Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Cancers (Basel) ; 13(24)2021 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-34944781

RESUMEN

Pancreatic ductal adenocarcinoma (PDAC) has an inauspicious prognosis, mainly due to difficulty in early detection of the disease by the current imaging modalities. The upcoming development of tumour-specific tracers provides an alternative solution for more accurate diagnostic imaging techniques for staging and therapy response monitoring. The future goal to strive for, in a patient with PDAC, should definitely be first to receive a diagnostic dose of an antibody labelled with a radionuclide and to subsequently receive a therapeutic dose of the same labelled antibody with curative intent. In the first part of this paper, we summarise the available evidence on tumour-targeted diagnostic tracers for molecular positron emission tomography (PET) imaging that have been tested in humans, together with their clinical indications. Tracers such as radiolabelled prostate-specific membrane antigen (PSMA)-in particular, 18F-labelled PSMA-already validated and successfully implemented in clinical practice for prostate cancer, also seem promising for PDAC. In the second part, we discuss the theranostic applications of these tumour-specific tracers. Although targeted radionuclide therapy is still in its infancy, lessons can already be learned from early publications focusing on dose fractioning and adding a radiosensitiser, such as gemcitabine.

2.
Medicina (Kaunas) ; 57(7)2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34356976

RESUMEN

Background and Objectives: Conduction disturbances such as left bundle branch block (LBBB) and complete atrio-ventricular block (cAVB) are relatively frequent complications following trans-catheter aortic valve implantation (TAVI). We investigated the dynamics of these conduction blocks to further understand luxating factors and predictors for their persistency. Materials and Methods: We prospectively included 157 consecutive patients who underwent a TAVI procedure. Electrocardiograms (ECGs) were obtained at specific time points during the TAVI procedure and at follow-up until at least six months post-procedure. Results: Of the 106 patients with a narrow QRS complex (nQRS) before TAVI, ~70% developed LBBB; 28 (26.4%) being classified as super-transient (ST-LBBB), 20 (18.9%) as transient (T-LBBB) and 24 (22.6%) as persistent (P-LBBB). Risk of LBBB was higher for self-expandable (SE) than for balloon-expandable (BE) prostheses and increased with larger implant depth. During the TAVI procedure conduction disturbances showed a dynamic behavior, as illustrated by alternating kinds of blocks in 18 cases. Most LBBBs developed during balloon aortic valvuloplasty (BAV) and at positioning and deployment of the TAVI prosthesis. The incidence of LBBB was not significantly different between patients who did and did not undergo BAV prior to TAVI implantation (65.3% and 74.2%, respectively (p = 0.494)). Progression to cAVB was most frequent for patients with preexisting conduction abnormalities (5/34) patients) and in patients showing ST-LBBB (6/28). Conclusions: During the TAVI procedure, conduction disturbances showed a dynamic behavior with alternating types of block in 18 cases. After a dynamic period of often alternating types of block, most BBBs are reversible while one third persist. Patients with ST-LBBB are most prone to progressing into cAVB. The observation that the incidence of developing LBBB after TAVI is similar with and without BAV suggests that a subgroup of patients has a substrate to develop LBBB regardless of the procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Electrocardiografía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Medicina (Kaunas) ; 57(5)2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-34064932

RESUMEN

Background and objectives: Persistent left bundle branch block (P-LBBB) has been associated with poor clinical outcomes of transcatheter aortic valve implantation (TAVI) procedures. We hypothesized that the distance from the aortic valve to the proximal conduction system, expressed as the effective distance between the aortic valve and conduction system (EDACS), can predict the occurrence of P-LBBB in patients undergoing a TAVI procedure. Materials and methods: In a retrospective study, data from 269 patients were analyzed. EDACS was determined using two longitudinal CT sections. Results: Sixty-four of the patients developed P-LBBB. EDACS ranged between -3 and +18 mm. EDACS was significantly smaller in P-LBBB than in non-P-LBBB patients (4.6 (2.2-7.1) vs. 8.0 (5.8-10.2) mm, median values (interquartile range); p < 0.05). Receiver operating characteristic analysis showed an area under the curve of 0.78 for predicting P-LBBB based on EDACS. In patients with EDACS of ≤3 mm and >10 mm, the chance of developing P-LBBB was ≥50% and <10%, respectively. Conclusions: A small EDACS increases the risk for the development of P-LBBB during TAVI by a factor of >25. As EDACS can be measured pre-procedurally, it may be a valuable additional factor to weigh the risks of transcatheter and surgical aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama , Electrocardiografía , Humanos , Incidencia , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
Eur J Heart Fail ; 19 Suppl 2: 84-91, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28470925

