Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Can Assoc Radiol J ; 75(3): 609-619, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39086146

RESUMEN

Purpose: To compare image quality and radiation exposure between super- and ultra-high-resolution helical and super-high-resolution volumetric CT of the temporal bone. Methods: Six cadaveric temporal bone specimens were used to evaluate key temporal bone structures using the following CT reconstruction and acquisition modes: helical and single-volume acquisition modes in super-high resolution (0.25-mm slice thickness, 10242 matrix), and helical mode in ultra-high resolution (0.25-mm slice thickness, 20482 matrix). Two observers performed 5 previously described preoperative measurements, measured noise and signal-to-noise ratios for air, and noise for bone, and rated the visualization of 5 anatomical structures on a 4-point scale, for each reconstruction mode. Radiation dose exposure was recorded for each examination. Results: There was no significant difference between any of the quantitative or qualitative measurements in any of the reconstruction and acquisition modes. There was a slight increase in noise and a decrease in signal-to-noise ratio in the air using the single-volume mode (115 ± 13.1 HU and 8.37 ± 0.91, respectively) compared to the helicoidal super-high-resolution (92.4 ± 11.8 HU and 10.8 ± 1.26, respectively) and helicoidal ultra-high-resolution (91.1 ± 10.7 HU and 10.9 ± 1.39, respectively) modes (P < .002). The volumic CT dose index was 50.9 mGy with helical acquisition and 29.8 mGy with single-volume acquisition mode (P < .0001). Conclusion: The single-volume super-high-resolution acquisition mode allows a reduction in radiation dose exposure without compromising image quality compared to helical scanning, but with a slightly lower signal-to-noise ratio in air with the single-volume mode, while there was no difference in image quality between the helical super- and ultra-high-resolution modes.


Asunto(s)
Cadáver , Dosis de Radiación , Relación Señal-Ruido , Hueso Temporal , Humanos , Hueso Temporal/diagnóstico por imagen , Hueso Temporal/anatomía & histología , Tomografía Computarizada Espiral/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos
2.
Diagn Interv Imaging ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38744577

RESUMEN

PURPOSE: The purpose of this study was to evaluate the achievable radiation dose reduction of an ultra-high resolution computed tomography (UHR-CT) scanner using deep learning reconstruction (DLR) while maintaining temporal bone image quality equal to or better than high-resolution CT (HR-CT). MATERIALS AND METHODS: UHR-CT acquisitions were performed with variable tube voltages and currents at eight different dose levels (volumic CT dose index [CTDIvol] range: 4.6-79 mGy), 10242 matrix, and 0.25 mm slice thickness and reconstructed using DLR and hybrid iterative reconstruction (HIR) algorithms. HR-CT images were acquired using a standard protocol (120 kV/220 mAs; CTDI vol, 54.2 mGy, 5122 matrix, and 0.5 mm slice thickness). Two radiologists rated the image quality of seven structures using a five point confidence scale on six cadaveric temporal bone CTs. A global image quality score was obtained for each CT protocol by summing the image quality scores of all structures. RESULTS: With DLR, UHR-CT at 120 kV/220 mAs (CTDIvol, 50.9 mGy) and 140 kV/220 mAs (CTDIvol, 79 mGy) received the highest global image quality scores (4.88 ± 0.32 [standard deviation (SD)] [range: 4-5] and 4.85 ± 0.35 [range: 4-5], respectively; P = 0.31), while HR-CT at 120 kV/220 mAs and UHR-CT at 120 kV/20 mAs received the lowest (i.e., 3.14 ± 0.75 [SD] [range: 2-5] and 2.97 ± 0.86 [SD] [range: 1-5], respectively; P = 0.14). All the DLR protocols had better image quality scores than HR-CT with HIR. CONCLUSION: UHR-CT with DLR can be performed with up to a tenfold reduction in radiation dose compared to HR-CT with HIR while maintaining or improving image quality.

