generation of superacids by cationic photoinitiators during the cationic photopolymerization process. Finally, a new method for determining the relative efficiency of the photogeneration of superacids during the photo cleavage of onium salt has been devised and applied for the evaluation of the performance of 2,6-diphenylpyridine derivatives.

3.
Polymers (Basel) ; 11(11)2019 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-31731521

RESUMEN

The applicability of new 1,6-diphenylquinolin-2-oneas derivatives as fluorescent molecular sensors for monitoring the progress of photopolymerisation processes by Fluorescence Probe Technique (FPT) has been tested. The progress of cationic, free-radical and thiol-ene photopolymerisation for commercially available monomers: triethylene glycol divinyl ether (TEGDVE), trimethylolpropane triacrylate (TMPTA) and trimethylpropane tris(3-mercaptopropropionate) (MERCAPTO) was monitored. It was found that new derivatives of 1,6-diphenylquinolin-2-one shifted their fluorescence spectra towards shorter wavelengths with the progress of polymerisation, which enabled monitoring the progress in terms of fluorescence intensity ratios as the progress indicator. Derivatives of 1,6-diphenylquinolin-2-one show sensitivity to changes in both polarity and viscosity in the surrounding microenvironment during photopolymerisation processes. Therefore, it was shown that they are good candidates to act as fluorescent sensors for monitoring the kinetics of very quick processes, such as photopolymerisation processes. Furthermore, the effect of the nature of substituents attached to the 1,6-diphenylquinolin-2-one ring on the characteristics of emission spectra was identified. Moreover, the sensitivity of fluorescent sensors was compared with commercially available model sensors, such as 7-diethylamino-4-methylcoumarin (Coumarin 1) and trans-2-(2',5'-dimethoxyphenyl)ethenyl-2,3,4,5,6-pentafluorobenzene (25ST). Moreover, it was also proven that selected derivatives of 1,6-diphenylquinolin-2-one exhibit an accelerating effect on the progress of cationic photopolymerisation of vinyl monomers (TEGDVE). Thus, the new 1,6-diphenylquinolin-2-one derivatives can be successfully used both as molecular fluorescence sensors to monitor the progress of photopolymerisation processes and as diaryliodonium salt photosensitisers to initiate cationic photopolymerisation processes in a UV-A range of 365 nm.

4.
Analyst ; 141(4): 1390-7, 2016 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-26765153

RESUMEN

High spatially resolved Raman microscopy was applied to study the early apoptosis in endothelial cells and chemical and structural changes induced by this process. Application of cluster analysis enabled separation of signals due to various subcellular organelles and compartments such as the nuclei, nucleoli, endoplasmic reticulum or cytoplasm and analysis of alterations locally at the subcellular level. Different stimuli, i.e. Fas ligand, a tumor necrosis factor, and cycloheximide, an inhibitor of eukaryotic protein biosynthesis, were applied to induce apoptotic mechanisms. Due to different mechanisms of action, the changes observed in subcellular structures were different for FasL and cycloheximide. Although in both cases a statistically significant decrease of the protein level was observed in all studied cellular structures, the increase of the nucleic acids content locally in apoptotic nuclei was considerably more pronounced upon FasL-induced apoptosis compared to the cycloheximide one. Additionally, apoptosis invokes also a decrease of the proteins with the α-helix protein structure selectively for FasL in the cytoplasm and endoplasmic reticulum.


Asunto(s)
Apoptosis/efectos de los fármacos , Cicloheximida/farmacología , Proteína Ligando Fas/farmacología , Células Endoteliales de la Vena Umbilical Humana/citología , Espacio Intracelular/efectos de los fármacos , Espacio Intracelular/metabolismo , Microscopía/métodos , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos , Espectrometría Raman
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...