RESUMEN

INTRODUCTION/AIM: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) support is increasingly used in refractory cardiogenic shock and cardiac arrest, but is characterized by a rise in afterload of the left ventricle (LV) which may ultimately either further impair or delay cardiac contractility improvement. The aim of this study was to provide a comprehensive overview regarding the different LV venting techniques and results currently available in the literature. METHODS: A systematic literature search was performed in the PubMed database: 207 articles published between 1993 and 2016 were included. Papers dealing with pre-clinical studies, overlapping series, and association with other assist devices were excluded from the review, with 45 published papers finally selected. Heterogeneous indications for LV unloading were reported. The selected literature was divided into subgroups, according to the location or the performed procedure for LV venting. RESULTS: Case reports or case series accounted for 60% of the papers, while retrospective study represented 29% of them. Adult series were present in 67%, paediatric patients in 29%, and a mixed population in 4%. LV unloading was performed percutaneously in 84% of the cases. The most common locations of unloading was the left atrium (31%), followed by indirect unloading (intra-aortic balloon pump) (27%), trans-aortic (27%), LV (11%), and pulmonary artery (4%). Percutaneous trans-septal approach was reported in 22%. Finally, the unloading was conducted surgically in 16%,with open chest surgery in 71%, and minimally invasive surgery in 29% of surgical cases. CONCLUSION: Nowadays, only a few data are available about left heart unloading in V-A ECMO support. Despite the well-known controversy, IABP remains widely used in combination with V-A ECMO. Percutaneous approaches utilizing unloading devices is becoming an increasingly used option. However, further studies are required to establish the optimal LV unloading method.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Contrapulsador Intraaórtico/métodos , Choque Cardiogénico/terapia , Humanos
5.
J Electrocardiol ; 50(2): 261-267, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28126337

RESUMEN

BACKGROUND: The Selvester QRS score (S-score) estimates myocardial scar using electrocardiographic criteria. We evaluated the S-score for left bundle branch block (LBBB). MATERIAL AND METHODS: Studied were 36 patients who developed persistent LBBB upon transcatheter aortic valve implantation (TAVI, TAVI-LBBB group) and 36 matched patients with persistent narrow QRS (TAVI-nQRS group). Electrocardiograms were recorded before and briefly after TAVI and during ~6months follow-up. S-score was calculated using criteria for hypertrophic (in absence of LBBB) or LBBB hearts. RESULTS: In TAVI-LBBB patients correlation between S-scores pre-TAVI and post-TAVI was absent (R2=0.023). High S-scores post-TAVI occurred in patients with low pre-TAVI scores. Pre-post TAVI scores correlated weakly in TAVI-nQRS (R2=0.182), indicating a possible influence of ventricular unloading by TAVI. In both groups S-scores at post-TAVI and follow-up compared reasonably (R2=0.389 and R2=0.386), indicating reproducibility in more stable conditions. CONCLUSION: This study indicates that the use of the LBBB S-score criteria overestimates scar size and that caution is recommended in the use of the score in patients with LBBB.


Asunto(s)
Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Aturdimiento Miocárdico/diagnóstico , Aturdimiento Miocárdico/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Algoritmos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
6.
Europace ; 18(suppl 4): iv44-iv52, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28011830

RESUMEN

AIMS: Left bundle branch block (LBBB) is induced in approximately one-third of all transcatheter aortic valve implantation (TAVI) procedures. We investigated electrophysiological remodelling in patients with TAVI-induced LBBB. METHODS AND RESULTS: This retrospective study comprises 107 patients with initially narrow QRS complex of whom 40 did not and 67 did develop persistent LBBB after TAVI. 12-lead electrocardiograms (ECGs) taken before TAVI, within 24 hours ('acute'), and 1-12 months after TAVI ('chronic') were used to reconstruct vectorcardiograms. From these vectorcardiograms, QRS and T-wave area were calculated as comprehensive indices of depolarization and repolarization abnormalities, respectively. TAVI-induced LBBB resulted in significant acute depolarization and repolarization changes while further repolarization changes were observed with longer lasting LBBB. The amount of long-term repolarization changes (remodelling) was highly variable between patients. The change in T-wave area between acute and chronic LBBB ranged from +57% to - 77%. After dividing the LBBB cohort into tertiles based on the change in T-wave area, only baseline QRS area was larger in the tertile with no significant change in T-wave area. During longer lasting LBBB, the spatial vector gradient (SVG) changed orientation towards the direction of the QRS-vector, indicating that later-activated regions developed shorter action potential duration. CONCLUSION: This study in patients with TAVI-induced LBBB shows that repolarization changes develop within months after onset of LBBB, and that these changes are highly variable between individual patients.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Enfermedad Iatrogénica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Países Bajos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Vectorcardiografía
7.
Ann Thorac Surg ; 100(4): 1441-4, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26434440

RESUMEN

Bioprosthetic aortic valve thrombosis is a rare complication after transcatheter aortic valve implantation; however, one with a high mortality. We describe the case of a patient with a completely thrombosed transcatheter aortic valve prosthesis 9 months after implantation and review the diagnosis and management of this complication.


