Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Dent Mater J ; 42(6): 835-843, 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-37880135

RESUMEN

This study investigated the influence of different surface treatments on unfiring or firing zirconia-reinforced lithium silicate (ZLS) glass-ceramics. Celtra Duo and IPS e.max CAD blocks were cut and process following manufacturer protocols. The specimen surface was treated with seven different protocols. Two ceramic blocks with the same surface treatment were bonded with luting agent and prepared for mini-interfacial fracture toughness tests (mini-iFT). The specimens were tested after 1-week storage. The data was statistically analyzed using two-way ANOVA and Dunnett's T3 comparison (α=0.05). The highest mini-iFT of both Celtra Duo unfired and fired was shown in the HF+S group, which was not significantly different from HF+S+UA. For IPS e.max CAD, the mini-iFT was higher in the groups treated with hydrofluoric acid. Additional adhesive after silane application did not significantly improve bonding effectiveness. Therefore, surface treatment with hydrofluoric acid and silane is recommended for both unfiring and firing ZLS glass ceramics.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Litio , Silanos , Ácido Fluorhídrico , Propiedades de Superficie , Cerámica , Silicatos , Ensayo de Materiales , Diseño Asistido por Computadora
2.
J Prosthodont Res ; 67(4): 603-609, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36792222

RESUMEN

PURPOSE: To determine whether the fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) resin-based composites and polymer-infiltrated ceramic network materials cemented on dentin is influenced by the restoration thickness and composite cement application strategy. METHODS: Disc-shaped specimens (Ø = 7 mm) of 0.8 mm and 1.5 mm thicknesses were milled from two CAD/CAM materials: resin-based composite (RBC, Cerasmart 270) and polymer-infiltrated ceramic network (PICN, Vita Enamic). The discs (n = 8 per group) were cemented on flattened dentin using three different cementation strategies: 1) self-adhesive composite cement (RelyX U200) in light-curing mode (LC-SAC), 2) universal adhesive (Single Bond Universal) with composite cement (RelyX Ultimate) in auto-curing mode (AC cement), and 3) adhesive and composite cement as in 2) but in light-curing mode (LC cement). The restorative surface was indented perpendicularly with a compressive load using a universal testing machine until fracture. The fracture resistance (N) of RBC and PICN was separately analyzed using two-way ANOVA and Tukey's post-hoc test (α = 0.05). RESULTS: The fracture resistance of each material was significantly influenced by the material thickness and cementation strategy (P < 0.05). Irrespective of the material type and cementation strategy, thicker materials exhibit higher fracture resistance. For RBC, the fracture resistance of the LC cement group was significantly higher than that of AC cement only at 0.8 mm thickness. For PICN, the LC-cement cementation strategy produced superior fracture resistance, regardless of the restoration thickness. CONCLUSIONS: The fracture resistance of Cerasmart 270 was higher for the thicker material; the fracture resistance of LC cement was higher than that of AC cement at 0.8 mm thickness cemented to dentin. In comparison, LC cement showed the highest fracture resistance for Vita Enamic for both material thicknesses.

3.
Eur J Dent ; 17(4): 1120-1128, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36812931

RESUMEN

OBJECTIVE: To evaluate the potential of modified bioactive glasses containing lithium and zinc as pulp capping materials by investigating the odontogenic differentiation and mineralization response in the tooth culture model. MATERIALS AND METHODS: Lithium- and zinc-containing bioactive glasses (45S5.1Li, 45S5.5Li, 45S5.1Zn, 45S5.5Zn, 45S5.1Zn sol-gel, and 45S5.5Zn sol-gel), fibrinogen-thrombin, and biodentine were prepared to assess Axin2 gene expression at 0, 30 minutes, 1 hour, 12 hours, and 1 day and DSPP gene expression at 0, 3, 7, and 14 days in stem cells from human exfoliated deciduous teeth (SHEDs) using qRT-PCR. The experimental bioactive glasses incorporated with fibrinogen-thrombin and biodentine were placed on the pulpal tissue in the tooth culture model. Histology and immunohistochemistry were analyzed at 2 weeks and 4 weeks. RESULTS: Axin2 gene expression for all experimental groups was significantly higher than the control at 12 hours. The DSPP gene expression for all experimental groups was significantly higher than the control at 14 days. The presence of mineralization foci was significantly higher at 4 weeks for the modified bioactive glasses 45S5.5Zn, 45S5.1Zn sol-gel, and 45S5.5Zn sol-gel as well as Biodentine compared with the fibrinogen-thrombin control. CONCLUSION: Lithium- and zinc-containing bioactive glasses increased Axin2 and DSPP gene expression in SHEDs and can potentially enhance pulp mineralization and regeneration. Zinc-containing bioactive glasses are a promising candidate to be used as pulp capping materials.

