Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 39(2): 316-25, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22124778

RESUMEN

PURPOSE: State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. METHODS: Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of (18)F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. RESULTS: Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. CONCLUSION: Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications.


Asunto(s)
Medios de Contraste/farmacología , Fluorodesoxiglucosa F18/farmacología , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Diagnóstico por Imagen/métodos , Reacciones Falso Positivas , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
2.
Strahlenther Onkol ; 187(7): 426-32, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21713396

RESUMEN

BACKGROUND AND PURPOSE: To investigate prostate movement during deep breathing and contraction of abdominal musculature by means of dynamic MRI and analyze implications for image-guided radiotherapy of prostate cancer. PATIENTS AND METHODS: A total of 43 patients and 8 healthy volunteers were examined with MRI. Images during deep respiration and during contraction of abdominal musculature (via a coughing maneuver) were obtained with dynamic two-dimensional (2D) balanced SSFP; 3 frames/s were obtained over an acquisition time of 15 s. Images were acquired in sagittal orientation to evaluate motion along both the craniocaudal (cc)-axis and anteroposterior (ap)-axis. Prostate motion was quantified semi-automatically using dedicated software tools. RESULTS: Respiratory induced mean cc-axis displacement of the prostate was 2.7 ± 1.9 (SD) mm (range, 0.5-10.6 mm) and mean ap-axis displacement 1.8 ± 1.0 (SD) mm (range, 0.3-10 mm). In 69% of the subjects, breathing-related prostate movements were found to be negligible (< 3 mm). The prostate displacement for abdominal contraction was significantly higher: mean cc-axis displacement was max. 8.4 ± 6.7 (SD) mm (range, 0.6-27 mm); mean anteroposterior movement was 8.3 ± 7.7 (SD) mm (range, 0.7-26 mm). CONCLUSION: Dynamic MRI is an excellent tool for noninvasive real-time imaging of prostate movement. Further investigations regarding possible applications in image-guided radiotherapy, e.g., for individualized planning and in integrated linac/MRI systems, are warranted.


Asunto(s)
Adenocarcinoma/radioterapia , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Próstata/efectos de la radiación , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Asistida por Computador/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Músculos Abdominales/fisiopatología , Adenocarcinoma/patología , Adenocarcinoma/fisiopatología , Adulto , Anciano , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Movimiento , Contracción Muscular/fisiología , Estadificación de Neoplasias , Próstata/patología , Próstata/fisiopatología , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/fisiopatología , Sensibilidad y Especificidad
3.
Strahlenther Onkol ; 187(4): 252-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21437769

RESUMEN

BACKGROUND: Hypoxia inducible factor-1 has been identified as a potential target to overcome hypoxia-induced radioresistance The aim of the present study was to investigate whether selective HIF-1 inhibition via small interfering RNA (siRNA) targeting hypoxia-inducible factor 1α (HIF-1α) affects hypoxia-induced radioresistance in HT 1080 human fibrosarcoma cells. MATERIAL AND METHODS: HIF-1α expression in HT 1080 human fibrosarcoma cells in vitro was silenced using HIF-1α siRNA sequence primers. Quantitative real-time polymerase chain reaction assay was performed to quantify the mRNA expression of HIF-1α. HIF-1α protein levels were studied by Western blotting at 20% (air) or after 12 hours at 0.1% O2 (hypoxia). Cells were assayed for clonogenic survival after irradiation with 2, 5, or 10 Gy, under normoxic or hypoxic conditions in the presence of HIF-1α-targeted or control siRNA sequences. A modified oxygen enhancement ratio (OER´) was calculated as the ratio of the doses to achieve the same survival at 0.1% O(2) as at ambient oxygen tensions. OER´ was obtained at cell survival levels of 50%, 37%, and 10%. RESULTS: HIF-1α-targeted siRNA enhanced radiation treatment efficacy under severely hypoxic conditions compared to tumor cells treated with scrambled control siRNA. OER was reduced on all survival levels after treatment with HIF-1α-targeted siRNA, suggesting that inhibition of HIF-1 activation by using HIF-1α-targeted siRNA increases radiosensitivity of hypoxic tumor cells in vitro. CONCLUSION: Inhibition of HIF-1 activation by using HIF-1α-targeted siRNA clearly acts synergistically with radiotherapy and increase radiosensitivity of hypoxic cells in vitro.


