Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 38(7S): S124-S130, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36791889

RESUMEN

BACKGROUND: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. METHODS: A total of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. RESULTS: The overall dislocation rate was 0.98%. Use of femoral head sizes ≥ 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P = .279). Also, no dislocations occurred in patients who had dual-mobility bearings or ≥ 40-millimeter femoral heads (P = .007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P = .013). Thirteen of 14 dislocations were in women (P = .005). CONCLUSION: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. LEVEL OF EVIDENCE: IV-consecutive case series; no control group.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Femenino , Masculino , Artroplastia de Reemplazo de Cadera/efectos adversos , Cabeza Femoral/cirugía , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Luxaciones Articulares/cirugía , Polietileno , Reoperación , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Luxación de la Cadera/prevención & control , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...