Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39387741

RESUMEN

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) was introduced to treat ventricular tachycardia (VT) refractory to catheter ablation. No data are now available in the septal VT substrate setting, representing a challenge when using conventional techniques. OBJECTIVES: This study sought to evaluate the arrhythmic burden in patients with septal VT treated with magnetic resonance-guided STAR (MRgSTAR). METHODS: We enrolled consecutive patients with septal VT substrate. The therapy target was achieved by combining anatomic/functional and electrophysiologic information. Patients were treated with a single fraction of 25 Gy adopting MRgSTAR. All patients were clinically followed up, and all implantable cardiac devices were remotely monitored. The efficacy outcome included recurrences of any sustained VT beyond the 6-week blanking period after MRgSTAR. The safety outcome was the incidence of adverse events and atrioventricular block. RESULTS: We included 11 patients with septal substrate VT (median age: 68 years; Q1-Q3: 64.5-78 years; 100% male). Clinical presentation was an electrical storm in 81.8% of patients. No complications occurred after MRgSTAR, and 6 (54.5%) patients were discharged on the same day of treatment. During a mean follow-up of 12 ± 6 months, the efficacy outcome occurred in 3 (27.3%) cases. A significative reduction of implantable cardioverter-defibrillator (ICD) therapy (23.6 before MRgSTAR vs 1.7 after MRgSTAR; P < 0.001) was observed. Left ventricular ejection fraction increased significantly after treatment (38% [Q1-Q3: 33.5%-42.0%] before MRgSTAR vs 43.8% [Q1-Q3: 35%-47%] after MRgSTAR; P = 0.04). No adverse effects were observed in the implantable cardioverter-defibrillator and lead system; in the 7 patients with preserved atrioventricular conduction, no atrioventricular block was reported. CONCLUSIONS: MRgSTAR represents a safe and effective strategy for treating septal VT.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38811500

RESUMEN

OBJECTIVES: The aim of this study was to describe the correlation between atrial electrogram duration map (AEDUM), spatiotemporal electrogram dispersion (STED) and low voltage areas (LVA) in patients with persistent atrial fibrillation (PsAF). BACKGROUND: The degree of left atrial (LA) tissue remodelling and augmented anisotropic conduction is one of the major issues related to PsAF ablation outcome. METHODS: This study enrolled consecutive patients with PsAF undergoing pulmonary vein isolation. In all patients, voltage, AEDUM and STED maps were created, and the correlation was reported between these three mapping methods. RESULTS: A total of 40 patients with PsAF were enrolled. The mean age was 62.2 ± 7.4 years, and males were 72.5% (n = 29). The overall bipolar voltage of the LA was 3.06 ± 1.87 mV. All patients had at least one AEDUM area (overall AEDUM area: 21.8 ± 8.2 cm2); the mean longest electrogram (EGMs) duration was 90 ± 19 ms. STED areas with < 120 ms was 46.3 ± 20.2 cm2 which covered 45 ± 22% of the LA surface. AEDUM and STED areas were most frequently reported on the roof, the anterior wall and the septum. The extension of the AEDUM areas was significantly smaller than STED areas with CL < 120 ms (21.8 ± 8.2 vs 46.3 ± 20.2; p-value < 0.0001). In 24 patients (60%), AEDUM areas was entirely included in the STED areas with CL < 120 ms. In the three (7.5%) patients with LVA, no correspondence with STED and AEDUM was noted. CONCLUSION: AEDUM and STED maps allow to identify areas of conductive dysfunction as a possible atrial substrate even if a normal voltage is detected.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38814525