Asunto(s)
Hipoxia de la Célula/genética , Supervivencia Celular/genética , Supervivencia Celular/efectos de la radiación , Fibrosarcoma/patología , Silenciador del Gen , Subunidad alfa del Factor 1 Inducible por Hipoxia/genética , Tolerancia a Radiación/genética , Transcripción Genética/genética , Células Tumorales Cultivadas/efectos de la radiación , Línea Celular Tumoral , Relación Dosis-Respuesta en la Radiación , Humanos , ARN Mensajero/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Ensayo de Tumor de Célula Madre
4.
Int J Radiat Oncol Biol Phys ; 77(5): 1369-74, 2010 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-19932943

RESUMEN

PURPOSE: Normal tissue changes (NTC) of the normal lung parenchyma are commonly seen after stereotactic single-dose radiotherapy (radiosurgery) of lung tumors. The aim of this study was to investigate the extent and dynamics of NTCs after radiosurgery. METHODS AND MATERIALS: Fifty lung tumors in 49 patients were treated with radiosurgery. Follow-up CTs were anatomically matched to the treatment planning CTs, incorporating the treatment plan and enabling spatial correlation of initial radiation dose distribution and subsequent NTCs of the lung. Lung parenchyma was divided into nine areas of different radiation dose exposures (range, 6-35 Gy). Areas were investigated and compared at different time points according to the development of NTCs. RESULTS: Twenty-six patients developed NTCs during follow-up. The evaluation of the dependency of the extent of NTCs on the amount of radiation dose lead to a linear model for the fixed effects: Fraction of reacting volume =Intercept(T) +0.0208 * Dose ("Dose" should be given in Gy). Dose had a slope of 0.0208 (fraction of normal tissue reaction/Gy) (SE 0.000804, p < 0.0001), implying a significant correlation between dose level and the extent of NTC. CONCLUSION: For radiosurgery of lung tumors, a significant correlation of radiation dose and the extent of NTCs could be demonstrated. Using the introduced formula, a preview on the extent of NTCs to develop in normal lung parenchyma according to the dose level can be performed.


Asunto(s)
Neoplasias Pulmonares/cirugía , Pulmón/efectos de la radiación , Traumatismos por Radiación/patología , Radiocirugia/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Fibrosis Pulmonar/diagnóstico por imagen , Fibrosis Pulmonar/etiología , Traumatismos por Radiación/diagnóstico por imagen , Radiografía , Radiocirugia/efectos adversos , Dosificación Radioterapéutica , Factores de Tiempo
5.
Korean J Radiol ; 10(6): 559-67, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19885311

RESUMEN

OBJECTIVE: To estimate a new technique for quantifying regional lung motion using 3D-MRI in healthy volunteers and to apply the technique in patients with intra- or extrapulmonary tumors. MATERIALS AND METHODS: Intraparenchymal lung motion during a whole breathing cycle was quantified in 30 healthy volunteers using 3D-dynamic MRI (FLASH [fast low angle shot] 3D, TRICKS [time-resolved interpolated contrast kinetics]). Qualitative and quantitative vector color maps and cumulative histograms were performed using an introduced semiautomatic algorithm. An analysis of lung motion was performed and correlated with an established 2D-MRI technique for verification. As a proof of concept, the technique was applied in five patients with non-small cell lung cancer (NSCLC) and 5 patients with malignant pleural mesothelioma (MPM). RESULTS: The correlation between intraparenchymal lung motion of the basal lung parts and the 2D-MRI technique was significant (r = 0.89, p < 0.05). Also, the vector color maps quantitatively illustrated regional lung motion in all healthy volunteers. No differences were observed between both hemithoraces, which was verified by cumulative histograms. The patients with NSCLC showed a local lack of lung motion in the area of the tumor. In the patients with MPM, there was global diminished motion of the tumor bearing hemithorax, which improved significantly after chemotherapy (CHT) (assessed by the 2D- and 3D-techniques) (p < 0.01). Using global spirometry, an improvement could also be shown (vital capacity 2.9 +/- 0.5 versus 3.4 L +/- 0.6, FEV1 0.9 +/- 0.2 versus 1.4 +/- 0.2 L) after CHT, but this improvement was not significant. CONCLUSION: A 3D-dynamic MRI is able to quantify intraparenchymal lung motion. Local and global parenchymal pathologies can be precisely located and might be a new tool used to quantify even slight changes in lung motion (e.g. in therapy monitoring, follow-up studies or even benign lung diseases).