3.
Diagn Interv Imaging ; 105(6): 233-242, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38368178

RESUMEN

PURPOSE: The purpose of this study was to evaluate the ability of ultra-high-resolution computed tomography (UHR-CT) to assess stapes and chorda tympani nerve anatomy using a deep learning (DLR), a model-based, and a hybrid iterative reconstruction algorithm compared to simulated conventional CT. MATERIALS AND METHODS: CT acquisitions were performed with a Mercury 4.0 phantom. Images were acquired with a 1024 × 1024 matrix and a 0.25 mm slice thickness and reconstructed using DLR, model-based, and hybrid iterative reconstruction algorithms. To simulate conventional CT, images were also reconstructed with a 512 × 512 matrix and a 0.5 mm slice thickness. Spatial resolution, noise power spectrum, and objective high-contrast detectability were compared. Three radiologists evaluated the clinical acceptability of these algorithms by assessing the thickness and image quality of the stapes footplate and superstructure elements, as well as the image quality of the chorda tympani nerve bony and tympanic segments using a 5-point confidence scale on 13 temporal bone CT examinations reconstructed with the four algorithms. RESULTS: UHR-CT provided higher spatial resolution than simulated conventional CT at the penalty of higher noise. DLR and model-based iterative reconstruction provided better noise reduction than hybrid iterative reconstruction, and DLR had the highest detectability index, regardless of the dose level. All stapedial structure thicknesses were thinner using UHR-CT by comparison with conventional simulated CT (P < 0.009). DLR showed the best visualization scores compared to the other reconstruction algorithms (P < 0.032). CONCLUSION: UHR-CT with DLR results in less noise than UHR-CT with hybrid iterative reconstruction and significantly improves stapes and tympanic chorda tympani nerve depiction compared to simulated conventional CT and UHR-CT with iterative reconstruction.


Asunto(s)
Aprendizaje Profundo , Fantasmas de Imagen , Hueso Temporal , Tomografía Computarizada por Rayos X , Hueso Temporal/diagnóstico por imagen , Humanos , Tomografía Computarizada por Rayos X/métodos , Estribo/diagnóstico por imagen , Nervio de la Cuerda del Tímpano/diagnóstico por imagen , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos
4.
Eur Radiol ; 33(9): 6381-6391, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37014406

RESUMEN

OBJECTIVE: To compare the diagnostic performance of standard MRI and standard MRI + ZTE images for the detection of rotator cuff calcific tendinopathy (RCCT) and to describe the artifacts encountered with ZTE images, using computed radiography (CR) as a reference. METHODS: In a retrospective study, patients with suspicion of rotator cuff tendinopathy who underwent standard MRI + ZTE images after radiography were enrolled between June 2021 and June 2022. Images were independently analyzed for calcific deposit presence and ZTE images artifacts, by two radiologists. Diagnostic performance was calculated individually with MRI + CR as the reference standard. RESULTS: A total of 46 RCCT subjects (27 women; mean age, 55.3 years ± 12.4) and 51 control subjects (27 men; mean age, 45.5 ± 12.9) were evaluated. For both readers, there was an increase in the sensitivity for the identification of calcific deposits of MRI + ZTE compared to MRI (77% (95% CI: 64.5-86.8) and 75.4% (95% CI: 62.7-85.5) versus 57.4% (95% IC: 44.1-70) and 47.5% (95% IC: 34.6-60.7), for R1 and R2, respectively). Specificity was quite similar for both readers and both imaging techniques and ranged from 96.6% (95% IC: 93.3-98.5) to 98.7% (95% IC: 96.3-99.7). Hyperintense joint fluid (62.8% of patients), long head of the biceps tendon (in 60.8%), and subacromial bursa (in 27.8%) on ZTE were considered artifactual. CONCLUSION: The addition of ZTE images to a standard MRI protocol improved MRI diagnostic performance of RCCT, but with a suboptimal detection rate and a relatively high frequency of artifactual soft tissue signal hyperintensity. KEY POINTS: • Adding ZTE images to standard shoulder MRI improves the MR-based detection of rotator cuff calcific tendinopathy, but half of the calcification unseen with standard MRI remained unseen with ZTE MRI. On ZTE images, joint fluid and long head biceps tendon were hyperintense in about 60% of the shoulders, as well as the subacromial bursa in about 30%, without calcific deposit on conventional radiographs. • The detection rate of calcific deposits using ZTE images was dependent on the disease phase. In the calcific stage, it reached 100% in this study but remained at a maximum of 80.7% in the resorptive phase.


Asunto(s)
Manguito de los Rotadores , Tendinopatía , Masculino , Humanos , Femenino , Persona de Mediana Edad , Adulto , Manguito de los Rotadores/diagnóstico por imagen , Hombro , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Radiografía , Tendinopatía/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...