4.
Int J Dent ; 2022: 8048265, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35449763

RESUMEN

Objectives: This retrospective study evaluated the factors influencing the clinical failure of noncarious cervical lesion (NCCL) restorations. Methods: Patients were routinely treated by undergraduate or postgraduate students and randomly received a clinical recall evaluation. A retrospective study was performed with two experienced calibrated examiners to evaluate NCCL restorations, including the critical parameters of retention, caries, marginal discoloration, and marginal integrity. The factors related to the restoration included gender, age, arch site, tooth position, the presence of occlusal wear facets, caries risk, operator, adhesive strategy, and composite. The clinical failure comparison between the parameters and factors was performed using the binary logistic regression analysis. Results: A total of 460 cervical restorations from 96 patients were evaluated. The adhesive strategy and the presence of occlusal wear facets were the most important factors influencing the parameter failure. Therefore, the highest failure was marginal integrity, in which the gingival marginal integrity failure was 50.7%, and the occlusal marginal integrity failure was 42.4%. Conclusions: The main factors influencing clinical failure for partial loss, marginal discoloration, and marginal integrity were the adhesive strategy and the presence of occlusal wear facets. Therefore, marginal integrity was the most frequent failure parameter.

5.
J Mech Behav Biomed Mater ; 126: 105015, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34896766

RESUMEN

OBJECTIVES: To evaluate the effect of post-treatment autoclaving on monomer elution and mechanical properties of three-dimensionally (3D) printed resin for splint fabrication. METHODS: Photopolymer resin specimens (Dental LT Clear) were 3D-printed and processed according to the manufacturer's instructions. The specimens were randomly divided to different post-treatment protocols: water storage, autoclaving at different temperatures (121 °C or 132 °C), times (4 or 30 min) and no treatment as a control. The elution of UDMA, HEMA, and EGDMA monomers was determined using high-performance liquid chromatography (HPLC) by immersing the specimens in 75% ethanol for 72 h. The flexural modulus, surface microhardness and linear dimensional changes were measured. The monomer elution and flexural modulus were statistically analyzed using Welch's ANOVA followed by Dunnett's T3 tests, while the surface microhardness and dimensional changes were analyzed using one-way ANOVA followed by Bonferroni tests (α = 0.05). RESULTS: The overall monomer elution concentrations were significantly highest for the control group and lowest for specimens treated in an autoclave at 132 °C for 4 min. The flexural modulus was not significantly different between all groups. The surface microhardness was significantly higher for all autoclaved groups than the control and water storage groups. The linear expansion was significantly higher after post-treatment autoclaving in contrast to water storage. SIGNIFICANCE/CONCLUSIONS: Post-polymerization autoclave treatment of the 3D-printed resin reduced monomer elution and improved surface microhardness without deteriorating the flexural modulus. Post-treatment with an autoclave at 132 °C for 4 min can be recommended for 3D-printed resin for splint fabrication.


Asunto(s)
Resinas Acrílicas , Férulas (Fijadores) , Materiales Dentales , Ensayo de Materiales , Polimerizacion , Impresión Tridimensional , Propiedades de Superficie
6.
Dent Mater J ; 40(5): 1169-1176, 2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34078777

RESUMEN

This study was to evaluate the acid-buffering capacity and antibacterial properties of orthodontic adhesives containing bioactive glasses (BAGs) (45S5, 45S5F, S53P4), Hydroxyapatite, beta-tricalcium phosphate, and Canasite. Fillers comprising 15 wt% bioactive glasses, HAp, ß-TCP, and Canasite incorporated with 55 wt% silanated glass were added to a mixture of UDMA/TEGDMA. Acid-buffering capacity was tested by exposing disc-shaped samples of each adhesive to medium of bacteria-produced acids, and pH changes were recorded at 24 and 48 h. Antibacterial properties were assessed by indirect testing by exposing polymerized adhesive samples to a medium and direct testing by immersing the specimens in solutions containing S. mutans and S. sanguinis. A significant buffering capacity was shown by the 45S5, 45S5F and S53P4 BAG adhesives. The antibacterial properties were not significant in all experimental adhesives. Therefore, the experimental orthodontic adhesives containing BAGs demonstrated a significant buffering capacity but did not show significant antibacterial properties against S. mutans and S. sanguinis.


