Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(5)2022 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-35271185

RESUMEN

A new method is proposed in this paper to detect airborne nanoparticles, detecting the light scattering caused by both the particle and the surrounding molecules, which can surpass the limitations of conventional laser optical methods while maintaining simplicity and cost-effectiveness. This method is derived from a mathematical analysis that describes the particle light scattering phenomenon more exactly by including the influence of light scattered from surrounding gas molecules. The analysis shows that it is often too much of a simplification to consider only light scattering from the detected nanoparticle, because light scattering from the surrounding gas molecules, whether visible or invisible to the sensor, is important for nanoparticle detection. An image detection approach utilizing the light scattering from surrounding air molecules is described for the detection of airborne nanoparticles. Tests using monodisperse nanoparticles confirm that airborne particles of around 50 nm in size can even be detected using a low-cost testing device. This shows further that even when using a simple image processing code, captured particle light scattering images can be converted digitally into instantaneous particle counts or concentrations. The factors limiting conventional pulse detection are further discussed. This new method utilizes a simple static light scattering (SLS) approach to enable the development of new devices with better detection capabilities, paving the way for the further development of nanoparticle detection technology.


Asunto(s)
Nanopartículas , Rayos Láser , Tamaño de la Partícula , Dispersión de Radiación
2.
Langmuir ; 38(9): 2751-2762, 2022 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-35192347

RESUMEN

NO2 and SO2, as valuable chemical feedstock, are worth being recycled from flue gases. The separation of NO2 and SO2 is a key process step to enable practical deployment. This work proposes SO2 separation from NO2 using chabazite zeolite (SSZ-13) membranes and provides insights into the feasibility and advantages of this process using molecular simulation. Grand canonical ensemble Monte Carlo and equilibrium molecular dynamics methods were respectively adopted to simulate the adsorption equilibria and diffusion of SO2, NO2, and N2O4 on SSZ-13 at varying Si/Al (1, 5, 11, 71, +∞), temperatures (248-348 K), and pressures (0-100 kPa). The adsorption capacity and affinity (SO2 > N2O4 > NO2) demonstrated strong competitive adsorption of SO2 based on dual-site interactions and significant reduction in NO2 adsorption due to dimerization in the ternary gas mixture. The simulated order of diffusivity (NO2 > SO2 > N2O4) on SSZ-13 demonstrated rapid transport of NO2, strong temperature dependence of SO2 diffusion, and the impermeability of SSZ-13 to N2O4. The membrane permeability of each component was simulated, rendering a SO2/NO2 membrane separation factor of 26.34 which is much higher than adsorption equilibrium (6.9) and kinetic (2.2) counterparts. The key role of NO2-N2O4 dimerization in molecular sieving of SO2 from NO2 was addressed, providing a facile membrane separation strategy at room temperature.

3.
Sci Rep ; 11(1): 20268, 2021 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-34642467

RESUMEN

Intentionally intensifying the light scattering of medium molecules can allow the detection of suspended nanoparticles under conditions not suitable for conventional optical microscopies or laser particle counters. Here, we demonstrate how the collective light scattering of medium molecules and nanoparticles is imaged in response to the power, frequency, and oscillating direction of the incident light wave electric field, and how this response can be used to distinguish between nanoparticles and microparticles, such as viruses or bacteria. Under conditions that the medium light scattering is intensified, suspended nanoparticles appear as magnified shiny moving dots superimposed on the quasi-steady background of medium light scattering. Utilizing the visual enlargement resulted from the enhanced light scattering and possible light interference, we can detect directly suspended nanoparticles that are much smaller than visible light wavelengths even in unopened water bottles or other large containers. This suggests new approaches for detecting nanoparticles with many potential applications.