Asunto(s)
Válvula Aórtica , Enfermedades de las Válvulas Cardíacas/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Femenino , Humanos , Índice de Severidad de la Enfermedad , Factores de Tiempo
8.
Eur J Cardiothorac Surg ; 47(2): e47-53, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25473031

RESUMEN

OBJECTIVES: Recently, transcatheter aortic valve implantation has been introduced, but one of its complications is left bundle branch block (LBBB), a conduction disturbance that has been associated with increased mortality. We investigated the incidence and fate of both right bundle branch block (RBBB) and LBBB after aortic valve replacement (AVR) using a retrospective analysis. We also studied the predictive value of both disorders for all-cause mortality. METHODS: All patients who underwent AVR, with or without concomitant coronary artery bypass grafting surgery, between 2002 and 2010 in our centre were included. All-cause mortality was compared between patients who did and those who did not develop persistent new bundle branch block (BBB) within 7 days postoperatively. Patients were not eligible if one of their electrocardiogram (ECG) recordings prior to AVR showed a BBB or pacemaker activity. A postoperative period of 3-12 months was used to collect follow-up ECGs. RESULTS: Of the 2279 AVR patients, 2033 patients were eligible for analysis. After excluding patients lacking baseline or follow-up ECG (n = 269), 1764 patients remained for analysis. Early LBBB and RBBB occurred in 71 (4.0%) and 92 (5.2%) patients, respectively. At follow-up, LBBB was persistent in 29 patients (1.6%) and RBBB in 74 patients (4.2%). During a median follow-up of 4.5 (2.4-6.5) years, the mortality rate was 16.3% (n = 271) in patients without BBB, 24.1% (n = 7) in patients with persistent LBBB and 18.9% (n = 14) in patients with persistent RBBB (log-rank P = 0.49). Though, in univariate analysis, the hazard ratio for mortality was 1.54 and 1.10 for LBBB and RBBB, respectively, the small numbers precluded identifying AVR-induced LBBB and RBBB as a predictor of mortality. CONCLUSIONS: In the current practice of AVR, persistent postoperative LBBB and RBBB occur infrequently (∼ 5% of cases), a percentage less than half of that in current transcatheter aortic valve implantation procedures. Given the adverse effects of LBBB, the lower prevalence of procedure-induced LBBB in AVR should be taken into account while deciding which valve replacement procedure is chosen for a patient.


Asunto(s)
Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Bloqueo de Rama/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Anciano , Arritmias Cardíacas , Bloqueo de Rama/epidemiología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo
9.
Catheter Cardiovasc Interv ; 85(5): E144-52, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25504891

RESUMEN

OBJECTIVES: The aim of the study was to investigate trends over time in the occurrence of left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with the Medtronic CoreValve System (MCS) and Edwards SAPIEN Valve (ESV). BACKGROUND: TAVI-induced conduction abnormalities (TAVI-CAs) such as LBBB and the need for PPI are frequent postoperative complication. New techniques, procedural refinements, and increased awareness are focused on the reduction of these abnormalities. METHODS: Electrocardiograms of 549 patients without preprocedural LBBB and/or pacemaker were assessed to determine the frequency and nature of TAVI-CAs. To study the effect of experience, patients were subdivided per center into tertiles based on the number of procedures. Univariate and multivariate logistic regression was used to study predictors of TAVI-induced LBBB (TAVI-LBBB) and PPI. RESULTS: TAVI-LBBB occurred in 185 patients (33.7%) and significantly decreased over time, from 42.6% to 27.3% (P=0.006). This effect was only significant after implantation of the MCS (59.6% vs. 46.5% vs. 31.1%, P=0.001, ESV: 22.6% vs. 13.1% vs. 24.8%, P=0.11). Between tertiles there was no difference in the frequency of PPI after TAVI (n=73, 13.1% vs. 14.8% vs. 12%, P=0.74). Multivariate analysis revealed that, independent from valve type, depth of implantation was the only significant predictor of TAVI-LBBB (OR [95% C.I.]: 1.16 [1.10-1.24], P<0.001). In case of PPI pre-existing RBBB (OR [95% C.I.]: 7.22 [3.28-15.88], P<0.001) was the only significant predictor. CONCLUSIONS: Over time the frequency of LBBB after TAVI decreased significantly, especially in patients undergoing TAVI with the MCS. Experience and the subsequent reduction in depth of implantation seem responsible for this reduction. Contrary to TAVI-LBBB, the incidence of PPI remained unchanged over time and was not affected by experience. Although experience has led to a decrease in new CAs after TAVI, elucidation of pathophysiologic mechanisms underlying these CAs and subsequent changes in patient stratification, valve design and the procedure are needed to further reduce this complication.