Asunto(s)
Cementos Dentales , Vidrio , Antibacterianos/farmacología , Cementos Dentales/farmacología
7.
J Adv Prosthodont ; 11(5): 253-261, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31754415

RESUMEN

PURPOSE: To evaluate the influence of cyclic loading on phase transformation of zirconia abutments and to compare the effectiveness of three different quantitative ageing assessment techniques. MATERIALS AND METHODS: Thirty two Y-TZP prostheses fabricated from two brands, InCoris ZI and Ceramill ZI, were cemented to titanium bases and equally divided into two subgroups (n=8): control group without any treatment and aged group with cyclic loading between 20 N and 98 N for 100,000 cycles at 4 Hz in distilled water at 37℃. The tetragonal-to-monoclinic phase transformation was assessed by (i) conventional x-ray diffraction (XRD), (ii) micro x-ray diffraction (µXRD), and (iii) micro-Raman spectroscopy. The monoclinic-phase fractions (M%) were compared by two-way ANOVA. RESULTS: InCoris Zi presented significantly higher M% than Ceramill Zi in both control and aged groups (P<.001). Both materials exhibited significant phase transformation with monoclinicphase of 1 to 3% more in aged groups than controls for all thre e assessment techniques. The comparable M% was quantified by both µXRD and XRD. The highest M% was assessed with micro-Raman. CONCLUSION: Cyclic loading produced significant phase transformation in tested Y-TZP prostheses. The micro-Raman spectroscopy could be used as an alternative to XRD and µXRD.

8.
Dent Mater ; 34(4): 684-692, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29422325

RESUMEN

OBJECTIVE: To evaluate the effect of the kind and concentration of photo-initiator on the degree of conversion (DC) of adhesives on dentin/glass substrates and their mini-interfacial fracture toughness (mini-iFT) to dentin. METHODS: We tested the adhesive Clearfil S3 Bond Plus and 4 derived experimental 'LUB' ('Leuven Univesity Bond') adhesives (all from Kuraray Noritake), namely 'LUB-CQ/amine_high', 'LUB-CQ/amine_low', 'LUB-TPO_high', and 'LUB-TPO_low', respectively containing 2.0wt% camphorquinone (CQ) and 2.0wt% EDMAB (amine), 0.35wt% CQ and 0.35wt% amine, 2.0wt% TPO, and 0.35wt% TPO. For DC, each adhesive was applied onto glass or dentin prior to being cured (Bluephase 20i; Ivoclar Vivadent: "high mode") for 10s. DC was measured at 5min, 10min, 1h, 24h and 1 week using micro-Raman spectroscopy (SENTERRA; BrukerOptik). For mini-iFT, each adhesive was bonded to 320-grit SiC-paper ground dentin and covered with composite (Z100; 3M ESPE). The restored teeth were cut in sticks (1.5×2.0×16mm), after which a single-gradient notch was prepared at the adhesive-dentin interface using a 150-µm diamond blade. The micro-specimens were loaded until failure in a 4-point bending test and the mini-iFT in term of KQvM was calculated. RESULTS: DC was higher on dentin than on glass. All adhesives were adequately polymerized at 1 week, except for LUB-TPO_low. DC at 5min was significantly higher for LUB-TPO_high than for both CQ/amine-based adhesives. The highest and most reliable mini-iFT was measured for LUB-CQ/amine_high, despite its 5-min DC was relatively low. No correlation between DC and mini-iFT was found. SIGNIFICANCE: Curing of TPO-based adhesives is faster, but the dark cure of the CQ/amine-containing adhesives is more efficient. The differences in curing profiles do affect the mechanical properties of the resultant interfaces at dentin.


