Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Fluoresc ; 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38294633

RESUMEN

Apoptosis is the programmed cell death pathway that is critical for maintaining homeostasis, in which cancer cells can evade to ensure survival. For pharmaceutical drug discovery, it is important to characterize and compare different cancer therapeutics (i.e., small molecules, antibody drugs, cell therapies) that can initiate the process of apoptosis, enabling the identification of potential therapeutic candidates. In this work, we developed and demonstrated a multiplex detection method for monitoring apoptosis and necrosis with Annexin V, Caspase-3, and Propidium Iodide (PI) using the Cellaca® PLX Image Cytometer (Revvity Health Sciences, Inc., Lawrence, MA). First, apoptosis was induced in Jurkat and K562 cell lines with staurosporine over the course of 24 h, where apoptosis and necrosis were assessed at 0, 1, 1.5, 2, 4, 20, and 24 h timepoints. Samples were stained with Hoechst 33342 (total dye), Annexin V-APC (early-stage apoptosis), Caspase-3 488 (late-stage apoptosis), and PI (necrosis) at each timepoint and evaluated using image cytometry. Results showed that apoptotic factors and cascades were successfully detected along the pathway from early- to late-stage apoptosis, and ultimately necrosis. A clear trend was observed analyzing apoptotic and necrotic populations during the first 1.5 h, showing differences of up to ~15% in single Annexin V+ and Caspase-3+ populations in treated Jurkat cells, however, a significant increase in double positive apoptotic/necrotic cells for Annexin V+PI+ and Capase-3+PI+ was not observed until 20 h. Upon further analysis between apoptotic populations only, Annexin V+ only populations were higher than Caspase-3+ only populations by up to ~20% between 0 and 1.5 h. Conversely, K562 cells did not exhibit a notable change in apoptotic and necrotic populations due to low sensitivity to staurosporine. The proposed image cytometric detection method may provide an effective and efficient tool for rapid and reliable simultaneous detection of early- late-stage apoptosis, and necrosis. Therefore, allowing researchers to better characterize and screen potential cancer therapeutic drug candidates for their treatment efficacy in a higher throughput manner.

2.
Anal Biochem ; 685: 115389, 2024 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-37951455

RESUMEN

Cell and gene therapy is a fast-growing field for cancer therapeutics requiring reliable instrumentation and technologies. Key parameters essential for satisfying Chemistry Manufacturing and Controls criteria standards are routinely performed using flow cytometry. Recently, image cytometry was developed for cell characterization and cell-based assays but had not yet demonstrated sufficient sensitivity for surface marker detection. We developed the Cellaca® PLX image cytometry system and the respective methodologies required for immunophenotyping, GFP and RFP transfection/transduction efficiencies, and cell health analyses for routine cell characterization. All samples tested were compared directly to results from the CytoFLEX flow cytometer. PBMCs were stained with T-cell surface markers for immunophenotyping, and results show highly comparable CD3, CD4, and CD8 populations (within 5 %). GFP- or RFP-expressing cell lines were analyzed for transfection/transduction efficiencies, and the percentage positive cells and respective viabilities were equivalent on both systems. Staurosporine-treated Jurkat cells were stained for apoptotic markers, where annexin V and caspase-3 positive cells were within 5 % comparing both instruments. The proposed system may provide a complementary tool for performing routine cell-based experiments with improved efficiency and sensitivity compared to prior image cytometers, which may be significantly valuable to the cell and gene therapy field.


Asunto(s)
Apoptosis , Humanos , Inmunofenotipificación , Transfección , Línea Celular , Células Jurkat , Citometría de Flujo/métodos
3.
J Fluoresc ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37736833

RESUMEN

Cellular therapy development and manufacturing has focused on providing novel therapeutic cell-based products for various diseases. The International Organization for Standardization (ISO) has provided guidance on critical quality attributes (CQAs) that shall be considered when testing and releasing cellular therapeutic products. Cell count and viability measurements are two of the CQAs that are determined during development, manufacturing, testing, and product release. The ISO Cell Counting Standard Part 1 and 2 addressed the needs for improving the quality of cell counting results. However, there is currently no guidance on the qualification and selection of a fit-for-purpose cell viability detection method. In this work, we present strategies for the characterization and comparison of AO/PI and AO/DAPI staining methods using the heat-killed (HK) and low temperature/nutrient-deprived (LT/ND) cell death models to evaluate the comparability of cell viability measurements and identify potential causes of differences. We compared the AO/PI and AO/DAPI staining methods using HK and LT/ND-generated dead cells, investigated the staining time effects on cell viability measurements, and determined their viability linearity with different mixtures of live and dead cells. Furthermore, we validated AO/PI and AO/DAPI cell viability measurement with a long-term cell proliferation assay. Finally, we demonstrate a practical example of cell viability measurement comparison using AO/PI and AO/DAPI on antibiotic-selected transduced Jurkat and THP-1 cells to select a fit-for-purpose method for functional genomics screening. The proposed strategies may potentially enable scientists to properly characterize, compare, and select cell viability detection methods that are critical for cellular therapeutic product development and manufacturing.

