Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Hernia ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478185

RESUMEN

BACKGROUND: The aim of this multicentre study was to analyse the outcomes of biosynthetic absorbable poly-4-hydroxybutyrate (P4HB) prosthesis implantation in patients undergoing ventral hernia repair (VHR) in the context of different degrees of contamination. METHODS: From May 2016 to December 2021, a multicentre retrospective analysis of patients who underwent elective or urgent hernia repair with P4HB prosthesis was performed in seven hospitals in Spain and Portugal. Patients with a postoperative follow-up of less than 20 months and those within the theoretical period of prosthesis resorption were excluded from the study. Regarding the degree of contamination, patients were assessed according to the modified Ventral Hernia Working Group (VHWG) classification. Epidemiological data, hernia characteristics, surgical and postoperative variables (Clavien-Dindo classification) of these patients were analyzed. Risk factors related to long-term recurrence were studied by a multivariate analysis. RESULTS: In 236 cases of P4HB prosthesis implantation, repair in cases of Grade 3 was the most frequent (49.1%), followed by Grade 2 in 42.3% of cases and Grade 1 in 8.4%. The most frequent complications were Grade 1, with the majority occurring during the first year. The overall rate of surgical site occurrences (SSO) was 30%. The hernia recurrence rate was 14.4% (n = 34), with a mean postoperative follow-up time of 41 months (22-61). The multivariate analysis showed that the onlay location of the mesh (OR 1.07; CI 1.42-2.70, p = 0.004) was a significant independent risk factor for recurrence. CONCLUSIONS: The use of a P4HB bioresorbable mesh for the VHR with different degrees of contamination leads to favourable results overall, with an acceptable rate of hernia recurrence. The onlay location of the P4HB prosthesis is the main factor in recurrence in both elective and emergency settings.

2.
Hernia ; 2023 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-37432512

RESUMEN

OBJECTIVE: Progressive pneumoperitoneum (PPP) is useful tool in the preparation of patients with loss of domain hernias (LODH). The purpose of this observational retrospective study was to report our experience in the management of complications associated with the PPP procedure after treating 180 patients with LODH and to report preventive measures to avoid them. METHODS: Of the 971 patients with a ventral incisional hernia operated on between June 2012 and July 2022, 180 consecutive patients with LODH were retrospectively analysed. Diameters of abdominal cavity, and volumes of incisional hernia and abdominal cavity were calculated from CT scan, based on the modified index of Tanaka. Complications related to the PPP procedure (catheter placement and following insufflations of air) were recorded by Clavien-Dindo classification. RESULTS: Complications associated to PPP were 26.6%. No complications occurred during the administration of botulinum toxin (BT). Eighteen patients (10% of 180 patients) developed subcutaneous emphysema during the last days of the insufflations; there were 2 accidental perforations of the small bowel and four punctures with liver and splenic hematomas, detected during catheter placement; a laparotomy, however, was not needed because it was solved with conservative treatment. We diagnosed it as a peritoneum-cutaneous fistula due to the cutaneous atrophy secondary to chronic eventration. CONCLUSION: PPP is a safe technique well tolerated by patients, although at the cost of some specific complications. Hernia surgeons must understand these complications to prevent them and to inform the LODH patient about their existence.

3.
Hernia ; 25(6): 1593-1600, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34424440

RESUMEN

PURPOSE: To clarify the factors related to recurrence after component separation technique (CST). MATERIALS AND METHODS: A retrospective study was conducted of 381 patients who underwent CST between May 2006 and May 2017 at a tertiary center. All patients had a transverse hernia defect grade W3 in EHS classification. Recurrence rate was determined by clinical examination plus confirmation by abdominal CT scan. RESULTS: At a median of 61.6 months of postoperative follow-up, we reported 34 cases of hernia recurrence (8.9%). On multivariate analysis, BMI > 30 (OR 2.20; CI 1.10-3.91, p = 0.031), immunosuppressive drug use (OR 1.06 CI 1.48-2.75, p = 0.003) and development of surgical site infection (OR 2.7; CI 1.53-4.01, p = 0.002) were factors of recurrence after CST. There was no difference in recurrence rate among repairs of primary and recurrent hernias, urgent repair, operative time, type of prosthesis, or concomitant procedures, even planned or unplanned enterotomies. CONCLUSION: Obesity (BMI > 30), immunosuppressive drug use, and postoperative wound infections were predictors of recurrence after CST.


