Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(5)2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38785702

RESUMEN

Legionella pneumophila has been pinpointed by the World Health Organization as the highest health burden of all waterborne pathogens in the European Union and is responsible for many disease outbreaks around the globe. Today, standard analysis methods (based on bacteria culturing onto agar plates) need several days (~12) in specialized analytical laboratories to yield results, not allowing for timely actions to prevent outbreaks. Over the last decades, great efforts have been made to develop more efficient waterborne pathogen diagnostics and faster analysis methods, requiring further advancement of microfluidics and sensors for simple, rapid, accurate, inexpensive, real-time, and on-site methods. Herein, a lab-on-a-chip device integrating sample preparation by accommodating bacteria capture, lysis, and DNA isothermal amplification with fast (less than 3 h) and highly sensitive, colorimetric end-point detection of L. pneumophila in water samples is presented, for use at the point of need. The method is based on the selective capture of viable bacteria on on-chip-immobilized and -lyophilized antibodies, lysis, the loop-mediated amplification (LAMP) of DNA, and end-point detection by a color change, observable by the naked eye and semiquantified by computational image analysis. Competitive advantages are demonstrated, such as low reagent consumption, portability and disposability, color change, storage at RT, and compliance with current legislation.


Asunto(s)
Colorimetría , Legionella pneumophila , Colorimetría/instrumentación , Colorimetría/métodos , Factores de Tiempo , Procedimientos Analíticos en Microchip/métodos , Legionella pneumophila/genética , Legionella pneumophila/aislamiento & purificación , Porosidad , ADN Bacteriano/genética , ADN Bacteriano/aislamiento & purificación , Microbiología del Agua
2.
Biosens Bioelectron ; 215: 114570, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35850040

RESUMEN

Silicon photonic probes based on broad-band Mach-Zehnder interferometry are explored for the first time as directly immersible immunosensors alleviating the need for microfluidics and pumps. Each probe includes two U-shaped waveguides allowing light in- and out-coupling from the same chip side through a bifurcated fiber and a mechanical coupler. At the opposite chip side, two Mach-Zehnder interferometers (MZI) are located enabling real-time monitoring of binding reactions by immersion of this chip side into a sample. The sensing arm windows of the two MZIs have different length resulting in two distinct peaks in the Fourier domain, the phase shift of which can be monitored independently through Fast Fourier Transform of the output spectrum. The photonic probes analytical potential was demonstrated through detection of antibodies against SARS-CoV-2 in human serum samples. For this, one MZI was functionalized with the Receptor Binding Domain (RBD) of SARS-CoV-2 Spike 1 protein, and the other with bovine serum albumin to serve as reference. The biofunctionalized probes were immersed for 10 min in human serum sample and then for 5 min in goat anti-human IgG Fc specific antibody solution. Using a humanized rat antibody against SARS-CoV-2 RBD, a detection limit of 20 ng/mL was determined. Analysis of human serum samples indicated that the proposed sensor discriminated completely non-infected/non-vaccinated from vaccinated individuals, and the antibodies levels determined correlated well with those determined in the same samples by ELISA. These results demonstrated the potential of the proposed sensor to serve as an efficient tool for expeditious point-of-care testing.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Animales , Anticuerpos , Anticuerpos Antivirales , Técnicas Biosensibles/métodos , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Inmunoensayo , Ratas , SARS-CoV-2 , Silicio/química
3.
Analyst ; 146(2): 529-537, 2021 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-33179631

RESUMEN

Mozzarella di Bufala Campana and Feta are two cheeses with Protected Designation of Origin the fraudulent adulteration of which with bovine milk must be routinely checked to ensure that consumers actually buy these high-end products and avoid health issues related to bovine milk allergy. Here, we employed, for the first time, a silicon-based photonic immunosensor for the detection of mozzarella and feta adulteration with bovine milk. The photonic immunosensor used relies on Mach-Zehnder interferometers monolithically integrated along with their respective light sources on a silicon chip. A rabbit polyclonal antiserum raised against bovine κ-casein was used for the development of a competitive immunoassay realized in three steps, including a reaction with the antiserum, a biotinylated anti-rabbit IgG antibody, and streptavidin. The implementation of this assay configuration significantly reduced the non-specific signal due to the cheese matrix, and allowed completion of the assay in ∼9 min. After optimization of all assay conditions, bovine cheese could be quantified in mozzarella or feta at concentrations as low as 0.5 and 0.25% (w/w), respectively; both quantification limits were below the maximum allowable content of bovine milk in mozzarella and feta (1% w/w) according to the EU regulations. Equally important, the assays were reproducible with intra- and inter-assay coefficients of variation <10%, and exhibited a wide linear dynamic range that extended up to 50 and 25% (w/w) for mozzarella and feta, respectively. Taking into account its performance, the proposed immunosensor may be transformed to a new tool against fraudulent activities in the dairy industry.