Asunto(s)
Recubrimientos Dentinarios/química , Fotoiniciadores Dentales/química , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Técnicas In Vitro , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Tercer Molar , Polimerizacion , Cementos de Resina , Propiedades de Superficie
9.
J Adhes Dent ; 19(5): 409-416, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28944377

RESUMEN

PURPOSE: To investigate the bonding efficacy of a multimode adhesive to plasma-treated and -untreated (control) dentin using a mini-interfacial fracture toughness (mini-iFT) test. MATERIALS AND METHODS: Twenty human molars were used in a split-tooth design (n = 10). The adhesive Scotchbond Universal (SBU; 3M ESPE) was applied in etch-and-rinse (E&R) and self-etch (SE) modes. Mid-coronal dentin was exposed and covered with a standardized smear layer ground to 320 grit. One half of each dentin surface received 15 s of non-thermal atmospheric plasma (NTAP), while the other half was covered with a metallic barrier and kept untreated. Following the E&R mode, dentin was plasma treated immediately after phosphoric acid etching. SBU and a resin-based composite were applied to dentin following the manufacturer's instructions. Six mini-iFT specimens were prepared per tooth (1.5 x 2.0 x 16 to 18 mm), and a single notch was prepared at the adhesive-dentin interface using a 150-µm diamond blade under water cooling. Half of the mini-iFT specimens were immediately loaded until failure in a 4-point bending test, while the other half were first stored in distilled water for 6 months. After testing, the exact dimensions of the notch were measured with a measuring optical microscope, from which ΚIc was determined. RESULTS: Three-way ANOVA revealed higher mini-iFT for SBU applied in E&R than SE mode for both storage times, irrespective of NTAP treatment. CONCLUSION: Overall, mini-iFT did not decrease for any of the experimental groups upon 6-month aging, while plasma treatment did not show a direct beneficial effect on mini-iFT of SBU applied in either E&R or SE mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Resinas Compuestas , Cementos Dentales , Dentina , Humanos , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción
10.
J Adhes Dent ; 19(2): 157-167, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28439575

RESUMEN

PURPOSE: To evaluate the effect of the type and concentration of photo-initiator on the long-term bonding efficacy to dentin in terms of mini-interfacial fracture toughness (mini-iFT). MATERIALS AND METHODS: The bonding efficacy of the one-step self-etch (SE) adhesive Clearfil S3 Bond Plus and four derivative experimental adhesives (Leuven University Bond [LUB]), which were similar in composition except for the (co)photo-initiators (all prepared by Kuraray Noritake), containing 2.0 wt% camphorquinone (CQ) and 2.0 wt% EDMAB (LUB-CQ/amine_high), 0.35 wt% CQ and 0.35 wt% EDMAB (LUB-CQ/amine_low ), 2.0 wt% TPO (LUB-TPO_high), and 0.35 wt% TPO (LUB-TPO_low), was measured using a mini-iFT approach after being aged for 6 months and 1 year by water storage at 37°C (control: 1 week mini-iFT). The mini-iFT specimens were loaded until failure in a 4-point bending device to determine the interfacial fracture toughness (KIc). All fractured specimens were evaluated using scanning electron microscopy (SEM). RESULTS: The mini-iFT of Clearfil S3 Bond Plus and the adhesives with high photo-initiator concentrations was not significantly different at 6 months, although it dropped significantly at 1 year. For each storage period, the mini-iFT of the adhesives with high photo-initiator concentrations was not significantly different from that of the commercial adhesive, in contrast to the significantly lower mini-iFT measured for adhesives with low concentrations of photo-initiator. SEM fracture analysis revealed that the adhesives with high concentrations of photo-initiator most frequently failed at the top of the hybrid layer at 1 week, while this failure pattern shifted to the bottom of the hybrid layer after aging. CONCLUSION: A one-step self-etch adhesive should contain photo-initiator in a sufficiently high concentration, as this directly improves its immediate and long-term bonding efficacy to dentin. While the mini-iFT remained stable up to 6 month of aging for both the commercial and the adhesive with a high concentration of photo-initiator, the mini-iFT was found to decrease after 1 year of aging.


Asunto(s)
Recubrimiento Dental Adhesivo , Polimerizacion , Cementos Dentales , Dentina , Recubrimientos Dentinarios , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción
11.
Clin Oral Investig ; 21(3): 895-905, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27153848