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/fisiopatología , Imagenología Tridimensional , Neoplasias Pulmonares/fisiopatología , Imagen por Resonancia Magnética/métodos , Mesotelioma/fisiopatología , Movimiento/fisiología , Estudios de Casos y Controles , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad
6.
Int J Radiat Oncol Biol Phys ; 73(3): 919-26, 2009 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-19215826

RESUMEN

PURPOSE: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). METHODS AND MATERIALS: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24 x 10(2)/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution approximately 1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. RESULTS: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). CONCLUSIONS: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.


Asunto(s)
Neoplasias Pulmonares , Pulmón , Movimiento , Nódulos Pulmonares Múltiples , Respiración , Animales , Tomografía Computarizada de Haz Cónico/métodos , Diseño de Equipo , Pulmón/diagnóstico por imagen , Pulmón/patología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Nódulos Pulmonares Múltiples/patología , Variaciones Dependientes del Observador , Aceleradores de Partículas , Fantasmas de Imagen , Reproducibilidad de los Resultados , Porcinos , Tomografía Computarizada Espiral/métodos
7.
Invest Radiol ; 43(10): 737-44, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18791416

RESUMEN

OBJECTIVE: To evaluate and compare the role of computed tomography (CT), positron emission tomography (PET), PET/CT, and magnetic resonance imaging (MRI) in the correct staging of patients with limited malignant pleural mesothelioma (MPM). MATERIALS AND METHODS: Fifty-four patients with an epithelial MPM (34 men and 20 women) were included in this study. Patients were referred to our department for staging in a predicted resectable state (stage II/III). Within 3 days, PET/CT and MRI was performed in all patients. Images were evaluated by 3 specialists in the field of PET/CT and MRI. The subexaminations of PET/CT, PET, and CT were independently evaluated with respect to tumor stage. Subexaminations were compared with each other, with MRI and PET/CT. N-stage was verified by mediastinoscopy. Afterward, consensus reading was performed.In 52 patients, surgery served as gold standard. In 2 patients, follow-up control served as gold standard as an inoperable situation with distant metastases was found. Additionally, interobserver variability (kappa value) was calculated. RESULTS: In stage II, accuracy was 0.77 (CT), 0.86 (PET), 0.8 (MRI), 1.0 (PET/CT), and in stage III 0.75, 0.83, 0.9, 1.0. PET/CT was significantly more accurate (P < 0.05) in stages II and III compared with all other techniques. CT and MRI were not able to detect distant metastases in 2 patients, which changed therapy (operable vs. inoperable). Interobserver variability was 0.7, 0.9, 0.8, 1.0 in stage II and 0.9, 0.9, 0.9, 1.0 in stage III. CONCLUSION: PET/CT makes it possible to stage patients with limited MPM with high accuracy and low interobserver variability.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Mesotelioma/diagnóstico , Tomografía de Emisión de Positrones/instrumentación , Anciano , Femenino , Humanos , Estado de Ejecución de Karnofsky , Masculino , Mesotelioma/fisiopatología , Persona de Mediana Edad , Estadificación de Neoplasias/instrumentación , Estadificación de Neoplasias/métodos , Tomografía Computarizada por Rayos X/instrumentación
8.
J Nucl Med ; 49 Suppl 2: 43S-63S, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18523065

RESUMEN

Molecular imaging of tumor metabolism has gained considerable interest, since preclinical studies have indicated a close relationship between the activation of various oncogenes and alterations of cellular metabolism. Furthermore, several clinical trials have shown that metabolic imaging can significantly impact patient management by improving tumor staging, restaging, radiation treatment planning, and monitoring of tumor response to therapy. In this review, we summarize recent data on the molecular mechanisms underlying the increased metabolic activity of cancer cells and discuss imaging techniques for studies of tumor glucose, lipid, and amino acid metabolism.