4.
J Am Dent Assoc ; 152(12): 981-990, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34538418

RESUMEN

BACKGROUND: Dental procedures often produce aerosols and spatter, which have the potential to transmit pathogens such as severe acute respiratory syndrome coronavirus 2. The existing literature is limited. METHODS: Aerosols and spatter were generated from an ultrasonic scaling procedure on a dental manikin and characterized via 2 optical imaging methods: digital inline holography and laser sheet imaging. Capture efficiencies of various aerosol mitigation devices were evaluated and compared. RESULTS: The ultrasonic scaling procedure generated a wide size range of aerosols (up to a few hundred µm) and occasional large spatter, which emit at low velocity (mostly < 3 m/s). Use of a saliva ejector and high-volume evacuator (HVE) resulted in overall reductions of 63% and 88%, respectively, whereas an extraoral local extractor (ELE) resulted in a reduction of 96% at the nominal design flow setting. CONCLUSIONS: The study results showed that the use of ELE or HVE significantly reduced aerosol and spatter emission. The use of HVE generally requires an additional person to assist a dental hygienist, whereas an ELE can be operated hands free when a dental hygienist is performing ultrasonic scaling and other operations. PRACTICAL IMPLICATIONS: An ELE aids in the reduction of aerosols and spatters during ultrasonic scaling procedures, potentially reducing transmission of oral or respiratory pathogens like severe acute respiratory syndrome coronavirus 2. Position and airflow of the device are important to effective aerosol mitigation.


Asunto(s)
COVID-19 , Ultrasonido , Aerosoles , Raspado Dental , Humanos , SARS-CoV-2
5.
Build Environ ; 205: 108254, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34400851

RESUMEN

Due to the ongoing COVID-19 pandemic situation, measures to mitigate the risk of transmission of the SARS-CoV-2 virus in an indoor setting are urgently needed. Among the various types of disinfectant methods, electrostatic spraying is often applied to decontamination in public places. For quantitatively characterizing electrostatic spraying, we developed the novel evaluation method by using a fluorescent tracer. By applying this method, we performed three different experiment cases (static test on a table, static test on a cylinder, and dynamic test on a table) to figure out its unique characteristics (Coulombic fission and wraparound effect) and measure its performance in various aspects. To be specific, bimodal distribution with peak sizes of ~10 and ~100 µm was found due to Coulombic fission. Otherwise, a unimodal distribution with a peak size of ~100 µm occurred for the uncharged droplets. As a result, the effective contact area increased by 40-80 % due to small progeny droplets. The wraparound effect was examined on two different cylinders: copper (Cu) and polyvinyl chloride (PVC) pipe. When the target surface was not charged (Cu 0 kV and PVC 0 kV), the average normalized concentrations on the backside of the cylinder (θ = 180°) increased by around 67 % for charged droplets. Meanwhile, when the target surface was highly charged (PVC -19 kV), the average normalized concentrations at θ = 180° were increased more than two times for charged droplets.

7.
J Aerosol Sci ; 150: 105609, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32834104

RESUMEN

This study aims to evaluate the filtration performance of three commercially available (3M 8210 respirator, Halyard 48207 surgical mask, and 3M 1820 procedure mask) and two alternative face mask and respirator materials (Halyard H600 sterilization wrap and Cummins EX101) after selected decontamination treatments, including isopropanol (IPA) treatments (soaking or spraying), ultraviolet germicidal irradiation (UVGI), and heat treatments (dry heat at 77 °C or steam heat). Both IPA soaking and spraying removed most electrostatic charges on all four electret materials (three commercial and one alternative), causing significant deterioration of filtration efficiency to unacceptable level. The other non-electret alternative material sustained its N95-grade performance after both IPA soaking and spraying treatments, demonstrating the possible application of IPA disinfection for non-electret alternative respirator/mask materials. UVGI preserved the filtration of all three commercially available respirator/mask materials after up to 10 treatments, suggesting it can be a possible decontamination method for hospital and clinic use without compromising respirator/mask performance. The considerations of the practical implementation of this method was discussed. Between the two heat treatment methods tested, dry heat showed better compatibility with electret material by sustaining both filtration efficiency and fit (tested on commercial respirator only), although adding moisture was reported in favor of virus inactivation. Heat treatment is easily accessible method for general publics to implement at home, while it is recommended to maintain the moisture level below saturation. Comparing to size-integrated method, the size-resolved fractional efficiency measurement technique, although more time consuming, proved to be a better method for evaluating respirator/mask filtration performance after decontaminations by providing more sensitive detection of performance degradation and the capability of distinguishing charge loss to other mechanisms causing efficiency deterioration. Detailed descriptions are provided in methodology part to emphasize the cares needed for an appropriate efficiency evaluation. The limited results in this study on worn masks made of alternative sterilization wrap indicated possible performance degradation of electret material caused by normal human wearing activities, suggesting the need of assessing respirator/mask decontamination strategy by testing practically worn-and-decontaminated/reused samples instead of unworn only-decontaminated counterparts.