Asunto(s)
Técnicas Biosensibles/métodos , Queso/análisis , Inmunoensayo/métodos , Leche , Fotones , Silicio/química , Animales , Bovinos , Contaminación de Alimentos , Calidad de los Alimentos , Factores de Tiempo
4.
Biosensors (Basel) ; 10(11)2020 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-33113758

RESUMEN

Deoxynivalenol (DON) is a mycotoxin produced by certain Fusarium species and found in a high percentage of wheat and maize grains cultured worldwide. Although not so toxic as other mycotoxins, it exhibits both chronic and acute toxicity, and therefore methods for its fast and accurate on-site determination are highly desirable. In the current work, we employ an optical immunosensor based on White Light Reflectance Spectroscopy (WLRS) for the fast and sensitive immunochemical label-free determination of DON in wheat and maize samples. The assay is completed in 12 min and has a quantification limit of 2.5 ng/mL in buffer corresponding to 125 µg/kg in whole grain which is lower than the maximum allowable concentrations set by the regulatory authorities for grains intended for human consumption. Several extraction protocols have been compared, and the highest recovery (>90%) was achieved employing distilled water. In addition, identical calibration curves were received in buffer and wheat/maize extraction matrix providing the ability to analyze the grain samples using calibrators in buffer. Recoveries of DON from spiked wheat and maize grain samples ranged from 92.0(±4.0) to 105(±4.0)%. The analytical performance of the WLRS immunosensor, combined with the short analysis time and instrument portability, supports its potential for on-site determinations.


Asunto(s)
Grano Comestible/microbiología , Micotoxinas/análisis , Tricotecenos/análisis , Análisis de los Alimentos , Microbiología de Alimentos , Fusarium , Humanos , Sistema Inmunológico , Análisis Espectral , Triticum
5.
Biogerontology ; 21(6): 695-708, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32533368

RESUMEN

Senescent fibroblasts are characterized by their inability to proliferate and by a pro-inflammatory and catabolic secretory phenotype, which contributes to age-related pathologies. Furthermore, senescent fibroblasts when cultured under classical conditions in vitro are also characterized by striking morphological changes, i.e. they lose the youthful spindle-like appearance and become enlarged and flattened, while their nuclei from elliptical become oversized and highly lobulated. Knowing the strong relation between cell shape and function, we cultured human senescent fibroblasts on photolithographed Si/poly(vinyl alcohol) (PVA) micro-patterned surfaces in order to restore the classical spindle-like geometry and subsequently to investigate whether the changes in senescent cells' morphology are the cause of their functional alterations. Interestingly, under these conditions senescent cells' nuclei do not revert to the classical elliptical phenotype. Furthermore, enforced spindle-shaped senescent cells retained their deteriorated proliferative ability, and maintained the increased gene expression of the cell cycle inhibitors p16Ink4a and p21Waf1. In addition, Si/PVA-patterned-grown senescent fibroblasts preserved their senescence-associated phenotype, as evidenced by the overexpression of inflammatory and catabolic genes such as IL6, IL8, ICAM1 and MMP1 and MMP9 respectively, which was further manifested by an intense downregulation of fibroblasts' most abundant extracellular matrix component Col1A, compared to their young counterparts. These data indicate that the restoration of the spindle-like shape in senescent human fibroblasts is not able to directly alter major functional traits and restore the youthful phenotype.