Asunto(s)
Transformación Celular Neoplásica/metabolismo , Neoplasias/metabolismo , Aminoácidos/metabolismo , Animales , Transporte Biológico , Transformación Celular Neoplásica/patología , Estructuras Celulares/metabolismo , Fluorodesoxiglucosa F18 , Glucosa/metabolismo , Humanos , Metabolismo de los Lípidos , Imagen por Resonancia Magnética , Neoplasias/diagnóstico por imagen , Neoplasias/patología , Oncogenes/fisiología , Tomografía de Emisión de Positrones , Radiofármacos
9.
Invest Radiol ; 43(5): 290-7, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18424949

RESUMEN

OBJECTIVE: To evaluate and compare positron emission tomography/computed tomography (PET/CT) with whole-body magnetic resonance imaging (wbMRI) in the correct staging of patients with advanced nonsmall cell lung cancer (NSCLC). MATERIALS AND METHODS: Fifty-two patients with an NSCLC stage IIIa or IIIb (36 males and 16 females) were included in this study. Patients were referred to our department for restaging. Within 1 week PET/CT and wbMRI were performed in all patients. Images were examined independently by 2 experienced physicians from the Department of Nuclear Medicine and Radiology. Afterward, consensus reading was performed. In 22 patients, surgery served as gold standard, whereas in 30 patients, follow-up controls (after 2 months) were performed. RESULTS: The use of wbMRI correctly T-staged all patients. Especially volume interpolated breathhold examination sequence correctly T-staged all tumors. PET/CT did not correctly stage chest wall infiltration in 4 cases [sensitivity 92.3% (P < 0.05 to wbMRI)/specificity 100%], verified by surgery. PET/CT correctly N-staged 51 patients (sensitivity 96.1%/specificity 100%). WbMRI showed a significant tendency to understage N-status [sensitivity 88.5% (P < 0.05)/specificity 96.1%]. Different N-status by PET/CT changed operability in 4 patients. In 2 patients, distant metastases were detected by both techniques. CONCLUSION: In the correct staging of advanced NSCLC, PET/CT has advantages in N-staging. This is of high relevance for therapy planning. WbMRI especially using volume interpolated breathhold examination sequences, has certain advantages in T-staging.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Pulmón/patología , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/métodos , Anciano , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Medios de Contraste/administración & dosificación , Femenino , Fluorodesoxiglucosa F18 , Estudios de Seguimiento , Humanos , Aumento de la Imagen/métodos , Yohexol/análogos & derivados , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Eur Radiol ; 18(8): 1635-43, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18369634

