Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Echocardiography ; 41(6): e15848, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38814015

RESUMEN

PURPOSE: Assessment of aortic stenosis (AS) is based on aortic valve (AV) gradients and calculation of aortic valve area (AVA). These parameters are influenced by flow and dependent on geometric assumptions. The dimensionless index (DI), the ratio of the LVOT time-velocity integral to that of the AV jet, is simple to perform, and is less susceptible to error but has only been examined in small selected groups of AS patients. The objective of this study was to assess the DI and prognosis in a large cohort. METHODS: All subjects who underwent echocardiography with an assessment of the AV that included DI were included. Association between AV parameters including mean gradient, AVA, DI and AV resistance and mortality and cardiovascular hospitalizations was examined. RESULTS: A total of 9393 patients (mean age 71 ± 16 years; 53% male) were included. 731 (7.7%) patients had DI less than .25. Increasing age and a diagnosis of heart failure were significantly associated with lower DI. Subjects with low DI had significantly lower ventricular function, a higher incidence of mitral and tricuspid regurgitation, worse diastolic function and more elevated pulmonary pressures. Decreasing DI was associated with significantly decreased survival and event-free survival which remained highly significant on multivariate analysis. CONCLUSIONS: In a large population of patients with AV disease, decreased DI, was associated with increased mortality and decreased event-free survival. The easily obtained DI identifies a broad range of AS subjects with worse prognosis and should be integrated into the assessment of these complex patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Masculino , Femenino , Anciano , Pronóstico , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ecocardiografía/métodos , Tasa de Supervivencia , Enfermedad de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica/complicaciones , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Estudios Retrospectivos
2.
J Cardiovasc Surg (Torino) ; 65(2): 161-168, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38332715

RESUMEN

BACKGROUND: Based on worldwide registries, approximately 50% of patients who underwent aortic valve replacement (AVR) via surgical aortic valve replacement are females. Although AVR procedures have improved greatly in recent years, differences in outcome including mortality between sexes remain. We aimed to investigate the trends in SAVR outcomes in females versus males. METHODS: Using the 2011-2017 National Inpatient Sample (NIS) database, we identified hospitalizations for patients with diagnosis of aortic stenosis during which SAVR was performed. Patients' sociodemographic and clinical characteristics, procedure complications, and mortality were analyzed. Piecewise regression analyses were performed to assess temporal trends in SAVR utilization in females versus males. Multivariable analyses were performed to identify predictors of in-hospital mortality. RESULTS: A total of 392,087 hospitalizations for SAVR across the USA were analyzed. Utilization of SAVR in both sex patients decreased significantly during the years 2011-2017. Males compared to females had significantly higher rates of hyperlipidemia, chronic renal disease, peripheral artery disease, coronary artery disease and tended to be smokers. Differences in mortality rates among sexes were observed for SAVR procedures. Women had higher in-hospital mortality with 3.7% compared to men with 2.5% (OR 1.38 [95% CI 1.33-1.43, P<0.001]). In a multivariable regression model analysis adjusted for potential confounders, women had higher mortality risk with odd ratio (OR 1.38 [95% CI 1.33-1.43], P<0.001). Women had significantly higher rates of vascular complications (5.1% compared to men with 4.6%, P=0.002). CONCLUSIONS: Utilization of SAVR showed a downward trend during the study period. Higher in-hospital mortality was recorded in females compared to males.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bases de Datos Factuales , Implantación de Prótesis de Válvulas Cardíacas , Mortalidad Hospitalaria , Humanos , Femenino , Masculino , Anciano , Mortalidad Hospitalaria/tendencias , Estados Unidos/epidemiología , Factores Sexuales , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Válvula Aórtica/cirugía , Factores de Tiempo , Persona de Mediana Edad , Anciano de 80 o más Años , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Pacientes Internos , Disparidades en el Estado de Salud , Medición de Riesgo , Disparidades en Atención de Salud/tendencias , Comorbilidad
3.
JACC Case Rep ; 29(3): 102205, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38361553

RESUMEN

A 31-year-old woman with end-stage kidney disease and with a bicuspid aortic valve presented with acute heart failure in the second trimester of pregnancy. The patient received a diagnosis of severe aortic stenosis and chose to continue the pregnancy against medical advice. Following a multidisciplinary team consultation, she underwent urgent transcatheter aortic valve replacement.

