Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Updates Surg ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080095

RESUMEN

BACKGROUND: The aim of this national survey on liver hypertrophy techniques was to track the trends of their use and implementation in Italy and to detect analogies and heterogeneities among centers. METHODS: In December 2022, Italian centers with liver resection activity were specifically contacted and asked to fill an online questionnaire composed of 6 sections including a total of 51 questions. RESULTS: 46 Italian centers filled the questionnaire. The proportion of major/total number of liver resections was 27% and the use of hypertrophy techniques was required in 6,2% of cases. The most frequent reason of drop out was disease progression in 58.5% of cases. Most frequently used techniques were PVE and ALPPS with an increasing use of hepatic venous deprivation (HVD). Heterogeneous answers were provided regarding the cutoff values to indicate the need for hypertrophy techniques. Criteria to allocate a patient to different hypertrophy techniques are not standardized. CONCLUSIONS: The use of hypertrophy techniques is deep-rooted in Italy, documenting the established value of their role in improving resectability rate. While an evolution of techniques is detectable, still significant heterogeneity is perceived in terms of cutoff values, indications and managing protocols.

2.
Radiol Med ; 129(3): 497-506, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38345714

RESUMEN

BACKGROUND: Stereotactic radiotherapy (SRT) and Proton therapy (PT) are both options in the management of liver lesions. Limited clinical-dosimetric comparison are available. Moreover, dose-constraint routinely used in liver PT and SRT considers only the liver spared, while optimization strategies to limit the liver damaged are poorly reported. METHODS: Primary endpoint was to assess and compare liver sparing of four contemporary RT techniques. Secondary endpoints were freedom from local recurrence (FFLR), overall survival (OS), acute and late toxicity. We hypothesize that Focal Liver Reaction (FLR) is determined by a similar biologic dose. FLR was delineated on follow-up MRI. Mean C.I. was computed for all the schedules used. A so-called Fall-off Volume (FOV) was defined as the area of healthy liver (liver-PTV) receiving more than the isotoxic dose. Fall-off Volume Ratio (FOVR) was defined as ratio between FOV and PTV. RESULTS: 213 lesions were identified. Mean best fitting isodose (isotoxic doses) for FLR were 18Gy, 21.5 Gy and 28.5 Gy for 3, 5 and 15 fractions. Among photons, an advantage in terms of healthy liver sparing was found for Vmat FFF with 5mm jaws (p = 0.013) and Cyberknife (p = 0.03). FOV and FOVR resulted lower for PT (p < 0.001). Three years FFLR resulted 83%. Classic Radiation induced liver disease (RILD, any grade) affected 2 patients. CONCLUSIONS: Cyberknife and V-MAT FFF with 5mm jaws spare more liver than V-MAT FF with 10 mm jaws. PT spare more liver compared to photons. FOV and FOVR allows a quantitative analysis of healthy tissue sparing performance showing also the quality of plan in terms of dose fall-off.


Asunto(s)
Neoplasias Hepáticas , Terapia de Protones , Traumatismos por Radiación , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Protones , Dosificación Radioterapéutica , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Traumatismos por Radiación/prevención & control , Neoplasias Hepáticas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...