Asunto(s)
Bloqueo de Rama/epidemiología , Marcapaso Artificial , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Incidencia , Masculino , Países Bajos/epidemiología , Quebec/epidemiología , Estudios Retrospectivos
10.
J Cardiovasc Transl Res ; 7(4): 395-405, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24800873

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an alternative treatment option for patients with severe aortic valve stenosis who do not qualify for surgical aortic valve replacement (AVR). Besides its proven clinical benefits, one of the complications of TAVI is the creation of conduction abnormalities, like left bundle branch block (LBBB). New LBBB occurs between 7 and 65% of cases, numbers that differ considerably between devices. In this review, we discuss the possible causes and the clinical significance of TAVI-induced LBBB. Several device- and procedural-related factors seem responsible for the development of LBBB, of which depth of implantation and balloon-annulus diameter ratio are the most important ones. TAVI-induced LBBB negatively affects cardiac function and hospitalization, but its impact on mortality is subject of debate. Future research and registries should implement strict diagnostic criteria for LBBB together with recording of its timing and persistence.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/fisiopatología , Bloqueo de Rama/etiología , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
11.
EuroIntervention ; 9(10): 1142-50, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24273252

RESUMEN

AIMS: Transcatheter aortic valve implantation (TAVI) is frequently complicated by new left bundle branch block (LBBB). We investigated the development and persistence of LBBB during follow-up and its clinical consequences. METHODS AND RESULTS: ECGs at baseline, within 24 hours, before discharge and at 12 months after TAVI were assessed in 476 patients without pre-existing LBBB and/or pacemaker before or after TAVI. TAVI-induced new LBBB was categorised based on the timing of the occurrence (within 24 hours [acute], after 24 hours but before discharge [subacute], and after discharge [late]), in addition to persistence (transient or persistent). A total of 175 patients (36.8%) developed new LBBB of which 85.7% occurred within 24 hours after TAVI, 12.0% before and 2.3% after hospital discharge, and was persistent in 111 patients (63.4%). Implantation of the Medtronic CoreValve System (MCS) more frequently led to new LBBB than the balloon-expandable Edwards SAPIEN valve (ES) (53.8% versus 21.7%) with less recovery during follow-up (39.0% versus 9.5%). Late new LBBB was only seen in four patients (0.8%). During a median follow-up of 915 (578-1,234) days, persistent LBBB was associated with a significant increase in mortality as compared to no LBBB and temporary LBBB combined (hazard ratio 1.49, 95% confidence interval, 1.10-2.03; p=0.01). CONCLUSIONS: TAVI-induced new LBBB occurs in almost 40% of patients, almost all before hospital discharge. It occurs three times more frequently after MCS than after ES valve implantation and has a twofold lower tendency to resolve during follow-up. Persistent LBBB is associated with a higher mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Electrocardiografía , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Incidencia , Masculino , Pronóstico , Estudios Prospectivos , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
12.
Circulation ; 126(6): 720-8, 2012 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-22791865

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a novel therapy for treatment of severe aortic stenosis. Although 30% to 50% of patients develop new left bundle-branch block (LBBB), its effect on clinical outcome is unclear. METHODS AND RESULTS: Data were collected in a multicenter registry encompassing TAVI patients from 2005 until 2010. The all-cause mortality rate at follow-up was compared between patients who did and did not develop new LBBB. Of 679 patients analyzed, 387 (57.0%) underwent TAVI with the Medtronic CoreValve System and 292 (43.0%) with the Edwards SAPIEN valve. A total of 233 patients (34.3%) developed new LBBB. Median follow-up was 449.5 (interquartile range, 174-834) days in patients with and 450 (interquartile range, 253-725) days in patients without LBBB (P=0.90). All-cause mortality was 37.8% (n=88) in patients with LBBB and 24.0% (n=107) in patients without LBBB (P=0.002). By multivariate regression analysis, independent predictors of all-cause mortality were TAVI-induced LBBB (hazard ratio [HR], 1.54; confidence interval [CI], 1.12-2.10), chronic obstructive lung disease (HR, 1.56; CI, 1.15-2.10), female sex (HR, 1.39; CI, 1.04-1.85), left ventricular ejection fraction ≤50% (HR, 1.38; CI, 1.02-1.86), and baseline creatinine (HR, 1.32; CI, 1.19-1.43). LBBB was more frequent after implantation of the Medtronic CoreValve System than after Edwards SAPIEN implantation (51.1% and 12.0%, respectively; P<0.001), but device type did not influence the mortality risk of TAVI-induced LBBB. CONCLUSIONS: All-cause mortality after TAVI is higher in patients who develop LBBB than in patients who do not. TAVI-induced LBBB is an independent predictor of mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/mortalidad , Bloqueo de Rama/cirugía , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Ensayos Clínicos como Asunto/tendencias , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...