J Nucl Med ; 56(12): 1948-53, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26449836

RESUMEN

UNLABELLED: We recently completed construction of a small-animal PET system-the MiniPET-3-that uses state-of-the-art silicon photomultiplier (SiPM) photosensors, making possible dual-modality imaging with MRI. In this article, we compare the MiniPET-3 with the MiniPET-2, a system with the same crystal geometry but conventional photomultiplier tubes (PMTs). METHODS: The standard measurements proposed by the National Electrical Manufacturers Association NU 4 protocols were performed on both systems. These measurements included spatial resolution, system sensitivity, energy resolution, counting rate performance, scatter fraction, spillover ratio for air and water, recovery coefficient, and image uniformity. The energy windows were set to 350-650 keV on the MiniPET-2 and 360-662 keV on the MiniPET-3. RESULTS: Spatial resolution was approximately 17% better on average for the MiniPET-3 than the MiniPET-2. The systems performed similarly in terms of peak absolute sensitivity (∼1.37%), spillover ratio for air (∼0.15), spillover ratio for water (∼0.25), and recovery coefficient (∼0.33, 0.59, 0.81, 0.89, and 0.94). Uniformity was 5.59% for the MiniPET-2 and 6.49% for the MiniPET-3. Minor differences were found in scatter fraction. With the ratlike phantom, the peak noise-equivalent counting rate was 14 kcps on the MiniPET-2 but 24 kcps on the MiniPET-3. However, with the mouselike phantom, these values were 55 and 91 kcps, respectively. The optimal coincidence time window was 6 ns for the MiniPET-2 and 8 ns for the MiniPET-3. CONCLUSION: Images obtained with the SiPM-based MiniPET-3 small-animal PET system are similar in quality to those obtained with the conventional PMT-based MiniPET-2.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/tendencias , Imagen Multimodal/métodos , Imagen Multimodal/tendencias , Tomografía de Emisión de Positrones/instrumentación , Tomografía de Emisión de Positrones/tendencias , Algoritmos , Animales , Radioisótopos de Flúor , Ratones , Fantasmas de Imagen , Ratas , Reproducibilidad de los Resultados , Células Fotorreceptoras Retinianas Bastones/diagnóstico por imagen , Radioisótopos de Sodio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...