RESUMEN

OBJECTIVES: This study aims to investigate the effect of modifying tricalcium silicate (TCS) cements on three key properties by adding ZrO2. MATERIALS AND METHODS: TCS powders were prepared by adding ZrO2 at six different concentrations. The powders were mixed with 1 M CaCl2 solution at a 3:1 weight ratio. Biodentine (contains 5 wt.% ZrO2) served as control. To evaluate the potential effect on mechanical properties, the mini-fracture toughness (mini-FT) was measured. Regarding bioactivity, Ca release was assessed using ICP-AES. The component distribution within the cement matrix was evaluated by Feg-SEM/EPMA. Cytotoxicity was assessed using an XTT assay. RESULTS: Adding ZrO2 to TCS did not alter the mini-FT (p = 0.52), which remained in range of that of Biodentine (p = 0.31). Ca release from TSC cements was slightly lower than that from Biodentine at 1 day (p > 0.05). After 1 week, Ca release from TCS 30 and TCS 50 increased to a level that was significantly higher than that from Biodentine (p < 0.05). After 1 month, Ca release all decreased (p < 0.05), yet TCS 0 and TCS 50 released comparable amounts of Ca as at 1 day (p > 0.05). EPMA revealed a more even distribution of ZrO2 within the TCS cements. Particles with an un-reacted core were surrounded by a hydration zone. The 24-, 48-, and 72-h extracts of TCS 50 were the least cytotoxic. CONCLUSIONS: ZrO2 can be added to TCS without affecting the mini-FT; Ca release was reduced initially, to reach a prolonged release thereafter; adding ZrO2 made TCS cements more biocompatible. CLINICAL RELEVANCE: TCS 50 is a promising cement formulation to serve as a biocompatible hydraulic calcium silicate cement.


Asunto(s)
Compuestos de Calcio/química , Cementos Dentales/química , Silicatos/química , Circonio/química , Materiales Biocompatibles , Ensayo de Materiales
12.
Clin Oral Investig ; 21(4): 1201-1212, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27383375

RESUMEN

OBJECTIVES: The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. MATERIALS AND METHODS: Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (α = 0.05). RESULTS: DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. CONCLUSIONS: Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. CLINICAL RELEVANCE: Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Dureza , Pruebas de Dureza , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Polimerizacion , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie
13.
Dent Mater ; 32(12): 1575-1585, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27771139

RESUMEN

OBJECTIVES: To determine the interfacial fracture toughness (iFT) and micro-tensile strength (µTBS) of composite cements bonded to dentin. METHODS: Fifty feldspar ceramic blocks (Vita Mark II, Vita Zahnfabrik) were luted onto dentin using two self-adhesive (G-CEM LinkAce, GC; SpeedCEM, Ivoclar Vivadent), two self-etch (Multilink Primer & Multilink Automix, Ivoclar Vivadent; Scotchbond Universal & RelyX Ultimate, 3 M ESPE), and one etch-and-rinse (Excite F DSC & Variolink II, Ivoclar Vivadent) composite cement (n=10). After 48h in 100% relative humidity at 37°C, one half of each tooth was sectioned in sticks with a chevron notch at the cement-dentin interface and tested in a 4-point bending test setup (iFT). The remaining half of the tooth was sectioned in micro-specimens and stressed in tension until failure (µTBS). The mode of failure was determined with a stereomicroscope at 50× magnification. Data were submitted to Weibull analysis and Pearson's correlation (α=0.05). RESULTS: At 10% probability of failure, no significant differences could be found using iFT, while the etch-and-rinse composite cement Variolink II presented a significantly higher µTBS at this level. At 63.2% probability of failure, the self-adhesive composite cement G-CEM LinkAce revealed a significantly lower µTBS and iFT, and the self-etch cement Multilink Automix also revealed a significantly lower µTBS than all other cements. The correlation found between iFT and µTBS was moderate and not significant (r2=0.618, p=0.11). SIGNIFICANCE: Overall, the etch-and-rinse and 'universal' self-etch composite cements performed best. The micro-tensile bond strength and interfacial fracture toughness tests did not correlate well.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Cementos de Resina , Resinas Compuestas , Análisis del Estrés Dental , Ensayo de Materiales , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
14.
J Mech Behav Biomed Mater ; 62: 446-455, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27281162

RESUMEN

UNLABELLED: Today׳s most commonly applied bonding effectiveness tests are criticized for their high variability and low reliability, the latter in particular with regard to measuring the actual strength of the adhesive interface. OBJECTIVES: in continuation of previous research conducted at dentin, we hereby aimed to validate the novel mini-interfacial fracture toughness (mini-iFT) test on its applicability to assess bonding effectiveness of contemporary adhesives when bonded to enamel. METHODS: The 3-step etch&rinse (E&R) adhesive OptiBond FL (Kerr), the 2-step self-etch (SE) adhesive Clearfil SE Bond (Kuraray Noritake) and the two multi-mode adhesives Clearfil S(3) Bond Plus (Kuraray Noritake) and Scotchbond Universal (3M ESPE), both used following a 2-step E&R and 1-step SE mode, were applied to clinically relevant, flattened enamel surfaces. A composite (Filtek Z100; 3M ESPE) build-up was made in layers. After 1-week water storage at 37°C, all specimens were sectioned perpendicular to the interface to obtain rectangular sticks. A mini-iFT notch was prepared at the adhesive-enamel interface using a thin diamond blade under water cooling. Finally, the specimens were loaded in a 4-point bending test until failure. RESULTS: the mini-iFT onto human enamel was significantly higher for the adhesives applied in E&R mode versus those applied in SE mode. The lowest mini-iFT was found for the adhesives applied following a 1-step SE approach. SEM fracture analysis revealed that all fractures originated at the adhesive-enamel interface and that the induced crack propagated preferentially along this interface. CONCLUSION: mini-iFT appeared a valid alternative method to assess the mechanical properties of adhesive-enamel interfaces.


Asunto(s)
Recubrimiento Dental Adhesivo , Esmalte Dental , Análisis del Estrés Dental , Recubrimientos Dentinarios , Cementos de Resina , Resinas Compuestas , Dentina , Humanos , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Resistencia a la Tracción
15.
Dent Mater J ; 35(3): 360-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27251990

RESUMEN

The objective was to compare bond strengths of adhesives with/without thermocycling and to analyze the micromorphology of resindentin interfaces. Flat dentin surfaces were prepared and divided into eight groups to bond with four etch-and-rinse adhesives (Optibond FL, Adper Scotchbond Multi-Purpose, Optibond Solo Plus, and Single Bond 2) and four self-etch adhesives (Clearfil SE Bond, Adper SE Plus, Clearfil S(3) Bond and Adper Easy Bond). Specimens were further divided into two subgroups subjected for with/without thermocycling and then subjected to both micro-tensile test and resin-dentin interface evaluation. The results revealed that there were significant differences in bond strength between the groups with and without thermocycling for all etch-and-rinse groups and for the Adper Easy Bond self-etch group (p<0.01). Clearfil SE Bond demonstrated highly durable bond strengths. Furthermore, more silver ion uptake was observed at the resin-dentin interfaces for all etch-and-rinse adhesives and Adper SE Plus and Adper Easy Bond after thermocycling.


Asunto(s)
Cementos Dentales , Recubrimientos Dentinarios , Dentina , Resinas Compuestas , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
16.
J Adhes Dent ; 18(2): 161-71, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27022645

RESUMEN

PURPOSE: To assess the light irradiance (LI) delivered by two light-curing units and to measure the degree of conversion (DC) of three composite cements and one flowable composite when cured through zirconia or ceramic-veneered zirconia plates with different thicknesses. MATERIALS AND METHODS: Three dual-curing composite cements (Clearfil Esthetic Cement, Panavia F2.0, G-CEM LinkAce) and one light-curing flowable composite (G-aenial Universal Flo) were investigated. Nine different kinds of zirconia plates were prepared from three zirconia grades (YSZ: Aadva and KATANA; Ce-TZP/Al2O3: NANOZR) in three different thicknesses (0.5- and 1.5-mm-thick zirconia, and 0.5-mm-thick zirconia veneered with a 1.0-mm-thick veneering ceramic). Portions of the mixed composite cements and the flowable composite were placed on a light spectrometer to measure LI while being light cured through the zirconia plates for 40 s using two light-curing units (n = 5). After light curing, micro-Raman spectra of the composite films were acquired to determine DC at 5 and 10 min, 1 and 24 h, and at 1 week. RESULTS: The zirconia grade and the thickness of the zirconia/veneered zirconia plates significantly decreased LI. Increased LI did not increase DC. Only the Ce-TZP/Al2O3 (NANOZR) zirconia was too opaque to allow sufficient light transmission and resulted in significantly lower DC. CONCLUSION: Although zirconia-based restorations attenuate the LI of light-curing units, the composite cements and the flowable composite could be light cured through the YSZ zirconia. LI is too low through Ce-TZP/Al2O3 zirconia, necessitating the use of self-/dual-curing composite cements.