Asunto(s)
Forma de la Célula , Senescencia Celular , Fibroblastos , Células Cultivadas , Colágeno Tipo I , Cadena alfa 1 del Colágeno Tipo I , Inhibidor p16 de la Quinasa Dependiente de Ciclina , Inhibidor p21 de las Quinasas Dependientes de la Ciclina , Matriz Extracelular , Fibroblastos/citología , Humanos , Piel
6.
Biomed Microdevices ; 22(3): 44, 2020 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-32572586

RESUMEN

We present a disposable polymeric microfluidic device capable of reversibly binding and purifying Salmonella DNA through solid phase extraction (SPE). The microfluidic channels are first oxygen plasma treated and simultaneously micro-nanotextured, and then functionalized with amine groups via modification with L-histidine or poly-L-histidine. L-Histidine and poly-L-histidine bind on the plasma treated chip surface, and are not detached when rinsing with DNA purification protocol buffers. A pH-dependent protocol is applied on-chip to purify Salmonella DNA, which is first bound on the protonated amines at a pH (5.0) lower than their pKa of surface amine-groups which is 6.0 and then released at a pH higher than the pKa value (10.5). It was found that modification with poly-L-histidine resulted in higher surface density of amine groups onto microfluidic channel. Using the chip modified with poly-L-histidine, high recovery efficiency of at least 550 ng of isolated Salmonella DNA as well as DNA purification from Salmonella cell lysates corresponding to less than 5000 cells or 0.026 ng of Salmonella DNA was achieved. The protocol developed does not require ethanol or chaotropic solutions typically used in DNA purification, which are known inhibitors for downstream operations such as polymerase chain reactions (PCR) and which can also attack some polymeric microfluidic materials. Therefore, the microfluidic device and the related protocol hold promise for facile incorporation in microfluidics and Lab-on-a-chip (LOC) platforms for pathogen detection or in general for DNA purification.


Asunto(s)
ADN Bacteriano/aislamiento & purificación , Histidina/química , Dispositivos Laboratorio en un Chip , Extracción en Fase Sólida/instrumentación , Aminas/química , ADN Bacteriano/química , Salmonella/citología , Salmonella/genética
7.
Talanta ; 214: 120854, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32278411

RESUMEN

An optical immunosensor based on White Light Reflectance Spectroscopy is described for the determination of the herbicide glyphosate in drinking water samples. The biosensor allows for the label-free real-time monitoring of biomolecular interactions taking place onto a SiO2/Si chip by transforming the shift in the reflected interference spectrum caused by the immunoreaction to effective biomolecular adlayer thickness. Glyphosate determination is accomplished by functionalizing the chip with a protein conjugate of the herbicide followed by a competitive immunoassay format. Prior to the assay, glyphosate derivatization in the calibrators and/or the samples was performed through reaction with succinic anhydride. Under the optimized assay protocol, a detection limit of 10 pg mL-1 was achieved. Recovery values ranging from 90.0 to 110% were determined in spiked bottled and tap water samples, demonstrating the accuracy of the method. In addition, the sensor could be regenerated and re-used for at least 14 times without statistically significant effect on the assay sensitivity and accuracy. The excellent analytical performance and short analysis time (approx. 25 min), combined with the small sensor size, should be helpful for the fast on-site determination of glyphosate in drinking water samples.

8.
Biosens Bioelectron ; 153: 112035, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31989941

RESUMEN

Biosensing through White Light Reflectance Spectroscopy (WLRS) is based on monitoring the shift of interference spectrum due to the binding reactions occurring on top of a thin SiO2 layer deposited on a silicon chip. Multi-analyte determinations were possible through scanning of a single sensor chip on which multiple bioreactive areas have been created. Nonetheless, the implementation of moving parts increased the instrumentation size and complexity and limited the potential for on-site determinations. Thus, in this work, a new approach, which is based on patterning the sensor surface to create areas with different SiO2 thickness, is developed and evaluated for multi-analyte determinations with the WLRS set-up. The areas of different thickness can be interrogated by a single reflection probe placed on a fixed position over the chip and the reflection spectrum recorded is de-convoluted to the spectra corresponding to each area allowing the simultaneous monitoring of the bioreactions taking place at each one of them. The combination of different areas thickness was optimized using chips with two areas for single analyte assays. The optimum chips were then used for the simultaneous determination of two mycotoxins, aflatoxin B1 and fumonisin B1. A competitive immunoassay format was followed employing immobilization of mycotoxin-protein conjugates onto the SiO2 of different thickness. It was found that the dual-analyte assays had identical analytical characteristics with the respective single-analyte ones. The detection limits achieved were 0.05 ng/mL for aflatoxin B1 and 1.0 ng/mL for fumonisin B1, with dynamic ranges extending up to 5.0 and 50 ng/mL, respectively. The sensor was also evaluated for the determination of the two mycotoxins in whole grain samples (wheat and maize). The extraction protocol was optimized and recoveries ranging from 85 to 115% have been determined. Due to lack of moving parts, the novel multi-analyte format is expected to considerably facilitate the built-up of a portable device for determination of analytes at the point-of-need.


