Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Res Vet Sci ; 156: 66-80, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36791579

RESUMEN

Fibre reinforced composites are attractive materials for hard tissue reconstructions, due to the high strength and low flexural modulus. However, lack of contourability in the operation theatre inhibits their clinical applications. The study presents a novel in situ contourable composite implant system for load-bearing conditions. The implant system consists of a thin bioresorbable shell with several cavities, much like bubble-wrap. The central cavity contains a semi-flexible glass fibre preform prepared using Tailored Fibre Placement method. The preform is either pre-impregnated with a light curable resin, or the resin is injected into the cavity during the surgical procedure, followed by light curing. The semi-flexible glass fibre preforms were also examined as separate devices, "miniplates". Two types of miniplates were scrutinized, a simplified pilot design and a spatially refined, "optimized" design. The optimized miniplates were implemented as biostable and bioresorbable versions. The feasibility of the in situ contourable composite implant system was demonstrated. The potential of Tailored Fibre Placement for the semi-flexible glass fibre preforms and miniplates was confirmed in a series of biomechanical tests. However, structural optimization is required. Antebrachial fractures in toy-breeds of dogs are exemplar veterinary applications of the devices; further applications in veterinary and human patients are foreseen.


Asunto(s)
Prótesis e Implantes , Humanos , Perros , Animales , Ensayo de Materiales/veterinaria , Soporte de Peso
2.
Molecules ; 26(5)2021 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-33652632

RESUMEN

The use of bioresorbable fracture fixation plates made of aliphatic polyesters have good potential due to good biocompatibility, reduced risk of stress-shielding, and eliminated need for plate removal. However, polyesters are ductile, and their handling properties are limited. We suggested an alternative, PLAMA (PolyLActide functionalized with diMethAcrylate), for the use as the matrix phase for the novel concept of the in situ curable bioresorbable load-bearing composite plate to reduce the limitations of conventional polyesters. The purpose was to obtain a preliminary understanding of the chemical and physical properties and the biological safety of PLAMA from the prospective of the novel concept. Modifications with different molecular masses (PLAMA-500 and PLAMA-1000) were synthesized. The efficiency of curing was assessed by the degree of convergence (DC). The mechanical properties were obtained by tensile test and thermomechanical analysis. The bioresorbability was investigated by immersion in simulated body fluid. The biocompatibility was studied in cell morphology and viability tests. PLAMA-500 showed better DC and mechanical properties, and slower bioresorbability than PLAMA-1000. Both did not prevent proliferation and normal morphological development of cells. We concluded that PLAMA-500 has potential for the use as the matrix material for bioresorbable load-bearing composite fracture fixation plates.


Asunto(s)
Fijación de Fractura/métodos , Fracturas Óseas/terapia , Lactosa/análogos & derivados , Poliésteres/farmacología , Ácidos Polimetacrílicos/farmacología , Implantes Absorbibles/efectos adversos , Placas Óseas/efectos adversos , Proliferación Celular/efectos de los fármacos , Humanos , Lactosa/química , Lactosa/farmacología , Ensayo de Materiales , Poliésteres/química , Ácidos Polimetacrílicos/química , Estrés Mecánico , Resistencia a la Tracción , Soporte de Peso
3.
Res Vet Sci ; 128: 183-196, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31816501

RESUMEN

In this study, we propose a novel bioresorbable bioactive implant for tibial tuberosity advancement (TTA). The implant consists of a gradually resorbing load-bearing shell which encompasses rapidly resorbing small casings loaded with silica-based bioactive glass (BG) particulates which promote bone formation and reduce the risk of infection. The shell and the casings are manufactured by 3D printing from two medical grade bioresorbable polymers (a polyglycolide/lactide based and a polydioxanone based) that have different degradation rates. The casings are expected to resorb within days after surgery to expose the BG particulates while the shell would retain the load-bearing properties of the implant for the time required by bone healing. Unlike the currently used metallic devices, the novel implant is resorbed and excreted from the body once its purpose is fulfilled. This study presents a logical progression from the in vitro characterisation of the materials and implants to the in vivo investigation of the experimental implants. This included mechanical testing of the materials, finite element analysis of a preliminary design of the novel TTA implant, assessment of the degradation behaviour of the polymers and the ion exchange of BG in simulated body fluid, and investigation of the biological response to the novel implants after implantation in rabbits. The osteointegration of the novel implants was comparable to the osteointegration of Ti6Al4V implants in the control group; the biological efficacy and safety were confirmed. The biological response was in line with the expectations. The proof of concept for the novel TTA implants was demonstrated.


Asunto(s)
Implantes Absorbibles/veterinaria , Lesiones del Ligamento Cruzado Anterior/veterinaria , Ligamento Cruzado Anterior/cirugía , Implantes Experimentales/veterinaria , Animales , Ligamento Cruzado Anterior/patología , Lesiones del Ligamento Cruzado Anterior/cirugía , Perros , Impresión Tridimensional , Conejos , Rodilla de Cuadrúpedos/cirugía , Tibia/cirugía
4.
J Mech Behav Biomed Mater ; 96: 172-185, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31048259

RESUMEN

In toy-breed dogs (bodyweight <5 kg), the fractures of the radius and ulna are particularly common and can be caused by minimal trauma. While fracture fixation using metallic plates is a feasible treatment modality, the excessive stiffness of these devices produces the underloading of the bone which may result in the adverse bone remodelling and complications in the healing of the fracture. In this study, we investigated bisphenol A glycidylmethacrylate -based glass fibre reinforced composites as potential alternatives to metals in the devices intended for the fracture fixation of the distal radius in toy-breed dogs. Four composites with different glass fibre reinforcements were prepared as rectangular specimens and as fracture fixation plates. These were mechanically tested in three-point and four-point bending. There were two controls: polyether etherketone reinforced with short carbon fibres (specimens and plates) and commercially available stainless-steel plates. Finite element simulations were used for the assessment of the behaviour of the plates. For the control stainless steel plate, the bending strength was 1.358 N*m, superior to that of any of the composite plates. The composite plate with the matrix reinforced with continuous unidirectional glass fibres had the bending strength of 1.081 N*m, which is sufficient in this clinical context. For the plates made of polyether etherketone reinforced with carbon fibres, the strength was 0.280 N*m. Similar conclusions on the biomechanical behaviour of the plates could be made solely based on the results of the finite element simulations, provided the geometries and the material properties are well defined.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación de Fractura/métodos , Vidrio/química , Ensayo de Materiales , Fenómenos Mecánicos , Metacrilatos/química , Animales , Dimerización , Perros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA