Sensors (Basel) ; 16(5)2016 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-27213388

RESUMEN

A standard problem in large tanks at oil refineries and petrol stations is that water and fuel usually occupy the same tank. This is undesirable and causes problems such as corrosion in the tanks. Normally, the water level in tanks is unknown, with the problems that this entails. We propose herein a method based on surface plasmon resonance (SPR) to detect in real time the interfaces in a tank which can simultaneously contain water, gasoline (or diesel) and air. The plasmonic sensor is composed of a hemispherical glass prism, a magnesium fluoride layer, and a gold layer. We have optimized the structural parameters of the sensor from the theoretical modeling of the reflectance curve. The sensor detects water-fuel and fuel-air interfaces and measures the level of each liquid in real time. This sensor is recommended for inflammable liquids because inside the tank there are no electrical or electronic signals which could cause explosions. The sensor proposed has a sensitivity of between 1.2 and 3.5 RIU(-1) and a resolution of between 5.7 × 10(-4) and 16.5 × 10(-4) RIU.

2.
Theor Biol Med Model ; 11 Suppl 1: S1, 2014 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-25079703

RESUMEN

BACKGROUND: In this work, we propose the Halo test, a simple visual test based on a freeware software for quantifying and displaying night-vision disturbances perceived by subjects under different experimental conditions, more precisely studying the influence of the alcohol consumption on visual function. METHODS: In the Halo test, viewed on a monitor, the subject's task consists of detecting luminous peripheral stimuli around a central high-luminance stimulus over a dark background. The test, performed by subjects before and after consuming alcoholic drinks, which deteriorate visual performance, evaluates the influence that alcohol consumption exerts on the visual-discrimination capacity under low illumination conditions. Measurements were made monocularly and binocularly. Pupil size was also measured in both conditions (pre/post). Additionally, we used a double-pass device to measure objectively the optical-quality of the eye and corroborate the results from the Halo test. RESULTS: We found a significant deterioration of the discrimination capacity after alcohol consumption, indicating that the higher the breath-alcohol content, the greater the deterioration of the visual-discrimination capacity. After alcohol intake, the graphical results showed a greater area of undetected peripheral stimuli around the central high-luminance stimulus. An enlargement of the pupil was also observed and the optical quality of the eye was deteriorated after alcohol consumption. CONCLUSIONS: A greater influence of halos and other night-vision disturbances were reported with the Halo test after alcohol consumption. The Halo freeware software constitutes a positive contribution for evaluating nighttime visual performance in clinical applications, such as reported here, but also in patients after refractive surgery (where halos are present) or for monitoring (time course) some ocular pathologies under pharmacological treatment.


Asunto(s)
Consumo de Bebidas Alcohólicas/fisiopatología , Programas Informáticos , Trastornos de la Visión/complicaciones , Trastornos de la Visión/diagnóstico , Pruebas de Visión/métodos , Adulto , Humanos , Persona de Mediana Edad , Pupila , Trastornos de la Visión/fisiopatología , Adulto Joven
3.
J Ophthalmol ; 2014: 704823, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24949202

RESUMEN

Purpose. To evaluate the influence of alcohol consumption on the retinal-image quality and visual performance under surrounding low-illumination conditions. Methods. A volunteer sample of 67 subjects was analyzed. Optical quality of the eye was evaluated by means of the Strehl ratio, the Objective Scattering Index (OSI), and the tear-film quality. We used the visual disturbance index (VDI) to evaluate visual performance under low-illumination conditions and we measured the pupil size under these conditions. The tear-film volume was also measured. All measurements were made before and after alcohol consumption and patients were classified into two groups depending on their breath alcohol content (BrAC): low-alcohol (BrAC < 0.25 mg/L) and high-alcohol content (BrAC ≥ 0.25 mg/L). Results. The VDI was significantly higher after alcohol consumption: the higher the BrAC, the higher the deterioration of the visual discrimination capacity. The pupil size increased significantly for the high-BrAC group. Parameters evaluating optical quality deteriorated after alcohol consumption. Conclusion. The visual performance under low-illumination conditions and the retinal-image quality were deteriorated after alcohol consumption, especially for the high-alcohol group. Furthermore, some physiological changes were observed under effects for high-alcohol contents, such as an increase in the pupil size and disturbances in the tear film, which deteriorated optical quality.