Asunto(s)
Pared Abdominal , Hernia Ventral , Hernia Incisional , Pared Abdominal/cirugía , Hernia Ventral/cirugía , Herniorrafia/efectos adversos , Herniorrafia/métodos , Humanos , Hernia Incisional/cirugía , Recurrencia , Estudios Retrospectivos , Mallas Quirúrgicas , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/cirugía
4.
Hernia ; 25(4): 1005-1012, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33001317

RESUMEN

PURPOSE: To assess the efficacy of surgical management of chronic mesh infection (CMI) after abdominal wall hernia repair (AWHR) in single-stage approach (complete removal of infected prosthesis and simultaneous replacement with poly-4-hydroxybutyrate mesh or BAM group), comparing results with two-stage treatment (complete mesh excision and abdominal wall repair with synthetic mesh after several months or SPM group). METHODS: Retrospective comparative study of all patients who underwent surgery for CMI between January 2006 and January 2019 at a tertiary center. We compared results in terms of epidemiological data, hernia and prosthesis characteristics, surgical and postoperative variables of both two groups. RESULTS: Over the 13-year study period, 2791 AWHR was performed at our hospital; the overall CMI rate was 2.5%. Of 71 patients, 30 (42.2%) were in BAM group and 41 (57.8%) in SPM group. The median cumulative operative time (252 min versus 132 min) and length of stay (16.6 days versus 6.2 days) were significatively longer in SPM group compared with BAM group, due to the need of two surgical procedures. There were a higher number of postoperative complications in SPM group (p = 0.002), some of them grade III. With mean follow-up of 36.5 months (range 21-59), there were no significant differences in terms of overall hernia recurrence and mesh reinfection in both groups. CONCLUSION: The use of a poly-4-hydroxybutyrate resorbable mesh in single-stage management of CMI may be a safe and better option than two-stage approach, although more studies are needed to confirm our results.


Asunto(s)
Pared Abdominal , Hernia Ventral , Pared Abdominal/cirugía , Hernia Ventral/cirugía , Herniorrafia/efectos adversos , Humanos , Prótesis e Implantes , Recurrencia , Estudios Retrospectivos , Mallas Quirúrgicas/efectos adversos , Resultado del Tratamiento
6.
Colorectal Dis ; 19(5): O126-O133, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28116809

RESUMEN

AIM: To assess the accuracy of magnetic resonance enterography in predicting the extension, location and characteristics of the small bowel segments affected by Crohn's disease. METHOD: This is a prospective study including a consecutive series of 38 patients with Crohn's disease of the small bowel who underwent surgery at a specialized colorectal unit of a tertiary hospital. Preoperative magnetic resonance enterography was performed in all patients, following a homogeneous protocol, within the 3 months prior to surgery. A thorough exploration of the small bowel was performed during the surgical procedure; calibration spheres were used according to the discretion of the surgeon. The accuracy of magnetic resonance enterography in detecting areas affected by Crohn's disease in the small bowel was assessed. The findings of magnetic resonance enterography were compared with surgical and pathological findings. RESULTS: Thirty-eight patients with 81 lesions were included in the study. During surgery, 12 lesions (14.8%) that were not described on magnetic resonance enterography were found. Seven of these were detected exclusively by the use of calibration spheres, passing unnoticed at surgical exploration. Magnetic resonance enterography had 90% accuracy in detecting the location of the stenosis (75.0% sensitivity, 95.7% specificity). Magnetic resonance enterography did not precisely diagnose the presence of an inflammatory phlegmon (accuracy 46.2%), but it was more accurate in detecting abscesses or fistulas (accuracy 89.9% and 98.6%, respectively). CONCLUSION: Magnetic resonance enterography is a useful tool in the preoperative assessment of patients with Crohn's disease. However, a thorough intra-operative exploration of the entire small bowel is still necessary.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Endoscopía del Sistema Digestivo/métodos , Intestino Delgado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cuidados Preoperatorios/métodos , Adolescente , Adulto , Calibración , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/patología , Constricción Patológica/cirugía , Enfermedad de Crohn/patología , Enfermedad de Crohn/cirugía , Femenino , Humanos , Intestino Delgado/patología , Intestino Delgado/cirugía , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad , Adulto Joven
7.
Colorectal Dis ; 18(10): O385-O387, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27454329

RESUMEN

AIM: The study reports an easy technique for surgical management of some forms of ileocolic fistula in Crohn's disease. METHOD: Five patients with Crohn's disease with ileocolic fistula (2011-2014) have been managed by the application of linear stapler devices. RESULTS: Postoperative course was satisfactory in all patients. At 1 year there was no evidence of stricture or fistula formation and no patient had required reoperation. CONCLUSION: The technique is easy and effective and can be used in open and laparoscopic surgery.


