Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Kidney J ; 17(6): sfae101, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38915436

RESUMEN

Background: The aim of this work was to create and evaluate a preoperative non-contrast-enhanced (CE) magnetic resonance imaging (MRI)/angiography (MRA) protocol to assess renal function and visualize renal arteries and any abnormalities in potential living kidney donors. Methods: In total, 28 subjects were examined using scintigraphy to determine renal function. In addition, 3D-pseudocontinuous arterial spin labeling (pCASL), a 2D-non-CE electrocardiogram-triggered radial quiescent interval slice-selective (QISS-MRA), and 4D-CE time-resolved angiography with interleaved stochastic trajectories (CE-MRA) were performed to assess renal perfusion, visualize renal arteries and detect any abnormalities. Two glomerular filtration rates [described by Gates (GFRG) and according to the Chronic Kidney Disease Epidemiology Collaboration formula (GFRCKD-EPI)]. The renal volumes were determined using both MRA techniques. Results: The mean value of regional renal blood flow (rRBF) on the right side was significantly higher than that on the left. The agreements between QISS-MRA and CE-MRA concerning the assessment of absence or presence of an aberrant artery and renal arterial stenosis were perfect. The mean renal volumes measured in the right kidney with QISS-MRA were lower than the corresponding values of CE-MRA. In contrast, the mean renal volumes measured in the left kidney with both MRA techniques were similar. The correlation between the GFRG and rRBF was compared in the same manner as that between GFRCKD-EPI and rRBF. Conclusion: The combination of pCASL and QISS-MRA constitute a reliable preoperative protocol with a total measurement time of <10 min without the potential side effects of gadolinium-based contrast agents or radiation exposure.

2.
J Neurointerv Surg ; 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37852752

RESUMEN

BACKGROUND: The novel Contour Neurovascular System (Contour) has been reported to be efficient and safe for the treatment of intracranial, wide-necked bifurcation aneurysms. Flow in the aneurysm and posterior cerebral arteries (PCAs) after Contour deployment has not been analyzed in detail yet. However, this information is crucial for predicting aneurysm treatment outcomes. METHODS: Time-resolved three-dimensional velocity maps in 14 combinations of patient-based basilar tip aneurysm models with and without Contour devices (sizes between 5 and 14 mm) were analyzed using four-dimensionsal (4D) flow MRI and numerical/image-based flow simulations. A complex virtual processing pipeline was developed to mimic the experimental shape and position of the Contour together with the simulations. RESULTS: On average, the Contour significantly reduced intra-aneurysmal flow velocity by 67% (mean w/ = 0.03m/s; mean w/o = 0.12m/s; p-value=0.002), and the time-averaged wall shear stress by more than 87% (mean w/ = 0.17Pa; mean w/o = 1.35Pa; p-value=0.002), as observed by numerical simulations. Furthermore, a significant reduction in flow (P<0.01) was confirmed by the neck inflow rate, kinetic energy, and inflow concentration index after Contour deployment. Notably, device size has a stronger effect on reducing flow than device positioning. However, positioning affected flow in the PCAs, while being robust in effectively reducing flow. CONCLUSIONS: This study showed the high efficacy of the Contour device in reducing flow within aneurysms regardless of the exact position. However, we observed an effect on the flow in PCAs, which needs to be investigated further.

3.
Antioxidants (Basel) ; 12(6)2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37371977

RESUMEN

The recognition of the role of microglia cells in neurodegenerative diseases has steadily increased over the past few years. There is growing evidence that the uncontrolled and persisting activation of microglial cells is involved in the progression of diseases such as Alzheimer's or Parkinson's disease. The inflammatory activation of microglia cells is often accompanied by a switch in metabolism to higher glucose consumption and aerobic glycolysis. In this study, we investigate the changes induced by the natural antioxidant resveratrol in a human microglia cell line. Resveratrol is renowned for its neuroprotective properties, but little is known about its direct effect on human microglia cells. By analyzing a variety of inflammatory, neuroprotective, and metabolic aspects, resveratrol was observed to reduce inflammasome activity, increase the release of insulin-like growth factor 1, decrease glucose uptake, lower mitochondrial activity, and attenuate cellular metabolism in a 1H NMR-based analysis of whole-cell extracts. To this end, studies were mainly performed by analyzing the effect of exogenous stressors such as lipopolysaccharide or interferon gamma on the metabolic profile of microglial cells. Therefore, this study focuses on changes in metabolism without any exogenous stressors, demonstrating how resveratrol might provide protection from persisting neuroinflammation.