4.
J Immunol Methods ; 521: 113538, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37597726

RESUMEN

In cellular therapies chimeric antigen receptor (CAR) T or NK cells undergo phenotypic analysis at multiple stages during discovery and development of novel therapies. Patient samples are routinely analyzed via flow cytometry for population identification and distribution of CD3, CD4, and CD8 positive T cells. As an alternative or orthogonal method, image cytometry systems have been used to perform simple cell-based assays in lieu of flow cytometry. Recently, a new image cytometry system, the Cellaca® PLX (Revvity Health Sciences, Inc., Lawrence, MA), was developed for high-throughput cell counting and viability, immunophenotyping, transfection/transduction efficiency, and cell health assays. This novel instrument allows investigators to quickly assess several critical quality attributes (CQAs) such as cell identity, viability, and other relevant biological functions recommended by the International Organization for Standardization using the ISO Cell Characterization documents focused on cellular therapeutic products. In this work, we demonstrate a rapid and high-throughput image cytometry detection method for cellular immunophenotyping and viability using the Cellaca PLX system for samples throughout the cellular therapy workflow. Freshly isolated peripheral blood mononuclear cells (PBMCs) underwent red blood cell (RBC) lysis and CD3 enrichment. Samples were then subsequently stained with Hoechst/CD3/CD4/CD8 or Hoechst/CD3/CD8/RubyDead Dye surface marker kits and measured on the Cellaca PLX and three different flow cytometers for side-by-side comparison and assay validation. Acquisition and analysis of cell viability and cell populations was shown to be faster and more efficient process compared to flow while achieving highly comparable results between the two technology platforms. This data shows that the Cellaca PLX Image Cytometer may provide a rapid alternative or orthogonal method for PBMC immunophenotyping experiments, as well as potentially streamline the workflow to quickly move precious patient samples downstream within the development processes.


Asunto(s)
Linfocitos T CD8-positivos , Leucocitos Mononucleares , Humanos , Inmunofenotipificación , Células Asesinas Naturales , Bioensayo
6.
Sr Care Pharm ; 34(7): 419-431, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31383052

RESUMEN

OBJECTIVE: To review clinical studies evaluating melatonin doses and their effects on sleep in adults 65 years of age and older. DATA SOURCES: The MEDLINE databases were searched (1946 to October 10, 2018) using the following Medical Subject Heading terms: melatonin and: sleep initiation and maintenance disorders, dyssomnia, sleep wake disorders, insomnia, sleep disorders intrinsic, and sleep disorders circadian rhythm. Sources were limited to English and human data. STUDY SELECTION/DATA EXTRACTION: An initial search resulted in 144 publications, with 25 included in this review. Studies were selected for full review based on design, mean age of participants, use of exogenous melatonin, and reports on any sleep-related outcome. DATA SYNTHESIS: Because of the side effect profiles of most prescription and nonprescription sleep aids, safe and effective alternative therapies are necessary. Based on the current literature, no dose-related response to sleep improvement has been identified for melatonin in older adults. Variations in melatonin formulation and dosages, as well as available tools to measure sleep outcomes, make it challenging to compare studies. CONCLUSIONS: This review evaluated a variety of melatonin doses, 0.5 mg to 10 mg, and their effects on sleep in older adults. The results varied, with some studies finding no difference in sleep outcomes when compared with placebo, while other studies found statistically significant improvements in sleep outcomes. Doses of melatonin between 1 mg and 6 mg appear to be effective for improving sleep in older adults; however, further studies are needed to find the optimal minimum effective dose.


Asunto(s)
Melatonina/administración & dosificación , Trastornos del Sueño-Vigilia , Ritmo Circadiano , Humanos , Sueño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...