RESUMEN

To evaluate and compare early therapy response according to RECIST (response evaluation criteria in solid tumours) and modified RECIST criteria using MRI techniques in patients with malignant pleural mesothelioma (MPM) in comparison with CT. Fifty patients with MPM (32 male/18 female) were included in this study. Early therapy response was evaluated after 9 weeks [three of six chemotherapy (CHT)] cycles. Additionally patients were examined before chemotherapy, 4 weeks after early therapy response evaluation and after six cycles to evaluate diagnostic follow-up. RECIST and modified RECIST criteria were applied using CT and MRI (HASTE, VIBE, T2-TSE sequences). In MRI additionally a volumetric approach measuring tumour weight (overall segmented tumour volume) was applied. Additionally vital capacity (VC) was measured for correlation. Image interpretation was performed by three independent readers independently and in consensus. The 'gold standard' was follow-up examination. Twenty-eight patients showed partial response, 12 patients stable disease and 10 patients progressive disease at early therapy response evaluation. In the follow-up these results remained. For MRI, in 46 cases patients were identically classified using RECIST and modified RECIST criteria. Modified RECIST criteria were identically classified as gold standards in all cases, whereas using RECIST criteria in four cases there was a mismatch (partial response vs. stable disease). Modified RECIST kappa values showed better interobserver variability compared with RECIST criteria (kappa=0.9-1.0 vs. 0.7-1.0). For CT, in 44 cases patients were identically classified using RECIST and modified RECIST criteria. Modified RECIST criteria were identically classified as in gold standards in 48 out of 50 patients, whereas using RECIST criteria in 6 cases there was a mismatch (partial response vs. stable disease). Modified RECIST kappa values showed better interobserver variability compared with RECIST criteria (kappa=0.9-1.0 vs. 0.6-1.0). Modified RECIST criteria especially in combination with high-resolution MRI is a very accurate and reproducible technique to correctly evaluate early therapy response in MPM.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Mesotelioma/diagnóstico , Mesotelioma/terapia , Neoplasias Pleurales/diagnóstico , Neoplasias Pleurales/terapia , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud/métodos , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
11.
Invest Radiol ; 42(10): 715-25, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17984769

RESUMEN

OBJECTIVES: As pulmonary complications are life limiting in patients with cystic fibrosis (CF), repeated chest imaging [chest x-ray, computed tomography (CT)] is needed for follow up. With the continuously rising life expectancy of CF patients, magnetic resonance imaging (MRI) as a radiation-free imaging modality might become more and more attractive. The goal of this study was to prospectively assess the value of MRI for evaluation of morphologic pulmonary CF-changes in comparison to established imaging modalities. MATERIALS AND METHODS: Thirty-one CF patients (19 female, 12 male; mean age 16.7 years) with stable lung disease were examined by MRI: HASTE, coronal/transversal (TR/TE/alpha/TA: infinite/28 ms/180 degrees /18 s), multi-detector computed tomography (MDCT) (30 patients): 120 kV, dose modulated mAs, and chest x-ray (21 patients). Image evaluation: random order, 4 chest radiologists in consensus; chest x-ray: modified Chrispin-Norman score; CT and MRI: modified Helbich score. The maximal attainable score for chest x-ray was 34, for MRI and CT 25. Median scores, Pearson correlation coefficients, Bland-Altman plots, and concordance of MRI to CT on a lobar and segmental basis were calculated. RESULTS: The median MRI and MDCT scores were 13 (min 3, max 20) respectively 13.5 (min 0, max 20). The median chest x-ray score was 14 (min 5, max 32). Pearson correlation coefficients: MRI/CT = 0.80, P < 0.0001; MRI/chest x-ray = 0.63, P < 0.0018; chest x-ray/CT = 0.75, P < 0.0001. The median lobe related concordance was 80% for bronchiectasis, 77% for mucus plugging, 93%, for sacculation/abscesses, and 100% for collapse/consolidation. CONCLUSIONS: Morphologic MRI of the lung in CF patients demonstrates comparable results to MDCT and chest x-ray. Because radiation exposure is an issue in CF patients, MRI might have the ability to be used as an appropriate alternative method for pulmonary imaging.


Asunto(s)
Fibrosis Quística/patología , Enfermedades Pulmonares/patología , Pulmón/patología , Imagen por Resonancia Magnética/instrumentación , Adolescente , Fibrosis Quística/diagnóstico por imagen , Progresión de la Enfermedad , Femenino , Indicadores de Salud , Humanos , Pulmón/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico por imagen , Masculino , Estudios Prospectivos , Radiografía , Tomografía Computarizada de Emisión/instrumentación
12.
J Magn Reson Imaging ; 26(6): 1523-9, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17968900