4.
Interv Neuroradiol ; : 15910199221145985, 2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36594503

RESUMEN

BACKGROUND: Recently, a novel intrasaccular device (contour neurovascular system, contour) was introduced to treat intracranial aneurysms. Contour is placed at thе aneurysm neck and reduces the intraaneurysmal blood inflow. Contour comes in a range of sizes to target different aneurysms. The efficiency of altering flow with contour and the effect of device size have not yet been investigated. Therefore, we studied the effect of the device size with patient-based aneurysm models using 2D digital subtraction angiography (DSA). METHODS: Three patient-based aneurysm models with necks ranging from 2.7 to 9.7 mm were produced, providing standardized testing conditions. Contours with diameters of 5, 11, and 14 mm were implanted into the models, four of each size. 2D DSA images were acquired before and after implanting contour (15 frames/s, manual contrast injection). After injecting angiographic contrast agent, the DSA signal was recorded over time to calculate the contrast washout time (WOT), which is a measure of flow diversion efficiency. RESULTS: All contour devices caused contrast agent stasis and increased WOT in aneurysm sac (p-value = 0.0005). The median relative WOT was largest for 5-mm contour (6.6 ± 3.2) and similar for 11-mm contour (3.4 ± 2.6) and 14-mm contour (3.2 ± 3.8). The implantation procedure might affect WOT values even for contours of the same size; the overall relative WOT ranged between 1.5 and 10.89. CONCLUSION: The 5-mm contour showed the longest WOT value in our study, while no apparent difference between 11-mm contour and 14-mm contour was found.

6.
Tomography ; 8(1): 457-478, 2022 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-35202203

RESUMEN

Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels-non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically. Here, we investigated the effect of spatial resolution and CS acceleration on flow measurements by using 4D flow MRI in small vessels in vitro at 3 T. We compared the flow in silicon tubes (inner diameters of 2, 3, 4, and 5 mm) measured with 4D flow MRI, accelerated with four CS factors (CS = 2.5, 4.5, 6.5, and 13) and three voxel sizes (0.5, 1, and 1.5 mm3) to 2D flow MRI and a flow sensor. Additionally, the velocity field in an aneurysm model acquired with 4D flow MRI was compared to the one simulated with computational fluid dynamics (CFD). A strong correlation was observed between flow sensor, 2D flow MRI, and 4D flow MRI (rho > 0.94). The use of fewer than seven voxels per vessel diameter (nROI) resulted in an overestimation of flow in more than 5% of flow measured with 2D flow MRI. A negative correlation (rho = -0.81) between flow error and nROI were found for CS = 2.5 and 4.5. No statistically significant impact of CS factor on differences in flow rates was observed. However, a trend of increased flow error with increased CS factor was observed. In an aneurysm model, the peak velocity and stagnation zone were detected by CFD and all 4D flow MRI variants. The velocity difference error in the aneurysm sac did not exceed 11% for CS = 4.5 in comparison to CS = 2.5 for all spatial resolutions. Therefore, CS factors from 2.5-4.5 can appear suitable to improve spatial or temporal resolution for accurate quantification of flow rate and velocity. We encourage reporting the number of voxels per vessel diameter to standardize 4D flow MRI protocols.