4.
Pacing Clin Electrophysiol ; 46(11): 1291-1301, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37830375

RESUMEN

BACKGROUND AND AIMS: Left bundle branch block (LBBB) is common after transcatheter aortic valve replacement (TAVR) and associated with a left or normal QRS axis. We aim to assess the QRS frontal plane axis shift changes during LBBB after TAVR and determine if the risk of procedure-related high degree atrioventricular block (AVB) is affected by QRS axis shift changes. METHODS AND RESULTS: In a retrospective single-center study of 720 consecutive patients who underwent TAVR, 141 (19.6%) with normal baseline QRS duration developed a new LBBB after TAVR and constituted the study group. Most patients (59.6%) were females and the mean age of the cohort was 81.2 ± 6 years. RESULTS: As compared with the baseline QRS axis before TAVR, the occurrence of LBBB was associated with a leftward QRS axis shift (by 40 ± 28.3°) in 73% of the study patients and a rightward (by 18.6 ± 19.4°) or no change in QRS axis in 25.6% and 1.4% of the study patients, respectively. A left QRS axis (-30°) was observed in 14.9% and 38.3% of the study patients before and after TAVR, respectively. The group of patients exhibiting a rightward or no QRS axis shift had a greater incidence of high degree AVB than the group of patients exhibiting a leftward QRS axis shift (18.4% vs. 6.8%, p = .056). CONCLUSION: Although post TAVR-LBBB is associated with a leftward QRS axis shift in most patients, a non-negligible proportion of patients (27%) exhibited a rightward or no QRS axis shift. The latter group tend to have a higher risk of developing high degree AVB.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama , Resultado del Tratamiento , Estudios Retrospectivos , Electrocardiografía/métodos , Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas , Válvula Aórtica/cirugía
5.
J Clin Med ; 12(19)2023 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-37834991

RESUMEN

Objectives: This article aims to evaluate the accuracy of the color-Doppler-based technique to evaluate residual mitral regurgitation post TEER. Background: The evaluation of residual mitral regurgitation (MR) post-mitral transcutaneous edge-to-edge repair (mitral TEER) is a critical determinant in patients' outcomes. The common methods used today, based on the integration of color flow Doppler parameters, may be misleading because of the multiple jets and high velocities created by the TEER devices. Methods: Patients undergoing TEER at Hadassah hospital were recruited between 2015 and 2019. Post-procedural MR was evaluated using the integrated qualitative approach as recommended by the guidelines. In addition, the MR volume for each patient was calculated by subtracting the forward stroke volume (calculated by multiplying the LVOT area with the velocity time integral of the LVOT systolic flow) from the total stroke volume (calculated by the biplane Simpson method of discs). We compared the two methods for concordance. Results: Overall, 112 cases were enrolled. In 55.4% of cases, the volumetric residual MR was milder than the MR severity assessed by the guidelines' recommended method. In 25.1%, the MR severity was similar in both methods. In 16.2%, the MR severity was worse when calculated using the volumetric method (pValue < 0.001, Kappameasure of agreement = 0.053). The lower residual MR degree using the volumetric approach was mostly observed in patients classified as "moderate" by the integrated approach. Conclusions: MR severity after TEER is often overestimated by the guideline-recommended integrative method when compared with a volumetric method. Alternative methods should be considered to assess the MR severity after mitral TEER.