Asunto(s)
Contaminación de Alimentos/análisis , Micotoxinas/análisis , Dióxido de Silicio/química , Silicio/química , Aflatoxina B1/análisis , Animales , Anticuerpos Monoclonales/química , Técnicas Biosensibles , Diseño de Equipo , Fumonisinas/análisis , Inmunoensayo , Luz , Límite de Detección , Ratones , Espectrofotometría , Propiedades de Superficie , Triticum/química , Zea mays/química
9.
Biomed Mater ; 14(1): 014101, 2018 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-30362459

RESUMEN

In this work, silicon substrates with poly(vinyl alcohol) (PVA) patterns created by a simple, low-cost and high-fidelity photolithographic procedure were evaluated with respect to cell adhesion and alignment, viability, metabolic activity, proliferation and cell cycle progression using the human glioblastoma cell-line U87MG and human skin fibroblasts. In addition, rat adrenal pheochromocytoma cells (PC-12) were employed to evaluate a modified photolithographic protocol appropriate for adhesion of cells requiring extracellular matrix components to adhere on the surface and to demonstrate that the proposed patterned substrates could provide unhindered cell differentiation. Regarding U87MG cells and skin fibroblasts, it was found that as the stripes width increased from 10 to 50 µm, the percentage of cells attached to Si versus the total area (Si + PVA) increased from 78% and 72% to 98.5% and 94.5% (p < 0.05), for U87MG cells and skin fibroblasts, respectively, with optimum cell alignment (≥95% of adherent cells with fidelity between 0.90 and 1.0; p < 0.05) for stripes width ranging between 20 and 22.5 µm. Concerning the viability, metabolic activity and proliferation of adherent cells, no statistically significant differences were observed compared to cells cultured onto non-patterned surfaces. Regarding PC-12 cells, a modification of the patterning procedure was followed involving coating of the substrate with type IV collagen prior to the photolithographic procedure, since they could not adhere on plain Si substrates. It was found that PC-12 cells adhere selectively (>95%) to collagen-coated Si stripes when the pattern width was equal to or wider than 10 µm. Following treatment with nerve growth factor, approximately 80% (p < 0.05) of the adherent cells differentiated to neuron-like cells extending neurites exclusively within the pattern. Given that the proposed patterning procedure allows highly selective cell adhesion without affecting cell proliferation, metabolic activity, and differentiation it could serve as a useful tool in various fields including tissue engineering, cell-based sensors and analytical microsystems.


Asunto(s)
Adhesión Celular , Técnicas de Cultivo de Célula , Alcohol Polivinílico/química , Silicio/química , Animales , Ciclo Celular , Diferenciación Celular , Línea Celular Tumoral , Proliferación Celular , Colágeno/química , Medios de Cultivo , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Humanos , Ensayo de Materiales , Neuritas/metabolismo , Células PC12 , Ratas , Piel/citología , Piel/efectos de los fármacos , Propiedades de Superficie , Ingeniería de Tejidos/métodos
10.
J Hazard Mater ; 359: 67-75, 2018 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-30014916

RESUMEN

An optical immunosensor based on White Light Reflectance Spectroscopy for the simultaneous determination of the herbicides atrazine and paraquat in drinking water samples is demonstrated. The biosensor allows for the label-free real-time monitoring of biomolecular interactions taking place onto a SiO2/Si chip by transforming the shift in the reflected interference spectrum due to reaction to effective biomolecular layer thickness. Dual-analyte determination is accomplished by functionalizing spatially distinct areas of the chip with protein conjugates of the two herbicides and scanning the surface with an optical reflection probe. A competitive immunoassay format was adopted, followed by reaction with secondary antibodies for signal enhancement. The sensor was highly sensitive with detection limits of 40 and 50 pg/mL for paraquat and atrazine, respectively, and the assay duration was 12 min. Recovery values ranging from 90.0 to 110% were determined for the two pesticides in spiked bottled and tap water samples, demonstrating the sensor accuracy. In addition, the sensor could be regenerated and re-used at least 20 times without significant effect on the assay characteristics. Its excellent analytical performance and short analysis time combined with the small sensor size should be helpful for fast on-site determinations of these analytes.