RESUMEN

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

5.
J Interv Card Electrophysiol ; 67(6): 1365-1376, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38206451

RESUMEN

BACKGROUND: Catheter ablation of persistent atrial fibrillation (PsAF) represents a challenge for the electrophysiologist and there are still divergences regarding the best ablative approach to adopt. Create a new map of the duration of atrial bipolar electrograms (Atrial Electrogram DUration Map, AEDUM) to recognize a functional substrate during sinus rhythm and guide a patient-tailored ablative strategy for PsAF. METHODS: Forty PsAF subjects were assigned in a 1:1 ratio to either for PVI alone (Group B1) or PVI+AEDUM areas ablation (Group B2). A cohort of 15 patients without AF history undergoing left-sided accessory pathway ablation was used as a control group (Group A). In all patients, voltage and AEDUM maps were created during sinus rhythm. The minimum follow-up was 12 months, with rhythm monitoring via 48-h ECG Holter or by implantable cardiac device. RESULTS: Electrogram (EGM) duration was higher in Group B than in Group A (49±16.2ms vs 34.2±3.8ms; p-value<0.001). In Group B the mean cumulative AEDUM area was 21.8±8.2cm2; no difference between the two subgroups was observed (22.3±9.1cm2 vs 21.2±7.2cm2; p-value=0.45). The overall bipolar voltage recorded inside the AEDUM areas was lower than in the remaining atrial areas [median: 1.30mV (IQR: 0.71-2.38mV) vs 1.54mV (IQR: 0.79-2.97mV); p-value: <0.001)]. Low voltage areas (<0.5mV) were recorded in three (7.5%) patients in Group B. During the follow-up [median 511 days (376-845days)] patients who underwent PVI-only experienced more AF recurrence than those receiving a tailored approach (65% vs 35%; p-value= 0.04). CONCLUSIONS: All PsAF patients exhibited AEDUM areas. An ablation approach targeting these areas resulted in a more effective strategy compared with PVI only.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Masculino , Femenino , Ablación por Catéter/métodos , Proyectos Piloto , Persona de Mediana Edad , Resultado del Tratamiento , Mapeo del Potencial de Superficie Corporal/métodos , Electrocardiografía Ambulatoria/métodos
6.
Heart Rhythm ; 21(8): 1267-1276, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38246567

RESUMEN

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Puntaje de Propensión , Humanos , Masculino , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Apéndice Atrial/cirugía , Anciano , Anticoagulantes/administración & dosificación , Anticoagulantes/uso terapéutico , Administración Oral , Medición de Riesgo/métodos , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Factores de Riesgo , Estudios de Seguimiento , Estudios Prospectivos , Incidencia , Resultado del Tratamiento , Tromboembolia/prevención & control , Tromboembolia/etiología , Tromboembolia/epidemiología , Anciano de 80 o más Años
7.
Artículo en Inglés | MEDLINE | ID: mdl-38040851

RESUMEN

BACKGROUND: Modified cardiac sympathetic denervation (CSD) with stellate ganglion (SG) sparing is a novel technique for cardiac neuromodulation in patients with refractory ventricular tachycardia (VT). OBJECTIVES: Our aim is to describe the mid- to long-term clinical outcome of the modified CSD with SG sparing in a series of patients with structural heart disease (SHD) and refractory VT. METHODS: All consecutive patients with SHD and refractory VT undergoing modified CSD were enrolled. Baseline clinical characteristics and periprocedural data were collected for all patients. The primary outcome was any recurrence of sustained VT. RESULTS: We enrolled 15 patients (age: 69.2 ± 7.9 years; male 100%) undergoing modified CSD. Left ventricular ejection fraction was 37 ± 11% and all patients had an implantable cardiac defibrillator (ICD); the underlying cardiomyopathy was non-ischemic in 73.3% of them. At least one previous ablation had been attempted in 66.6% of cases. The 73.3% of patients underwent bilateral CSD and the mean effective surgical time was 10.8 ± 2.4 min per side; no major periprocedural complication occurred. After a median follow-up time of 15 months (IQR: 8.5-24.5 months), the primary outcome occurred in 47.6% of cases. All patients experienced a reduction of ICD shocks after CSD (3.1 ICD shocks/patient before vs. 0.3 ICD shocks/patient after CSD; p-value: 0.001). Bilateral CSD and a VT cycle length < 340 ms were associated with better outcomes. CONCLUSIONS: A modified CSD approach with stellate ganglion sparing appears to be safe, fast, and effective in the treatment of patients with SHD and refractory VTs.