7.
Isr Med Assoc J ; 25(8): 547-552, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37574893

RESUMEN

BACKGROUND: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance. OBJECTIVES: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR. METHODS: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients. RESULTS: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5-9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059-1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables. CONCLUSIONS: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Volúmen Plaquetario Medio , Hemorragia/etiología , Válvula Aórtica/cirugía , Factores de Riesgo
8.
BMC Cardiovasc Disord ; 23(1): 304, 2023 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-37328829

RESUMEN

BACKGROUND: Transcatheter edge to edge repair (TEER) improves prognosis in patients with functional mitral regurgitation (FMR) receiving guideline directed medical therapy (GDMT). Many patients with FMR do not receive GDMT and the utility of TEER in this population remains unclear. METHODS: We retrospectively studied patients undergoing TEER. Clinical, echocardiographic and procedural variables were recorded. GDMT was defined as use of RAAS inhibitors and MRAs unless GFR was under 30 as well as beta blockers. The primary endpoint of the study was one year mortality. RESULTS: 168 patients (mean age 71.3 ± 9.3; 66% males) with FMR who underwent TEER were included of whom 116 (69%) received GDMT at the time of TEER and 52 (31%) did not. There were no significant demographic or clinical differences between the groups. There were no significant differences in procedural success and complications between groups. One year mortality was identical in the two groups (15% vs. 15%; RR 1.06, CI 0.43-2.63, P = 0.90). CONCLUSIONS: Our findings suggest that procedural success and one year mortality following TEER was not significantly different in HFREF patients with FMR with or without GDMT. Larger, prospective studies are necessary to define the benefit of TEER in this population.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Israel , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento
9.
CMAJ ; 195(24): E833-E843, 2023 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-37336568

RESUMEN

BACKGROUND: Therapeutic options for intermediate- or high-risk pulmonary embolism (PE) include anticoagulation, systemic thrombolysis and catheter-directed thrombolysis (CDT); however, the role of CDT remains controversial. We sought to compare the efficacy and safety of CDT with other therapeutic options using network meta-analysis. METHODS: We searched PubMed (MEDLINE), Embase, ClinicalTrials.gov and Cochrane Library from inception to Oct. 18, 2022. We included randomized controlled trials and observational studies that compared therapeutic options for PE, including anticoagulation, systemic thrombolysis and CDT among patients with intermediate- or high-risk PE. The efficacy outcome was in-hospital death. Safety outcomes included major bleeding, intracerebral hemorrhage and minor bleeding. RESULTS: We included data from 44 studies, representing 20 006 patients. Compared with systemic thrombolysis, CDT was associated with a decreased risk of death (odd ratio [OR] 0.43, 95% confidence interval [CI] 0.32-0.57), intracerebral hemorrhage (OR 0.44, 95% CI 0.29-0.64), major bleeding (OR 0.61, 95% CI 0.53-0.70) and blood transfusion (OR 0.46, 95% CI 0.28-0.77). However, no difference in minor bleeding was observed between the 2 therapeutic options (OR 1.11, 95% CI 0.66-1.87). Compared with anticoagulation, CDT was also associated with decreased risk of death (OR 0.36, 95% CI 0.25-0.52), with no increased risk of intracerebral hemorrhage (OR 1.33, 95% CI 0.63-2.79) or major bleeding (OR 1.24, 95% CI 0.88-1.75). INTERPRETATION: With moderate certainty of evidence, the risk of death and major bleeding complications was lower with CDT than with systemic thrombolysis. Compared with anticoagulation, CDT was associated with a probable lower risk of death and a similar risk of intracerebral hemorrhage, with moderate certainty of evidence. Although these findings are largely based on observational data, CDT may be considered as a first-line therapy in patients with intermediate- or high-risk PE. PROTOCOL REGISTRATION: PROSPERO - CRD42020182163.


Asunto(s)
Fibrinolíticos , Embolia Pulmonar , Humanos , Fibrinolíticos/efectos adversos , Terapia Trombolítica/efectos adversos , Metaanálisis en Red , Mortalidad Hospitalaria , Resultado del Tratamiento , Embolia Pulmonar/tratamiento farmacológico , Embolia Pulmonar/etiología , Catéteres , Anticoagulantes/uso terapéutico , Hemorragia Cerebral/inducido químicamente , Hemorragia Cerebral/tratamiento farmacológico
10.
J Clin Med ; 12(11)2023 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-37298043

