Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Bone Joint Surg Am ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739702

RESUMEN

BACKGROUND: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study. METHODS: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively. The study involved measuring the medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), hip-knee-ankle angle (HKA), joint line obliquity (JLO), joint-line convergence angle (JLCA), and arithmetic HKA (aHKA). The aHKA represents a method for estimating constitutional alignment using angles that are unaffected by joint-space narrowing. RESULTS: Strong correlations (p < 0.001) between the imaging modalities were found for the HKA (correlation coefficient, 0.912), aHKA (0.883), MPTA (0.820), LDFA (0.871), and JLO (0.778). A weaker correlation was observed for the JLCA in valgus knees as compared with varus knees (Spearman coefficients, 0.412 and 0.518, respectively). Regression models demonstrated that the degree of agreement was associated with the preoperative intra-articular deformity and the positioning of the lower limb during the CT scan (i.e., the lower-limb rotational angle). An initial JLCA within ±5° was associated with higher agreement. CONCLUSIONS: We observed a strong correlation between LLRs and CT scanograms that were made during the preoperative planning stage of robotic-arm-assisted knee arthroplasty, implying that CT scanograms can reliably be utilized to estimate the coronal alignment of the knee, potentially replacing the need for LLRs. Nevertheless, to attain a higher degree of agreement, it is crucial to ensure appropriate radiographic positioning of the lower limb. Additionally, surgeons must remain vigilant regarding potential discrepancies in cases involving substantial deformities. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

2.
Orthop Clin North Am ; 54(2): 121-140, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36894286

RESUMEN

Hip, spine, and pelvis function as a unified kinetic chain. Any spinal pathology, results in compensatory changes in the other components to accommodate for the reduced spinopelvic motion. The complex relationship between spinopelvic mobility and component positioning in total hip arthroplasty presents a challenge in achieving functional implant positioning. Patients with spinal pathology, especially those with stiff spines and little change in sacral slope, are at high instability risk. In this challenging subgroup, robotic-arm assistance enables the execution of a patient specific plan, avoiding impingement and maximizing range of motion; especially utilizing virtual range of motion to dynamically assess impingement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Sacro , Rango del Movimiento Articular
3.
Int Orthop ; 47(2): 573-584, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36496548

RESUMEN

INTRODUCTION: Accurate implant positioning, tailored to the phenotype and unique biomechanics of each patient is the single most important objective in achieving stability in THA and maximise range of motion. The spine-pelvis-hip construct functions as a single unit adapting to postural changes. It is widely accepted in the literature that no universaltarget exists and variations in spinopelvic mobility mandate adjustments to the surgical plan; thus bringing to the fore the concept of personalised, functional component positioning. METHODS: This manuscript aims to outline the challenges posed by spinopelvic imbalance and present a reproducible, stepwise approach to achieve functional-component positioning. We also present the one-year functional outcomes and Patient Reported Outcome Measures of a prospective cohort operated with this technique. RESULTS AND CONCLUSION: Robotic-arm assisted Total Hip Arthroplasty has facilitated enhanced planning based on the patient's phenotype and evidence suggests it results in more reproducible and accurate implant positioning. Preservation of offset, avoiding leg-length discrepancy, accurate restoration of the centre of rotation and accomplishing the combinedversion target are very important parameters in Total Hip Arthroplasty that affect post-operative implant longevity, patient satisfaction and clinical outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Prospectivos , Satisfacción del Paciente , Pelvis
4.
Medicina (Kaunas) ; 58(11)2022 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-36363573

RESUMEN

Robotic-arm-assisted total hip arthroplasty (RoTHA) offers the opportunity to improve the implant positioning and restoration of native hip mechanics. The concept of individualised, functional implant positioning and how it relates to spinopelvic imbalance is an important yet rather novel consideration in THA. There is mounting evidence that a significant percentage of dislocations occur within the perceived "safe zones"; hence, in the challenging subset of patients with a stiff spinopelvic construct, it is imperative to employ individualised component positioning based on the patients' phenotype. Restoring the native centre of rotation, preserving offset, achieving the desired combined anteversion and avoiding leg length inequality are all very important surgeon-controlled variables that have been shown to be associated with postoperative outcomes. The latest version of the software has a feature of virtual range of motion (VROM), which preoperatively identifies potential dynamic causes of impingement that can cause instability. This review presents the workflow of RoTHA, especially focusing on pragmatic solutions to tackle the challenge of spinopelvic imbalance. Furthermore, it presents an overview of the existing evidence concerning RoTHA and touches upon future direction.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Flujo de Trabajo , Brazo , Rango del Movimiento Articular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...