Asunto(s)
Aneurisma , Imagen por Resonancia Magnética , Aceleración , Velocidad del Flujo Sanguíneo , Humanos , Hidrodinámica , Imagen por Resonancia Magnética/métodos
7.
Int J Comput Assist Radiol Surg ; 16(11): 1999-2008, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34519953

RESUMEN

PURPOSE: Intracranial aneurysm (IA) wall enhancement on post-contrast vessel wall magnetic resonance imaging (VW-MRI) is assumed to be a biomarker for vessel wall inflammation and aneurysm instability. However, the exact factors contributing to enhancement are not yet clarified. This study investigates the relationship between luminal enhancement and intra-aneurysmal flow behaviour to assess the suitability of VW-MRI as a surrogate method for determining quantitative and qualitative flow behaviour in the aneurysm sac. METHODS: VW-MRI signal is measured in the lumen of three patient-specific IA flow models and compared with the intra-aneurysmal flow fields obtained using phase-contrast magnetic resonance imaging (PC-MRI) and computational fluid dynamics (CFD). The IA flow models were supplied with two different time-varying flow regimes. RESULTS: Overall, the velocity fields acquired using PC-MRI or CFD were in good agreement with the VW-MRI enhancement patterns. Generally, the regions with slow-flowing blood show higher VW-MRI signal intensities, whereas high flow leads to a suppression of the signal. For all aneurysm models, a signal value above three was associated with velocity values below three cm/s. CONCLUSION: Regions with lower enhancements have been correlated with the slow and high flow at the same time. Thus, further factors like flow complexity and stability can contribute to flow suppression in addition to the flow magnitude. Nevertheless, VW-MRI can qualitatively assess intra-aneurysmal flow phenomena and estimate the velocity range present in the corresponding region.


Asunto(s)
Aneurisma Intracraneal , Velocidad del Flujo Sanguíneo , Humanos , Hidrodinámica , Aneurisma Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética
8.
Front Immunol ; 12: 692222, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34248987

RESUMEN

Imaging techniques have evolved impressively lately, allowing whole new concepts like multimodal imaging, personal medicine, theranostic therapies, and molecular imaging to increase general awareness of possiblities of imaging to medicine field. Here, we have collected the selected (3D) imaging modalities and evaluated the recent findings on preclinical and clinical inflammation imaging. The focus has been on the feasibility of imaging to aid in inflammation precision medicine, and the key challenges and opportunities of the imaging modalities are presented. Some examples of the current usage in clinics/close to clinics have been brought out as an example. This review evaluates the future prospects of the imaging technologies for clinical applications in precision medicine from the pre-clinical development point of view.


Asunto(s)
Inflamación/diagnóstico por imagen , Animales , Diagnóstico por Imagen , Humanos
9.
Expert Rev Med Devices ; 18(6): 569-579, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33890849

RESUMEN

PURPOSE: Braided flow diverters (FD) are highly sophisticated, delicate, and intricate mechanical devices used to treat intracranial aneurysms. Testing such devices in vitro, however, remains an unsolved challenge. Here, we evaluate methods to measure flow, design and mechanical properties in vitro. METHODS: Flow properties, cell porosity, pore density, and cell area were evaluated under geometrically realistic conditions by placing FDs in patient-derived, 3D-printed models of human vasculature. 4D flow MRI was used to measure fluid dynamics. Laser microscopy was used to measure the design properties of the FDs. New methods were developed to investigate the bending, circumferential, and longitudinal radial force of the FDs continuously over varying diameters. RESULTS: The placement and flow properties of the FD in the vasculature models were successfully measured by MRI, although artifacts occurred. Likewise, the porosity, pore density, and cell area were successfully measured inside of the models using a laser microscope. The newly developed mechanical methods allowed to measure the indicated forces - to our knowledge for the first time - continuously. CONCLUSION: Modern and specifically tailored techniques, some of which were presented here for the first time, allow detailed insights into the flow, design, and mechanical properties of braided flow diverter stents.


Asunto(s)
Aneurisma Intracraneal , Stents , Simulación por Computador , Humanos , Aneurisma Intracraneal/cirugía , Porosidad
10.
J Magn Reson Imaging ; 54(3): 888-901, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33694334