RESUMEN

BACKGROUND: The association between Body Mass Index (BMI) and clinical outcomes following sepsis continues to be debated. We aimed to investigate the relationship between BMI and in-hospital clinical course and mortality in patients hospitalized with bacteremic sepsis using real-world data. METHODS: A sampled cohort of patients hospitalized with bacteremic sepsis between October 2015 and December 2016 was identified in the National Inpatient Sample (NIS) database. In-hospital mortality and length of stay were defined as the relevant outcomes. Patients were divided into 6 BMI (kg/m2) subgroups; (1) underweight ≤ 19, (2) normal-weight 20-25, (3) over-weight 26-30, (4) obese I 31-35, (5) obese II 36-39, and (6) obese stage III ≥ 40. A multivariable logistic regression model was used to find predictors of mortality, and a linear regression model was used to find predictors of an extended length of stay (LOS). RESULTS: An estimated total of 90,760 hospitalizations for bacteremic sepsis across the U.S. were analyzed. The data showed a reverse-J-shaped relationship between BMI and study population outcomes, with the underweight patients (BMI ≤ 19 kg/m2) suffering from higher mortality and longer LOS as did the normal-weight patients (BMI 20-25 kg/m2) when compared to the higher BMI groups. The seemingly protective effect of a higher BMI diminished in the highest BMI group (BMI ≥ 40 kg/m2). In the multivariable regression model, BMI subgroups of ≤19 kg/m2 and ≥40 kg/m2 were found to be independent predictors of mortality. CONCLUSIONS: A reverse-J-shaped relationship between BMI and mortality was documented, confirming the "obesity paradox" in the real-world setting in patients hospitalized for sepsis and bacteremia.

11.
Eur Heart J Case Rep ; 7(5): ytad226, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37207107

RESUMEN

Background: Transcatheter edge-to-edge repair (TEER) repair is a minimally invasive procedure used for patients with severe mitral regurgitation (MR). Cardioversion is indicated for haemodynamically unstable patients with narrow complex tachycardia and is generally considered safe post-mitral clip. We present a patient who underwent cardioversion post-TEER with a single leaflet detachment (SLD). Case summary: An 86-year-old female with severe MR underwent TEER with a MitraClip that reduced MR severity to mild. During the procedure, the patient experienced tachycardia, and cardioversion was performed successfully. However, immediately after the cardioversion, the operators noticed recurrent severe MR with a posterior leaflet clip detachment. Deployment of a new clip adjacent to the detached one was obtained. Discussion: Transcatheter edge-to-edge repair is a well-established method for treating severe MR in patients who are not suitable for surgical intervention. However, complications can arise during or after the procedure, such as clip detachment as in this case. Several mechanisms can explain SLD. We presumed that in the current case, immediately after cardioversion, there was an acute (post-pause) increase in left ventricle end-diastolic volume and thus in the left ventricle systolic volume with more vigorous contraction, possibly pulling apart the leaflets and detaching the freshly applied TEER device. This is the first report of SLD related to electrical cardioversion after TEER. Even though electrical cardioversion is considered safe, SLD can occur in this setting.

12.
Cardiology ; 148(3): 278-286, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37080172

RESUMEN

INTRODUCTION: Tricuspid regurgitation (TR) is a common finding which appears to be associated with a worse prognosis. There are conflicting data regarding the prognostic impact of mild TR. We examined the clinical characteristics and echocardiographic properties of subjects with TR and its impact on clinical outcome with particular emphasis on subjects with mild TR. METHODS: Consecutive echocardiography examinations during 5 years were evaluated for TR severity and outcome including mortality and cardiovascular hospitalizations. RESULTS: The study included 21,429 subjects; 45% of the subjects had mild TR, 15% had moderate TR, and 6.5% had severe TR. Primary organic TR was evident in 7% of the subjects, a percentage that increased with increasing TR severity. TR severity was incrementally associated with older subjects with an increasing number of comorbidities and echocardiographic abnormalities. 29% of the subjects died at a median follow-up duration of 8.7 years. Increasing severity of TR was independently and incrementally associated with mortality. Subjects with mild TR had a 25% increased mortality rate compared to subjects with minimal TR (HR 1.25, 95% CI: 1.12-1.39, p < 0.001) after adjustment for significant clinical parameters. TR severity was also an independent incrementally graded predictor of cardiovascular hospitalization and mortality (mild TR: HR 1.23, 95% CI: 1.12-1.34, p < 0.001). CONCLUSIONS: TR is associated with older and sicker patients with numerous comorbidities. TR severity is a predictor of a worse clinical outcome. Mild TR was independently associated with decreased survival. TR should be considered a marker of a disease burden with a poor prognosis.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Estudios Retrospectivos , Ecocardiografía , Pronóstico , Comorbilidad , Índice de Severidad de la Enfermedad
13.
Med ; 4(4): 263-281.e4, 2023 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-37060900

