2.
Cardiovasc Intervent Radiol ; 46(11): 1562-1570, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37759089

RESUMEN

PURPOSE: To evaluate endovascular popliteal artery aneurysm repair using a an "off-label" abdominal endograft limb-module with nitinol-ring structure. MATERIALS AND METHODS: Retrospective observational study of 14 popliteal artery aneurysms in 12 male patients (mean age 76 years and median ASA grade 3) treated electively using the Anaconda™ endograft limb (Terumo Aortic) at a single teaching hospital. Eight limbs were treated percutaneously and 6 limbs required surgical arterial exposure. The mean popliteal artery aneurysm diameter treated was 3.6 cm (range 2.1-5.3 cm). Stent-graft diameters and lengths used were 10-15 and 60-140 mm, respectively. The median covered stented length was 218 mm (range 160-270 mm) and median duration of follow-up was 3.7 years. Outcomes assessed included technically successful aneurysm exclusion, primary patency, re-intervention and survival. RESULTS: All patients had successful stent-graft deployment and aneurysm exclusion, with no early complications or mortality at 30 days. Primary stent-graft patency at 1, 3 and 4 years was 93%, 75%, and 64%. By 8 years, patency had declined with 29% (2/14) stent-grafts patent. 7/14 limbs occluded; 3 underwent re-intervention (2 surgical, 1 endovascular). There were no deaths related to the procedure. Freedom from re-intervention and survival at 1/5 years was 93%/84% and 93%/67%, respectively. CONCLUSION: The Anaconda™ endograft limb for endovascular popliteal artery aneurysm repair offers good mid-term patency and acceptable long-term patency up to 4 years when compared with other grafts and open surgery. It may be considered in older comorbid patients unfit for surgery and can be performed percutaneously under local anaesthesia when anatomically feasible.


Asunto(s)
Aneurisma , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Arteria Poplítea , Humanos , Masculino , Anciano , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Stents , Aneurisma/diagnóstico por imagen , Aneurisma/cirugía , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Estudios Retrospectivos
3.
AJNR Am J Neuroradiol ; 42(8): 1464-1471, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34045301

RESUMEN

BACKGROUND: Balloon guide catheters are increasingly used to improve clot retrieval by temporarily stopping proximal blood flow during endovascular thrombectomy. PURPOSE: Our aim was to provide a summary of the literature comparing the procedural and clinical outcomes of endovascular thrombectomy with or without balloon guide catheters, depending on the first-line technique used. DATA SOURCES: We used PubMed/MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews. STUDY SELECTION: We chose studies that compared using balloon guide catheters with not using them. DATA ANALYSIS: Random effects meta-analysis was performed to compare the procedural outcomes measured as the first-pass effect, successful reperfusion, number of passes, procedural duration, arterial puncture to reperfusion time, distal emboli, and clinical outcomes. DATA SYNTHESIS: Overall, a meta-analysis of 16 studies (5507 patients, 50.8% treated with balloon guide catheters and 49.2% without them) shows that the use of balloon guide catheters increases the odds of achieving a first-pass effect (OR = 1.92; 95% CI, 1.34-2.76; P < .001), successful reperfusion (OR = 1.85; 95% CI, 1.42-2.40; P < .001), and good functional outcome (OR =1.48; 95% CI, 1.27-1.73; P < .001). Balloon guide catheters reduce the number of passes (mean difference = -0.35; 95% CI, -0.65 to -0.04; P = .02), procedural time (mean difference = -19.73; 95% CI, -34.63 to -4.83; P = .009), incidence of distal or new territory emboli (OR = 0.5; 95% CI, 0.26-0.98; P = .04), and mortality (OR = 0.72; 95% CI, 0.62-0.85; P < .001). Similar benefits of balloon guide catheters are observed when the first-line technique was a stent retriever or contact aspiration, but not for a combined approach. LIMITATIONS: The analysis was based on nonrandomized trials with a moderate risk of bias. CONCLUSIONS: Current literature suggests improved clinical and procedural outcomes associated with the use of balloon guide catheters during endovascular thrombectomy, especially when using the first-line stent retriever.


Asunto(s)
Isquemia Encefálica , Procedimientos Endovasculares , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/cirugía , Catéteres , Humanos , Stents , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...