RESUMEN

PURPOSE: To evaluate an optimized method for oxygen-enhanced MRI of the lung, using simultaneous electrocardiograph (ECG) and navigator triggering. To correlate oxygen-enhanced MRI with lung function tests assessing alveolar-capillary gas exchange. MATERIALS AND METHODS: A total of 12 healthy volunteers (aged 20-32 years) and 10 patients (aged 37-87 years) with interstitial lung diseases (ILD) underwent oxygen-enhanced MRI and pulmonary functional tests (PFTs) assessing alveolar-capillary gas exchange. The paradigm room-air-oxygen-room-air was acquired with a nonselective inversion-recovery half-Fourier single-shot turbo spin-echo sequence (inversion time = 1200 msec; acquisition time = 134.5 msec; slice thickness = 20 mm; matrix size = 128 x 128), using simultaneous double triggering (navigator plus ECG trigger). Cross-correlation was performed in regions of interest (ROIs) encompassing both lungs. The number of oxygen-activated pixels over the total number of pixels in the ROIs (OAP%) of volunteers and patients was compared. OAP%s were correlated with PFTs. RESULTS: The mean OAP% of patients was significantly lower than that of volunteers (36.7 vs. 81.7, P = 0.001). OAP% correlated with the transfer lung factor for carbon monoxide (Tlco) (r = 0.64; P = 0.002), the transfer coefficient (Kco) (r = 0.75; P = 0.001), the arterial partial pressure (r = 0.77; P < 0.001), and the saturation (r = 0.70; P < 0.001) of oxygen. CONCLUSION: Navigator-triggered oxygen-enhanced MRI of the lung may have a potential role in the quantitative assessment of lung function in ILD.


Asunto(s)
Enfermedades Pulmonares Intersticiales/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Electrocardiografía , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Oxígeno/metabolismo , Intercambio Gaseoso Pulmonar , Pruebas de Función Respiratoria , Mecánica Respiratoria , Estadísticas no Paramétricas
13.
Invest Radiol ; 42(9): 605-13, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17700275

RESUMEN

OBJECTIVE: To evaluate the clinical potential of diffusion-weighted-imaging (DWI) with apparent diffusion coefficient (ADC)-mapping for tumor detection. MATERIALS AND METHODS: A single-shot echo-planar-imaging DWI sequence with fat suppression and ability for navigator-based respiratory triggering was implemented. Nineteen patients (11 melanoma, 4 prostate cancer, 1 non-Hodgkin lymphoma, and 3 lung cancer) were examined by positron emission tomography (PET) with an integrated computed tomography scanner (PET-CT) and DWI. Images at b = 0, 400, and 1000 s/mm2 were acquired and ADC maps were generated. PET examinations were used as a reference for tumor detection. Four hundred twenty-four regions of interest were used for DWI and 73 for PET data evaluation. RESULTS: DWI and ADC maps were of diagnostic quality. Metastases with increased tracer uptake were clearly visualized at b = 1000 s/mm2 with the exception of mediastinal lymph node metastases in cases of lung cancer. ADC mapping did not improve detection rates. CONCLUSIONS: DWI is a feasible clinical technique, improving the assessment of metastatic spread in routine magnetic resonance imaging examinations.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias/diagnóstico , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
14.
Eur J Cancer ; 43(3): 557-64, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17224266

RESUMEN

The aim of our study was to compare the overall and site-based accuracy and impact on patient management of positron emission tomography/computed tomography (PET/CT) and whole-body (wb) magnetic resonance imaging (MRI) in staging of advanced melanoma. In a prospective blinded study, 64 patients with American Joint Committee on Cancer (AJCC) stage III/IV melanoma underwent 18F-fluorodeoxyglucose PET/CT and wbMRI. In total 420 lesions were evaluated. The overall accuracy of PET/CT was 86.7% compared to 78.8% for wbMRI (P=0.0007). PET/CT was significantly more accurate in N-staging and detecting of skin and subcutaneous metastases, whereas wbMRI was more sensitive in detecting liver, bone and brain metastases. WbMRI was less sensitive but more specific than PET/CT in classifying pulmonary lesions. In 41 patients (64%) whole-body imaging caused changes of treatment. Whole-body staging of patients with advanced melanoma is most accurate by combining wbPET/CT and organ-specific wbMRI including a brain, liver and bone marrow protocol.