8.
Circ Arrhythm Electrophysiol ; 16(8): 447-455, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37485678

RESUMEN

BACKGROUND: The analysis of the wave-front activation patterns is crucial for the comprehension and treatment of ventricular tachycardia (VT). The ventricular electrograms duration map (VEDUM) is a potential method to identify areas (VEDUM area) with slow and inhomogeneous activation. There is no available data on the characteristics and the arrhythmogenic role of VEDUM areas identified during sinus/paced rhythm. METHODS: Patients referred for VT ablation were enrolled at 3 different centers. VEDUM maps during sinus/paced rhythm as well as substrate and functional maps were created; activation mapping was performed for all hemodynamically tolerated VT. RESULTS: Thirty-two patients (mean age:70.1±9.4 years; males 93.8%) were enrolled. The VEDUM approach was achieved in all patients and the mean size of the VEDUM area was 12.1±6.9 cm2 (interquartile range, 7.8-14.9 cm2). A significative difference was observed between the electrogram duration in the VEDUM area and the normal tissue (163.7 ms [interquartile range, 142.3-199.2 ms]; versus 65.5 ms [interquartile range, 59.5-76.2 ms]; P<0.001). The VEDUM area was visualized in a dense scar (<0.5 mV) in 19 (59.4%) patients. A deceleration zone and late potentials were recorded inside the VEDUM area in 56.3% and 81.3%, respectively. When a complete VT activation mapping was available, the isthmus projected in the VEDUM area in 93.5% of patients; 8 of them had multiple VTs mapped and in the 87.5% all VT isthmuses were included in the VEDUM area. CONCLUSIONS: VEDUM maps allow the identification of discrete areas of inhomogeneous and slow conduction. They represent a potential target for VT ablation, including patients with multiple morphologies.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Anciano , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas , Frecuencia Cardíaca/fisiología , Ablación por Catéter/métodos
10.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493490

RESUMEN

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Asunto(s)
Miocarditis , Sarcoidosis , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/epidemiología , Gadolinio , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética/efectos adversos , Miocarditis/complicaciones , Pronóstico , Medición de Riesgo , Factores de Riesgo , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda
11.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37378419

RESUMEN

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Asunto(s)
Vena Axilar , Incisión Venosa , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Vena Axilar/cirugía , Incisión Venosa/métodos , Vena Subclavia , Punciones/métodos , Corazón
12.
J Interv Card Electrophysiol ; 66(3): 647-660, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36178554

RESUMEN

BACKGROUND: Spatial differences in conduction velocity (CV) are critical for cardiac arrhythmias induction. We propose a method for an automated CV calculation to identify areas of slower conduction during cardiac arrhythmias and sinus rhythm. METHODS: Color-coded representations of the isochronal activation map using data coming from the RHYTHMIA™ Mapping System were reproduced by applying a temporal isochronal window at 20 ms. Geodesic distances of the 3D mesh were calculated using an algorithm selecting the minimum distance pathway (MDP). The CV estimation was performed considering points on the boundary of two spatially and temporally adjacent isochrones. For each of the boundary points of a given isochrone, the nearest boundary point of the consecutive isochrone was chosen, the MDP was evaluated, and a map of CV was created. The proposed method has been applied to a population of 29 patients. RESULTS: In all cases of perimitral atrial flutter (16 pts out of 29 (55%)), areas with significantly low CV (< 30 cm/s) were found. Half of the cases present regions with low CV located in the anterior wall. No case with low CV at the so-called LA isthmus was observed. Right atrial maps during common atrial flutters showed low CV areas mainly located in the inferior inter-atrial septum. No areas of low CV were observed in subjects without a history of atrial arrhythmia while pts affected by paroxysmal AF showed areas with a limited extension of low CV. CONCLUSIONS: The proposed software for automated CV estimation allows the identification of low CV areas, potentially helping electrophysiologists to plan the ablation strategy.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Sistema de Conducción Cardíaco , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Atrios Cardíacos/cirugía , Frecuencia Cardíaca/fisiología , Ablación por Catéter/métodos
13.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38225176

RESUMEN

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Estudios Transversales , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco , Ecocardiografía Transesofágica/métodos , Ecocardiografía/métodos
14.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38245007

RESUMEN

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Puntaje de Propensión , Resultado del Tratamiento , Atrios Cardíacos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
15.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36214206

RESUMEN

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Niño , Humanos , Desfibriladores Implantables/efectos adversos , Adolescente , Muerte Súbita Cardíaca/prevención & control
16.
J Clin Med ; 11(19)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36233407