Asunto(s)
Enfermedad de Crohn/complicaciones , Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Fístula Intestinal/cirugía , Engrapadoras Quirúrgicas , Grapado Quirúrgico/métodos , Adulto , Colon/cirugía , Enfermedad de Crohn/cirugía , Humanos , Íleon/cirugía , Fístula Intestinal/etiología , Persona de Mediana Edad , Resultado del Tratamiento
8.
Rev Esp Enferm Dig ; 106(3): 216-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25007020

RESUMEN

Colorectal cancer (CRC) is the second most frequent cancer both in incidence and mortality in women, especially in those over 60 years of age. Diagnosis in women at gestational age is rare, so its incidence during pregnancy is low. However, an increase in its diagnosis is expected during the next years because of the raise in the average age of pregnancy.In most cases, the diagnosis is delayed because symptoms related to CRC can be attributed to pregnancy itself. Up to 30 % of CRC cases may present as an intestinal obstruction. In this situation, the main objective is to solve the clinical emergency in the safest way for mother and fetus, together with performing an accurate diagnostic approach to offer the best possible therapeutic management knowing the limitations and difficulties related to pregnancy. The self-expanding metallic stent (SEMS) can be particularly useful in colon obstruction in a pregnant patient with CRC because it allows solving the acute condition providing time to perform a more accurate staging study and to prepare the patient for surgery, thus reducing both post-surgical morbidity and mortality.We report on the case of a patient who early in the second trimester of pregnancy presented with an acute colonic obstruction due to CRC which was successfully managed with the placement of a self-expanding metal stent.


Asunto(s)
Neoplasias Colorrectales/cirugía , Obstrucción Intestinal/cirugía , Complicaciones Neoplásicas del Embarazo/cirugía , Stents , Aborto Terapéutico , Adulto , Neoplasias Colorrectales/complicaciones , Femenino , Humanos , Obstrucción Intestinal/etiología , Embarazo , Segundo Trimestre del Embarazo
11.
Rev Esp Enferm Dig ; 78(2): 99-101, 1990 Aug.
Artículo en Español | MEDLINE | ID: mdl-2271303

RESUMEN

This paper presents on case of adenocarcinoma at the site of colostomy in a patient treated by abdominoperineal amputation five years earlier due to rectal cancer. The case raised the doubt as to whether the carcinoma represented a late, local recurrence or a second metachronic neoplasia. The most frequent location and pathogenesis of each were analyzed. The role of follow-up of these patients in detecting cases such as the one presented here are discussed.


Asunto(s)
Adenocarcinoma/diagnóstico , Colostomía , Recurrencia Local de Neoplasia/diagnóstico , Neoplasias del Recto/diagnóstico , Adenocarcinoma/cirugía , Anciano , Protocolos Clínicos , Femenino , Estudios de Seguimiento , Humanos , Neoplasias del Recto/cirugía
12.
Rev Esp Enferm Dig ; 77(5): 333-6, 1990 May.
Artículo en Español | MEDLINE | ID: mdl-2390354

RESUMEN

We present a retrospective study on the value of peroperative cholangiography (POC) in geriatric patients submitted to elective surgery of the biliary tract. We analyze the results of the present series and compare them with a previous study of 200 cases of cholelithiasis in the general population. Our conclusion is that in geriatric patients, POC should be a routine practice in order to avoid an unnecessary choledochotomy and/or residual lithiasis post-cholecystectomy.


Asunto(s)
Colangiografía , Colecistectomía , Colelitiasis/cirugía , Cálculos Biliares/cirugía , Anciano , Estudios de Evaluación como Asunto , Humanos , Periodo Posoperatorio , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...