Asunto(s)
Fluorodesoxiglucosa F18 , Melanoma/diagnóstico , Neoplasias Cutáneas/diagnóstico , Adulto , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Melanoma/terapia , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Tomografía de Emisión de Positrones/métodos , Estándares de Referencia , Neoplasias Cutáneas/terapia , Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero/métodos
15.
Eur Radiol ; 17(3): 716-24, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16941092

RESUMEN

Cystic fibrosis (CF) is the most frequent inherited disorder leading to premature death in the Caucasian population. As life expectancy is limited by pulmonary complications, repeated imaging [chest X-ray, multislice high-resolution computed tomography (MS-HRCT)] is required in the follow-up. Magnetic resonance imaging (MRI) of the lung parenchyma is a promising new diagnostic tool. Its value for imaging lung changes caused by CF compared with CT is demonstrated. MRI performs well when compared with CT, which serves as the gold standard. Its lack in spatial resolution is obvious, but advantages in contrast and functional assessment compensate for this limitation. Thus, MRI is a reasonable alternative for imaging the CF lung and should be introduced as a radiation-free modality for follow-up studies in CF patients. For further evaluation of the impact of MRI, systematic studies comparing MRI and conventional imaging modalities are necessary. Furthermore, the value of the additional functional MRI (fMRI) information has to be studied, and a scoring system for the morphological and functional aspect of MRI has to be established.


Asunto(s)
Bronquios/patología , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/patología , Imagen por Resonancia Magnética , Moco/metabolismo , Adolescente , Adulto , Broncografía , Niño , Femenino , Humanos , Masculino , Tomografía Computarizada por Rayos X
16.
Cancer Imaging ; 6: S140-4, 2006 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-17114068

RESUMEN

Novel technology has made dynamic magnetic resonance imaging (MRI) of lung motion and lung tumour mobility during continuous respiration feasible. This might be beneficial for planning of radiotherapy of lung tumours, especially when using high precision techniques. This paper describes the recent developments to analyze and visualize pulmonary nodules during continuous respiration using MRI. Besides recent dynamic two-dimensional approaches to quantify motion of pulmonary nodules during respiration novel three-dimensional techniques are presented. Beyond good correlation to pulmonary function tests MRI also provides regional information about differences between tumour-bearing and non-tumour bearing lung and the restrictive effects of radiotherapy as well as the compensation by the contralateral lung.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Planificación de Atención al Paciente , Tomografía Computarizada por Rayos X/métodos , Sistemas de Computación , Humanos , Imagenología Tridimensional , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Radioterapia/efectos adversos , Respiración , Mecánica Respiratoria , Carga Tumoral
17.
AJR Am J Roentgenol ; 187(2): 439-44, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16861549

RESUMEN

OBJECTIVE: The purpose of this study was to use phase-contrast MRI to evaluate the influence of various breathing maneuvers on the hemodynamics of the pulmonary and systemic arterial circulation. SUBJECTS AND METHODS: Twenty-five volunteers were examined with phase-contrast MRI. Flow measurements were acquired in the aorta, pulmonary trunk, and left and right pulmonary arteries during deep, large-volume inspiratory breath-hold, expiratory breath-hold, and smooth respiration (no breath-hold). Parameters assessed were peak velocity, blood flow, velocity gradient, and acceleration time. RESULTS: Pulmonary blood flow and peak velocity were significantly reduced during inspiratory breath-hold and expiratory breath-hold compared with no breath-hold (p < 0.01). Pulmonary velocity gradient in inspiratory breath-hold was significantly (p

Asunto(s)
Circulación Sanguínea/fisiología , Hemodinámica/fisiología , Imagen por Resonancia Magnética , Circulación Pulmonar/fisiología , Respiración , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad
18.
Radiology ; 240(2): 537-45, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16801367