8.
J Environ Manage ; 262: 110301, 2020 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-32250785

RESUMEN

Previous studies of the residents' willingness to pay (WTP) for air quality improvement are likely suffering various endogeneity biases. Exploiting the unique opportunity of a recent quasi-experiment operation of the world's first SFT (Smog Free Tower) in China's northwestern city Xi'an, this paper reliably calibrates local residents' WTP for less exposure to haze by analyzing the price responses of housings in the neighborhoods of SFT. The hedonic regression is applied in the DID (difference-in-difference) setting, with further assistances of the PSM (propensity score matching) method, quantile regression and placebo test. The regression results consistently suggest that housing price responded positively to the installment of the SFT, and the impact estimates are closely centered around 4%. The study also indicates high-priced housings response much more to the operation of the SFT than cheap-priced housings, suggesting uneven distribution of welfare gains of air quality improvement. A cost-benefit analysis of the SFT project indicates that the economic benefits of this project far outweigh the costs involved. The paper concludes with discussions of policy implications of this paper for environment governance.


Asunto(s)
Contaminación del Aire , China , Ciudades , Vivienda , Características de la Residencia
9.
J Hazard Mater ; 386: 121928, 2020 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-31884354

RESUMEN

Adsorption as one of the most important air cleaning methods has been extensively applied during which the coexisting airborne nanoparticles (NPs) with sizes close to adsorbent pore sizes could inevitably influence gas adsorption processes. In this work, the influence of sub-20 nm NPs on toluene adsorption on ZSM-5 zeolites exchanged with different cations (Li+, Na+ and K+) were studied based on gas-and-particle coexisting adsorption/filtration tests. Affinities for both toluene and NPs on adsorbents follow Li-ZSM-5 > Na-ZSM-5 > K-ZSM-5 regarding the orders of charge density, pore size, and internal and external specific surface areas. The toluene adsorption was shown to be impaired by coexisting NPs from perspectives of thermodynamics and kinetics. For Li-ZSM-5, Na-ZSM-5 and K-ZSM-5, significant relative reductions of 10.4 %, 10.5 % and 16.0 % in toluene adsorption capacity at the lower feed concentration, and of 20.3 %, 15.2 % and 2.3 % in mass transfer coefficient at the higher feed concentration were observed, respectively. The influential mechanisms regarding competitiveness between toluene and NPs in interaction with cationic and porous surfaces were accordingly proposed, which are of practical significance for selecting robust adsorbents under realistic harsh air conditions.

10.
Sci Total Environ ; 626: 134-146, 2018 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-29335168

RESUMEN

Atmospheric simulations were carried out over the terrain of entire Beijing, China, to investigate the effectiveness of an air-pollution cleaning system named Solar-Assisted Large-Scale Cleaning System (SALSCS) for PM2.5 mitigation by using the Weather Research and Forecasting (WRF) model. SALSCS was proposed to utilize solar energy to generate airflow therefrom the airborne particulate pollution of atmosphere was separated by filtration elements. Our model used a derived tendency term in the potential temperature equation to simulate the buoyancy effect of SALSCS created with solar radiation on its nearby atmosphere. PM2.5 pollutant and SALSCS clean air were simulated in the model domain by passive tracer scalars. Simulation conditions with two system flow rates of 2.64 × 105 m3/s and 3.80 × 105 m3/s were tested for seven air pollution episodes of Beijing during the winters of 2015-2017. The numerical results showed that with eight SALSCSs installed along the 6th Ring Road of the city, 11.2% and 14.6% of PM2.5 concentrations were reduced under the two flow-rate simulation conditions, respectively.