RESUMEN

BACKGROUND: Vessel-wall enhancement (VWE) on black-blood MRI (BB MRI) has been proposed as an imaging marker for a higher risk of rupture and associated with wall inflammation. Whether VWE is causally linked to inflammation or rather induced by flow phenomena has been a subject of debate. PURPOSE: To study the effects of slow flow, spatial resolution, and motion-sensitized driven equilibrium (MSDE) preparation on signal intensities in BB MRI of patient-specific aneurysm flow models. STUDY TYPE: Prospective. SUBJECTS/FLOW ANEURYSM MODEL/VIRTUAL VESSELS: Aneurysm flow models based on 3D rotational angiography datasets of three patients with intracranial aneurysms were 3D printed and perfused at two different flow rates, with and without Gd-containing contrast agent. FIELD STRENGTH/SEQUENCE: Variable refocusing flip angle 3D fast-spin echo sequence at 3 T with and without MSDE with three voxel sizes ((0.5 mm)3 , (0.7 mm)3 , and (0.9 mm)3 ); time-resolved with phase-contrast velocity-encoding 3D spoiled gradient echo sequence (4D flow MRI). ASSESSMENT: Three independent observers performed a qualitative visual assessment of flow patterns and signal enhancement. Quantitative analysis included voxel-wise evaluation of signal intensities and magnitude velocity distributions in the aneurysm. STATISTICAL TESTS: Kruskal-Wallis test, potential regressions. RESULTS: A hyperintense signal in the lumen and adjacent to the aneurysm walls on BB MRI was colocalized with slow flow. Signal intensities increased by a factor of 2.56 ± 0.68 (P < 0.01) after administering Gd contrast. After Gd contrast administration, the signal was suppressed most in conjunction with high flows and with MSDE (2.41 ± 2.07 for slow flow without MSDE, and 0.87 ± 0.99 for high flow with MSDE). A clear result was not achieved by modifying the spatial resolution . DATA CONCLUSIONS: Slow-flow phenomena contribute substantially to aneurysm enhancement and vary with MRI parameters. This should be considered in the clinical setting when assessing VWE in patients with an unruptured aneurysm. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aneurisma Intracraneal , Negro o Afroamericano , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Estudios Prospectivos
11.
Med Phys ; 48(4): 1469-1484, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33428778

RESUMEN

PURPOSE: Flow models of intracranial aneurysms (IAs) can be used to test new and existing endovascular treatments with flow modulation devices (FMDs). Additionally, 4D flow magnetic resonance imaging (MRI) offers the ability to measure hemodynamics. This way, the effect of FMDs can be determined noninvasively and compared to patient data. Here, we describe a cost-effective method for producing flow models to test the efficiency of FMDs with 4D flow MRI. METHODS: The models were based on human radiological data (internal carotid and basilar arteries) and printed in 3D with stereolithography. The models were printed with three different printing layers (25, 50, and 100 µm thickness). To evaluate the models in vitro, 3D rotational angiography, time-of-flight MRI, and 4D flow MRI were employed. The flow and geometry of one model were compared with in vivo data. Two FMDs (FMD1 and FMD2) were deployed into two different IA models, and the effect on the flow was estimated by 4D flow MRI. RESULTS: Models printed with different layer thicknesses exhibited similar flow and little geometric variation. The mean spatial difference between the vessel geometry measured in vivo and in vitro was 0.7 ± 1.1 mm. The main flow features, such as vortices in the IAs, were reproduced. The velocities in the aneurysms were similar in vivo and in vitro (mean velocity magnitude: 5.4 ± 7.6 and 7.7 ± 8.6 cm/s, maximum velocity magnitude: 72.5 and 55.1 cm/s). By deploying FMDs, the mean velocity was reduced in the IAs (from 8.3 ± 10 to 4.3 ± 9.32 cm/s for FMD1 and 9.9 ± 12.1 to 2.1 ± 5.6 cm/s for FMD2). CONCLUSIONS: The presented method allows to produce neurovascular models in approx. 15 to 30 h. The resulting models were found to be geometrically accurate, reproducing the main flow patterns, and suitable for implanting FMDs as well as 4D flow MRI.