Asunto(s)
Atrazina/análisis , Técnicas Biosensibles , Herbicidas/análisis , Paraquat/análisis , Contaminantes Químicos del Agua/análisis , Anticuerpos/inmunología , Atrazina/inmunología , Herbicidas/inmunología , Inmunoensayo , Luz , Paraquat/inmunología , Albúmina Sérica Bovina/inmunología , Análisis Espectral/métodos , Contaminantes Químicos del Agua/inmunología
11.
Anal Chem ; 90(15): 9559-9567, 2018 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-29999303

RESUMEN

A silicon-based miniaturized sensor chip combined with an advanced microfluidic module for the simultaneous, label-free immunochemical determination of four allergens, bovine milk protein, peanut protein, soy protein, and gliadin, is presented. The sensor chip consists of an array of 10 broad-band Mach-Zehnder interferometers (BB-MZIs) monolithically integrated on silicon, along with their respective broad-band light sources. The BB-MZIs were biofunctionalized with the targeted allergens and their responses during immunoreaction were monitored by multiplexing their transmission spectra through an external miniaturized spectrometer. The assay is performed by running mixtures of calibrators or samples with the antibodies against the four allergens followed by an antispecies specific antibodies solution. Employing a fluidic module of nearly one-dimensional geometry, that provided for uniform delivery of the reagents, CV values <6% were achieved for the responses of the 10 BB-MZIs, allowing for reliable multianalyte determinations. The analysis is completed in 6.5 min, and the detection limits were 0.04 µg/mL for bovine k-casein, 1.0 µg/mL for peanut protein, 0.80 µg/mL for soy protein, and 0.10 µg/mL for gliadin. The assays were accurate (recoveries 88-118%) and repeatable (intra- and interassay CVs <7% for all four allergens). Finally, the sensor was evaluated by analyzing samples from a cleaning in place system (CIP) of a dairy industry and the results obtained were in good agreement with those received by the respective ELISAs. The analytical characteristics of the sensor combined with the short analysis time and the small chip size make the proposed system an ideal tool for on-site multianalyte determinations.


Asunto(s)
Alérgenos/análisis , Técnicas Biosensibles/instrumentación , Interferometría/instrumentación , Silicio/química , Animales , Arachis/química , Técnicas Biosensibles/economía , Caseínas/análisis , Bovinos , Análisis de los Alimentos/economía , Análisis de los Alimentos/instrumentación , Gliadina/análisis , Interferometría/economía , Dispositivos Laboratorio en un Chip/economía , Límite de Detección , Proteínas de Vegetales Comestibles/análisis , Proteínas de Soja/análisis , Factores de Tiempo
12.
J Hazard Mater ; 359: 445-453, 2018 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-30059886

RESUMEN

A label-free optical biosensor for the fast simultaneous determination of three mycotoxins, aflatoxin B1 (AFB1), fumonisin B1 (FB1) and deoxynivalenol (DON), in beer samples is presented. The biosensor is based on an array of ten Mach-Zehnder interferometers (MZIs) monolithically integrated along with their respective broad-band silicon light sources onto a single chip. Multi-analyte determination is accomplished by functionalizing the sensing arms of individual MZIs with mycotoxin-protein conjugates. Assay is performed by pumping over the chip mixtures of calibrators or samples with a mixture of specific monoclonal antibodies, followed by reaction with a secondary anti-mouse IgG antibody. Reactions are monitored in real-time by continuously recording the MZI output spectra, which are then subjected to Discrete Fourier Transform to convert spectrum shifts to phase shifts. The detection limits achieved for AFB1, FB1 and DON were 0.8, 5.6 and 24 ng/ml, respectively, while the assay duration was 12 min. Recovery values ranging from 85 to 115% were determined in beer samples spiked with known concentrations of the three mycotoxins. In addition, beers of different types and origin were analysed with the biosensor developed and the results were compared with those provided by established laboratory methods, further supporting the accuracy of the proposed device.