11.
Ann Work Expo Health ; 61(6): 737-747, 2017 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-28609786

RESUMEN

Elevated concentrations of diesel exhaust have been linked to adverse health effects. Filtering facepiece respirators (FFRs) are widely used as a form of respiratory protection against diesel particulate matter (DPM) in occupational settings. Previous results (Penconek A, Drazyk P, Moskal A. (2013) Penetration of diesel exhaust particles through commercially available dust half masks. Ann Occup Hyg; 57: 360-73.) have suggested that common FFRs are less efficient than would be expected for this purpose based on their certification approvals. The objective of this study was to measure the penetration of DPM through NIOSH-certified R95 and P95 electret respirators to verify this result. Gravimetric-based penetration measurements conducted using polytetrafluoroethylene (PTFE) and polypropylene (PP) filters were compared with penetration measurements made with a Scanning Mobility Particle Sizer (SMPS, TSI Inc.), which measures the particle size distribution. Gravimetric measurements using PP filters were variable compared to SMPS measurements and biased high due to adsorption of gas phase organic material. Relatively inert PTFE filters adsorbed less gas phase organic material resulting in measurements that were more accurate. To attempt to correct for artifacts associated with adsorption of gas phase organic material, primary and secondary filters were used in series upstream and downstream of the FFR. Correcting for adsorption by subtracting the secondary mass from the primary mass improved the result for both PTFE and PP filters but this correction is subject to 'equilibrium' conditions that depend on sampling time and the concentration of particles and gas phase hydrocarbons. Overall, the results demonstrate that the use of filters to determine filtration efficiency of FFRs challenged with diesel exhaust produces erroneous results due to the presence of gas phase hydrocarbons in diesel exhaust and the tendency of filters to adsorb organic material.


Asunto(s)
Filtros de Aire/normas , Contaminantes Ocupacionales del Aire , Filtración/métodos , Exposición por Inhalación/análisis , Máscaras/normas , Ensayo de Materiales/métodos , Dispositivos de Protección Respiratoria , Emisiones de Vehículos/análisis , Aerosoles/análisis , Filtración/normas , Humanos , National Institute for Occupational Safety and Health, U.S. , Material Particulado/análisis , Estados Unidos
12.
J Nanosci Nanotechnol ; 15(12): 9554-64, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26682378

RESUMEN

Indoor air quality has great impact on the human health. An increasing number of studies have shown that printers could release particulate matters and pose adverse effects on indoor air quality. In this study, a thorough investigation was designed to assess the aerosol printer particle total number concentration (TNC) and size distribution in normal office environment, one copy center, and a clean chamber. Particle analyzers, SMPS, OPS, and CPC3007 were used to monitor the total printing process. In normal office environment, 37 laser printers out of all surveyed 55 printers were classified as high particle emitters. Comparing to laser printers, 5 inkjet printers showed no particle emission. Particle emission level in a copy center increased slightly with TNC elevating to about 2 times of the aerosol background. Simulating test in a clean chamber indicated that printer-emitted particles were dominated by particles in nanoscale (diameter of particle, D(p) < 100 nm). These particles in a sealed clean chamber attenuated so slowly that it still held at high level with the concentration of 1.5 x 10(4) particles/cm3 after printing for 2.5 hours. Our present results demonstrate that printers indeed release particulates which keeping at a high concentration level in the indoor environment. Special care should be taken to this kind of widely applied machines and effective controls of particle emission at printing processes are necessary.


Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente , Nanopartículas/análisis , Impresión , Exposición Profesional/análisis , Tamaño de la Partícula , Material Particulado/análisis
13.
Ann Occup Hyg ; 59(9): 1135-51, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26209597

RESUMEN

Recent animal studies have shown that carbon nanotubes (CNTs) may pose a significant health risk to those exposed in the workplace. To further understand this potential risk, effort must be taken to measure the occupational exposure to CNTs. Results from an assessment of potential exposure to multi-walled carbon nanotubes (MWCNTs) conducted at an industrial facility where polymer nanocomposites were manufactured by an extrusion process are presented. Exposure to MWCNTs was quantified by the thermal-optical analysis for elemental carbon (EC) of respirable dust collected by personal sampling. All personal respirable samples collected (n = 8) had estimated 8-h time weighted average (TWA) EC concentrations below the limit of detection for the analysis which was about one-half of the recommended exposure limit for CNTs, 1 µg EC/m(3) as an 8-h TWA respirable mass concentration. Potential exposure sources were identified and characterized by direct-reading instruments and area sampling. Area samples analyzed for EC yielded quantifiable mass concentrations inside an enclosure where unbound MWCNTs were handled and near a pelletizer where nanocomposite was cut, while those analyzed by electron microscopy detected the presence of MWCNTs at six locations throughout the facility. Through size selective area sampling it was identified that the airborne MWCNTs present in the workplace were in the form of large agglomerates. This was confirmed by electron microscopy where most of the MWCNT structures observed were in the form of micrometer-sized ropey agglomerates. However, a small fraction of single, free MWCNTs was also observed. It was found that the high number concentrations of nanoparticles, ~200000 particles/cm(3), present in the manufacturing facility were likely attributable to polymer fumes produced in the extrusion process.


Asunto(s)
Aerosoles/análisis , Contaminantes Ocupacionales del Aire/análisis , Nanocompuestos , Nanotubos de Carbono/análisis , Exposición Profesional/análisis , Polímeros , Animales , Polvo/análisis , Monitoreo del Ambiente/métodos , Filtración/instrumentación , Humanos , Exposición por Inhalación/análisis , Pulmón/química , Industria Manufacturera , Microscopía Electrónica de Rastreo , Tamaño de la Partícula , Lugar de Trabajo
14.
Ann Occup Hyg ; 59(6): 812-6, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25846360

RESUMEN

Viability, fluorescence (particle volume), photometric, viral RNA, and particle number penetration of MS2 bacteriophage through filter media used in three different models of respirators were compared to better understand the correlation between viability and physical penetration. Although viability and viral RNA penetration were better represented by particle volume penetration than particle number penetration, they were several-fold lower than photometric penetration, which was partially due to the difference in virus survival between upstream and downstream aerosol samples. Results suggest that the current NIOSH photometer-based test method can be used as a quick means to roughly differentiate respirators with different performance against virus aerosols.


Asunto(s)
Aerosoles/análisis , Filtración/métodos , Dispositivos de Protección Respiratoria/normas , Virus , Contaminantes Ocupacionales del Aire/análisis , Exposición por Inhalación , Nanopartículas/análisis , National Institute for Occupational Safety and Health, U.S. , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Tamaño de la Partícula , Fotometría , Estados Unidos
15.
Appl Environ Microbiol ; 80(9): 2796-803, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24561592

RESUMEN

Laboratory studies of virus aerosols have been criticized for generating airborne viruses from artificial nebulizer suspensions (e.g., cell culture media), which do not mimic the natural release of viruses (e.g., from human saliva). The objectives of this study were to determine the effect of human saliva on the infectivity and survival of airborne virus and to compare it with those of artificial saliva and cell culture medium. A stock of MS2 bacteriophage was diluted in one of three nebulizer suspensions, aerosolized, size selected (100 to 450 nm) using a differential mobility analyzer, and collected onto gelatin filters. Uranine was used as a particle tracer. The resulting particle size distribution was measured using a scanning mobility particle sizer. The amounts of infectious virus, total virus, and fluorescence in the collected samples were determined by infectivity assays, quantitative reverse transcription-PCR (RT-PCR), and spectrofluorometry, respectively. For all nebulizer suspensions, the virus content generally followed a particle volume distribution rather than a number distribution. The survival of airborne MS2 was independent of particle size but was strongly affected by the type of nebulizer suspension. Human saliva was found to be much less protective than cell culture medium (i.e., 3% tryptic soy broth) and artificial saliva. These results indicate the need for caution when extrapolating laboratory results, which often use artificial nebulizer suspensions. To better assess the risk of airborne transmission of viral diseases in real-life situations, the use of natural suspensions such as saliva or respiratory mucus is recommended.