RESUMEN

BACKGROUND: Vascular endothelial cells (VECs) are an essential component of each tissue, contribute to multiple pathologies, and are targeted by important drugs. Yet, there is a shortage of biomarkers to assess VEC turnover. METHODS: To develop DNA methylation-based liquid biopsies for VECs, we determined the methylome of VECs isolated from freshly dissociated human tissues. FINDINGS: A comparison with a human cell-type methylome atlas yielded thousands of loci that are uniquely unmethylated in VECs. These sites are typically gene enhancers, often residing adjacent to VEC-specific genes. We also identified hundreds of genomic loci that are differentially methylated in organotypic VECs, indicating that VECs feeding specific organs are distinct cell types with a stable epigenetic identity. We established universal and lung-specific VEC markers and evaluated their presence in circulating cell-free DNA (cfDNA). Nearly 2.5% of cfDNA in the plasma of healthy individuals originates from VECs. Sepsis, graft versus host disease, and cardiac catheterization are associated with elevated levels of VEC-derived cfDNA, indicative of vascular damage. Lung-specific VEC cfDNA is selectively elevated in patients with chronic obstructive pulmonary disease (COPD) or lung cancer, revealing tissue-specific vascular turnover. CONCLUSIONS: VEC cfDNA biomarkers inform vascular dynamics in health and disease, potentially contributing to early diagnosis and monitoring of pathologies, and assessment of drug activity. FUNDING: This work was supported by the Beutler Research Program, Helmsley Charitable Trust, JDRF, Grail and the DON Foundation (to Y.D.). Y.D holds the Walter & Greta Stiel Chair in heart studies. B.G., R.S., J.M., D.N., T.K., and Y.D. filed patents on cfDNA analysis.


Asunto(s)
Ácidos Nucleicos Libres de Células , Epigenoma , Humanos , Endotelio Vascular , Células Endoteliales/metabolismo , Biomarcadores/metabolismo , Biopsia Líquida
14.
J Clin Med ; 12(7)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37048686

RESUMEN

Background: Cardiogenic shock (CS) continues to be a severe and fatal complication of acute coronary syndrome (ACS). CS patients have a high mortality rate despite significant progress in primary reperfusion, the management of heart failure and the expansion of mechanical circulatory support strategies. The present study addressed the clinical characteristics, management, and outcomes of ACS patients complicated with CS. Methods: We performed an observational study, using the 2000-2013 Acute Coronary Syndrome Israeli Surveys (ACSIS) database and identified hospitalizations of ACS patients complicated with CS. Patients' demographics and clinical characteristics, complications and outcomes were evaluated. We assessed the outcomes of ACS patients with CS at arrival (on the day of admission) compared with ACS patients who arrived without CS and developed CS during hospitalization. Results: The cohort included 13,434 patients with ACS diagnoses during the study period. Of these, 4.2% were complicated with CS; 224 patients were admitted with both ACS and CS; while 341 ACS patients developed CS only during the hospitalization period. The latter patients had significantly higher rates of MACEs compared with the group of ACS patients who presented with CS at arrival (73% vs. 51%; p < 0.0001). Similarly, the rates of in-hospital mortality (55% vs. 36%; p < 0.0001), 30-day mortality (64% vs. 50%; p = 0.0013) and 1-year mortality (73% vs. 59%; p = 0.0016) were higher in ACS patients who developed CS during hospitalization vs. ACS patients with CS at admission. There was a significant decrease in 1-year mortality trends during the 13 years of this study presented in ACS patients from both groups. Conclusions: Patients who developed CS during hospitalization had higher mortality and MACE rates compared with those who presented with CS at arrival. Further studies should focus on this subgroup of high-risk patients.