Asunto(s)
Resinas Compuestas/efectos de la radiación , Materiales Dentales/efectos de la radiación , Luz , Cementos de Resina/efectos de la radiación , Circonio/química , Óxido de Aluminio/química , Cerámica/química , Cerámica/efectos de la radiación , Cerio/química , Resinas Compuestas/química , Luces de Curación Dental/clasificación , Materiales Dentales/química , Coronas con Frente Estético , Humanos , Curación por Luz de Adhesivos Dentales/instrumentación , Ensayo de Materiales , Metacrilatos/química , Microespectrofotometría , Polietilenglicoles/química , Polimerizacion , Ácidos Polimetacrílicos/química , Poliuretanos/química , Dosis de Radiación , Cementos de Resina/química , Dispersión de Radiación , Espectrometría Raman , Propiedades de Superficie , Itrio/química
17.
Dent Mater ; 32(2): 183-91, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26743968

RESUMEN

OBJECTIVE: To study the effect of a low-shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on color, translucency, and color stability of model resin-based composites (RBCs). METHODS: Four micro-hybrid RBCs were prepared containing barium-glass fillers in bisphenol A-glycidyl-methacrylate (BisGMA) and triethyleneglycol-dimethacrylate (TEGDMA) or urethane-based low-shrinkage monomer FIT-852 (FIT; Esstech Inc.) and TEGDMA matrix. Camphorquinone (CQ)/amine or Lucirin TPO were used as photoinitiators. Commercial low-shrinkage RBCs (Charisma Diamond, Heraeus Kulzer and N'Durance, Septodont) and conventional RBCs (Tetric EvoCeram, Ivoclar Vivadent and Filtek Z250, 3M ESPE) were used as controls. Color and translucency were measured using Thermo Scientific Evolution (Thermo Fisher Scientific) and SpectroShade™ Micro (MHT Optic Research) spectrophotometers. Color stability was evaluated after immersion in black tea (pure, with milk or lemon) and distilled water. Data were analyzed using analyses of variance with Tukey's post-test (α=0.05). RESULTS: Photoinitiators had no significant effect on baseline color. Initially whiter FIT-based RBCs showed greater staining in all staining solutions than BisGMA-based RBCs. TPO-containing RBCs showed better color stability than CQ-containing RBCs irrespective of the base monomer. Tea and tea with lemon induced greatest color changes. Adding milk to tea significantly reduced material staining. SIGNIFICANCE: Urethane-based low-shrinkage monomer FIT and conventional BisGMA affected color, translucency and color stability of their respective RBCs. Despite being used in posterior teeth, low-shrinkage RBCs are expected to have favorable optical and esthetic properties. Manufacturers are urged to provide information on optical properties of monomers and monomer mixtures in their low-shrinkage RBCs to allow understanding of interaction with fillers and photoinitiators.


Asunto(s)
Color , Resinas Compuestas/química , Fotoiniciadores Dentales/química , Animales , Alcanfor/análogos & derivados , Alcanfor/química , Citrus , Ensayo de Materiales , Leche , Transición de Fase , Fosfinas/química , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Propiedades de Superficie ,
18.
Clin Oral Investig ; 20(7): 1663-73, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26556572

RESUMEN

OBJECTIVES: This study aims to characterize the chemical interplay of hydraulic calcium silicate cements at dentin. MATERIALS AND METHODS: Class I cavities were prepared in non-carious human third molars and filled with Biodentine (Septodont) or ProRoot MTA (Dentsply). After 1-day, 1-week, and 1-month Dulbecco's phosphate-buffered saline (DPBS) storage, the specimens were cross-sectioned perpendicular to the cement-dentin interface. The interfaces were evaluated using micro-Raman (µRaman) spectroscopy and at a higher spatial resolution using field emission gun electron probe microanalysis (Feg-SEM/EPMA). RESULTS: µRaman spectroscopy revealed the formation of a transition zone at the interface of both Biodentine (Septodont) and ProRoot MTA (Dentsply) with dentin, having an average thickness of, respectively, 7.5 ± 4.2 and 6.2 ± 5.4 µm, which however was not statistically different. No difference in interfacial ultrastructure and chemistry was found using µRaman spectroscopy between 1 day, 1 week, and 1 month DPBS-stored specimens. The observation of a transition zone at the cement-dentin interfaces contrasts with the EPMA data that revealed a sharper transition from cement to dentin. Again, no difference in interfacial ultrastructure and chemistry was found for different storage periods, with the exception of one 1 month DPBS-stored specimen prepared using Biodentine (Septodont). More specifically, EPMA revealed a gap of about 10-µm wide in the latter specimen that was filled up with newly formed calcium phosphate depositions. CONCLUSIONS: Up to 1 month, the interaction of hydraulic calcium silicate cements investigated did not reveal ultrastructural or chemical changes at unaffected dentin with the exception of a calcium phosphate gap-filling property. CLINICAL RELEVANCE: Hydraulic calcium silicate cements were found to fill gaps by calcium phosphate deposition, however, without conducting chemical changes to the adjacent dentin.