RESUMEN

Background: Atrial fibrillation (AF) and heart failure (HF) often coexist and synergistically contribute to an increased risk of hospitalization, stroke, and mortality. Objective: To compare the efficacy of catheter ablation (CA) versus medical therapy (MT) in HF patients with AF. Methods: Electronic databases were queried for randomized controlled trials (RCTs) of CA versus MT of AF in patients with HF. Risk ratios (RRs), mean differences (MDs), and 95% confidence intervals (CIs) were measured using the Mantel−Haenszel method. Results: A total of nine RCTs enrolling 2155 patients met the inclusion criteria. Compared to MT, CA led to a significant reduction in the composite of all-cause mortality and HF hospitalization (24.6% vs. 37.1%; RR: 0.65 (95% CI: 0.53−0.80); p < 0.0001), all-cause mortality (8.8% vs. 13.6%; RR: 0.65 (95% CI: 0.51−0.82); p = 0.0005), HF hospitalization (15.4% vs. 22.4%; (RR: 0.67 (95% CI: 0.54−0.82); p = 0.0001), AF recurrence (31.8% vs. 77.0%; RR: 0.36 (95% CI: 0.24−0.54); p < 0.0001), and cardiovascular (CV) death (4.9% vs. 8.4%; RR: 0.58 (95% CI: 0.39−0.86); p = 0.007). CA improved the left ventricular ejection fraction (MD:4.76% (95% CI: 2.35−7.18); p = 0.0001), 6 min walk test (MD: 20.48 m (95% CI: 10.83−30.14); p < 0.0001), peak oxygen consumption (MD: 3.1 2mL/kg/min (95% CI: 1.01−5.22); p = 0.004), Minnesota Living with Heart Failure Questionnaire score (MD: −6.98 (95% CI: −12−03, −1.93); p = 0.007), and brain natriuretic peptide levels (MD:−133.94 pg/mL (95% CI: −197.33, −70.55); p < 0.0001). Conclusions: In HF patients, AF catheter ablation was superior to MT in reducing CV and all-cause mortality. Further significant benefits occurred within the ablation group in terms of HF hospitalizations, AF recurrences, the systolic function, exercise capacity, and quality of life.

17.
Artículo en Inglés | MEDLINE | ID: mdl-36282370

RESUMEN

Cardiac sympathetic denervation (CSD) is a valuable option in the setting of refractory ventricular arrhythmias in patient with structural heart disease. Since the procedure was introduced for non structural heart disease patients the techniques evolved and were modified to be adopted in several settings. In this state-of-the-art article we revised different techniques, their rationale, strengths, and pitfalls.

19.
J Interv Card Electrophysiol ; 64(3): 759-760, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35246770

RESUMEN

A patient with symptomatic persistent atrial fibrillation and recurrences after pulmonary vein isolation (PVI) underwent a second ablation procedure. The PVs were found isolated and the left atrial substrate tissue was mapped. During sinus rhythm, the voltage map resulted in a normal range (>0,5mV) while a map of EGMs durations revealed an area presenting prolonged EGMs (>45 ms) in the anterior region. The activation map of this area demonstrated abnormal conduction and a non-uniform anisotropism when compared with areas in which EGM's normal durations were recorded. The EGMs duration map may offer additional clinical information on the areas presenting abnormal conduction predisposing arrhythmias maintenance in patients suffering from persistent atrial fibrillation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento
20.
J Interv Card Electrophysiol ; 64(1): 173-182, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35175492

RESUMEN

BACKGROUND: Radiofrequency (RF) lesion creation is related to the heat propagation induced by RF application on tissues. Thermocouple embedded in the RF antenna are not able to predict deep tissue temperature at various level. OBJECTIVES: This study aims to investigate the influence of power delivered on radiofrequency catheter ablation (RFCA) effects by means of high resolved 2D temperature maps. METHODS: Three trials of four ablations (12 applications) were executed on each specimen of healthy excised swine myocardium in different application points at four RF power values (30 W, 40 W, 50 W, and 60 W) for a fixed treatment time. All the data provided by the fiber Bragg gratings (FBGs) were analyzed. Temperature variations (ΔT) in time recorded in the 28 sites of measurements were reported. Also, temperature maps showing the ΔT spatial distribution reached within the tissue at the end of the RFCA were produced and displayed, together with the representation of the lethal isotherm. Moreover, the time of achievement of the lethal isotherm at different tissue depths (from 1 to 8 mm) was evaluated for the four power settings. RESULTS: Temperature trends reported comparable profiles across the different power settings. ΔT values and ΔT rising times showed dependence on the sensors' proximity to the RF energy source and on the set RF power. Temperature maps confirmed that heat propagation occurs preferentially along the width of the tissue than in the depth. Also, for the adjusted treatment time, no power setting guarantees lesions thicker than 6 mm. CONCLUSIONS: ΔT maximal values and ΔT rising time strongly depends on the proximity of the tissues to RF energy source, as well as on the RF power setting. A plateau is reached in lesion size, regardless of the power setting. A first correlation between lesion size, power setting, and time to achieve lethal isotherms has been established.


Asunto(s)
Ablación por Catéter , Calor , Animales , Humanos , Miocardio/patología , Porcinos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...