15.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36938963

RESUMEN

AIMS: Several procedural and electrocardiogram (ECG) parameters have been associated with the occurrence of high-degree atrioventricular block (AVB) requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). We hereunder sought to assess if the baseline R-wave amplitude in V1 ECG lead of patients with normal QRS duration undergoing TAVR is associated with a higher patient's risk for developing high-degree AVB following left bundle branch block (LBBB). METHODS AND RESULTS: In this retrospective single-centre study in 720 consecutive patients who underwent TAVR, 141 (19.6%) patients with normal QRS duration developed a new LBBB after TAVR. The 24 (17%) patients who underwent PPI for reasons other than high-degree AVB were excluded from further analysis. In the remaining 117 study patients, 14 (12%) developed high-degree AVB requiring PPI (Group 1) while the remaining 103 (88%) patients did not (Group 2). There were no significant differences in baseline demographic or procedural characteristics nor in PR interval, QRS duration, and QRS axis between these two groups. The incidence of left anterior hemiblock was higher in Group 1 (3 of 14, 21.4%) than that in Group 2 (9 of 103, 8.7%), but the difference was not statistically significant (P = 0.156). The R-wave amplitude in V1 was smaller in Group 1 than that in Group 2 (0.029 ± 0.04 mV vs. 0.11 ± 0.14 mV, P = 0.0316). In the receiver-operating characteristics analysis, the cutoff for R-wave amplitude pre-TAVR was 0.03 mV, area under the curve = 0.7219 (P = 0.0002). CONCLUSION: The R-wave amplitude in lead V1 during baseline ECG in patients with normal QRS duration may predict the occurrence of high-degree AVB following new LBBB after TAVR.


Asunto(s)
Bloqueo Atrioventricular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Electrocardiografía/métodos , Arritmias Cardíacas
17.
Ann Surg ; 277(2): e460-e466, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33714965

RESUMEN

OBJECTIVE: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch. SUMMARY BACKGROUND DATA: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks. METHODS: Patients underwent transcatheter aortic arch repair with a single branch, 2 stent graft system, implanted over a through-and-through guidewire from the brachiocephalic trunk, to the descending aorta with an ascending aorta stent graft. The ascending aorta stent graft is deployed into a designated docking sleeve to connect the 2 stent grafts and isolate the aortic arch pathology. Proximal landing zone in all cases was in Zone 0. Anatomical inclusion criteria included adequate landing zone in the ascending aorta, brachiocephalic trunk, and descending thoracic aorta. Preparatory debranching procedure was performed in all patients with carotid-carotid crossover bypass and left carotid to left subclavian bypass, or parallel graft from descending aorta to left subclavian artery. Safety and performance were evaluated through 1 year. Survival analysis used the Kaplan-Meier method. RESULTS: Twenty-eight patients, 79% males, with a mean age of 72.2 ± 6.2 years were treated with 100% procedural success. Isolated aortic arch aneurysm was the principle pathology in 17 (60.7%) of patients, while chronic aortic dissection was the principle pathology in 6 (21.4%) of patients. The remaining 5 (17.8%) had combined or other pathologies. At 1 month, the vascular pathology was excluded in 25 of 26 alive patients (96.1%). The 30 days mortality rate was 7.1%, stroke rate was 3.6% (all nondisabling), and combined mortality/stroke rate was 10.7%. One-year mortality was 10.7%, without device or aneurysm-related death. Two patients (7.1%) reported stroke or transient ischemic attack at 1 year that recovered completely. One year combined mortality/stroke rate was 17.8%. There were 3 patients (10.7%) that had device-related unplanned reinterventions through 1 year. CONCLUSIONS: The NEXUS Aortic Arch Stent Graft System, a novel single branch, 2 stent graft system used for endovascular aortic arch repair that requires landing in the ascending aorta, demonstrates a high success rate with excellent 1 year safety and performance.