Asunto(s)
Aflatoxina B1/análisis , Cerveza/análisis , Contaminación de Alimentos/análisis , Fumonisinas/análisis , Tricotecenos/análisis , Aflatoxina B1/inmunología , Anticuerpos Monoclonales/inmunología , Técnicas Biosensibles , Fumonisinas/inmunología , Inmunoglobulina G/inmunología , Tricotecenos/inmunología
13.
Methods Mol Biol ; 1771: 27-40, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29633202

RESUMEN

Plasma micro-nanotexturing is a generic technology for topographical and chemical modification of surfaces and their implementation in microfluidics and microarrays. Nanotextured surfaces with desirable chemical functionality (and wetting behavior) have shown excellent biomolecule immobilization and cell adhesion. Specifically, nanotextured hydrophilic areas show (a) strong binding of biomolecules and (b) strong adhesion of cells, while nanotextured superhydrophobic areas show null adsorption of (a) proteins and (b) cells. Here we describe the protocols for (a) biomolecule adsorption control on nanotextured surfaces for microarray fabrication and (b) cell adhesion on such surfaces. 3D plasma nanotextured® substrates are commercialized through Nanoplasmas private company, a spin-off of the National Centre for Scientific Research Demokritos.


Asunto(s)
Nanotecnología , Análisis de Matrices Tisulares/métodos , Animales , Inmunoensayo/métodos , Ratones , Técnicas de Diagnóstico Molecular , Reproducibilidad de los Resultados , Análisis de Matrices Tisulares/normas
14.
Colloids Surf B Biointerfaces ; 165: 270-277, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29501021

RESUMEN

Glass slides coated with a poly(methyl methacrylate) layer and plasma micro-nanotextured to acquire 3D topography (referred as 3D micro-nanotextured slides) were evaluated as substrates for biomolecule microarrays. Their performance is compared with that of epoxy-coated glass slides. We found that the proposed three-dimensional (3D) slides offered significant improvements in terms of spot intensity, homogeneity, and reproducibility. In particular, they provided higher spot intensity, by a factor of at least 1.5, and significantly improved spot homogeneity when compared to the epoxy-silane coated ones (intra-spot and between spot coefficients of variation ranging between 5 and 15% for the 3D micro-nanotextured slides and between 25 and 85% for the epoxy-silane coated ones). The latter was to a great extent the result of a strong "coffee-ring" effect observed for the spots created on the epoxy-coated slides; a phenomenon that was severely reduced in the 3D micro-nanotextured slides. The 3D micro-nanotextured slides offered in addition higher signal to noise ratio values over a wide range of protein probe concentrations and shelf-life over one year without requirement for specific storage conditions. Finally, the protocols employed for protein probe immobilization were extremely simple.


Asunto(s)
Resinas Epoxi/química , Nanoestructuras/química , Gases em Plasma/química , Polimetil Metacrilato/química , Análisis por Matrices de Proteínas/métodos , Silanos/química , Proteína C-Reactiva/análisis , Vidrio/química , Humanos , Inmunoglobulina G/análisis , Lipopolisacáridos/análisis , Lipopolisacáridos/metabolismo , Análisis por Matrices de Proteínas/instrumentación , Salmonella/genética , Relación Señal-Ruido , Propiedades de Superficie
15.
Anal Chem ; 90(2): 1092-1097, 2018 01 16.
Artículo en Inglés | MEDLINE | ID: mdl-29251914

RESUMEN

This work reports a microfabricated electrochemical paper-based analytical device (ePAD) for the voltammetric determination of DNA. The device is patterned by wax-printing on paper and features a circular assay zone connected to an inlet zone and a sink via grooved microfluidic channels for accelerated flow rate. An electrochemical cell with integrated electrodes is formed on the reverse side of the paper by sputtering of thin metal films (Sn, Pt and Ag as the working, counter and reference electrode, respectively). Proof-of-principle of the ePAD for biosensing is demonstrated for a DNA assay involving attachment of capture DNA, hybridization with biotinylated target oligonucleotide and labeling with streptavidin-conjugated CdSe/ZnS quantum dots (QDs). After the acidic dissolution of the QDs, the released Cd(II) is quantified by anodic stripping voltammetry (ASV) at the Sn-film working electrode. Thanks to the synergistic effects of QDs amplification, the inherent sensitivity of ASV and the excellent detection capabilities of the Sn-film working electrode for Cd(II), the target DNA can be detected at levels as low as 0.11 pmol L-1 using sample volumes as low as 1 µL. The developed microfluidic ePAD costs only 0.11$ and presents favorable fabrication and operational features that make it an excellent candidate biosensor for simple and ultrasensitive point-of-need testing.