RESUMEN

The purpose of this study was to prospectively evaluate the volumes and rotations of pulmonary nodules during respiration by using three-dimensional fast low-angle shot dynamic magnetic resonance (MR) imaging (1.5/0.6 [repetition time msec/echo time msec], 3.8 x 3.8 x 3.8-mm voxel size, imaging time per three-dimensional data set of 1 second). The feasibility of the technique was verified by using 130-, 40-, and 12-cm3 phantoms made of meatballs and in five patients with solitary intrapulmonary tumors (four men, one woman; median age, 60 years) at computed tomography and histologic analysis. All patients provided written informed consent, and the study was institutional review board approved. It was proved that there were no substantial differences among the 21 algorithms used to correct partial volume effects. The most precise algorithm (r > 0.9, P < .01) used to correct partial volume effects--with which mean phantom volumes of 120.8 cm3 +/- 4.1, 36.1 cm3 +/- 3.98, and 13.1 cm3 +/- 1.5 were calculated--yielded a root mean square error of 14%. The MR imaging-derived nodule volume and rotation during respiration could be quantified by using oriented bounding box techniques.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética/métodos , Anciano , Algoritmos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Respiración , Estadísticas no Paramétricas
19.
Eur Radiol ; 16(10): 2147-52, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16673092

RESUMEN

This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/alpha/ST: 600 ms/28 ms/180 degrees /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/alpha: 0.8/1.9 ms/40 degrees ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients.


Asunto(s)
Fibrosis Quística/fisiopatología , Imagenología Tridimensional , Pulmón/fisiopatología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Distribución de Chi-Cuadrado , Niño , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Pulmón/irrigación sanguínea , Masculino
20.
Invest Radiol ; 41(5): 443-8, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16625107

RESUMEN

PURPOSE: To monitor lung motion in patients with malignant pleural mesothelioma (MPM) before and after chemotherapy (CHT) using 2-dimensional (2D) and 3-dimensional (3D) dynamic MRI (dMRI) in comparison with spirometry. METHODS AND MATERIALS: Twenty-two patients with MPM were examined before CHT, as well as after 3 and 6 CHT cycles (3 months and 6 months) using 2D dMRI (trueFISP; 3 images/s) and 3D dMRI (FLASH 3D, 1 slab (52 slices)/s) using parallel imaging in combination with view-sharing technique. Maximum craniocaudal lung dimensions (2D) and lung volumes (3D) were monitored, separated into the tumor-bearing and nontumor-bearing hemithorax. Vital capacity (VC) was measured for comparison using spirometry. RESULTS: Using 2D technique, there was a significant difference between the tumor-bearing and the nontumor-bearing hemithorax before CHT (P < 0.01) and after 3 CHT cycles (P < 0.05), whereas difference was not significant in the second control. In the tumor-bearing hemithorax, mobility increased significantly from the status before versus after 3 CHT cycles (4.1 +/- 1.1 cm vs. 4.8 +/- 1.4 cm, P < 0.05). Using 3D technique, at maximum inspiration, the volume of the tumor-bearing hemithorax was 0.6 +/- 0.4 L and of the nontumor-bearing hemithorax 1.25 +/- 0.4 L before CHT. In the follow-up exams, these volumes changed to 1.05 +/- 0.4 L (P < 0.05) and 1.4 +/- 0.5 L, respectively. Using spirometry, there was no significant change in VC (1.9 +/- 0.4 L vs. 2.2 +/- 0.7 L vs. 2.2 +/- 0.9 L). CONCLUSION: dMRI is capable of monitoring changes in lung motion and volumetry in patients with MPM not detected by global spirometry. Thus, dMRI is proposed for use as a further measure of therapy response.


Asunto(s)
Imagenología Tridimensional , Pulmón/patología , Imagen por Resonancia Magnética , Mesotelioma/fisiopatología , Neoplasias Pleurales/fisiopatología , Anciano , Antineoplásicos/uso terapéutico , Femenino , Humanos , Mediciones del Volumen Pulmonar , Masculino , Mesotelioma/tratamiento farmacológico , Persona de Mediana Edad , Movimiento , Neoplasias Pleurales/tratamiento farmacológico , Espirometría , Capacidad Vital
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA