Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 74(4): 1103-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25311135

RESUMEN

PURPOSE: We propose the use of a retrospectively gated cine fast spin echo (FSE) sequence for characterization of carotid artery dynamics. The aim of this study was to compare cine FSE measures of carotid dynamics with measures obtained on prospectively gated FSE images. METHODS: The common carotid arteries in 10 volunteers were imaged using two temporally resolved sequences: (i) cine FSE and (ii) prospectively gated FSE. Three raters manually traced a common carotid artery area for all cardiac phases on both sequences. Measured areas and systolic-diastolic area changes were calculated and compared. Inter- and intra-rater reliability were assessed for both sequences. RESULTS: No significant difference between cine FSE and prospectively gated FSE areas were observed (P = 0.36). Both sequences produced repeatable cross-sectional area measurements: inter-rater intraclass correlation coefficient (ICC) = 0.88 on cine FSE images and 0.87 on prospectively gated FSE images. Minimum detectable difference (MDD) in systolic-diastolic area was 4.9 mm(2) with cine FSE and 6.4 mm(2) with prospectively gated FSE. CONCLUSION: This cine FSE method produced repeatable dynamic carotid artery measurements with less artifact and greater temporal efficiency compared with prospectively gated FSE.


Asunto(s)
Arterias Carótidas/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Adulto , Femenino , Humanos , Masculino , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...