Asunto(s)
Compuestos de Aluminio/química , Compuestos de Calcio/química , Cementos Dentales/química , Dentina/efectos de los fármacos , Dentina/ultraestructura , Óxidos/química , Cemento de Silicato/química , Silicatos/química , Combinación de Medicamentos , Microanálisis por Sonda Electrónica , Humanos , Técnicas In Vitro , Tercer Molar , Espectrometría Raman
19.
J Dent ; 43(12): 1448-55, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26498727

RESUMEN

OBJECTIVES: The aim of this study was to determine the degree of conversion (DC) and the monomer release of three composite types when employed following a layer- and bulk-filling technique. METHODS: The release of monomers from a 'conventional paste-like' (Filtek Z250), a 'conventional flowable' (Filtek Supreme XTE Flowable) and a 'bulk-fill' flowable composite (Filtek Bulk Fill Flowable) from the same manufacturer (3M ESPE, Seefeld, Germany) was determined. Ten cylindrical specimens per composite were built, either in two 2-mm layers or in one 4-mm bulk. DC was measured at the specimen top and bottom surface using micro-Raman spectroscopy, after which the specimens were immersed in 2 ml absolute ethanol for 24 h at 37 °C. This solution was refreshed weekly during six weeks and the concentration of BisGMA, BisEMA(6), BisPMA, UDMA, TEGDMA and BPA was determined by liquid chromatography/mass spectroscopy. RESULTS: DC at the specimen top and bottom was similar except for the bulk-fill technique, which resulted in significantly lower DC at the specimen bottom. The release of BisGMA and TEGDMA was initially very high, but rapidly dropped in the second week. In contrast, the release of BisPMA and UDMA increased initially, but then declined towards the sixth week. BisEMA(6) release was relatively steady over time. All composites released small amounts of BPA. The total monomer release was significantly lower for the layer- than the bulk-filling technique. CONCLUSIONS: The slightly reduced degree of conversion at 4-mm depth resulted in a higher monomer elution when the composite was applied following a bulk-fill application method. CLINICAL SIGNIFICANCE: Applying a flowable and a bulk-fill composite following a bulk-fill application method resulted in a significantly reduced degree of conversion at the bottom of polymerized composite specimens when compared to a layer-application method. This reduced polymerization degree was reflected in significantly increased monomer release.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Bisfenol A Glicidil Metacrilato/química , Etanol/química , Ensayo de Materiales , Metacrilatos/química , Polietilenglicoles/química , Polimerizacion , Ácidos Polimetacrílicos/química , Poliuretanos/química , Propiedades de Superficie , Espectrometría de Masas en Tándem
20.
Dent Mater ; 31(4): 462-72, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25703341

RESUMEN

OBJECTIVE: To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (µTBS) test after 6 months water storage. METHODS: Chevron-notched beam fracture toughness (CNB) was determined using a modified ISO 24370:2005 standard. Adhesive-dentin micro-specimens (1.0 mm × 1.0 mm × 8-10 mm) were stressed in tensile until failure to determine the micro-tensile bond strength (µTBS). RESULTS: The highest mean µTBS and interfacial fracture toughness were measured for the multi-step adhesives Clearfil SE Bond (Kuraray Noritake) and OptiBond FL (Kerr). While large differences were observed in the bond strength values (from 7.4 to 27.2 MPa) of the one-step self-etch adhesives tested, interfacial fracture toughness was less different (from 0.7 to 1.0 MPam(1/2)). The adhesive with the lowest mean toughness (All-bond Universal, Bisco) had however the highest Weibull reliability, which might be a better parameter in regard to more consistent clinical performance. The self-adhesive composite Vertise Flow (Kerr) scored significantly lower at all levels. SIGNIFICANCE: Although the ranking of the adhesives tested using CNB and µTBS corresponded well, the outcome of CNB appeared more reliable and less variable.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Fracaso de la Restauración Dental , Cementos de Resina/química , Análisis del Estrés Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...