Asunto(s)
Aneurisma Intracraneal , Velocidad del Flujo Sanguíneo , Hemodinámica , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/diagnóstico por imagen , Imagen por Resonancia Magnética , Impresión Tridimensional
12.
Int J Comput Assist Radiol Surg ; 14(10): 1795-1804, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31054128

RESUMEN

PURPOSE: Assessing the rupture probability of intracranial aneurysms (IAs) remains challenging. Therefore, hemodynamic simulations are increasingly applied toward supporting physicians during treatment planning. However, due to several assumptions, the clinical acceptance of these methods remains limited. METHODS: To provide an overview of state-of-the-art blood flow simulation capabilities, the Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH) was conducted. Seventeen research groups from all over the world performed segmentations and hemodynamic simulations to identify the ruptured aneurysm in a patient harboring five IAs. Although simulation setups revealed good similarity, clear differences exist with respect to the analysis of aneurysm shape and blood flow results. Most groups (12/71%) included morphological and hemodynamic parameters in their analysis, with aspect ratio and wall shear stress as the most popular candidates, respectively. RESULTS: The majority of groups (7/41%) selected the largest aneurysm as being the ruptured one. Four (24%) of the participating groups were able to correctly select the ruptured aneurysm, while three groups (18%) ranked the ruptured aneurysm as the second most probable. Successful selections were based on the integration of clinically relevant information such as the aneurysm site, as well as advanced rupture probability models considering multiple parameters. Additionally, flow characteristics such as the quantification of inflow jets and the identification of multiple vortices led to correct predictions. CONCLUSIONS: MATCH compares state-of-the-art image-based blood flow simulation approaches to assess the rupture risk of IAs. Furthermore, this challenge highlights the importance of multivariate analyses by combining clinically relevant metadata with advanced morphological and hemodynamic quantification.


Asunto(s)
Aneurisma Roto/diagnóstico , Angiografía Cerebral , Aneurisma Intracraneal/diagnóstico , Modelos Cardiovasculares , Aneurisma Roto/fisiopatología , Angiografía Cerebral/métodos , Circulación Cerebrovascular/fisiología , Biología Computacional , Hemodinámica/fisiología , Humanos , Aneurisma Intracraneal/fisiopatología , Medición de Riesgo , Factores de Riesgo
13.
Cardiovasc Eng Technol ; 9(4): 565-581, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30191538

RESUMEN

PURPOSE: Advanced morphology analysis and image-based hemodynamic simulations are increasingly used to assess the rupture risk of intracranial aneurysms (IAs). However, the accuracy of those results strongly depends on the quality of the vessel wall segmentation. METHODS: To evaluate state-of-the-art segmentation approaches, the Multiple Aneurysms AnaTomy CHallenge (MATCH) was announced. Participants carried out segmentation in three anonymized 3D DSA datasets (left and right anterior, posterior circulation) of a patient harboring five IAs. Qualitative and quantitative inter-group comparisons were carried out with respect to aneurysm volumes and ostia. Further, over- and undersegmentation were evaluated based on highly resolved 2D images. Finally, clinically relevant morphological parameters were calculated. RESULTS: Based on the contributions of 26 participating groups, the findings reveal that no consensus regarding segmentation software or underlying algorithms exists. Qualitative similarity of the aneurysm representations was obtained. However, inter-group differences occurred regarding the luminal surface quality, number of vessel branches considered, aneurysm volumes (up to 20%) and ostium surface areas (up to 30%). Further, a systematic oversegmentation of the 3D surfaces was observed with a difference of approximately 10% to the highly resolved 2D reference image. Particularly, the neck of the ruptured aneurysm was overrepresented by all groups except for one. Finally, morphology parameters (e.g., undulation and non-sphericity) varied up to 25%. CONCLUSIONS: MATCH provides an overview of segmentation methodologies for IAs and highlights the variability of surface reconstruction. Further, the study emphasizes the need for careful processing of initial segmentation results for a realistic assessment of clinically relevant morphological parameters.


Asunto(s)
Angiografía Cerebral/métodos , Circulación Cerebrovascular , Hemodinámica , Aneurisma Intracraneal/diagnóstico por imagen , Arteria Cerebral Media/diagnóstico por imagen , Modelos Cardiovasculares , Modelación Específica para el Paciente , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/etiología , Aneurisma Roto/fisiopatología , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Imagenología Tridimensional , Aneurisma Intracraneal/complicaciones , Aneurisma Intracraneal/fisiopatología , Persona de Mediana Edad , Arteria Cerebral Media/fisiopatología , Valor Predictivo de las Pruebas , Pronóstico , Interpretación de Imagen Radiográfica Asistida por Computador , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Estrés Mecánico , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/etiología , Hemorragia Subaracnoidea/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...