Asunto(s)
ADN/análisis , Dispositivos Laboratorio en un Chip , Hibridación de Ácido Nucleico , Papel , Puntos Cuánticos/química , Técnicas Biosensibles/instrumentación , Electrodos , Diseño de Equipo , Estreptavidina/química
16.
Talanta ; 165: 458-465, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28153283

RESUMEN

An immunosensor for fast and accurate determination of C-reactive protein (CRP) in human serum samples based on an array of all-silicon broad-band Mach-Zehnder interferometers (BB-MZIs) is demonstrated. The detection was based on monitoring the spectral shifts during the binding of CRP on the antibody molecules that have been immobilized on the sensing arms of the BB-MZIs. By employing the reaction rate as the analytical signal the assay time was compressed to few minutes. The detection limit was 2.1ng/mL, the quantification limit was 4.2ng/mL and the linear dynamic range extended up to 100ng/mL. The measurements performed in human serum samples with the developed immunosensor were characterized by high repeatability and accuracy as it was demonstrated by dilution linearity and recovery experiments. In addition, the concentration values determined were in excellent agreement with those determined for the same samples by a standard clinical laboratory method. The compact size of the chip makes the proposed immunosensor attractive for incorporation into miniaturized devices for the determination of clinical analytes at the point-of-need.


Asunto(s)
Técnicas Biosensibles/métodos , Proteína C-Reactiva/análisis , Diseño de Equipo , Interferometría/instrumentación , Interferometría/métodos , Silicio/química , Humanos , Límite de Detección
17.
J Hazard Mater ; 323(Pt A): 75-83, 2017 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-26988901

RESUMEN

An optical biosensor for label-free detection of ochratoxin A (OTA) in beer samples is presented. The biosensor consists of an array of ten Mach-Zehnder interferometers (MZIs) monolithically integrated along with their respective broad-band silicon light sources on the same Si chip (37mm2). The chip was transformed to biosensor by functionalizing the MZIs sensing arms with an OTA-ovalbumin conjugate. OTA determination was performed by pumping over the chip mixtures of calibrators or samples with anti-OTA antibody following a competitive immunoassay format. An external miniaturized spectrometer was employed to continuously record the transmission spectra of each interferometer. Spectral shifts obtained due to immunoreaction were transformed to phase shifts through Discrete Fourier Transform. The assay had a detection limit of 2.0ng/ml and a dynamic range 4.0-100ng/ml in beer samples, recoveries ranging from 90.6 to 116%, and intra- and inter-assay coefficients of variation of 9% and 14%, respectively. The results obtained with the sensor using OTA-spiked beer samples spiked were in good agreement with those obtained by an ELISA developed using the same antibody. The good analytical performance of the biosensor and the small size of the proposed chip provide for the development of a portable instrument for point-of-need determinations.


Asunto(s)
Cerveza/análisis , Técnicas Biosensibles , Contaminación de Alimentos/análisis , Interferometría , Ocratoxinas/análisis , Silicio/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Inmunoensayo , Interferometría/instrumentación , Interferometría/métodos , Límite de Detección , Fenómenos Ópticos
18.
Nanoscale Res Lett ; 10: 210, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25991914

RESUMEN

Photodynamic therapy (PDT) involves the action of photons on photosensitive molecules, where atomic oxygen or OH(-) molecular species are locally released on pathogenic human cells, which are mainly carcinogenic, thus causing cell necrosis. The efficacy of PDT depends on the local nanothermodynamic conditions near the cell/nanodrug system that control both the level of intracellular translocation of nanoparticles in the pathogenic cell and their agglomeration on the cell membrane. Dendrimers are considered one of the most effective and promising drug carriers because of their relatively low toxicity and negligible activation of complementary reactions. Polyamidoamine (PAMAM) dendrite delivery of PDT agents has been investigated in the last few years for tumour selectivity, retention, pharmacokinetics and water solubility. Nevertheless, their use as drug carriers of photosensitizing molecules in PDT for cardiovascular disease, targeting the selective necrosis of macrophage cells responsible for atheromatous plaque growth, has never been investigated. Furthermore, the level of aggregation, translocation and nanodrug delivery efficacy of PAMAM dendrimers or PAMAM/zinc phthalocyanine (ZnPc) conjugates on human atheromatous tissue and endothelial cells is still unknown. In this work, the aggregation of PAMAM zero generation dendrimers (G0) acting as drug delivery carriers, as well as conjugated G0 PAMAM dendrimers with a ZnPc photosensitizer, to symptomatic and asymptomatic human carotid tissues was investigated by using atomic force microscopy (AFM). For the evaluation of the texture characteristics of the AFM images, statistical surface morphological and fractal analytical methodologies and Minkowski functionals were used. All statistical quantities showed that the deposition of nanodrug carriers on healthy tissue has an inverse impact when comparing to the deposition on atheromatous tissue with different aggregation features between G0 and G0/ZnPc nanoparticles and with considerably larger G0/ZnPc aggregations on the atheromatous plaque. The results highlight the importance of using PAMAM dendrimer carriers as a novel and promising PDT platform for atherosclerosis therapies.