Asunto(s)
Medios de Cultivo/química , Levivirus/crecimiento & desarrollo , Saliva Artificial/química , Saliva/virología , Aire/análisis , Microbiología del Aire , Humanos
16.
Environ Sci Technol ; 47(22): 12721-7, 2013 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-24144041

RESUMEN

Abrasive Waterjet Machining (AWM) and Electrical Discharge Machining (EDM) processes are found to produce nanoparticles during operation. Impacts of engineered nanoparticles released to the environment and biological system have caused much concern. Similarly, the nanoparticles unintentionally produced by the AWM and EDM can lead to comparable effects. By application of the Nanoparticle Tracking Analysis (NTA) technique, the size distribution and concentration of nanoparticles in the water used in AWM and EDM were measured. The particles generally have a peak size of 100-200 nm. The filtration systems of the AWM and EDM processes were found to remove 70% and 90% the nanoparticles present, respectively. However, the particle concentration of the filtered water from the AWM was still four times higher than that found in regular tap water. These nanoparticles are mostly agglomerated, according to the microscopy analysis. Using the electron dispersive spectroscopy (EDS) technique, the particles are confirmed to come from the debris of the materials cut with the equipment. Since AWM and EDM are widely used, the handling and disposal of used filters collected with nanoparticles, release of nanoparticles to the sewer, and potential use of higher performance filters for these processes will deserve further consideration.


Asunto(s)
Nanopartículas/química , Nanotecnología/métodos , Electricidad , Filtración , Nanopartículas/ultraestructura , Tamaño de la Partícula
17.
Influenza Other Respir Viruses ; 7(5): 637-44, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23398976

RESUMEN

BACKGROUND: To experimentally determine the survival kinetics of influenza virus on personal protective equipment (PPE) and to evaluate the risk of virus transfer from PPE, it is important to compare the effects on virus recovery of the method used to contaminate the PPE with virus and the type of eluent used to recover it. METHODS: Avian influenza virus (AIV) was applied as a liquid suspension (spike test) and as an aerosol to three types of non-woven fabrics [polypropylene (PP), polyester (PET), and polyamide (Nylon)] that are commonly used in the manufacture of PPE. This was followed by virus recovery using eight different eluents (phosphate-buffered saline, minimum essential medium, and 1.5% or 3.0% beef extract at pH 7, 8, or 9). RESULTS: For spike tests, no statistically significant difference was found in virus recovery using any of the eluents tested. Hydrophobic surfaces (PP and PET) yielded higher spiked virus recovery than hydrophilic Nylon. From all materials, the virus recovery was much lower in aerosol challenge tests than in spike tests. CONCLUSIONS: Significant differences were found in the recovery of viable AIV from non-woven fabrics between spike and aerosol challenge tests. The findings of this study demonstrate the need for realistic aerosol challenge tests rather than liquid spike tests in studies of virus survival on surfaces where airborne transmission of influenza virus may get involved.


Asunto(s)
Aerosoles/análisis , Microbiología del Aire , Virus de la Influenza A/aislamiento & purificación , Gripe Humana/virología , Textiles/virología , Animales , Línea Celular , Humanos , Virus de la Influenza A/genética , Virus de la Influenza A/crecimiento & desarrollo , Polímeros/análisis
18.
Chem Eng Sci ; 85: 69-76, 2013 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-23355749

RESUMEN

Carbon nanotubes (CNTs) tend to form bundles due to their geometry and van der Walls forces, which usually complicates studies of the CNT properties. Dispersion plays a significant role in CNT studies and we summarize dispersion techniques to generate airborne CNTs from suspensions or powders. We describe in detail our technique of CNT aerosolization with controlled degree of agglomeration using an electrospray system. The results of animal inhalation studies using the electrosprayed CNTs are presented. We have performed filtration experiments for CNTs through a screen filter. A numerical model has been established to simulate the CNT filtration experiments. Both the modeling and experimental results show that the CNT penetration is less than the penetration for a sphere with the same mobility diameter, which is mainly due to the larger interception length of the CNTs. There is a need for instruments capable of fast and online measurement of gas-borne nanoparticle agglomerates. We developed an instrument Universal NanoParticle Analyzer (UNPA) and the measurement results for diesel exhaust particulates are presented. The results presented here are pertinent to non-spherical aerosol particles, and illustrate the effects of particle morphology on aerosol behaviors.