Asunto(s)
Disección Aórtica , Accidente Cerebrovascular , Masculino , Humanos , Anciano , Femenino , Aorta Torácica/cirugía , Aorta , Stents , Disección Aórtica/cirugía
18.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-36484696

RESUMEN

OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Prótesis Vascular/efectos adversos , Endofuga/epidemiología , Endofuga/etiología , Reparación Endovascular de Aneurismas , Estudios de Seguimiento , Estudios Prospectivos , Complicaciones Posoperatorias , Stents/efectos adversos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Estudios Retrospectivos
19.
Front Cardiovasc Med ; 9: 1013739, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36329995

RESUMEN

Background: Based on worldwide registries, approximately 50% of patients who underwent transcatheter aortic valve replacement (TAVR) are female patients. Although TAVR procedures have improved tremendously in recent years, differences in outcome including mortality between sexes remain. We aimed to investigate the trends in TAVR in the early and new eras of utilization and to assess TAVR outcomes in female patients vs. male patients. Methods: Using the 2011-2017 National Inpatient Sample (NIS) database, we identified hospitalizations for patients with the diagnosis of aortic stenosis during which a TAVR was performed. Patients' sociodemographic and clinical characteristics, procedure complications, and mortality were analyzed. Piecewise regression analyses were performed to assess temporal trends in TAVR utilization in female patients and in male patients. Multivariable analysis was performed to identify predictors of in-hospital mortality. Results: A total of 150,647 hospitalizations for TAVR across the United States were analyzed during 2011-2017. During the study period, a steady upward trend was observed for TAVR procedures in both sexes. From 2011 to 2017, there were significantly more TAVR procedures performed in men [80,477 (53.4%)] than in women [70,170 (46.6%)]. Male patients had significantly higher Deyo-CCI score and comorbidities. Differences in mortality rates among sexes were observed, presenting with higher in-hospital mortality in women than in men, OR 1.26 [95% CI 1.18-1.35], p < 0.001. Conclusion: Utilization of TAVR demonstrated a steady upward trend during 2011-2017, and a similar trend was presented for both sexes. Higher in-hospital mortality was recorded in female patients compared to male patients. Complication rates decreased over the years but without effect on mortality differences between the sex groups.

20.
Catheter Cardiovasc Interv ; 100(5): 832-838, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116033

RESUMEN

OBJECTIVE: Patients with rapidly deteriorating clinical status due to severe aortic stenosis are often referred for expedited transcatheter aortic valve replacement (TAVR). Data regarding the outcome of such interventions is limited. We aimed to evaluate the outcome of patients undergoing expedited TAVR. DESIGN AND SETTING: Data were derived from the Israeli Multicenter Registry. SUBJECTS: Subjects were divided into two groups based on procedure urgency: patients who were electively hospitalized for the procedure (N = 3140) and those who had an expedited TAVR (N = 142). Procedural and periprocedural complication rates were significantly higher among patients with an expedited indication for TAVR compared to those having an elective procedure: valve malposition 4.6% versus 0.6% (p < 0.001), procedural cardiopulmonary resuscitation 4.3% versus 1.0% (p = 0.007), postprocedure myocardial infarction 2.0% versus 0.4% (p = 0.002), and stage 3 acute kidney injury 3.0% versus 1.1%, (p < 0.001). Patients with expedited indication for TAVR had significantly higher in hospital mortality (5.6% vs. 1.4%, p = 0.003). Kaplan-Meier's survival analysis showed that patients undergoing expedited TAVR had higher 3-year mortality rates compared to patients undergoing an elective TAVR procedure (p < 0.001). Multivariate analysis found that patients with expedited indication had fourfolds increased risk of in-hospital mortality (odds ratio: 4.07, p = 0.001), and nearly twofolds increased risk of mortality at 3-year (hazard ratio: 1.69, p = 0.001) compared to those having an elective procedure. CONCLUSION: Patients with expedited indications for TAVR suffer from poor short- and long-term outcomes. It is important to characterize and identify these patients before the deterioration to perform TAVR in a fast-track pathway to minimize their procedural risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Factores de Riesgo , Catéteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...