19.
Anal Bioanal Chem ; 407(14): 3995-4004, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25796524

RESUMEN

The label-free detection of bovine milk in goat milk through a miniaturized optical biosensor is presented. The biosensor consists of ten planar silicon nitride waveguide Broad-Band Mach-Zehnder interferometers (BB-MZIs) monolithically integrated and self-aligned with their respective silicon LEDs on the same Si chip. The BB-MZIs were transformed to biosensing transducers by functionalizing their sensing arm with bovine k-casein. Measurements were performed by continuously recording the transmission spectra of each interferometer through an external spectrometer. The amount of bovine milk in goat milk was determined through a competitive immunoassay by passing over the sensor mixtures of anti-k-casein antibodies with the calibrators or the samples. The output spectra of each BB-MZI recorded during the reaction were subjected to Discrete Fourier Transform in order to convert the observed spectral shifts to phase shifts in the wavenumber domain. The method had a detection limit of 0.04 % (v/v) bovine milk in goat milk, dynamic range 0.1-1.0 % (v/v), recoveries 93-110 %, and intra- and inter-assay coefficients of variation less than 12 and 15 %, respectively. The proposed biosensor compared well in terms of analytical performance with a competitive ELISA developed using the same monoclonal antibodies. Nevertheless, the duration of the biosensor assay was 10 min whereas the ELISA required 2 h. Thus, the fast and sensitive determinations along with the small size of the sensor make it ideal for incorporation into portable devices for assessment of goat or ewe's milk adulteration with bovine milk at the point-of-need.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Contaminación de Alimentos , Leche/química , Animales , Anticuerpos , Fenómenos Electromagnéticos , Cabras , Miniaturización , Fenómenos Ópticos , Factores de Tiempo
20.
Adv Exp Med Biol ; 822: 213-20, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25416996

RESUMEN

The efficiency of penetration of nanodrugs through cell membranes imposes further complexity due to nanothermodynamic and entropic potentials at interfaces. Action of nanodrugs is effective after cell membrane penetration. Contrary to diffusion of water diluted common molecular drugs, nanosize imposes an increasing transport complexity at boundaries and interfaces (e.g., cell membrane). Indeed, tiny dimensional systems brought the concept of "nanothermodynamic potential," which is proportional to the number of nanoentities in a macroscopic system, from either the presence of surface and edge effects at the boundaries of nanoentities or the restriction of the translational and rotational degrees of freedom of molecules within them. The core element of nanothermodynamic theory is based on the assumption that the contribution of a nanosize ensemble to the free energy of a macroscopic system has its origin at the excess interaction energy between the nanostructured entities. As the size of a system is increasing, the contribution of the nanothermodynamic potential to the free energy of the system becomes negligible. Furthermore, concentration gradients at boundaries, morphological distribution of nanoentities, and restriction of the translational motion from trapping sites are the source of strong entropic potentials at the interfaces. It is evident therefore that nanothermodynamic and entropic potentials either prevent or allow enhanced concentration very close to interfaces and thus strongly modulate nanoparticle penetration within the intracellular region. In this work, it is shown that nano-sized polynuclear iron (III)-hydroxide in sucrose nanoparticles have a nonuniform concentration around the cell membrane of macrophages in vivo, compared to uniform concentration at hydrophobic prototype surfaces. The difference is attributed to the presence of entropic and nanothermodynamic potentials at interfaces.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Nanoestructuras/administración & dosificación , Preparaciones Farmacéuticas/administración & dosificación , Termodinámica , Algoritmos , Línea Celular Tumoral , Compuestos Férricos/administración & dosificación , Compuestos Férricos/química , Compuestos Férricos/farmacocinética , Análisis de Fourier , Humanos , Macrófagos/metabolismo , Microscopía de Fuerza Atómica , Modelos Biológicos , Nanopartículas/administración & dosificación , Nanopartículas/química , Nanoestructuras/química , Tamaño de la Partícula , Preparaciones Farmacéuticas/química , Reproducibilidad de los Resultados , Sacarosa/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...