19.
Am J Infect Control ; 41(1): 80-2, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22483237

RESUMEN

Physical penetration and infectivity penetration of adenovirus and influenza virus aerosols through respirators were measured to better characterize the effectiveness of filtering facepiece respirators against airborne virus. A physical penetration of 2%-5% was found. However, large sample-to-sample variation made it difficult to quantify the difference in physical penetration caused by the different virus aerosols. Infectivity penetration of adenovirus was much lower than physical penetration, indicating that the latter provides a conservative estimate for respirator performance.


Asunto(s)
Adenoviridae/aislamiento & purificación , Aerosoles , Microbiología del Aire , Filtración/métodos , Orthomyxoviridae/aislamiento & purificación , Dispositivos de Protección Respiratoria , Humanos , Control de Infecciones/métodos , Viabilidad Microbiana
20.
Ann Occup Hyg ; 56(5): 581-94, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22752097

RESUMEN

The National Institute for Occupational Safety and Health (NIOSH) developed a standard for respirator certification under 42 CFR Part 84, using a TSI 8130 automated filter tester with photometers. A recent study showed that photometric detection methods may not be sensitive for measuring engineered nanoparticles. Present NIOSH standards for penetration measurement are mass-based; however, the threshold limit value/permissible exposure limit for an engineered nanoparticle worker exposure is not yet clear. There is lack of standardized filter test development for engineered nanoparticles, and development of a simple nanoparticle filter test is indicated. To better understand the filter performance against engineered nanoparticles and correlations among different tests, initial penetration levels of one fiberglass and two electret filter media were measured using a series of polydisperse and monodisperse aerosol test methods at two different laboratories (University of Minnesota Particle Technology Laboratory and 3M Company). Monodisperse aerosol penetrations were measured by a TSI 8160 using NaCl particles from 20 to 300 nm. Particle penetration curves and overall penetrations were measured by scanning mobility particle sizer (SMPS), condensation particle counter (CPC), nanoparticle surface area monitor (NSAM), and TSI 8130 at two face velocities and three layer thicknesses. Results showed that reproducible, comparable filtration data were achieved between two laboratories, with proper control of test conditions and calibration procedures. For particle penetration curves, the experimental results of monodisperse testing agreed well with polydisperse SMPS measurements. The most penetrating particle sizes (MPPSs) of electret and fiberglass filter media were ~50 and 160 nm, respectively. For overall penetrations, the CPC and NSAM results of polydisperse aerosols were close to the penetration at the corresponding median particle sizes. For each filter type, power-law correlations between the penetrations measured by different instruments show that the NIOSH TSI 8130 test may be used to predict penetrations at the MPPS as well as the CPC and NSAM results with polydisperse aerosols. It is recommended to use dry air (<20% RH) as makeup air in the test system to prevent sodium chloride particle deliquescing and minimizing the challenge particle dielectric constant and to use an adequate neutralizer to fully neutralize the polydisperse challenge aerosol. For a simple nanoparticle penetration test, it is recommended to use a polydisperse aerosol challenge with a geometric mean of ~50 nm with the CPC or the NSAM as detectors.


Asunto(s)
Aerosoles/análisis , Contaminantes Ocupacionales del Aire/análisis , Filtración/instrumentación , Ensayo de Materiales/normas , Nanopartículas/análisis , Valores Limites del Umbral , Contaminantes Ocupacionales del Aire/química , Contaminantes Ocupacionales del Aire/normas , Calibración , Diseño de Equipo , Filtración/normas , Filtración/estadística & datos numéricos , Vidrio , Humanos , Exposición por Inhalación/prevención & control , Ensayo de Materiales/métodos , Ensayo de Materiales/estadística & datos numéricos , Nanopartículas/química , Nanopartículas/normas , National Institute for Occupational Safety and Health, U.S./normas , Tamaño de la Partícula , Fotometría , Dispositivos de Protección Respiratoria/normas , Cloruro de Sodio , Electricidad Estática , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...